hit counter code
Table of Contents

Advertisement

Quick Links

user & installation manual
user & installation manual
This manual is made with 100% recycled paper.
This manual is made with 100% recycled paper.
NA_BETTER_A3050_IB&IM_EN_DB68-05012A.indd 1
Air Conditioner
Air Conditioner
imagine
the possibilities
imagine
the possibilities
Thank you for purchasing this Samsung product.
Thank you for purchasing this Samsung product.
To receive more complete service, please
register your product at
www.samsung.com/register
AR✴✴JV5D✴✴ Series
AR✴✴FSSSBWK Series
AR✴✴FSSSCUR Series
11/20/2014 3:17:04 PM

Advertisement

Table of Contents
loading

Summary of Contents for Samsung AR**JV5D series

  • Page 1 This manual is made with 100% recycled paper. imagine the possibilities imagine the possibilities Thank you for purchasing this Samsung product. Thank you for purchasing this Samsung product. To receive more complete service, please register your product at www.samsung.com/register NA_BETTER_A3050_IB&IM_EN_DB68-05012A.indd 1...
  • Page 2 For more information on safe disposal and recycling visit our website www.samsung.com/in or contact our Helpline numbers - 18002668282, 180030008282 English-2 NA_BETTER_A3050_IB&IM_EN_DB68-05012A.indd 2...
  • Page 3: Table Of Contents

    Contents Preparation Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Checking before use .
  • Page 4: Safety Precautions

    If you have any questions, call your nearest contact center or find help and information online at www.samsung.com. Important safety symbols and precautions: Hazards or unsafe practices that may result in severe WARNING personal injury or death.
  • Page 5 Do not install this appliance near a heater, inflammable material. Do not install this appliance in a humid, oily or dusty location, in a location exposed to direct sunlight and water (rain drops). Do not install this appliance in a location where gas may leak. ...
  • Page 6 Safety precautions FOR POWER SUPPLY CAUTION When not using the air conditioner for a long period of time or during a thunder/lightning storm, cut the power at the circuit breaker.  Failing to do so may result in electric shock or fire. WARNING FOR USING If the appliance is flooded, please contact your nearest service center.
  • Page 7 Do not insert your fingers or foreign substances into the outlet when the air conditioner is operating.  Take special care that children do not injure themselves by inserting their fingers into the product. Do not touch the air flow blade with your hands or fingers during the heating operation.
  • Page 8 Safety precautions CAUTION FOR USING Do not place objects or devices under the indoor unit.  Water dripping from the indoor unit may result in fire or property damage. (example electrical appliances) Check that the installation frame of the outdoor unit is not broken at least once a year.
  • Page 9 This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
  • Page 10: Checking Before Use

    Checking before use Operation ranges The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use. Mode Indoor temperature Outdoor temperature Indoor humidity Cooling 16 ˚C ~ ˚C 16 ˚C ~ 52 ˚C Relative humidity 80% or less 18 ˚C ~ 32 ˚C...
  • Page 11: Checking The Name Of The Parts

    Checking the name of the parts Your air conditioner may slightly look different from illustration shown below depending on your model. Main parts Room temperature sensor Air filter Air intake Virus Doctor Lamp Virus Doctor Air flow blade Air flow blade (up and down) (left and right) Display...
  • Page 12: Checking The Remote Controller

    Checking the remote controller • Point the remote controller towards the remote controller receiver of the indoor unit. • W hen you properly press the button on the remote controller, you will hear beep sound from the indoor unit and a transmit indicator( ) appears on the remote controller display. Remote controller buttons Vertical air swing Activate/Deactivate vertical air flow blade movement automatically Power Mode Turn on/off the air Set one of the 5 operating modes conditioner Temp + –...
  • Page 13: Remote Controller Display

