6. Electrical Parts List 6 -1 INDOOR MAIN PCB - DB92-04839A 6 -2 ASSY PCB DISPLAY - DB92-04833B 6 -3 ASSY MODULE- DB92-04837A 6 -4 ASSY PCB INVERTER DB92-04838A 7. Wiring Diagram 7-1 Indoor Unit 7-1 Outdoor Unit SAMSUNG ELECTRONICS...
Page 4
11-2 Outdoor unit 12. Reference Sheet 12-1 Low Refrigerant Pressure Distribution 12-2 Pressure & Capacity mark 12-3 Q & A for Non-trouble 12-4 Cleaning /Filter Change 12-5 Installation 12-6 Installation Diagram of Indoor Unit and Outdoor Unit 12-7 Reference sheet SAMSUNG ELECTRONICS...
Make sure that the air conditioner is well ventilated at all times. Do not place a cloth or other materials over it. • Remove the batteries if you don't use the remote control for a long time. (If applicable) • Use the remote control within 7 meters from the indoor unit. (If applicable) SAMSUNG ELECTRONICS...
• Young children or infirm persons should be always supervised when they use the air conditioner. • Max current is measured according to IEC standard for safety. • Current is measured according to ISO standard for energy efficiency. SAMSUNG ELECTRONICS...
It’s so easy to install! You can easily hang the product on the wall and connect the pipes and wires by opening the cover on the bottom of the product. Now you won’t have to tilt the product to connect the pipe and the wires! SAMSUNG ELECTRONICS...
-10 °C to 46 °C -10 °C to 46 °C Operation range 27 °C or less 27 °C or less 27 °C or less Heating -15 °C to 24 °C -15 °C to 24 °C -15 °C to 24 °C SAMSUNG ELECTRONICS...
ASSY WIRELESS REMOCON DB96-24901C MANUAL USER DB68-08595A MANUAL USER DB68-08615A Indoor unit case MANUAL INSTALL DB68-08692A HOLDER REMOCON DB61-06087A Batteries for Remote controller 4301-000121 M4 x 12 Tapped Screws 6002-000213 Rubber Leg DB67-01533A Outdoor unit case Drain plug DB67-20011A SAMSUNG ELECTRONICS...
• Because the teat mode operate the cool mode by force not related to the set temperature / indoor temperature, check whether each subordinate is operated normally or not after completing Note installation and must turn off the power of the air conditioner. SAMSUNG ELECTRONICS...
K1 filter feed back error C665 DRAIN PUMP ERROR ✴✴Note✴✴ If the Set doesn’t work (No power), check the Thermal fuse of Terminal block OPEN or SHORT with Multimeter. Measure the Thermal fuse housing PIN#1 2 : OPEN(disconnection) -> defective productIf ✴ SAMSUNG ELECTRONICS...
Page 13
AC Input I_limit trip error C554 Gas leak error C574 Gas shortage error C422 EEV or valve close error-self diagnosis Test operation at Cooling mode Test operation at Heating mode : LAMP ON : LAMP OFF : LAMP BLINK SAMSUNG ELECTRONICS...
1. Tack out the batteries of remote control. 2. Press the temperature button simultaneously and insert the battery again. 3. Make sure the remote control display shown as Step 2 Enter the Options Setup mode and select your options asscording to the following procedure. SAMSUNG ELECTRONICS...
Page 15
When pressing the operation ON/OFF key with the direction of remote control for the sound’’Ding’’or ’’Diriring’’isheard and the OPERATION ICON( ) lampof the display is flickering at the same time, then the input of option is completed. (If the deriving sound isn't heard, try again pressing the ON/ OFF button.) SAMSUNG ELECTRONICS...
Page 16
Every time you push the button, the display panel reads . . . repeatedly. Push the Mode button to set the display panerl to 1. Every time you push the button, the display panel reads . . . repeatedly. SAMSUNG ELECTRONICS...
Page 17
2. If the unit is not working properly or all lamps are continuously flickering setting the option code, see if the correct option code is set up for this model ■ Option Items Option code Model name set Gerneral Install AR09TXFCAWK/EU 011A05-17C0EA-271920-371804 020000-100000-200101-300335 AR12TXFCAWK/EU 011A05-17C0FA-272323-371804 020000-100000-200101-300335 AR24TXEAAWK/EU 011A05-16C25B-27414A-371404 020000-100000-200101-300357 SAMSUNG ELECTRONICS...
