Do not place a cloth or other materials over it. Remove the batteries if you don't use the remote control for a long time. (If applicable) Use the remote control within 7 meters from the indoor unit. (If applicable) Samsung Electronics...
Never store or load the air conditioner upside down or sideways to prevent the damage to the compressor. Young children or infirm persons should be always supervised when they use the air conditioner. Max current is measured according to IEC standard for safety. Current is measured according to ISO standard for energy efficiency. Samsung Electronics...
It’s so easy to install! You can easily hang the product on the wall and connect the pipes and wires by opening the cover on the bottom of the product. Now you won’t have to tilt the product to connect the pipe and the wires! Samsung Electronics...
Page 7
Model AR07MSPXASINEU AR09MSPXASI/EU AR12MSPXASI/EU AR07MSPXBWKNEU AR09MSPXBWK/EU Rating Mode Unit Wall-mounted Wall-mounted Wall-mounted Wall-mounted Wall-mounted T1 Cool Btu/h 6824 2500 3500 6824 2500 Capacity T3 Cool Btu/h Heat 7506 3200 4000 7506 3200 T1 Cool 1080 Power Input T3 Cool Heat...
Page 8
16 ˚C~32 ˚C 16 ˚C~32 ˚C Cooling -10 ˚C~46 ˚C -10 ˚C~46 ˚C -10 ˚C~46 ˚C Operation range 27 ˚C or less 27 ˚C or less 27 ˚C or less Heating -15 ˚C~24 ˚C -15 ˚C~24 ˚C -15 ˚C~24 ˚C Samsung Electronics...
Page 9
2-3 The Com DEVELOPMENT MODEL Model AR07MSPXASINEU AR09MSPXASI/EU AR12MSPXASI/EU AR07MSPXBWKNEU AR09MSPXBWK/EU Indoor Unit Design Outdoor Unit Indoor Unit 10.1 10.1 Net Weight Outdoor Unit 31.6 31.8 27.6 Indoor Unit 828*267*265 828*267*265 828*267*265 828*267*265 828*267*265 Net Dimension Outdoor Unit 790*548*285 790*548*285...
Page 10
Net Weight Outdoor Unit 31.6 31.8 Indoor Unit 828*267*265 828*267*265 828*267*265 Net Dimension Outdoor Unit 790*548*285 790*548*285 Indoor Unit Noise Outdoor Unit Air Purifying System Wind free Wind free Wind free Indoor Display 7 SEG 7 SEG 7 SEG Samsung Electronics...
Page 11
DB93-15883K (AR✴✴MSPX✴✴) ASSY WIRELESS REMOCON DB93-15883J (AR✴✴MSWX✴✴) HOLDER REMOCON DB61-06087A BATTERY DB47-90024A Indoor Unit DB68-06728A MANUAL USERS DB68-06729A MANUAL INSTALL DB68-06732A MANUAL INSTRUCTION DB68-06910A SCREW-TAPPING 6002-000623 CAP-SCREW DB67-01404B Rubber Leg DB67-01533A Outdoor unit case Samsung Ele ctr o nic s...
Because the teat mode operate the cool mode by force not related to the set temperature / indoor ● temperature, check whether each subordinate is operated normally or not after completing installation Note and must turn off the power of the air conditioner. Samsung Electronics...
Page 13
Heatsink overheat or IPM overheat *Note* If the set doesn’t work (No power), check the thermal fuse of terminal block OPEN or SHORT with Multimeter. * Measure the thermal fuse housing PIN#1~2 : OPEN(disconnection)-> defective product Samsung Ele ctr o nic s...
Page 14
3-2-2 Outdoor LED Display Error and Check method Outdoor OLP over temperature error Samsung Ele ctr o nic s...
2. Press the temperature button simultaneously and insert the battery again. 3. Make sure the remote control display shown as Step 2 Enter the Options Setup mode and select your options asscording to the following procedure. (ARMSPX) (ARMSWX) Samsung Electronics...
Page 16
’ ’ Ding’ ’ or ’ ’ Diriring’ ’ is heard and the OPERATION ICON( ) lamp of the display me time, then the input of option is completed. (If the deriving sound isn’t heard, try again pressing the ON/OFF button.) Samsung Electronics...
Page 17
Every time you push the button, the display panel reads . . . repeatedly. (ARMSPX) (ARMSWX) Push the Mode button to set the display panerl to 1. Every time you push the button, the display panel reads . . . repeatedly. Samsung Electronics...