    Remote controller display Transmit indicator Operation mode Low battery indicator indicator Set temperature/ Time (for Fan speed indicator Timer option) indicator good'sleep indicator Vertical/Horizontal air swing indicator Options indicator This function is not available in this model. Settings indicator • M ake sure that the water does not get to the remote controller. • H eat mode/d'light Cool function is displayed on the remote controller display but not supported in this model.
  • Page 14: Basic Function

    Basic function Basic operation is an operation mode that can be selected by pressing the Mode button. auto In Auto mode, the air conditioner will automatically set the temperature and fan speed depending on the room temperature . Cool In Cool mode, the air conditioner will cool your room . You can adjust the temperature and the fan speed to feel cooler in hot season .
  • Page 15 Basic function Press the button to turn on the air conditioner. Press the button to set the operating mode. • Each time you press the Mode button, the mode will change in order of Auto, Cool, Dry, Fan and Heat. Press the button to set the desired fan speed. Auto (Auto) Cool...
  • Page 16: Adjusting The Air Flow Direction

    adjusting the air flow direction This function will allow you to adjust the air flow direction vertically and/or horizontally . Press the button to make air flow blades vertically and/or horizontally. Vertical air flow Horizontal air flow f To keep the air flow direction in a constant direction, press the button again .
  • Page 17: Setting The On/Off Timer

    Setting the On/Off timer Setting the On timer When the air conditioner is off; 1 . Press the Timer button . 2 . Press the button until (On) indicator starts to blink . 3 . Press the SET button to set the On timer . - (On) indicator will keep blinking and you can set the time .
  • Page 18: Setting The Off Timer

    Setting the On/Off timer Setting the Off timer When the air conditioner is on; 1 . Press the Timer button . 2 . Press the button until (Off) indicator starts to blink . 3 . Press the SET button to set the Off timer . - (Off) indicator will keep blinking and you can set the time .
  • Page 19: Mode

    mode For a comfortable sleep, the air conditioner will operate in 3 stages in order of Fall asleep  Sound sleep  Wake up stage . When the air conditioner is operating in Cool/Heat mode; 1 . Press the Timer button . 2 .
  • Page 20: 2-Step Cooling Function

    2-Step cooling function 2-Step Cooling function will set the air conditioner to cool the room quickly to reach the set temperature when the indoor temperature is higher than the set temperature, and then the air conditioner will automatically operate in Dry mode when indoor temperature reaches set temperature .
  • Page 21: Using The Fast Function

    using the Fast function You can set the Fast function to provide fast and powerful cooling/heating. When the air conditioner is operating in Cool/Heat mode; 1 . Press the Options button . 2 . Press the button until (Fast) indicator starts to blink . 3 .
  • Page 22: Using The Single User Function

    using the Single user function This function will reduce the energy usage while the air conditioner is operating in Cool/Heat mode. When the air conditioner is operating in Cool/Heat mode; 1 . Press the Options button . 2 . Press the button until (Single user) indicator starts to blink .
  • Page 23: Using The Quiet Function

    using the Quiet function You can reduce the noise generated from an indoor unit during Cool/Heat mode. When the air conditioner is operating in Cool/Heat mode; 1 . Press the Options button . 2 . Press the button until (Quiet) indicator starts to blink . 3 .
  • Page 24: Using The Virus Doctor Function

    using the Virus Doctor function This function will produce positive ions and supply them into the airflow. When the air conditioner is operating; 1 . Press the Options button . 2 . Press the button until ( ) indicator starts to blink . 3 .
  • Page 25: Checking The Power Consumption

    Checking the power consumption This function will display the amount of electricity consumed by operating the air conditioner. When the air conditioner is operating; 1 . Press the Settings button . 2 . Press the button until (Usage) indicator starts to blink . 3 .
  • Page 26: Setting The Beep Sound

    Setting the Beep sound Beep sound from the indoor unit can be muted. 1 . Press the Settings button . 2 . Press the button until (Beep) indicator starts to blink . 3 . Press the SET button to mute the beep sound . resetting the Filter clean reminder When Filter clean reminder ( ) lights up on the indoor unit display, clean the filter and reset the reminder by following this instruction.
  • Page 27: Cleaning The Air Conditioner

