Features of your new air conditioner Cool Summer Offer On those hot sweltering summer days and long restless nights, there is no better escape from the heat than the cool comforts of home. Your new air conditioner brings an end to exhausting hot summer days and lets you rest.
If you have any questions, call your nearest contact center or find help and information online at www.samsung.com. Important safety symbols and precautions: Hazards or unsafe practices that may result in severe WARNING personal injury or death.
Page 5
Safety precautions Do not install this appliance near a heater, inflammable material. Do not install this appliance in a humid, oily or dusty location, in a location exposed to direct sunlight and water (rain drops). Do not install this appliance in a location where gas may leak. ...
Page 6
Safety precautions FOR POWER SUPPLY CAUTION When not using the air conditioner for a long period of time or during a thunder/lightning storm, cut the power at the circuit breaker. Failing to do so may result in electric shock or fire. WARNING FOR USING If the appliance is flooded, please contact your nearest service center.
Page 7
Safety precautions Do not touch the air flow blade with your hands or fingers during the heating operation. This may result in electric shock or burns. Do not insert your fingers or foreign substances into the air inlet/outlet of the air conditioner.
Page 8
Safety precautions CAUTION FOR USING Do not place objects or devices under the indoor unit. Water dripping from the indoor unit may result in fire or property damage. (example electrical appliances) Check that the installation frame of the outdoor unit is not broken at least once a year.
Page 9
Safety precautions This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Checking before use Operation ranges The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use. Indoor Outdoor Mode Indoor humidity Remark temperature temperature Cooling ˚C~32 ˚C -5 ˚C~46 ˚C Relative humidity 80% or less AJ100*** outdoor temperature : -10˚C~46˚C .
Checking the name of the parts Your air conditioner may slightly look different from illustration shown below depending on your model. Main parts Room temperature sensor Air intake Air filter(under the panel) Air flow blade (up and down) Blade pin lever Air flow blade (left and right) Display indicator...
Checking the remote controller • Point the remote controller towards the remote controller receiver of the indoor unit. • W hen you properly press the button on the remote controller, you will hear beep sound from the indoor unit and a transmit indicator( ) appears on the remote controller display. Remote controller buttons Remote controller display Power Smart Saver Turn on/off the air conditioner. Has no this function. Mode Set one of the 5 operating modes (see pages 14-15 for instructions).
Page 13
Remote controller display Operation mode indicator Turbo indicator Low battery indicator Quiet indicator Transmit indicator Smart Saver indicator Air swing indicator Has no this function Fan speed indicator Auto (Turbo) On Timer indicator Off Timer indicator Medium indicator High Battery changing time When the battery is exhausted, ( ) will be displayed in the remote controller display.
Basic function Basic operation is an operation mode that can be selected by pressing the Mode button. Auto In Auto mode, the air conditioner will automatically set the temperature and fan speed depending on the room temperature detected by the room temperature sensor. • I f using a multi system, in Auto operation, the system selects a temperature setting and an appropriate operation mode (COOL or HEAT) based on the room temperature at the start of the operation.
Page 15
Press the button to turn on the air conditioner. Press the button to set the operating mode. • Each time you press the Mode button, the mode will change in order of Auto, Cool, Dry, Fan and Heat. Press the button to set the desired fan speed. Auto(2-Step Cooling or Heat) (Auto) Cool...
Adjusting the air flow direction Air flow can be directed to your desired position. Vertical air flow Air flow blades move up and down. Press the Air swing button on the remote controller. A ir swing indicator will be on and air flow blades move up and down continuously to f f circulate the air.
using the turbo function Turbo function will be helpful to cool your room quickly and effectively. Press the Turbo button on the remote controller during Cool mode. T urbo indicator appears on the remote controller display and the air conditioner f f operates in Turbo function for 30 minutes.
Using the Auto Clean function Auto clean function will prevent from growing mold by eliminating the moisture inside of the indoor unit. Your indoor unit evaporates the moisture inside of the unit. Activate this function to provide you with more clean and healthier air. Press the Auto Clean button.
mode For a comfortable sleep, the air conditioner will operate it Fall asleep Sound sleep Wake up from mode. When the air conditioner is on and in cool/heat mode 1. Press the button on the remote controller. indicator appears and Off timer indicator starts blinking on the remote f ...
Setting the On/Off timer You can set the air conditioner to turn on/off automatically at desired time. Setting On timer while the air conditioner is off / Off timer while the air conditioner is on 1. Press the On Timer/Off Timer button. Setting On timer On/Off timer indicator will blink on the remote controller display.
Page 21
Combining On Timer and Off Timer If the air conditioner is on If the air conditioner is off Preset time on On timer is longer than Off timer Preset time on On timer is shorter than Off timer Ex) On timer : 3 hours, Off timer : 1 hour Ex) On timer : 3 hours, Off timer : 5 hours - The air conditioner will operate the Off timer after - The air conditioner will operate On timer after 3 hours...
Cleaning the air conditioner • Make sure to turn off the power of the indoor unit and cut-off the power supply before cleaning the air conditioner. CAUTION Cleaning the indoor unit f Wipe the surface of the unit with a slightly damp micro fiber cloth when needed .
Page 23
Removing the Air filter Grab the handle and lift it up. Then, pull the Air filter towards you and slide it down. Air filter Cleaning the air filter Washable foam based air filter captures large particles from the air. The filter is cleaned with a vacuum or by hand washing. Open the panel and put the Air filter out.
