QUESTIONS OR COMMENTS? COUNTRY CALL OR VISIT US ONLINE AT 1800 3000 8282 - Toll Free INDIA www.samsung.com/in/support 1800 266 8282 - Toll Free This product is roHS compliant RAC BORACAY_EN_Eco-inverter IBIM_05124A-00.indd 56 2014-12-18 오후 3:06:59...
AR18JV5HATQ AR18JV5HBTQ AR12JV5HBWK AR18JV5HBWK AR24JV5HBWK Air Conditioner user & installation manual (include Warranty Card) This manual is made with 100% recycled paper. imagine the possibilities Thank you for purchasing this Samsung product. DB68-05124A-00 RAC BORACAY_EN_Eco-inverter IBIM_05124A-00.indd 1 2014-12-18 오후 3:06:35...
Page 3
Features of your new air conditioner 2-Step cooling 2-Step cooling function will quickly cool the room to reach the desired temperature and then it will adjust the fan speed and air flow direction automatically to help you stay comfortable and refreshed.
If you have any questions, call your nearest contact center or find help and information online at www.samsung.com. Important safety symbols and precautions: Hazards or unsafe practices that may result in severe WARNING personal injury or death.
Page 6
Do not install this appliance near a heater, inflammable material. Do not install this appliance in a humid, oily or dusty location, in a location exposed to direct sunlight and water (rain drops). Do not install this appliance in a location where gas may leak. ...
Page 7
Safety precautions WARNING FOR POWER SUPPLY Remove all foreign substances such as dust or water from the power plug terminals and contact points using a dry cloth on a regular basis. Unplug the power plug and clean it with a dry cloth. ...
Page 8
WARNING FOR USING If the appliance is flooded, please contact your nearest service center. Failure to do so may result in electric shock or fire. If the appliance generates a strange noise, a burning smell or smoke, unplug the power plug immediately and contact your nearest service center.
Page 9
Safety precautions WARNING FOR USING Do not insert your fingers or foreign substances into the outlet when the air conditioner is operating. Take special care that children do not injure themselves by inserting their fingers into the product. Do not touch the air flow blade with your hands or fingers during the heating operation.
Page 10
CAUTION FOR USING Do not place objects or devices under the indoor unit. Water dripping from the indoor unit may result in fire or property damage. Check that the installation frame of the outdoor unit is not broken at least once a year.
Page 11
Safety precautions WARNING FOR CLEANING Do not clean the appliance by spraying water directly onto it. Do not use benzene, thinner or alcohol to clean the appliance. This may result in discoloration, deformation, damage, electric shock or fire. Before cleaning or performing maintenance, unplug the air conditioner from the wall socket and wait until the fan stops.
Checking before use Operation ranges The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table below for efficient use. Mode Indoor temperature Outdoor temperature Indoor humidity Cooling ˚C~30 ˚C 21 ˚C~52 ˚C Relative humidity 80% or less 18 ˚C~30 ˚C 21 ˚C~52 ˚C...
Checking the name of the parts Your air conditioner may slightly look different from illustration shown below depending on your model. Main parts Room temperature sensor Air filter (under the panel) Air intake Air flow blade Blade pin lever Display, Power button (up and down) (left and right) and Remote controller receiver...
Checking the remote controller • Point the remote controller towards the remote controller receiver of the indoor unit. • W hen you properly press the button on the remote controller, you will hear beep sound from the indoor unit and a transmit indicator( ) appears on the remote controller display. Remote controller buttons Vertical air swing Activate/Deactivate vertical air flow blade movement automatically Power Mode Turn on/off the air Set one of the 4 operating modes conditioner Temp + –...
Page 15
Checking the remote controller Remote controller display Transmit indicator Operation mode Low battery indicator indicator Set temperature/ Time (for Fan speed indicator Timer option) indicator good'sleep indicator Vertical air swing indicator Options indicator Settings indicator • Make sure that the water does not get to the remote controller . • Heat mode / Virus Doctor / d'light Cool / Usage / Filter Reset / Display function is displayed on the remote controller display but not supported in this model .
Basic function Basic operation is an operation mode that can be selected by pressing the Mode button . auto In Auto mode, the air conditioner will automatically set the temperature and fan speed depending on the room temperature . Cool In Cool mode, the air conditioner will cool your room .
Page 17
Basic function Press the button to turn on the air conditioner. Press the button to set the operating mode. • Each time you press the Mode button, the mode will change in order of Auto, Cool, Dry, Fan and Heat. ❇ ❇ Heat mode can be selected, displayed in the remote controller and make a beep sound when selected, but the air conditioner is not actually operating in selected mode .
adjusting the air flow direction Air flow can be directed to your desired position. Vertical air flow This function will allow you to adjust the air flow direction vertically . Press the button to make air flow blades vertically. f To keep the air flow direction in a constant direction, press the button again .
Setting the On/Off timer Setting the On timer When the air conditioner is off; 1. Press the Timer button to select (On). - (On) indicator will keep blinking and you can set the time . 2. Press the button to set the time. - You can set the time in half hour unit from 30 minutes (0 .