Remark +SCREW DRIVER Q’ty 1 ea. To assembly and disassembly the screw MONKEY SPANNER Q’ty 1 ea. To assembly and disassembly the Fan motor and Compressor - SCREW DRIVER Q’ty 1 ea. To assembly and disassembly the screw SAMSUNG ELECTRONICS...
2) Detach FILTER PRE from the PANEL FRONT. 3) The COVER PANEL is fixed to body by hooks in center and side area. 4) Separate the hook pulling end of the COVER PANEL as shown in figures.(Watch out for the damage of hooks) SAMSUNG ELECTRONICS...
Page 20
- Need to check all bottom hooks in holes of the main frame before you push to assemble. Caution: - Assemble(push) side hooks - Assemble(push) center 5 hooks each. SAMSUNG ELECTRONICS...
Page 21
(use (+) Screw Driver) 8) To detach the PANEL FRONT from the main frame, loosen 4 hook structures. When separate the hooks: pull out each ribs near the hooks as shown in figures. (Watch out for the damage of hooks) SAMSUNG ELECTRONICS...
Page 22
CONTROL-IN 10)To open the CONTROL-IN, raise the side flanges of the PLATE-RIGHT at an angle and unlock 2 hooks. 11)To detach the CONTROLIN, unfasten a screw back of the PLATE-LEFT as shown in figures. (use (+) Screw Driver) SAMSUNG ELECTRONICS...
Page 23
Caution: When you separate the connector, pull pressing the locking button. 13)Separate Blade Motor wire as shown in figures. Caution: When you separate the connector, pull pressing the locking button. 14)Cut off the Cable Tie tied up wires. SAMSUNG ELECTRONICS...
Page 24
(Please loosen remaining connectors before detaching CASE-CONTROL. Caution: When you separate the connector, pull pressing the locking button. 17) Put down of the HOLDER PIPE and push up the hook and lean side the case as shown in figures. SAMSUNG ELECTRONICS...
Page 25
Parts Procedure Remark TRAY DRAIN 18) To detach the TRAY DRAIN from the main frame, pull the bottom of the TRAY DRAIN and it leans toward to you as shown in figures. 19) Pull out the Drain Hose. SAMSUNG ELECTRONICS...
Page 26
Motor side as shown in figures. (Watch out for the damate of hooks) 22)Remove the HOLDER PIPE. 23)Unfasten a screw of the Fan Motor side. (Use (+) Screw Driver.) 24)Unfasten 2 screws of the opposite side of the Fan Motor. (Use (+) Screw Driver.) SAMSUNG ELECTRONICS...
Page 27
Parts Procedure Remark EVAPORATOR 25) Pull up the EVAPORATOR of the opposite side of the Fan Motor 26) loosen a hook of the Fan Motor side. 27) Pull up the EVAPORATOR toward to you. SAMSUNG ELECTRONICS...
Page 28
29) Unwind the Motor Wire. 30)Detach the COVER Motor. 31) Unfasten a screw of the CROSS FAN a little. (Use (+) Screw Driver.) 32)Raise up the CROSS FAN of the left side and pull out from the Motor. SAMSUNG ELECTRONICS...
1EA (+ screw driver Use) 4) Please remove the portions of the side screw 1. (+ screw driver Use) 5) Please separate lifting up and grab the ends of the lower end of the CABINET FRONT. SAMSUNG ELECTRONICS...
Page 30
(use + screwdriver) 7) Please separate the screw 2ea located on the side panel. (+ screw driver Use) 8) Please separate the screw 4ea located on the side panel.(+ screw driver Use) 9) Please remove the COVER CONTROL OUT downward. SAMSUNG ELECTRONICS...
Page 31
11) Please remove the CABINET SIDE upward direction. FAN&MOTOR 1) Please Loosen the NUT 1ea clockwise. (Using MONKEY SPANNER) 2) Please remove the HOUSING’s MOTOR WIRE. 3) Remove the fixing points of the motor SCREW 2ea, please disconnect the MOTOR turning counterclockwise. SAMSUNG ELECTRONICS...