Page 18
1. If all lam y to retry. 2. If the unit is not working properly or all lamps are continuously orrect option code is set up for its model. □ Option Items Model Option code AR07MSPXASINEU 011E45-16EA3A-271416-3727C4 AR09MSPXASI/EU 011E45-17EA4A-271920-3726C4 AR12MSPXASI/EU 011E45-18EA6B-272328-3716C4 AR07MSPXBWKNEU...
Necessary Tools +SCREW DRIVER Q’ty 1 ea. To assembly and disassembly the screw MONKEY SPANNER Q’ty 1 ea. To assembly and disassembly the Fan motor and Compressor - SCREW DRIVER Q’ty 1 ea. To assembly and disassembly the screw Samsung Electronics...
Remove the Cap Screw as shown on the right side and then remove the screw and separate the Cover Panel. 4) Cover Panel is fixed to body by Hook in center area and side area. Center area Side area Side area HOOK F03,F04 SAMSUNG ELECTRONICS...
Page 21
5) Separate the hook after pushing both end of Cover Panel as shown in the figure.(Watch out for the damage of the hook) 6) Raise front part upward obliquely as shown in the figure and then remove the hooks. SAMSUNG ELECTRONICS...
Page 22
Assembly of Cover Panel after service end. - Reassembly is in the reverse order of the removal. - Piping and drain hose must be careful not to damage and Progress must be done with both hands. Hook (Side) Hook (Center) Screw Cap Screw SAMSUNG ELECTRONICS...
Page 23
4 HOOK Structures. When separate the hook : Use the (-) screw Driver. (-)Screw Driver Insert the hook and then pull the hook as shown on the right side. (Watch out for the damage of the hook) SAMSUNG ELECTRONICS...
Page 24
Parts Procedure Remark 9) Remove the Panel Frame from the Main Frame as shown on the right side. 10) Remove the WIFI KIT connector. WIFI KIT connector is located of Panel Front. (For model with WIFI KIT) SAMSUNG ELECTRONICS...
Page 25
Humidity wire connector. Caution: When you separate the connector, pull pressing the locking button. 14) Loosen the ground wire. 15) Loosen the remote control PCB wire connector. Caution: When you separate the connector, pull pressing the locking button. SAMSUNG ELECTRONICS...
Page 26
16) Take off the CASE-CONTROL from the main frame after loosen the remaining connector. Caution: When you separate the connector, pull pressing the locking button. TRAY DRAIN 17) To detach TRAY-DRAIN from the main frame, pull the bottom of the TRAY- DRAIN towards you. SAMSUNG ELECTRONICS...
Page 27
19) Unfasten the screw at the left side. (use + Screw Driver) 20) Unfasten the screw at the right side. (use + Screw Driver) 21) To detach Evaporator from the main frame, pull the bottom of the Evaporator towards you. SAMSUNG ELECTRONICS...
Page 28
Remark FAN MOTOR 22) Unfasten the screw. (use + Screw Driver) & CROSS FAN 23) Detach the FAN Motor case. 24) Unfasten the screw a little. (use + Screw Driver) 25) Pull the CROSS-FAN to the left side. SAMSUNG ELECTRONICS...
Page 29
- Confirm Seal of backside necessarily after replace of Assy SPI Lamp. - Seal should be close adhesion to SPI Lamp. - Measure as shown on the right side since replace. (If the seal is not close adhesion perfectly : Defectiveness can happen) SAMSUNG ELECTRONICS...
Operating Instructions and Installation 4-4 Outdoor Unit (N-SI,N-WW) Heat pump model 1) Loosen each screws and detach Common work the cabi Top cover. 2) Loosen screws of the cabi front and detach it. 4-22 Samsung Electronics...
This process is supported by heating models only: AR✴✴MS✴✴ series. 4) Loosen ing screws from the Cabi Front Lh and detach it. 5) Loosen ng screws from the Cabi Side Rh and detach it. Samsung Electronics 4-23...
Page 32
(Use Monkey Spanner.) 2) Detach the Fan Propeller. 3) Loosen ng screws to detach the Motor. (Use Monkey Spanner.) 4) Disconnect the wire between Ass’y Control Out and Motor. 5) Loosen ng bolts and detach the Bracket Motor 4-24 Samsung Electronics...
Page 33
3) Detach several connectors from the PCB of Ass’y Control Out. 1) Release the refrigerant at Heat Exchanger 2) Loosen ng screw on both sides. 3) Disassemble the pipes in both inlet and outlet with welding torch. 4) Detach the Heat Exchanger. Samsung Electronics 4-25...