Setting the Off timer When the air conditioner is on; 1. Press the Timer button to select (Off). - (Off) indicator will keep blinking and you can set the time . 2. Press the button to set the time. - You can set the time in half hour unit from 30 minutes (0 . 5 on the display) ~ 3 hours and hour unit from 3~24 hours .
mode For a comfortable sleep, the air conditioner will operate in 3 stages in order of Fall asleep Sound sleep Wake up stage . When the air conditioner is operating in Cool/Heat mode; 1. Press the Timer button to select ( ) indicator will keep blinking and you can set the time .
2-Step cooling function 2-Step cooling function will set the air conditioner to cool the room quickly to reach the set temperature when the indoor temperature is higher than the set temperature, and then the air conditioner will automatically operate in Dry mode when indoor temperature reaches set temperature .
Using the Fast function You can set the Fast function to provide fast and powerful cooling. When the air conditioner is operating in Cool mode. 1. Press the Options button. 2. Press the or Options button until (Fast) indicator starts to blink. 3.
Using the Single User function This function will reduce the energy usage while the air conditioner is operating in Cool mode. When the air conditioner is operating in Cool mode. Press the Single user button on the remote controller. f (Single user) indicator will be displayed on the remote controller display . Then "...
Using the Quiet function You can reduce the noise generated from an indoor unit during Cool mode. When the air conditioner is operating in Cool mode; 1. Press the Options button. 2. Press the or Options button until (Quiet) indicator starts to blink. 3.
Using the auto Clean function Auto clean function will minimise the moisture inside of the indoor unit. Activate this function to help provide you with clean air. When the air conditioner is operating; 1. Press the Settings button. 2. Press the button until (Clean) indicator starts to blink.
Cleaning the air conditioner • Make sure the power is turned off and unplugged from the wall CAUTION socket when cleaning the air conditioner. Cleaning the indoor unit f Clean the product with a tepid damp cloth . f Remove the dust accumulated in the gap of the product with a soft brush .
Page 28
Cleaning the outdoor unit heat exchanger When dust accumulates on the heat exchanger, it may decrease cooling performance. Therefore, clean it regularly. Spray water to clean the dust. Heat exchanger • I f it is difficult to clean the outdoor unit heat exchanger on (Illustration may differ slightly your own, contact service center.
Page 29
Cleaning the air conditioner Removing the Air filter Grab the handle and lift it up. Then, pull the Air filter towards you and slide it down. Air filter (Illustration may differ slightly depending on the models) Cleaning the air filter Washable foam based air filter captures large particles from the air.
Maintaining the air conditioner If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best condition. 1. Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and disconnect the power plug.
Troubleshooting Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses. PROBLEM SOLUTION The air conditioner • C heck power status and then operate the air conditioner does not work at all. again. • P lug in or switch on the circuit breaker and then operate the air conditioner again. • C heck if you have set the Off Timer. Operate the air conditioner again by pressing the Power button.
Page 32
PROBLEM SOLUTION Fan speed • C heck if you have selected Auto/Dry/Fast/ adjustment is not mode. In these modes, fan speed is set to Auto and you working. cannot adjust the fan speed. Remote controller is • Check if your batteries are depleted. not working. • M ake sure nothing is blocking your remote controller sensor.
In order to help prevent electric shocks, fires or injuries, always stop the unit, disable the protection switch and contact SAMSUNG’s technical support if the unit produces smoke, if the power cable is hot or damaged or if the unit is very noisy. Always remember to inspect the unit, electric connections, refrigerant tubes and protections regularly. These operations ...
Installing the unit IMPORTANT: W hen installing the unit, always remember to connect first the refrigerant tubes, then the electrical lines. Always disassemble the electric lines before the refrigerant tubes. Upon receipt, inspect the product to verify that it has not been damaged during transport. f If the product appears damaged, DO NOT INSTALL it and immediately report the damage to the carrier or retailer (if the installer or the authorized technician has collected the material from the retailer.) After completing the installation, always carry out a functional test and provide the instructions on how to operate the air f...
Choosing the installation location Outdoor Unit Where it is not exposed to strong wind Well ventilated and dustless places Where possible keep out of sunlight and rain Where neighbors are not annoyed by operation sound or hot air f Solid wall or support that prevents vibration and is strong enough to hold the product weight ...
Page 36
Space Requirements for Outdoor Unit When installing 1 outdoor unit f Figure Description Top view Side view Air intake Air outlet Air intake Air outlet Air flow direction . ❇ ❇ (Unit : mm) f When the air outlet is opposite f When the air outlet is towards f When 3 sides of the outdoor unit the wall...
Page 37
Choosing the installation location When installing more than 1 outdoor unit (Unit : mm) f When the air outlet is towards the wall f When 3 sides of the outdoor unit are blocked by the wall 300 or more 600 or more 600 or more 600 or more f When the walls are blocking front and the rear side of the...
Fixing the installation plate You can select the direction of the drain hose depending on where you want to install the indoor unit . Therefore before fixing the installation plate to a wall or a window frame, you must determine the position of the 65 mm hole through which the cable, pipe and hose pass to connect the indoor unit to the outdoor unit .
