Page 2
(excluding ductless systems) must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit www.energystar.gov. Qualified model list (Indoor/Outdoor): AR09KSWSJWKN/AR09KSWSJWKX, AR12KSWSJWKN/AR12KSWSJWKX, AR18KSWSJWKN/AR18KSWSJWKX, AR24KSWSJWKN/AR24KSWSJWKX, AR09KSWDHWKN/AR09KSWDHWKX, AR12KSWDHWKN/AR12KSWDHWKX English-2 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 2 2015/10/12 15:42:53...
If you have any questions, call your nearest contact center or find help and information online at www.samsung.com. Important safety symbols and precautions: Hazards or unsafe practices that may result in severe WARNING personal injury or death.
Page 5
Install a Isolation Switch next to the Air Conditioner (but not on the panels of the Air Conditioner)and circuit breaker dedicated to the air conditioner. Failing to do so may result in electric shock or fire. Fix the outdoor unit firmly so that the electric part of the outdoor unit is not exposed.
Page 6
Safety precautions WARNING FOR POWER SUPPLY When the circuit breaker is damaged, contact your nearest service center. Do not pull or excessively bend the power wiring. Do not twist or tie the power line. Do not hook the power line over a metal object, place a heavy object on the power line, insert the power line between objects, or push the power line into the space behind the appliance.
Page 7
Do not touch the circuit breaker with wet hands. This may result in electric shock. Do not turn the air conditioner off using the circuit breaker while it is operating. Turning the air conditioner off and then on again with the circuit breaker may cause a spark and result in electric shock or fire.
Page 8
Safety precautions Do not attempt to repair, disassemble, or modify the appliance yourself. Do not use any fuse (such as cooper, steel wire, etc.)other than the standard fuse. Failing to do so may result in electric shock, fire, problems with the product, or injury.
Page 9
Do not use this air conditioner to preserve precision equipment, food, animals, plants or cosmetics, or for any other unusual purposes. This may result in property damage. Avoid directly exposing humans, animals or plants from the air flow from the air conditioner for long periods of time. This may result in harm to humans, animals or plants.
Through the Smart install function, installer can check if the installation was completed correctly. If the installation was not done correctly, error indicator will turn on the indoor unit display. Therefore user will know if the installation was done correctly. English-10 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 10 2015/10/12 15:42:55...
Options or Settings menu to make a selection. Options or Settings button again, then the most recently selected item will blink and you may simply cancel it by pressing the SET button while selected item is blinking. English-12 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 12 2015/10/12 15:42:55...
Page 13
3. Close the cover by place it back to its original position. When you do not use the remote controller for long time, You should hear click sound when the cover is locked properly. remove the batteries from the remote controller and store it. English-13 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 13 2015/10/12 15:42:56...
Since the air conditioner heats the room by taking heat energy from outdoor air, the heating capacity may decrease when outdoor temperature is extremely low. Use an additional heating appliance in combination with the air conditioner if you feel the air conditioner heats insufficiently. English-14 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 14 2015/10/12 15:42:56...
Page 15
You can adjust the desired temperature by 1 °F within the range of 61°F~86°F(16°C~30°C). Press the button to set the desired fan speed. Auto (Auto) Cool (Auto), (Low), (Med), (High), (Turbo) (Auto) (Low), (Med), (High), (Turbo) Heat (Auto), (Low), (Med), (High), (Turbo) English-15 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 15 2015/10/12 15:42:57...
Move the blade left or right to keep the air flow direction in a constant position you prefer. direction should only be done when the unit is turned off completely. There is a potential risk of personal injury when the unit is mishandled. English-16 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 16 2015/10/12 15:42:58...
On timer is cancelled, (On) indicator on the remote controller will remain displayed. When the On timer is set while the air conditioner is off, Timer indicator ( ) will be displayed and remain on until the On timer turns on. English-17 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 17 2015/10/12 15:42:59...