    Cleaning the air conditioner • Make sure to turn off the power of the indoor unit and cut-off the power supply before cleaning the air conditioner. CAUTION Cleaning the indoor unit Wipe the surface of the unit with a slightly damp micro fiber cloth when ...
  • Page 28 Cleaning the air conditioner Removing the Air filter There is a hole on the bottom right side of the filter. Air filter Put your finger in that hole to get a grip on the filter and slightly push it up to release the hooks from the bottom side.
  • Page 29 Cleaning the air conditioner reassembling the air filter 1 . Put the filter on the main body and insert the hooks which are Air filter in the top of the Air filter into the main body . ➀ 2 . There’s one hook in both side of the filter, press the surface of the Air filter softly and get the hooks into the main body .
  • Page 30: Maintaining The Air Conditioner

    maintaining the air conditioner If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best condition. 1. Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and cut-off the power supply.
  • Page 31: Troubleshooting

    Troubleshooting Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses. PROBLEM SOLUTION The air conditioner • Check power status and then operate the air conditioner again. does not work at all. • P lug in or switch on the circuit breaker and then operate the air conditioner again. • Ensure Isolator is switch on. • C heck if you have set the Off Timer. Operate the air conditioner again by pressing the Power button.
  • Page 32 PROBLEM SOLUTION Fan speed • C heck if you have selected Auto/Dry/Fast/ mode. In adjustment is not these mode, fan speed is set to Auto and you cannot adjust the fan working. speed. Remote controller is • Check if your batteries are depleted. not working. • Make sure nothing is blocking your remote controller sensor. • C heck that there are strong lighting apparatus near the air conditioner.
  • Page 33: Safety Precautions

    In order to help prevent electric shocks, fires or injuries, always stop the unit, disable the protection switch and contact  SAMSUNG’s technical support if the unit produces smoke, if the power cable is hot or damaged or if the unit is very noisy. Always remember to inspect the unit, electric connections, refrigerant tubes and protections regularly. These operations ...
  • Page 34: Choosing The Installation Location

    Installing the unit IMPORTANT: W hen installing the unit, always remember to connect first the refrigerant tubes, then the electrical lines. Always disassemble the electric lines before the refrigerant tubes. Upon receipt, inspect the product to verify that it has not been damaged during transport. f If the product appears damaged, DO NOT INSTALL it and immediately report the damage to the carrier or retailer (if the installer or the authorized technician has collected the material from the retailer.) After completing the installation, always carry out a functional test and provide the instructions on how to operate the air f...
  • Page 35: Outdoor Unit

    Choosing the installation location Outdoor Unit Where it is not exposed to strong wind  Well ventilated and dustless places  Where possible keep out of sunlight and rain  Where neighbors are not annoyed by operation sound or hot air f Solid wall or support that prevents vibration and is strong enough to hold the product weight ...
  • Page 36 Space Requirements for Outdoor Unit When installing 1 outdoor unit  Figure Description Top view Side view Air intake Air outlet Air intake Air outlet Air flow direction  (Unit : mm)  When the air outlet is opposite  When the air outlet is towards the ...
  • Page 37: Accessories

    Choosing the installation location (Unit : mm)  When the walls are blocking front and the rear side of the outdoor  When the upper part of the outdoor unit and units the air outlet is opposite the wall 300 or more 600 or more 600 or more ...
  • Page 38: Optional Accessories

