Page 19
A A R09JSALBWKNCV (115V) AR12JSALBWKNCV (115V) AR09JSFLBWKNCV(230V) AR12JSALBWKNCV (230V) Open the front panel and remove it. Remove screw fixing on the terminal cover. Remove the terminal cover Slide out the 2 air filters.
Page 24
A A R18JSFLBWKNCV(230V) Open the front panel and remove it. Remove screw fixing on the terminal cover. Remove the terminal cover Slide out the 2 air filters.
Page 29
A A R24JSFLBWKNCV(230V) Open the front panel and remove it. Remove screw fixing on the terminal cover. Remove the terminal cover Slide out the 2 air filters. 4-12...
Page 46
6-1 Indoor main PCB--9k/12k CN1:transformer IN 3:POWER L (OUT) 4(AC-L):POWER L (IN) #1:POWER L 1# POWER L (OUT) 1#POWER L (IN) #3:POWER N CN2:transformer OUT CN3:AC-MOTOR ACN:POWER N #1:12V AC #1:Motor start capacitor #1:POWER N #2: 12V AC #3:AC phase control singal #2:POWER N #5:Power N CN4:MOTOR_F/B...
Page 48
6-2 Indoor main PCB--18k P2:POWER N NO:POWER L (OUT) COM(AC-L):POWER L (IN) #1:POWER N 1# POWER L (OUT) 1#POWER L (IN) CN11:Ion CN3:DC-MOTOR CN5-1:STEP MOTOR #1:AC phase control singa #1:Feedback signal input CN5-2:STEP MOTOR #3:POWER N #2 DC phase control singal #1 +12V #3:+15V #2~5:STEP MOTOR signal...
Page 50
6- Indoor main PCB--24k CN5-1:STEP MOTOR NO:POWER L (OUT) COM(AC-L):POWER L (IN) CN5-2:STEP MOTOR 1# POWER L (OUT) 1#POWER L (IN) #1 +12V #2~5:STEP MOTOR signal CN6:TEMPERATURE SENSOR CN3:DC-MOTOR P2(AC-N):POWER N #1:RT_TEMP #1:Feedback signal input #1:POWER N #2~3:GND #2 DC phase control singal #2:POWER N #4:IPT_TEMP #3:+15V...
Page 57
Detach the assembled sensor from the PCB sensor connector and measure the sensor resistance with ohmmeter(tester) Replace the sensor Sensor resistance value : 20°C- 6.0836kohm 30°C - 4.1331kohm 35°C -3.4352kohm 40°C- 2.8699kohm Connect the sensor to PCB connector (4pin in) supply power and measure the voltage of the connector accordingly Below 0.5V or Over 4.5V...
Page 58
Is capacity of fan motor capacitor ok Replace it Is the relay accordingly or Is there outlet of fan connector(speed Replace it controller silicon ok accordingly) Check the winding of motor accordingly Replace PCB Is running of motor shaft smooth Replace it Replace it...
Page 64
Indoor display DESCRIPTION Indoor Display of LED LED DISPLAY Compressor frequency drive fault Outdoor display Outdoor display of LED Outdoor unit LED Flashes (times) LED DISPLAY LED ON Re-energize and check the protection code on display. Firstly display P0. If this code is displayed when the compressor is started for several seconds or even not started, check the compressor connection for correctness, if no insert wrong, replace outdoor PCB.