Page 18
2 hours and then turn off automatically. from the moment it was turned off. Set time for the On timer and the Off timer should be different from each other. English-18 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 18 2015/10/12 15:43:00...
5 hours, Wake up stage will begin when 1 hour is remaining in the operation time and the air conditioner will stop automatically. When the On timer and the function is set simultaneously, the air conditioner will only apply the function that was set later. English-19 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 19 2015/10/12 15:43:01...
- (2-Step) (2-Step) indicator will be displayed on the remote controller display and 2-Step Cooling function will begin. Press the Options button Press the or Options button to Cancel make the (2-Step) indicator blink and press the SET button. Remote controller display English-20 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 20 2015/10/12 15:43:02...
Set temperature can be adjusted, but fan speed cannot be adjusted. If the Comfort function is selected while 2-Step Cooling/Fast/Single user/ Quiet/ function is on, corresponding function will be cancelled. Remote controller display English-21 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 21 2015/10/12 15:43:03...
You can adjust the set temperature by 1 °F within the range of in Cool mode and 61°F~86°F (16°C~30°C) in Heat mode. (Auto), (Low), (Med), (High), (Turbo) can be selected. Vertical/Horizontal air swing can be selected. English-22 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 22 2015/10/12 15:43:04...
Vertical/Horizontal air swing can be selected. Remote controller display Quiet function is only available in Cool/Heat mode. If the Quiet function is selected while 2-Step Cooling/Fast /Comfort/ Single user/ function is on, corresponding function will be cancelled. English-23 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 23 2015/10/12 15:43:05...
3. Press the SET button to mute the beep sound. - 3 seconds after setting Beep sound function, (Beep) indicator on the remote controller display will disappear and Beep sound function will begin. English-24 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 24 2015/10/12 15:43:06...
- 3 seconds after setting Filter clean reminder function, (Filter Reset) indicator on the remote controller display will disappear and ( ) indicator on the indoor unit display will disappear. Indoor unit display English-25 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 25 2015/10/12 15:43:07...
WiFi function will begin. 2. Press the Settings button to set the WPS function. - Press the Settings button for 4 seconds. ) will blink first, then disappears and WPS function will begin. Remote controller display English-26 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 26 2015/10/12 15:43:07...
When dust accumulates on the heat exchanger, it may decrease cooling performance. Therefore, clean it regularly. Spray water to clean the dust. your own, contact service center. Heat exchanger outdoor unit heat exchanger. CAUTION (Illustration may differ slightly depending on the models) English-27 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 27 2015/10/12 15:43:08...
Page 28
If dust is too heavy, rinse it with running water. Insert the Air filter back in its original position. Dry the Air filter in a ventilated area. conditions. In dusty area, clean it once a week. well-ventilated area. English-28 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 28 2015/10/12 15:43:08...
Page 29
2. There’s one hook in both side of the filter, press the surface of the Air filter softly and get the hooks into the main body. 3. Press the bottom of the filter lightly to securely fix the main body. English-29 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 29 2015/10/12 15:43:09...
(1) The described operations should be performed more frequently if the area of installation is very dusty. CAUTION (2) These operations must always be performed by qualified personnel. For more detailed information, see the installation part in the manual. English-30 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 30 2015/10/12 15:43:09...
Air flow adjustment mode. In cool mode, you mode is is not working. cannot adjust the air flow direction. (If the operating in Heat mode, you can adjust the air flow direction.) English-31 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 31 2015/10/12 15:43:09...
Page 32
It is normal. Smoke is generated from the outdoor operation from outdoor heat exchanger during Heat mode in unit. winter. Water is dropping from the outdoor unit It is normal. piping connection. English-32 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 32 2015/10/12 15:43:09...
In order to help prevent electric shocks, fires or injuries, always stop the unit, disable the protection switch and contact SAMSUNG’s technical support if the unit produces smoke, if the power cable is hot or damaged or if the unit is very noisy.