Maintaining the air conditioner If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best condition. 1. Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and cut-off the power supply.
troubleshooting Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses. PROBLEM SOLUTION The air • Check power status and then operate the air conditioner conditioner does again. not work at all. • P lug in or switch on the circuit breaker and then operate the air conditioner again. • C heck if you have set the Off Timer. Operate the air conditioner again by pressing the Power button.
Page 26
troubleshooting PROBLEM SOLUTION Air flow • C heck if you have selected Auto/Dry/ mode. In adjustment is not these modes, desired temperature is set to auto and you working. cannot adjust the temperature. Fan speed • C heck if you have selected Auto/Dry/Turbo/ adjustment is not mode. In these mode, fan speed is set to Auto and you working.
In order to help prevent electric shocks, fires or injuries, always stop the unit, disable the protection switch and contact SAMSUNG’s technical support if the unit produces smoke, if the power cable is hot or damaged or if the unit is very noisy. Always remember to inspect the unit, electric connections, refrigerant tubes and protections regularly. These operations ...
Safety precautions After completing the installation, always carry out a functional test and provide the instructions on how to operate the air f conditioner to the user. Do not use the air conditioner in environments with hazardous substances or close to equipment that release free flames to f avoid the occurrence of fires, explosions or injuries.
Page 29
Choosing the installation location Outdoor Unit Where it is not exposed to strong wind Well ventilated and dustless places Where possible keep out of sunlight and rain Where neighbors are not annoyed by operation sound or hot air f Solid wall or support that prevents vibration and is strong enough to hold the product weight ...
Accessories The following accessories are supplied with the air conditioner: • The number of each accessory is indicated in parentheses. Accessories in the indoor unit case Installation Plate Remote controller Batteries for User’s & Installation Remote controller (2) Manual (1) Tools required for installation General Tools • Vacuum Pump(Backward flowing prevention) • Manifold Gauge • Stud Finder • Torque Wrench • Pipe Cutter...
Fixing the installation plate You can select the direction of the drain hose depending on where you want to install the indoor unit. Therefore before fixing the installation plate to a wall or a window frame, you must determine the position of the 65mm hole through which the cable, pipe and hose pass to connect the indoor unit to the outdoor unit.
Connecting the assembly cable If using a multi system, install as described in the installation manual supplied with the outdoor unit. Cable specification Model Power cable Interconnection cable Type GL 3G1,0 4G1,0 мм мм 020/025/035 ² H05VV-F ² H07RN-F 3G1,5 мм...
Page 33
2 . Open the cover panel. 3 . Remove the screw securing the connector cover. 4 . Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals. (Refer to the picture below) • E ach wire is labeled with the corresponding terminal number.
Installing and connecting the assembly pipe of the indoor unit Connect indoor and outdoor units with field-supplied copper pipes by means of flare connections. Use insulated seamless refrigeration grade pipe only, (Cu DHP type according to ISO1337), degreased and deoxidized, suitable for operating pressures of at least 4200 kPa and for burst pressure of at least 20700 kPa.
Evacuating the indoor unit The indoor unit is supplied with inert gas (nitrogen). Before installing the unit, check if nitrogen gas flow out of indoor unit. If this one isn’t true, DO NOT INSTALL THE UNIT since leakage could be inside the indoor unit. 1.
Page 36
Cutting or extending the pipe 4. Put a flare nut slightly into the pipe and modify the flare. Outer Diameter (D) Depth (A) Flaring Size (B) 90°± 2° ø6.35 mm 1.3 mm 8.7 - 9.1 mm ø9.52 mm 1.8 mm 12.8 - 13.2 mm ø12.70 mm 2.0 mm...
Installing and connecting the drain hose of the indoor unit When installing the drain hose for the indoor unit, check if condensation draining is adequate. When passing the drain hose through the 65 mm hole drilled in the wall, check the followings: Wall Indoor unit Drain hose...
Installing and connecting the drain hose of the indoor unit 20 mm 20 mm or more or more 40~45 mm Drain hose Extension Extension drain hose Drain hose drain hose Foam Insulation Vinyl Tape 6. Pass the drain hose under the refrigerant pipe, keeping the drain hose tight. Shield 7.
Fixing the indoor unit in place Perform the following work on the area where gas leak test was done priory. After checking for gas leaks in the system, insulate the pipe, hose and cables. Insulation Then place the indoor unit on the installation plate. 1.
Final check and trial operation To complete the installation, perform the following checks and tests to ensure that the air conditioner operates correctly. Check the followings: • Strength of the installation site • Tightness of pipe connection to detect gas leak • Electric wiring connection • Heat-resistant insulation of the pipe • Drainage • Grounding conductor connection • Correct operation (follow the steps below) 1. Press the Power button and check the following: The indicator on the indoor unit lights up.
how to connect your extended power cables 1. Prepare a compressor and the following tools. Compression Tools Spec Shape dimension Crimping MH-14 pliers 20xØ6.5 Connection • After compressing it, pull both sides of the wire sleeve (mm) (HxOD) to make sure it is firmly pressed. Insulation Method 1 Width 19 mm...
Sub PCB installation(optional) (Wried remote controller, central remote controller etc.) 1. Turn the power off and take off the front panel of the indoor unit. 2. Take off the Cover PCB. 3. Attach the Sub PCB to the right side of the Panel-frame. Cover PCB 4.
Page 45
AJJBRD Series Air Conditioner user & installation manual imagine the possibilities Thank you for purchasing this Samsung product. EN RU UK KK DB68-05419A-03...