Disconnect the Real Time Clock battery from PJ3 on the system board and
5.
remove the battery.
WARNING: If you replace the RTC battery, be sure to use only batteries
recommended by Toshiba. Installation of the wrong battery can cause the
battery to explode or otherwise cause damage.
Disconnect the panel close sensor cable from PJ10 and the LED cable from
6.
PJ14 on the system board.
Remove one M2.5x8 screw from the sub-battery base.
7.
Figure 4-18 Removing the top cover and display assembly
4-20
Figure 4-17 Removing the RTC battery