Page 32
Assy Control Out 1) To remove the Cover control box : Pull the motor wire is allow sufficient space as shown on the right side and then remove the screw. 2) Detach several connectors from the Assy Control Out. SAMSUNG ELECTRONICS...
Page 33
2) Please separate NUT SERVICEVALVE 2EA. (MONKEY SPANNER or + SCREW DRIVER Use). Condenser 1) Please remove the welds in one place. (COND-IN) (heat exchanger) 2) Please separate the two sides fixing screws loose. (+ SCREW DRIVER Use) SAMSUNG ELECTRONICS...
Page 34
2) Disassemble COVERTERMINAL after remove the OLP. BE CAUTION Engraved position : C (black), S (white), R (red) [OLP internal compressor] 2) Please disassemble COVERTERMINAL. *** how to distinguish from OLP internal, external compressor : Check the compressor label SAMSUNG ELECTRONICS...
Page 35
Parts Procedure Remark 3) Please remove the compressor after loosen the compressor fixed NUT 3ea. (Using MONKEY SPANNER) 4) Please detach the two welds. (SUCTION, DISCHARGE) SAMSUNG ELECTRONICS...
Page 36
1) Loosen fixing screws from the cabi side Rh and detach it. 2) L oosen each sc rews and detach the Cabi Top Cover. 3) Loosen fixing screws from the cabi side. 4) Loosen fixing screws from the cabi side Rh and detach it. SAMSUNG ELECTRONICS...
Page 37
Parts Procedure Remark Common work 5) Loosen fixing screws from the 6) L oosen fixing screws from the Cabi left and detach it and Remove the 4 Cond Bar from the holderof outdoor unit cabinet. SAMSUNG ELECTRONICS...
Page 38
(Use Monkey Spanner.) 2) Detach the Fan Propeller. 3) Loosen 4 fixing screws to detach the Motor. (Use Monkey Spanner.) 4) Disconnect the wire between Assy Control Out and Motor. 5) Loosen fixing bolts and detach the Bracket Motor SAMSUNG ELECTRONICS...
Page 39
3) Detach several connectors from the PCB of Assy Control Out. Heat Exchanger 1) Release the refrigerant at first. 2) Loosen ng screw on both sides. 3) Disassemble the pipes in both inlet and outlet with welding torch. 4) Detach the Heat Exchanger. SAMSUNG ELECTRONICS...
Page 40
Parts Procedure Remark Compressor 1) Loosen the ng nut and detach the Compressor Lead Wire. (Use Monkey Spanner.) 2) Loosen the bolts at the bottom of Compressor like the picture on the right side. (Use Monkey Spanner.) SAMSUNG ELECTRONICS...
ASSY-SCREW MACHINE (H/S) DB91-00933A HOLDER-WIRE CLAMP DB61-02200A RUBBER DB67-01534A PLATE CONTROL UP DB61-06600A PLATE CONTROL LOW DB61-06713A PLATE CONTROL DB61-06715D COVER CONTROL UP DB63-03378A CASE CONTROL LOW DB61-06714A SPRING DB81-00635A LABEL DB98-34030A HEAT SINK DB62-13007A TERMINAL BLOCK DB65-00274A SAMSUNG ELECTRONICS...
If not, there exists a possibility of fire which can be caused by electric heat in the connecting part. 1,2 : Good 3 Bad : Ring terminal is connected reversely 4 Bad : Not clamped Screw 5 Bad : In the gap between Ring terminal & Screw 6 Bad : Unused Ring Terminal SAMSUNG ELECTRONICS...
The compressor operates in a reverse cycle to remove exterior ice in a HEAT mode, and indoor fan and outdoor fan do not Indoor fan and outdoor fan stop operation operate intermittently for within 20% of the total heater intermittently in a HEAT mode. operation. SAMSUNG ELECTRONICS...
Is theconnection of power cable and Correct thewrong cable. communication cable normal? Is the power is normal? Exchange the PBA of no powerunit (check theLED Lamp) Exchange the indoorunit PBA. Is the communication erroroccurred again? Terminatetheservice. Exchange the outdoorunit PBA. SAMSUNG ELECTRONICS...