    • T he flare nuts are attached to the end of each pipe of an evaporator or a service port. Use the nuts when connecting the pipes. • T he wire assembly cable is optional. If it is not supplied, use the standard cable. • T he drain plug and rubber leg are only included when the air conditioner is supplied without the assembly pipe as seen in the picture below. Optional accessories Insulated Assembly Pipe, Insulated Assembly Pipe, Insulated PE T3 Foam Tube Drain Hose, Vinyl Tapes (2) Ø9.52 mm x 4 m (1) Ø12.70 mm x 4 m (1)
  • Page 39 1. Disassemble the cover panel as described in page 40~41. 2. Remove the Hanger plate from the indoor unit. (1) Unscrew 2 screws that fixes the Hanger plate to the indoor unit. (2) Push the hooks (on the bottom part of the indoor unit) up to release the installation plate from the hooks that holds it. (3) Pull the installation plate to release it completely from the indoor unit.
  • Page 40: Disassembling/Assembling The Cover Panel For Indoor Unit Installation

    Disassembling/assembling the Cover panel for indoor unit installation Please scan this QR code for detail video of indoor unit installation . In order to install the indoor unit, you must disassemble the cover panel first . Please proceed following instructions to disassemble and assemble the cover panel . Hooks (on the cover panel) may get damaged if you apply excessive force as you disassemble and assemble the cover panel .
  • Page 41 Disassembling/assembling the Cover panel for indoor unit installation f Removing the hooks on the side f Removing the hooks on the central part ① ② ①  Caution (fragile)  Caution (fragile) - Gently press the both side of the cover - Use both hands panel inwards (①) and release the - Release each hook by pushing it up at an angle .
  • Page 42: Connecting The Assembly Cable

    Connecting the assembly cable Cable specification Model Power cable Interconnection cable Type GL 3G x 1.0 mm², H07RN-F 3G x 2.5 mm², H07RN-F 20 A 12 2 x 0.75 mm², H05RN-F 3G x 1.0 mm², H07RN-F 3G x 2.5 mm², H07RN-F 25 A 18 2 x 0.75 mm², H05RN-F • C onnect the power cable to the auxiliary circuit breaker. If every pole fails to connect to the power supply, it must be incorporated in a wire with a contact opening of ≥...
  • Page 43 Connecting the assembly cable  When you install the unit, make first refrigerant connections and then electrical connections. Connect the air conditioner to grounding system before performing the electrical connection. If unit is uninstalled, first disconnect electrical cables, then refrigerant connections. If the outdoor unit is more than 5 meters away from the indoor unit, you must extend the cable.
  • Page 44: Installing And Connecting The Assembly Pipe Of The Indoor Unit

    Installing and connecting the assembly pipe of the indoor unit Connect indoor and outdoor units with field-supplied copper pipes by means of flare connections. Use insulated seamless refrigeration grade pipe only, (Cu DHP type according to ISO1337), degreased and deoxidized, suitable for operating pressures of at least 4200 kPa and for burst pressure of at least 20700 kPa.
  • Page 45: Evacuating The Indoor Unit

    Evacuating the indoor unit The indoor unit is supplied with inert gas (nitrogen). Before installing the unit, check if nitrogen gas flows out of indoor unit. If this one isn’t true, DO NOT INSTALL THE UNIT since leakage could be inside the indoor unit. 1.
  • Page 46: Installing And Connecting The Drain Hose Of The Indoor Unit

    Cutting or extending the pipe 5. Check if you flared the pipe correctly (see examples of incorrectly flared pipes below). Correct Damaged Uneven Inclined Cracked Surface Thickness 6. Align the pipes to connect them easily. Tighten the flare nuts first with your hands, and then with a torque wrench, applying the following torque: Torque Flare nut...
  • Page 47: Drain Hose Installation

    Installing and connecting the drain hose of the indoor unit After completing the installation of the drain hose, pour water into the drain pan to check whether the hose is well less Ditch drained. Keep a clearance of at least Do not place the end of the 5 cm between the end of the drain hose in a hollow.
  • Page 48: Changing Direction Of The Drain Hose

    Installing and connecting the drain hose of the indoor unit 6. Pass the drain hose under the refrigerant pipe, keeping the drain hose tight. Shield 7. Pass the drain hose through the hole in the wall. Check if it slants downwards as seen in the picture.
  • Page 49: Evacuating The Connected Pipes

    Evacuating the connected pipes The outdoor unit is loaded with sufficient R-410A refrigerant. Do not vent R-410A into atmosphere: it is a fluorinated greenhouse gas, covered by Kyoto Protocol, with a Global Warming Potential (GWP) = 2088. You should evacuate the air in the indoor unit and in the pipe. If air remains in the refrigerant pipes, it affects the compressor. It may cause reduction of cooling capacity and malfunction.
  • Page 50: Adding Refrigerant

    Evacuating the connected pipes Adding Refrigerant Add refrigerant charge according to table below: If you use a pipe longer than 5 m, Model ‘A’ g of refrigerant R-410A must be added for each extra meter. 12/18 If you use a pipe shorter than 5 m, The evacuating time is normal. Refer to the Service Manual for further details.
  • Page 51 Evacuating the connected pipes Important information regulation regarding the refrigerant used This product contains fluorinated greenhouse gases covered by the Kyoto Refrigerant type GWP value Protocol. R-410A 2088 Do not vent gases into the atmosphere.  GWP=Global Warming Potential 1. Please fill in with indelible ink, Contains fluorinated greenhouse gases ...
  • Page 52: Performing The Gas Leak Tests

    Performing the gas leak tests Make sure to check for gas leaks before completing the installation process (connecting the assembly pipe and hose between indoor unit and outdoor unit, insulating the cables, hose and pipe, and fixing the indoor unit to the installation plate). Test part for outdoor unit Test part for indoor unit Tightening torque for body cap...
  • Page 53: Fixing The Indoor Unit In Place

    Fixing the indoor unit in place Perform the following work on the area where gas leak test was done priory. After checking for gas leaks in the system, insulate the pipe, hose and cables. Insulation Then place the indoor unit on the installation plate. 1.
  • Page 54: Smart Install Mode

    Smart Install mode This model supports Smart Install mode which checks installation status to find out if there is any problems with any of the functions . Execute Smart Install mode after installation . 1 . Check the installation status of the air conditioner . 1) Check the power supply, service valve (if it's open), power cable of the indoor and outdoor unit and amount of additional refrigerant required for pipe extension .
  • Page 55 2) Smart Install mode in progress • 88 Display : Progress will be displayed in 0~99 . • LED Display : Indicator on the indoor unit display will blink in sequence and then all indicators will blink . (This will be repeated .
  • Page 56: Final Check And Trial Operation

    Final check and trial operation To complete the installation, perform the following checks and tests to ensure that the air conditioner operates correctly. Check the followings: • Strength of the installation site • Tightness of pipe connection to detect gas leak • Electric wiring connection • Heat-resistant insulation of the pipe • Drainage • Grounding conductor connection • Correct operation (follow the steps below) 1. Press the Power button and check the following: The indicator on the indoor unit lights up.
  • Page 57: How To Connect Your Extended Power Cables

    How to connect your extended power cables Items to prepare (compressor and insulation tape should be prepared by an installation technician.) Tools Crimping pliers Connection sleeve (mm) Insulation tape Contraction tube (mm) Spec MH-14 20xØ7.0(HxOD) Width 18 mm 50xØ8.0(LxOD) Shape 1.
  • Page 58 English-58 NA_BETTER_A3050_IB&IM_EN_DB68-05012A.indd 58 11/20/2014 3:18:38 PM...
  • Page 59 English-59 NA_BETTER_A3050_IB&IM_EN_DB68-05012A.indd 59 11/20/2014 3:18:38 PM...
  • Page 60 QUESTIONS OR COMMENTS? COUNTRY CALL OR VISIT US ONLINE AT 1800 3000 8282 - Toll Free www.samsung.com/in/support INDIA 1800 266 8282 - Toll Free This product is RoHS compliant DB68-05012A-00 NA_BETTER_A3050_IB&IM_EN_DB68-05012A.indd 60 11/20/2014 3:18:38 PM...

This manual is also suitable for:

Ar12jv5n seriesAr18jv5n seriesAr24jv5n series

Table of Contents