Content s ..........................................................................................................................................................................................................5. Disassambely WIFI ............5-1 ............... 5-1 WIFI CASE ..................................................................................... Samsung Electronics...
Page 3
Operating Instructions and Installation Content s ....................................................................................................................................................................................................................................................................................................................NOZONE/SUMMIT Samsung Electronics...
Page 6
good' sleep Mode good’sleep mode can help you sleep quickly and soundly and wake up refreshed. Catechin Filter Silver Nano Evaporator Deodorizing Filter them with clean,refreshing air. Wi-Fi...
Page 7
Indoor Unit:DB27 WB19 ,Outdoor Unit DB35 WB24 Heating Test Condition Indoor Unit:DB20 WB15 ,Outdoor Unit DB7 WB6 16 ~32 16 ~32 Indoor Cooling Outdoor -10 ~46 -10 ~46 Operation condition range Indoor or less or less Heating -15 ~24 -15 ~24 Outdoor 2-2-1 Samsung Electronics...
Page 8
Indoor Unit:DB27 WB19 ,Outdoor Unit DB35 WB24 Heating Test Condition Indoor Unit:DB20 WB15 ,Outdoor Unit DB7 WB6 16 ~32 16 ~32 Indoor Cooling Outdoor -10 ~46 -10 ~46 Operation condition range or less or less Indoor Heating -15 ~24 -15 ~24 Outdoor 2-2-2 Samsung Electronics...
Page 9
2-3 The Comparative Specifkations of Product 2-3-1 Modified items compared with Basic model NEW MODEL Modifiedpart New contents and characteristic AR*FSSYAWTNEU AR*FSSKABENEU INDOOR Indoor Design changed OUTDOOR chassis changed 2-3-2 New components to be applied Indoor HUMIDITY SENSOR Samsung Electronics...
2-4 Accessory and Option Specifications 2-4-1Accessories Plate-hanger DB61-05014A Remote Control DB93-11489S Batteries for Remote Control 4301-000121 Indoor Unit User’s Manual DB68-03363A Drain Plug DB67-20011A Outdoor Unit Rubber Leg DB73-20134A Indoor ASSY WIFI KIT DB93-09897E Unit Samsung Electronics...
Page 13
I Trip Error / PFC Over Current GAS Leak Error AC Line Zero Cross Signal Out Power ON Reset(1sec) Capacity Miss Match Test Operation at Cooling Mode Test Operation at Heating Mode LED ON LED BLINKING LED OFF Samsung Elec tron i cs 3-2-2...
Page 17
3-4 EEPROM Downloading Method 1) Power off 2) Take off the Cabinet : Check the LED off 3) Connect PC-Download Jig-PBA F1,F2 (2pin) 232 to 485 Converter F1,F2 (2pin)
Page 18
5) Execute the InverterDownload program EEPROM AR09FSSKABEXEU DB82-01402A AR12FSSKABEXEU DB82-01402A AR09FSSYAWTXEU DB82-01404A 5 ) CLICK AR12FSSYAWTXEU DB82-01405A AR09FSFKBWTXEE DB82-01407A 6) Select COM Port and connect AR12FSFKBWTXEE DB82-01408A 7) Open the file 8) Click the Start button and reset the power R eset p ower W aiting d own load D ownload...
,humidity sensor wire. 5) To detach the FRONT-PANEL the main frame, unfasten 2 screw at the bottom.(use + Screw Driver). And pull hooks 6) Take off the FRONT-PANEL, push topside in arrow direction. And lifting up the bottom. 4-1-1 Samsung Electronics...
Page 21
CONTROL IN 1) Unfasten the earth screw.(use + Screw Driver) 2) Detach COVER-CONTROL from the CASECONTROL. 3) Detach the temperature sensor. 4) Loosen MOTOR Wire. 5) Take off the CASE-CONTROL from the main frame. (use + Screw Driver) Samsung Electronics...
Page 22
Operating Instructions and Installation Parts Procedure Remark 1) Detach COVER-CONTROL from the CASECONTROL 2) Loosen the terminal block wires. Caution: The terminal is locking type. So, when you separate terminals, pull pressing the button. Button 4-1-3 Samsung Electronics...