Page 90
30°C - 8.31kohm 35°C - 6.94kohm 40°C- 5.83kohm Connect the sensor to PBA connector (6piin) supply power and measure the voltage of #1-#2 in the connector Exchange the indoorPBA Below 0.5V orOver4.5V? Micom erroror connector check Exchange the indoorPBA SAMSUNG ELECTRONICS...
Page 91
Follow the check procedure of Indoorunit Isthe voltage of CN72 #1-#3 over250Vdc power supply error check Is the voltage of CN72 Exchange theIndoorPBA #3-#5 and #3-#6 with in1Vdc~15Vdcduring theoperation? PBA problemorMotorproblem Change the PBA firstand check theoperation Exchange the Fan motor SAMSUNG ELECTRONICS...
Page 92
35 - 6.94kohm - 5.83kkohm Connect the sensor to PBA connector supply power and measure the voltage of "B"in the connector Exchange the Outdoor PBA Below 0.5Vdc or Over 4.5Vdc? Micom error or connector check Exchange the Outdoor PBA SAMSUNG ELECTRONICS...
Page 93
30 -8.31kohm - 6.94kohm - 5.83kohm Connect the sensor to PBA connector supply power and measure the voltage of "B" intheconnector Exchange the Outdoor PBA Below 0.5Vdc or Over 4.5Vdc? Micom error or connector check Exchange the Outdoor PBA SAMSUNG ELECTRONICS...
Page 94
- 138ohm 40 - 115kohm Connect the sensor to PBA connector supply power and measure the voltage of "B"in the connector Exchange the Outdoor PBA Below 0.5Vdc or Over 4.5Vdc? Micom error or connector check Exchange the Outdoor PBA SAMSUNG ELECTRONICS...
Page 95
* Heating mode * * Cooling mode * Is the outdoor temperature over 40 or Is the outdoor temperature under -7 under -30 ? The temperature condition is too poor to operate. Wait until temperature is changed SAMSUNG ELECTRONICS...
Page 96
3) Did you download or insert EEPROM IC, after changing outdoor PBA? 2. Troubleshooting procedure power o and download EEPROM data (or. Insert the service EEPROM IC) Restart after power o Terminate the service Is the error appeared again? Exchange the Outdoor PBA SAMSUNG ELECTRONICS...
Page 97
Is the voltage of "A" #1-#3 over250Vdc power supply error check Is the voltageof "A" #3-#5 and Exchange the Outdoor PBA #3-#6 with in 1Vdc~15Vdc during the operation? PBA problem or Motor problem Change the rst and check the operation Exchange the Fan motor SAMSUNG ELECTRONICS...
Page 98
Is the connection of compressor wire is normal? Connect the comp wire normally Download the EEPROM data Is the restart error occurred again? Terminate the service Is the compressor body and interphase Exchange the Outdoor PBA resistance insulated? Exchange the compressor SAMSUNG ELECTRONICS...
Page 99
Is the connection of compressor wire is normal? Connect the comp wire normally (PBA and Compressor) Is the restart error occurred again? Terminate the service Is the compressor body and Exchange the Outdoor PBA interphase resistance insulated? Exchange the compressor SAMSUNG ELECTRONICS...
Page 100
3) Is there no short or open around "C"? 2. Troubleshooting procedure Restart after power Is the PFC shunt and IPM Exchange the Outdoor PBA shunt resistance value correct? Is the current sensor error appeared again? Terminate the service Exchange the Outdoor PBA SAMSUNG ELECTRONICS...
Page 101
Terminate the service occurred again? Is the position of Correct the sensor position or temperature sensor and sensing exchange the sensor value normal? Is the compressor body and interphase resistance Exchange the Outdoor PBA insulated? Exchange the compressor SAMSUNG ELECTRONICS...
Page 102
Check the fuse open or not? (F001) Exchange the Main PBA Restart after power o . Is the power normal? Check the power source. Is AC power is normal for SMPS? Exchange the Main PBA CN150 : 220Vac~240Vac Check SMPS wire connection SAMSUNG ELECTRONICS...
Page 103
Is the connected louver wire? Does operation start when swing button of the Normal remote control unit pushed? Is the voltage changeable at the pin#2~#5 of CN61, Exchange the PBA CN62, CN63 (louver connector)? Up/Down louver motor is faulty. SAMSUNG ELECTRONICS...