Page 34
Parts Procedure Remark Compressor 1) Loosen the ng nut and detach the Compressor Lead Wire. (Use Monkey Spanner.) 2) Loosen the bolts at the bottom of Compressor like the picture on the right side. (Use Monkey Spanner.) 4-26 Samsung Electronics...
EEV or Valve Close error-Self diagnosis E422/E554 /Gas Leak Error E458 Out door and Fan Error E461 Comp. Starting Error E464 IPM Over Current (O.C) Error E465 Comp V_Iimit/I_limit Error E500 Heatsink overheat or IPM overheat INDOOR - UNIT CODE NO : DB68-04014A SAMSUNG ELECTRONICS...
: Good Bad : Ring terminal is connected reversely Bad : Not clamped Screw Bad : In the gap between Ring terminal & Screw Bad : Unused Ring Terminal 8-13 Samsung Electronics...
9. Operating Instructions 9-1 Name of Each Part 9-1-1 Indoor Unit The design and shape are subject to change according to the model. Main Parts The actual product may differ slightly from the image depicted below. 01 Air intake 06 WI-FI module 02 Air filter 07 Wind-free panel 03 Air flow blade (up and down)
9-2 Wireless Remote control-Buttons and Display Set temperature indicator Timer option indicator Operation mode indicator Options indicator Low battery indicator Transmit indicator Fan speed indicator Virus doctor indicator Wind-free indicator Vertical air swing indicator Horizontal air swing indicator Power button Temperature button Timer button Fan speed button...
HEAT mode, and indoor fan and out- Indoor fan and outdoor fan stop operation door fan do not operate intermittently for within 20% intermittently in a HEAT mode. of the total heater operation. Samsung Electronics 10-1...
Is the power is normal? Exchange the PBA of no power unit (check the LED Lamp) Exchange the indoor unit PBA. Is the communication error occurred again? Terminate the service. Exchange the outdoor unit PBA. 10-2 Samsung Electronics...
Is the connection of power cable supply power and measure the voltage of #1-#2 in and communication cable normal? the connector Exchange the indoor PBA Below 0.5V or Over 4.5V? Micom error or connector check Exchange the indoor PBA Samsung Electronics 10-3...
Is the voltage of CN72 Exchange the Indoor PBA #3-#5 and #3-#6 with in 1Vdc~15Vdc during the operation? PBA problem or Motor problem Change the PBA first and check the operation Exchange the Fan motor 10-4 Samsung Electronics...
Is the connection of power cable supply power and measure the voltage of "B"in the connector and communication cable normal? Exchange the Outdoor PBA Below 0.5Vdc or Over 4.5Vdc? Micom error or connector check Exchange the Outdoor PBA Samsung Electronics 10-5...
Is the connection of power cable supply power and measure the voltage of "B" in the connector and communication cable normal? Exchange the Outdoor PBA Below 0.5Vdc or Over 4.5Vdc? Micom error or connector check Exchange the Outdoor PBA 10-6 Samsung Electronics...
Is the connection of power cable supply power and measure the voltage of "B"in the connector and communication cable normal? Exchange the Outdoor PBA Below 0.5Vdc or Over 4.5Vdc? Micom error or connector check Exchange the Outdoor PBA Samsung Electronics 10-7...
* Heating mode * * Cooling mode * Is the outdoor temperature over 40 or Is the outdoor temperature under -7 under -30 ? The temperature condition is too poor to operate. Wait until temperature is changed 10-8 Samsung Electronics...
2. Troubleshooting procedure MODEL "A" DB92-02866A CN501 DB92-02867A CN202 power o and download EEPROM data (or. Insert the service EEPROM IC) Restart after power o Terminate the service Is the error appeared again? Exchange the Outdoor PBA Samsung Electronics 10-9...
Is the voltage of "A" #3-#5 and Exchange the Outdoor PBA #3-#6 with in 1Vdc~15Vdc during the operation? PBA problem or Motor problem Change the rst and check the operation Exchange the Fan motor Samsung Electronics 10-10...
Is the connection of compressor wire is normal? Connect the comp wire normally Download the EEPROM data Is the restart error occurred again? Terminate the service Is the compressor body and interphase Exchange the Outdoor PBA resistance insulated? Exchange the compressor 10-11 Samsung Electronics...
Is the connection of compressor wire is normal? Connect the comp wire normally (PBA and Compressor) Is the restart error occurred again? Terminate the service Is the compressor body and Exchange the Outdoor PBA interphase resistance insulated? Exchange the compressor Samsung Electronics 10-12...