Page 23
Caution: When you separate the connector, pull pressing the locking button. 9) Loosen The Thermistor wire, Humidity sensor wire connector (White 4 Pin, White 3 Pin) Caution: When you separate the connector, pull pressing the locking button. Samsung Electronics 4-1-4...
Page 24
1) Unfasten the screw at the right side. (use + Screw Driver) 2) Unfasten the screw at the left side. (use + Screw Driver) 3) Detach the HOLDER PIPE. 4) Take off the EVAPORATOR from the main frame. (Take care of falling fan) 4-1-5 Samsung Electronics...
Page 25
2) Lift to front and then pull out Fan Motor. 3) Unfasten the screw in the HOLDER-EVAP on the left side of evaporator.(use + Screw Driver) 4) Lift up the evaporator slightly and pull the CROSS-FAN to the left side. Samsung Electronics 4-1-6...
Page 26
4-2 Outdoor Unit (AQV**KBB/AQV**KBBSER)) Detach the Cabinet Upper like the picture. 4-2-1...
Page 27
5) Loosen 2 screw(CCW) on the right side of Cabinet Front. (Use +Screw Driver) 6) Loosen 2 screw(CCW) on the left side of Cabinet Front. (Use +Screw Driver) 7) Loosen 3 screw(CCW) on the front side of Cabinet Front. (Use +Screw Driver) 4-2-2...
Page 30
1) Release Nut at Fan Boss 2) Release 3 screws st Motor Bracket. 3) Detach Motor Wire from the Assy Control Out. 4-2-5...
Page 31
When you separate the connector, pull pressing the locking button. 4) Lift up the right end side of the module and push it to the left. Separate CASE-WIFI TOP from CASE- CASE WIFI BOTTOM. Separate BUTTON WIFI from CASE- Button WIFI BOTTOM. Samsung Electronics...
Page 32
Operating Instructions and Installation 5-1 WIFI CASE Detach ASSY Connector Wire from CASE-WIFI BOTTOM. WIRE * Caution When you separate the connector, pull pressing the locking button. Separate PBA WIFI from CASE-WIFI BOTTOM. Samsung Electronics...
Page 35
5-4 Ass'y Control Out AR09FSSYAWTXEU AR09FSSKABEXEU Samsung Electronics...
Page 40
- L E D B linking ( Interval o f 3 s) : N ot c onnected w ith A P - L E D O FF : N ot c onnected w ith A ir C onditioner 7-3 4 Samsung Electronics...
Page 46
AR*FSSYAWTNEU AR*FSSKABENEU 1. CN61/CN62/CN64 STEP MOTOR 2. CN71 POWER IN 3. CN81 4. CN51 WI-FI MODEM 5. CN91 DISPLAY 6. CN43 TEMPERATURE SENSOR 7. CN21 COMMUNICATION 8. CN42 HUMMIDITY SENSOR 9. CN91 FAN MOTOR 10. CN32...
Page 47
AR*FSSYAWTXEU AR*FSSKABEXEU 3. CN301-485 communication 4.CN451-COMP 5.CN701-EEV 1.4WAY 2.CN051-REACTOR #2 F2 #2 V phase #2 EEV signal #3 U phase #3 EEV signal #4 EEV signal #5,6 12V 6.CN551-INV MICOM DOWNLOAD 7.CN901-BLDC FAN 8.CN201-MAIN MICOM DOWNLOAD 9.CN251-SENSOR #1 OUTDOOR TEMPERATURE #2 GND #3 DISCHARGE TEMPERATURE #4 GND...
Page 49
New Function [ Indoor Terminal Block Safety Device ] 1.Thermal Fuse is installed in Terminal Block as below. (Thermal Fuse is used to prevent PL caused by a defective connection of indoor and outdoor units) 2. Thermal Fuse is opened when internal temperature of Terminal Block goes to a certain point due to Tracking caused by a defective connection of indoor and outdoor units.
