hit counter code

Outdoor Cond Temperature Sensor Error - Samsung AR09RXPXBWKNEU Service Manual

Indoor/outdoor units
Table of Contents

Advertisement

10-2-5 Outdoor Cond temperature sensor error

Indoor display
3-LED DISPLAY
LED1
LED2
Outdoor display
LED ON
LED BLINKING
1. Checklist :
1) Is the sensor connected correctly?
2) Is the sensor placed correctly?
3) Does the both terminal of sensor satisfy the resistance value in accordance with temperature?
4) Is the resistance value of sensor connection pull-up correct?
2. Troubleshooting procedure
Is the sensor connector("A")
connected correctly in accordance
with a color?
YES
Is the sensor resistance value
"B" 10kohm±3% at the room temperature
of 25 ℃ ?
YES
Connect the sensor to PBA connector supply
power and measure the voltage of "B"
communication cable
Below 0.5Vdc or Over 4.5Vdc?
NO
Micom error or connector check
YES
Exchange the Outdoor PBA
7-SEG DISPLAY
LED3
E231
LED OFF
NO
NO
YES
97
DESCRIPTION
Outdoor Cond temperature sensor error
Outdoor Cond temperature sensor error
Model
ALL
Reconnect the sensor connector.
Sensor Replace
Sensor resistance value : 20 - 12.09kohm
Exchange the Outdoor PBA
"A"
"B"
CN251
CN251 #5-#6
30 - 8.31kohm
35 - 6.94kohm
40 - 5.83kohm

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents