Fixing the indoor unit in place
Perform the following work on the area where gas leak test was done priory.
After checking for gas leaks in the system, insulate the pipe, hose and cables.
Then place the indoor unit on the installation plate.
1. To minimise condensation problems, wrap foam insulation (as shown in the
figure) on a part without insulation on the end of the pipes.
2. Wind the pipe, assembly cable and drain hose with vinyl tape.
3. Place the bundle (the pipe, assembly cable and drain hose) in the lower part
of the indoor unit carefully so it does not project from the rear of the indoor
unit.
4. Hook the indoor unit to the installation plate and move the unit to the right
and left until it is securely in place.
• M ake sure pipe does not move when you install the indoor unit on
an installation plate.
5. Wrap the rest of the pipe with vinyl tape.
6. Attach the pipe to the wall using clamps (optional).
Fixing the outdoor unit in place
Install the outdoor unit in level on a stable base to help avoid the generation of noise and
vibration, especially when installing the unit close to a neighbor.
If you install the outdoor unit in a place exposed to strong winds or at a height, fix it to an
appropriate support (wall or ground).
1. Place the outdoor unit as indicated on the top of the unit to let the discharged air
out properly.
2. Fix the outdoor unit in level to an appropriate support using anchor bolts.
3. If the outdoor unit is exposed to strong winds, install shield plates around the
outdoor unit so that the fan can operate correctly.
• Secure the rubber leg to help prevent the generation of noise and vibration.
Outdoor unit installed on the wall by rack
• E nsure the wall will be able to suspend the weight of rack and
outdoor unit;
• I nstall the rack close to the column as much as possible;
• I nstall proper grommet in order to help reduce noise and residual
vibration transferred by outdoor unit towards wall.
Australia_A3050_IB&IM_EN_03979A-03.indd 53
Connecting wires
Soft rubber designed to cut off
vibration from rack to wall.
(not supplied with product)
English-53
Insulation
Pipes
Installation
plate
Connecting
pipes
Vinyl tape
Drain hose
'X' mm
Rubber leg
Model
X
Y
AR09/12CWK
602
310
AR09/12DUR
AR09/12BWK
612
317
AR09/12CUR
660
340
18/24
690
403
30
Designed to cut off residual vibration
from outdoor unit to rack.
(not supplied with product)
2013-10-28 17:04:02