Wire connecting the indoor unit terminal blocks 1. Terminal press of Ring terminal shall be set facing up before connecting wire. Is inverted Terminal has been cut. 2. There shall be no empty space between Ring terminal and Screw after Clamp. If not, there exists a possibility of fire which can be caused by electric heat in the connecting part.
Page 51
Main parts Humidity Room sensor temperature sensor Air intake WI-FI MODULE (only apply to K serior) (left and right) SPiindicator (up and down) Display Wi-Fi indicator indicator Remote controller Remote controller receiver receiver indicator Timer / d'light Cool indicator Timer indicator d'light Cool indicator...
Page 53
11-3 ASSY WIFI KIT LED ON:connected with AP & INTERNET LED Blinking(interval of 0.5s):connected with AP but not connected with INTERNET LED Blinking(interval with 3s):not connected with AP LED OFF:not connected with Air Conditioner << WPS >> - WiFi Proteced Setup - A standard for easy and secure wireless network set up and connections 11-3...
Page 54
Remote controller display Power Turn theair conditioner. Mode SettheSPifunction Setone ofthe5 operating modes (seepages 14~16 forinstructions). Smart Saver Quiet Lessenergyusage makes yourspace Reduce noisegeneratedfrom an indoorunit coolbetween thetemperaturerangeof duringoperation. 24°C~30°C. Turbo Air swing Operateinautofanspeed tocoolquickly. Activate/Deactivate air blademovement automatically up and down. Temp + - Increase/Decrease thetemperatureby 1 C.
Page 55
12-1 Cmmunication error Indoor display E101/E102 Communication error(Indoor<- Outdoor display 1min. Time out Comm. Abnormal Communication 1.Checklist : 1) Is the cable between the indoor unit and outdoor unit connected correctly? 2) Isn't the power cable and communication cable cross? 2.
Micom error or connector check Exchange the indoor PBA 1.remove the temprature sensor and check the resistace sensor resistance value as follow: 2.set power on,and check the voltage of the CN43(PIN1,PIN2) the voltage is between 0.5V and 4.5V. Samsung Electronics 12-2-1...
Page 57
Micom error or connector check Exchange the indoor PBA 2.set power on,and check the voltage 1.remove the temprature sensor of the CN43(PIN3,PIN4) and check the resistace the voltage is between 0.5V and 4.5V. sensor resistance value as follow: Samsung Electronics 12-2-3...
Page 58
Connec he wire PBA to louver motor Does op on start when swing n o he remote control unit Normal pushed? Is the voltage changeable a he Exchange the PBA pin#2~#5 of CN61(louver connector)? Up/Down louver motor is faulty. Samsung Electronics 12-2-4...
Page 59
Change the PBA rst and check the opera on Exchange the Fan motor 2.set power on,check the voltage of the CN72(PIN3,PIN5) 1.set power on,check the voltage of the CN72(PIN1,PIN3) the voltage is between 1VDC and 15VDC the voltage is over 250VDC. Samsung Electronics 12-2-5...
Page 60
12-2- utdoor temperature sensor error Outdoor temperature sensor error Outdoor temperature sensor Outdoor display error 1.Checklist : 1) Is the sensor connected correctly? 2) Is the sensor placed correctly? 3) Does the both terminal of sensor satisfy the resistance value in accordance with temperature? 4) Is the resistance value of sensor connection pull-up correct? 2-1.
Page 61
- 5.83kohm Connec he sensor to PBA connector (6piin) supply power and measure the voltage of #5-#6 in the connector Below 0.5Vdc or Over 4.5Vdc? Exchange the Outdoor PBA Micom error or connector check Exchange the Outdoor PBA Samsung Electronics 12-2-7...
Page 62
25 value Connec he sensor to PBA connector (6piin) supply power and measure the voltage of #3-#4 in the connector Below 0.5Vdc or Over 4.5Vdc? Exchange the Outdoor Micom error or connector check Exchange the Outdoor PBA Samsung Electronics 12-2-8...