R410,R411,R412 IC451 R408,R409,R410 DB92-02867A R063,R064,R065 IC451 Restart after power Is the PFC shunt and IPM Exchange the Outdoor PBA shunt resistance value correct? Is the current sensor error appeared again? Terminate the service Exchange the Outdoor PBA Samsung Electronics 10-13...
Connect the comp wire normally Is the O.C error occurred again? Terminate the service Is the condition of indoor/outdoor temperature Restart after returning to the normal load normal load? Is the O.C error Terminate the service occurred again? 10-14 Samsung Electronics...
Page 70
Is the position of Correct the sensor position or temperature sensor and sensing exchange the sensor value normal? Is the compressor body and interphase resistance Exchange the Outdoor PBA insulated? Exchange the compressor Samsung Electronics 10-15...
Check the fuse open or not? (F001) Exchange the Main PBA Restart after power o . Is the power normal? Check the power source. Is AC power is normal for SMPS? Exchange the Main PBA CN150 : 220Vac~240Vac Check SMPS wire connection Samsung Electronics 10-16...
Is the connected louver wire? Does operation start when swing button of the Normal remote control unit pushed? Is the voltage changeable at the pin#2~#5 of CN61, Exchange the PBA CN62, CN63 (louver connector)? Up/Down louver motor is faulty. Samsung Electronics 10-17...
2. Troubleshooting procedure If the connector was normally assemble? Check the connector to normally assemble. Have the battery in remote control? Insert the battery in remote control. All the lights out ? Re-check the connector Exchange the display PBA 10-18 Samsung Electronics...
±10% extent of reference pressure? - Discharge temperature and the indoor [Execute the troubleshooting] Check the refrigerant leaks. Check the PCB Relay. - Fill up perfectly refrigerant after re-vacuum. Execute the related trouble- shooting. 10-19 Samsung Electronics...
The condition is too poor for air conditioner to operate Wait until OLP temperature is decreased Wait until OLP temperature is decreased Restart after power off Restart after power off Exchange the Outdoor PBA Exchanged the Compressor d h C 10 -20 Samsung Electronics...
Download Comm. Main Sensor - Inv Control Main Inverter Current 4Way V/V Micom Micom Sensing Inverter Compressor Download ZCP OVP DC LINK Communi Comm. In - out cation Converter SMPS Filter POWER Reactor SMPS - PBA SMPS 11-2 Samsung Electronics...
Page 78
2) The fan motor of the indoor unit . Fan motor connector(CN72) is 1. Fan speed(high) doesn't run faulty 2. Continuous Operation 3) The power voltage between terminal #3-#5 of the . PBA is faulty connector(CN72) is 0V Samsung Electronics 11-3...
Page 79
1) Normal : RED on, GRN blink, YEL o 2) Abnormal . F1,F2 wire wrong wiring Check the LED lamp display - All o check no power . Outdoor PBA is faulty - abnormal display : check error mode 11-4 Samsung Electronics...
It occurs when the drain pump is plugged out or it is out of order. Check the power of the drain pump and the position of the drain hose, and when the pump is faulty, contact the drain pump manufacturer. Samsung Electronics do not manufacture drain pumps. So, we are not able to correct the drain pump problems.
Page 82
Also, the remote con- troller may mot work under intensive light from a 3-wave length lamp or a neon sign due to the EMI. In this case, take the remote controller closer to the receiver. Samsung Electronics 12-3...
Page 83
There is a cost table. But, our service engineer needs to visit to total up the cost correctly. When you move in, make sure to contact Samsung Electronics Service Center or Authorized Service Agent in advance to streamline the process.
Clean the Air lter with a vacuum cleaner or soft brush. If dust is too heavy, rinse it with running water. Insert the air lter back in its original position. Dry the Air lter in a ventilated area. it once a week. Samsung Electronics 12-5...
Electric and earth work shall meet the "Electric Facility Technology Standard" and the "Internal Wire Regulation" of the Electric Business Laws. ■ Inspection & Trial Run Upon completion of the tests, you shall make a trial run while you explain the main functions of the air conditioner to finish the installation. 12-6 Samsung Electronics...
3 way valve. And mount the service port cap to 3 way valve. Valve stem Stem cap 7) Check for gas leakage. (gas) - At this time, especially check for gas leakage from the 3 way valve's stem nuts, and from the service port cap. (liquid) Samsung Electronics 12-7...
Page 87
7) Close the cap of each valve. Relocation of the air conditioner entering. At this time, cover the valve of the outdoor unit and the other pipe using a cap or vinyl plug to avoid foreign material entering. 12-8 Samsung Electronics...