Safety precautions To help prevent injury when accidentally touching the indoor unit fan, install the indoor unit at least 6'(2.5m) above the floor. The air conditioner should be used only for the applications for which it has been designed : the indoor unit is not suitable to be installed in areas used for laundry.
Page 35
Model 09/12 49.2ft(15m) 26.24ft(8m) 18/24 98.4ft(30m) 49.2ft(15m) One round loop will help reduce noise and vibration. The appearance of the unit may be different from the diagram depending on the model. English-35 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 35 2015/10/12 15:43:10...
Page 36
(Unit : inch) When the air outlet is towards the wall When 3 sides of the outdoor unit are blocked by the wall 11.8 or more 23.6 or more 23.6 or more 23.6 or more English-36 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 36 2015/10/12 15:43:10...
Accessories in the indoor unit case Installation Plate (1) Batteries for Remote Installation Plate (1) Remote controller (1) 09/12 (04 frame) 18/24 (05 frame) controller (2) User’s & Installation Wi-Fi Manual (1) Cap Screws(2) Manual (1) English-37 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 37 2015/10/12 15:43:11...
Page 38
Accessories Accessories in the outdoor unit case Optional accessories Tools required for installation General Tools Tools for test operations English-38 AR7000K CV HP_IB&IM_DB68-05637A-00_EN.indd 38 2015/10/20 18:34:10...
(3) Attach the installation plate to the wooden upright using tapping screws. If you install the indoor unit on a gypsum board (1) Use stud finder to find out locations of the studs. (2) Fix the plate hanger on two studs. English-39 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 39 2015/10/12 15:43:12...
Cover panel is assembled on the bottom part of the indoor unit (as shown in the illustration) and it is fastened with screws. Remove the Cap screw first and unfasten the screws so that you can disassemble the cover panel. Cap Screw <Remove the Cap screw> Cover Panel <Unfasten the screw> English-40 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 40 2015/10/12 15:43:13...
Page 41
Lock the side, center, and bottom hooks in this sequence. Tighten the bottom panel with the screws, and close the screw holes with their cap. <Lock the side hook> <Lock the bottom hook> <Fasten the screw> <Assemble the Cap screw> English-41 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 41 2015/10/12 15:43:16...
If unit is uninstalled, first disconnect electrical cables, then refrigerant connections. If the outdoor unit is more than 26.24ft(8 m) meters away from the indoor unit, you must extend the cable. The maximum length of the cable is 49.2ft(15m)( 09/12 )/98.4ft(30m)( 18/24 English-42 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 42 2015/10/12 15:43:16...
Page 43
9. Connect the cables to the terminals as seen in the picture. L1 L2 10. Connect the grounding conductor to the grounding terminals. 11. Close the terminal board cover by tightening the screw carefully. English-43 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 43 2015/10/16 10:33:09...
7. For further details on how to connect to the outdoor unit and evacuate the air, refer to page 49~51. refer to page 53 for further details. If the flare nut is over-tightened, the flare may break and cause refrigerant gas leakage. All refrigerant pipe connection must be easy accessible and serviceable. English-44 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 44 2015/10/12 15:43:17...
(see below examples of correct and incorrect cut edges). Pipe Oblique Rough Burr cutter Pipe 3. To prevent a gas leak, remove all burrs at the cut edge of the pipe using a reamer. English-45 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 45 2015/10/12 15:43:17...
Page 46
7. For further details on how to connect to the outdoor unit and evacuate the air, refer to page 49~51. If the flare nut is over-tightened, the flare may break and cause refrigerant gas leakage. English-46 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 46 2015/10/12 15:43:18...
Make sure the two hoses are firmly connected, there is no water leakage. 5. Connect the Drain Hose after using Foam Insulation to wrap the Extended Hose. Then, Use vinyl tape to wrap the each side of connection by 0.79inch(20mm) . English-47 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 47 2015/10/12 15:43:18...