Page 63
Restart a er power Is the discharge over temperature Terminate the service sensor error appeared again? Download the EEPROM data Is the discharge over temperature Terminate the service sensor error appeared again? Exchange the Outdoor PBA Exchanged the Compressor Samsung Electronics 12-2-9...
Page 64
Is the voltage of CN901 #3-#5 and #3-#6 with in 1Vdc~15Vdc during Exchange the Outdoor PBA the opera on? PBA problem or Motor problem Change the PBA rst and check the opera on Exchange the Fan motor Samsung Electronics 12-2-10...
Page 65
Connec he comp wire normally wire is normal? Download the EEPROM data I th Is the restart error occurred again? Terminate the service Is the compressor body and Exchange the Outdoor PBA interphase resistance insulated? Exchange the compressor Samsung Electronics 12-2-11...
Page 66
(PBA and l? ( Connec he comp wire normally Compressor) Is the restart error occurred again? Terminate the service Is the compressor body and Exchange the Outdoor PBA interphase resistance insulated? Exchange the compressor Samsung Electronics 12-2-12...
Page 67
Is the compressor body and Is the compressor body and Exchange the Outdoor PBA Exchange the Outdoor PBA interphase resistance insulated? interphase resistance insulated? Exchange the compressor Samsung Electronics 12-2-13...
Page 68
Exchange the Outdoor PBA Exchange the Outdoor PBA mode? Normal range (0.2Vdc~2.8Vdc) mode? mode? Is the reactor insula on damaged? Is the reactor insula on damaged? Exchange the Outdoor PBA Exchange the Outdoor PBA Exchange the Reactor Exchange the Reactor Samsung Electronics 12-2-14...
Page 69
Is the DC_link sensing voltage(R104) is normal in Exchange the Outdoor PBA Exchange the Outdoor PBA mode? Normal range (0.2Vdc~2.8Vdc) mode? I th Is the reactor insula on damaged? Exchange the Outdoor PBA th O td Exchange the Reactor Samsung Electronics 12-2-15...
Page 70
Is the conn on cable for the on cable for the compressor and power terminal compressor and power terminal Correc he cable conn Correc he cable conn normal? normal? Exchange the Outdoor PBA Exchange the Outdoor PBA Samsung Electronics 12-2-16...
Page 71
Exchange the Outdoor PBA resistance value correct? resistance value correct? Is the current sensor error Is the current sensor error Terminate the service Terminate the service appeared again? appeared again? Exchange the Outdoor PBA Exchange the Outdoor PBA Samsung Electronics 12-2-17...
Page 72
Fastening the screw (4 screws) (4 screws) Check the fan conne Check the fan conne Is the fan oper Is the fan oper n normal? n normal? Change the Fan motor Change the Fan motor Exchange the Outdoor PBA Samsung Electronics 12-2-18...
Page 73
Is the compressor body and Is the compressor body and Exchange the Outdoor PBA Exchange the Outdoor PBA interphase resistance insulated? interphase resistance insulated? Exchange the compressor Samsung Electronics 12-2-19...
Page 74
EEPROM data power o and download EEPROM data (or. Inser he service EEPROM IC) (or. Inser he service EEPROM IC) Restart a er power o Terminate the service Is the error appeared again? Exchange the Outdoor PBA Samsung Electronics 12-2-20...
Page 75
1) Check the power condition at customer's house (Is there any power noise?) 2) Have been there power failure? 2. Troubleshooting procedure Restart Restart er power o er power o Is the AC line zero cross signal error Terminate the service appeared again? Exchange the Outdoor PBA Samsung Electronics 12-2-21...
Page 76
Is the outdoor temperature under - or under -30 ? or under -30 ? The temperature condi on is too poor to operate. The temperature condi on is too poor to operate. Wait un l temperature is changed Samsung Electronics 12-2-22...
Page 77
Is the capacity miss match error Is the capacity miss match error Terminate the service Terminate the service appeared again? appeared again? Exchange the Outdoor PBA Exchange the Outdoor PBA Exchange the Indoor PBA Exchange the Indoor PBA Samsung Electronics 12-2-23...