Connecting the assembly cable Cable specification Model Interconnection cable 4G X 1 . 5 mm ² , H07RN-F ✴✴12/18✴✴ 3G X 1 . 0 mm ² , H07RN-F ✴✴24✴✴ 1 X 0 . 7 5mm , H05RN-F ² • Connect the power cable to the auxiliary circuit breaker . If every pole fails to connect to the power supply, it must be incorporated in a wire with a contact opening of ≥...
Connecting the assembly cable 9. Connect the cables to the terminals as seen in the picture. • Each wire is labeled with the corresponding terminal number . Indoor unit ✴✴24✴✴ ✴✴12/18✴✴ Indoor unit Ground wire Ground wire (Green/Yellow) (Green/Yellow) Outdoor unit Ground wire...
Installing and connecting the assembly pipe of the indoor unit Connect indoor and outdoor units with field-supplied copper pipes by means of flare connections. Use insulated seamless refrigeration grade pipe only, (Cu DHP type according to ISO1337), degreased and deoxidized, suitable for operating pressures of at least 4200 kPa and for burst pressure of at least 20700 kPa. Under no circumstances must sanitary type copper pipe be used. There are 2 refrigerant pipes of different diameters: • The smaller one is for the liquid refrigerant • The larger one is for the gas refrigerant A short pipe is already fitted to the air conditioner.
Evacuating the indoor unit The indoor unit is supplied with inert gas (nitrogen). Before installing the unit, check if nitrogen gas flows out of indoor unit. If this one isn’t true, DO NOT INSTALL THE UNIT since leakage could be inside the indoor unit. 1.
Page 44
4. Put a flare nut slightly into the pipe and modify the flare. Outer Diameter (D) Depth (A) Flaring Size (B) ø6.35 mm 1.3 mm 9.0 mm ø9.52 mm 1.8 mm 13.0 mm ø12.70 mm 2.0 mm 16.2 mm ø15.88 mm 2.2 mm 19.3 mm Pipe...
Installing and connecting the drain hose of the indoor unit When installing the drain hose for the indoor unit, check if condensation draining is adequate . When passing the drain hose through the 65 mm hole drilled in the wall, check the following: Wall Indoor unit Drain hose...
Changing direction of the drain hose Change the direction only when it is necessary . Screw hole 1. Detach the rubber cap with the plier. Drain hose 2. Detach the drain hose by pulling it and turning to the left. 3.
Evacuating the connected pipes The outdoor unit is loaded with sufficient R-410A refrigerant . Do not vent R-410A into atmosphere: it is a fluorinated greenhouse gas, covered by Kyoto Protocol, with a Global Warming Potential (GWP) = 2088 . You should evacuate the air in the indoor unit and in the pipe . If air remains in the refrigerant pipes, it affects the compressor . It may cause reduction of cooling capacity and malfunction .
adding refrigerant Add refrigerant charge according to table below: If you use a pipe longer than 5 m, 15 g of refrigerant R-410A must be added for each extra meter . If you use a pipe shorter than 5 m, The evacuating time is normal . Refer to the Service Manual for further details .
Performing the gas leak tests Make sure to check for gas leaks before completing the installation process (connecting the assembly pipe and hose between indoor unit and outdoor unit, insulating the cables, hose and pipe, and fixing the indoor unit to the installation plate). Test part for outdoor unit Test part for indoor unit Tightening torque for body cap...
Fixing the indoor unit in place Perform the following work on the area where gas leak test was done priory . Insulation After checking for gas leaks in the system, insulate the pipe, hose and cables . Then place the indoor unit on the installation plate . 1.
Smart Install mode This model supports Smart Install mode which checks installation status to find out if there is any problems with any of the functions . Execute Smart Install mode after installation . 1. Check the installation status of the air conditioner through communication between indoor & outdoor. 1) Check the power supply, service valve (open/close), wiring $ piping connection of the indoor and outdoor unit and additional refrigerant charge in case of longer pipe than design specification .
Page 52
2) Smart Install mode in progress • 88 Display : Progress will be displayed in 0~99 . • LED Display : Indicator on the indoor unit display will blink in sequence and then all indicators will blink . (This will be repeated .
Final check and trial operation To complete the installation, perform the following checks and tests to ensure that the air conditioner operates correctly. Check the followings: • Strength of the installation site • Tightness of pipe connection to detect gas leak • Electric wiring connection • Heat-resistant insulation of the pipe • Drainage • Grounding conductor connection • Correct operation (follow the steps below) 1. Press the Power button and check the following: The indicator on the indoor unit lights up.
How to connect your extended power cables Items to prepare (compressor and insulation tape should be prepared by an installation technician.) Tools Crimping pliers Connection sleeve (mm) Insulation tape Contraction tube (mm) Spec MH-14 20xØ7.0(HxOD) Width 18 mm 50xØ8.0(LxOD) Shape 1.
Page 55
English-54 RAC BORACAY_EN_Eco-inverter IBIM_05124A-00.indd 54 2014-12-18 오후 3:06:58...
Page 56
English-55 RAC BORACAY_EN_Eco-inverter IBIM_05124A-00.indd 55 2014-12-18 오후 3:06:58...