5. Check for leakage on both side of the drain outlet. Drain pan outlet Rubber cap Pour the water in direction of arrow. Direction of condensate flow Make sure that the water does not overflow onto the electrical part. English-48 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 48 2015/10/12 15:43:19...
Installing and connecting the drain hose to the outdoor unit In Heat mode, ice may accumulate. During defrost, check for condensate drain. 1. Insert the drain plug into the drain hole on the underside of the outdoor unit. Drain plug off ground.
Page 50
‘A’ g of refrigerant R-410A must be added for each extra meter. Model 09/12/18 If you use a pipe shorter than 24.6ft(7.5m), The evacuate time is normal. Refer to the Service Manual for further details. English-50 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 50 2015/10/12 15:43:19...
Page 51
Cylinder with siphon Cylinder without siphon Siphon Charge the refrigerant standing the Charge the refrigerant turning the cylinder cylinder upright. upside down. characteristics of the equipment vary. If cylinder doesn’t have syphon, upset it. English-51 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 51 2015/10/12 15:43:19...
After 2 minutes of operation, shut the suction valve with the same wrench. Turn the system off and switch mains supply off. Disconnect tubing. After disconnection, protect valves and tubing ends from dust. Compressor damage may occur if run at a negative suction pressure. English-52 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 52 2015/10/12 15:43:20...
Designed to cut off residual vibration from outdoor unit to rack. (not supplied with product) vibration transferred by outdoor unit towards wall. Soft rubber designed to cut off vibration from rack to wall. (not supplied with product) English-53 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 53 2015/10/12 15:43:20...
2. When the air conditioner is in standby state, use the remote controller to start the Smart Install mode. 1) Press the Set, Mode and Power button simultaneously for 4 seconds. Remote controller may be different (image/functions) depending on the model. English-54 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 54 2015/10/12 15:43:21...
Page 55
(For Inverter model only) 2. Check for refrigerant leak between valve and Check the LED display on outdoor unit pipe connection. for the details. : Off / : Blinking / : On English-55 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 55 2015/10/12 15:43:22...
4 . After approximately 1 minutes, close the valve on the low pressure side. 5 . Stop operation of the air conditioner by pressing the power button on the indoor unit or remote controller. 6 . Disconnect the pipes. English-56 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 56 2015/10/12 15:43:22...
5. Apply heat to the contraction tube to contract it. 1.57inch(40mm) Contraction tube 6. After tube contraction work is completed, wrap it with the Insulation tape insulation tape to finish. - Incomplete wire connections can cause electric shock or a fire. English-57 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 57 2015/10/12 15:43:23...
6. Assemble the Cover PCB and the front panel. If the Sub PCB is not installed, arrange the wire for multi system (connection) as shown in the illustration. Wire for multi system connection English-58 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 58 2015/10/12 15:43:25...
Page 60
Installation of this product should follow the manufacturer’s refrigerant charging and air flow instructions. Failure to confirm proper charge and airflow may reduce energy efficiency and shorten equipment life. English-60 AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 60 2015/10/12 15:43:26...
Page 62
QUESTIONS OR COMMENTS? COUNTRY CALL OR VISIT US ONLINE AT U.S.A 1-800-SAMSUNG(726-7864) www.samsung.com/us/support - Consumer Electronics U.S.A 1-800-SAMSUNG(726-7864) www.samsung.com/us/support - Mobile Phones www.samsung.com/ca/support (English) CANADA 1-800-SAMSUNG(726-7864) www.samsung.com/ca_fr/support (French) AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 62 2015/10/12 15:43:26...
Page 63
Series Air Conditioner user & installation manual imagine the possibilities Thank you for purchasing this Samsung product. DB68-05637A-00 AR7000K CV HP_IB&IM_DB68-05637A-00_EN.indd 63 2015/11/6 15:05:11...