Page 78
Is the of ef ige a t of ef ige a t Fill p the ef ige a t. Fill p the ef ige a t. mal? mal? e the I e the I e the e the Samsung Electronics 12-2-24...
Page 79
Check the display board Is the DC_link voltage normal? Is the DC_link voltage normal? Exchange the PBA Exchange the PBA C102(+)-C101(-) :270Vdc~320Vdc C102(+)-C101(-) :270Vdc~320Vdc Is the SMPS is normal? Exchange the PBA IC102 : 12Vdc-GND-5Vdc Exchange the PBA Samsung Electronics 12-2-25...
Page 80
1. Check if you pulled out the AC power plug when you eliminate the PCB or front panel 2. Don't hold the PCB side not impose excessive force on it to eliminate the PCB 3. Don’t pull the lead wire but hold the whole housing to connect or disconnect a connector to the PCB 4.
Page 81
1. Fan speed(high) 2) The fan motor of the indoor unit doesn't run Fan motor connector(CN72) is faulty 2. Con nuous Opera on 3) The power voltage between terminal PBA is faulty #1~#3 of the connector(CN72) is 0V Samsung Electronics 12-3-4...
12-4 ASSY WIFI KIT Inspection Method << Status LED Indication >> 1. LED ON : Connected with AP & INTERNET 2. LED Blinking (Interval of 0.5s) : Connected with AP but not connected with INTERNET 3. LED Blinking (Interval of 3s) : Not connected with AP 4.
Page 83
12-4 ASSY WIFI KIT Inspection Method 12-4-2 Status-LED Blinking with interval 3s Wireless AP Power Connect Indoor unit and ASSY WIFI KIT on?? Retry WiFi setting with Smart Phone Is the problem Terminate the service occurred again? Exchange ASSY WIFI KIT Is the problem Terminate the service occurred again?
Page 84
12-4 ASSY WIFI KIT Inspection Method 12-4-3 Status-LED Blinking with interval 0.5s Check Wireless AP whether connect to internet or not (Connect to www.samsung.com with Smart Phone) Internet OK? Contact to Internet service provider Contact to Wireless AP maker 12-4...
Page 85
CONTROLLER IC-MCU HEAT EXCHANGER SENSOR DISPLAY PART · H/V BLADE CONTROL · INDOOR FAN MOTOR CONTROL · DISPLAY ROOM TEMPERATURE SENSOR · OUTDOOR COMMUNICATION - TIMER · TEMPERATURE CONTROL - GOODSLEEP · HUMIDITY CONTROL HUMIDITY SENSOR · TIMER - COMFORT CARE ·...
Note : Please measure the refrigerant pressure after the air conditioner operates on testing cooling mode during more than 10 minutes. Indoor Temp. Variation : 20°C ~ 32°C Outdoor Temp. Variation : -5°C ~ 45°C Low Refrigeran t Pressur e Distributio n AR09FSSYAWT AR09FSSYAWT AR09FSSKABE AR12FSSYAWT AR12FSSKABE Outdoor Temperature[ ] Samsung Electronics 14-2...
Page 93
Cleaning the indoor unit when needed. when Contact the service center clean the indoor unit Since the panel of the scratched, you andremove debris cloth scratches. on the using not clean the alkaline Do not use sulfuric acid, acid, kerosene (such as thinner, acetone etc.) to clean the of the product...
Cleaning the air conditioner you and slide it down. Open the panel and put the Full HD filter out. Clean the Full HD filter with a vacuum cleaner or soft brush. If dust is too heavy, rinse it with running water. Insert the Full HD filter back in its original Dry the Full HD filter in a ventilated area.
15 WORKING RANGE 15-1. POWER SUPPLY 198V ~ 264V Working Voltage Within a 3% Deviation from Each Voltage at the Main Terminal of Voltage Imbalance Outdoor Unit Higher than 85% of the Rated Voltage Starting Voltage 15-2. Working Range 15-2-1. MULTIZONE/MONOZONE/SUMMIT Applicable models: SUMMIT...