Page 104
2. Troubleshooting procedure If the connector was normally assemble? Check the connector to normally assemble. Have the battery in remote control? Insert the battery in remote control. All the lights out ? Re-check the connector Exchange the display PBA SAMSUNG ELECTRONICS...
Page 105
Does measurement pressure include in ±10% extent of reference pressure? - Discharge temperature and the indoor [Execute the troubleshooting] Check the refrigerant leaks. Check the PCB Relay. - Fill up perfectly refrigerant after re-vacuum. Execute the related trouble- shooting. SAMSUNG ELECTRONICS...
Page 106
Is the OLP over temperature sensor Terminate the service error appeared again? The condition is too poor for air conditioner to operate Wait until OLP temperature is decreased Restart after power off Exchange the Outdoor PBA Exchanged the Compressor SAMSUNG ELECTRONICS...
Page 109
(CN72)? 2. Continuous Operation 2) The fan motor of the indoor . Fan motor connector(CN72) is faulty unit doesn't run 3) The power voltage between . PBA is faulty terminal #3-#5 of the connector(CN72) is 0V SAMSUNG ELECTRONICS...
Page 110
Check the LED lamp display 1) Normal : RED on, GRN blink, YEL off . F1,F2 wire wrong wiring 2) Abnormal . Outdoor PBA is faulty - All o check no power - abnormal display : check error mode SAMSUNG ELECTRONICS...
It occurs when the drain pump is plugged out or it is out of order. Check the power of the drain pump and the position of the drain hose, and when the pump is faulty, contact the drain pump manufacturer. Samsung Electronics do not manufacture drain pumps. So, we are not able to correct the drain pump problems. Smells Whenever the air conditioner is turned on, it irritates my eyes and gives me a headache.
Page 113
Also, the remote controller may mot work under intensive light from a 3-wave length lamp or a neon sign due to the EMI. In this case, take the remote controller closer to the receiver. SAMSUNG ELECTRONICS...
Page 114
There is a cost table. But, our service engineer needs to visit to total up the cost correctly. When you move in, make sure to contact Samsung Electronics Service Center or Authorized Service Agent in advance to streamline the process.
▶ Select Clean. ▶ Canceling Auto clean To cancel Auto clean while it is progressing, that is, while the cleaning progress is being shown, press the (Power) button twice within 20 seconds. NOTE • Canceling Auto clean does not deactivate it. SAMSUNG ELECTRONICS...
Page 116
• If you need to inspect or clean the inside of the heat exchanger on the outdoor unit, contact a local service centre for help. SAMSUNG ELECTRONICS...
Page 117
In operation CAUTION • Take care not to damage the during cleaning. • Do not scrub the air with a hard-bristle brush or another cleaning utensil. • Do not expose the air to direct sunlight when drying it. SAMSUNG ELECTRONICS...
Electric and earth work shall meet the "Electric Facility Technology Standard" and the "Internal Wire Regulation" of the Electric Business Laws. ■ Inspection & Trial Run Upon completion of the tests, you shall make a trial run while you explain the main functions of the air conditioner to finish the installation. SAMSUNG ELECTRONICS...
3 way valve. And mount the service port cap to 3 way valve. Valve stem Stem cap 7) Check for gas leakage. (gas) - At this time, especially check for gas leakage from the 3 way valve's stem nuts, and from the service port cap. (liquid) SAMSUNG ELECTRONICS...
Page 121
• Make sure you do not bend the connection pipes in the middle and store together with the cables. • Move the indoor and outdoor units to a new location. • Remove the mounting plate for the indoor unit and move it to a new location. SAMSUNG ELECTRONICS...
Page 122
• The entire refrigerant shall be recovered safely. • Before starting the process, oil and refrigerant samples shall be taken just in case analysis is required for reuse. • Before starting the process, power supply must be available. This appliance is lled with R-32. SAMSUNG ELECTRONICS...
DA White Grille Wind-Free DA White Grille AIRISE Wind GEO DA White Grille Wind AIRISE DA White Grille ITEM1 ITEM2 12th The integrated code ITEM The existing code the sale area CIS Desription Export (13TH,14TH) Export UNITED KINGDOM Export SAMSUNG ELECTRONICS...