GRIETA DE COLMADO DE AIRE ACONDICIONADO CLIMATISEUR MONOBLOC DE TYPE SPLIT E S F DB68-02365A(3) OWNER’S INSTRUCTIONS & INSTALLATION MANUAL MANUAL DE INSTRUCCIONES & MANUAL DE INSTALACIÓN MANUEL D’UTILISATION & MANUEL D’INSTALLATION Indoor Unit Outdoor Unit APC3240C UPC3240C (Cool) (Refrigeración) (Refroidissement)
The manufacturer does not take any responsibility for any accidents that occur because the air conditioner is not fixed firmly or installed securely, during installing or using the product. In case you experience difficulty in installation, you must use an installation specialist.
View of the Unit Indoor Unit Outer Air Flow Blades Inner Air Flow Blades Control Panel (refer to page 5) Air Filter (Inside) Air Inlet How to open the front panel Hold the upper part of the front panel, then pull it slightly forward.
Page 5
Outdoor Unit Air Inlet(Rear) Air Outlet Control Panel Temperature setting Power indicator Operating mode indicators Operating indicators Timer indicator Swing indicator Operating mode selection button (AUTO, COOL, DRY, FAN) Connection Valve Remote control sensor Fan speed indicators Operating indicators Fan speed selection button Temperature adjustment buttons...
Remote Control - Buttons and Display Remote control transmission indicator Operating mode AUTO, COOL, DRY, FAN) Temperature setting Turbo mode Sleep mode Long mode Fan speed Air flow directions On Timer setting Off Timer setting Battery discharge indicator Mode selection button (AUTO, COOL, DRY, FAN) Temperature adjustment buttons...
Your Owner’s Instructions contains valuable information on using your air conditioner. Please take the time to read it as it will help you take full advantage of the unit’s features. The booklet is organized as follows.
You can use the AUTO, COOL, DRY and FAN functions depending on your specific requirement. For further details on the functions, refer to pages 9~14. All features of the air conditioner can be controlled with the remote control. Press any buttons depending on your specific requirements.
Selecting the Automatic Operating Mode You can start the air conditioner in Automatic mode from your remote control. In the Automatic mode, the standard temperature and the optimum fan speed is selected automatically. You can adjust the standard temperature but not the fan speed.
The air conditioner starts up in the mode selected when the unit was last used. The indoor unit beeps. IMPORTANT The air conditioner is fitted with a protection mechanism to prevent the unit from being damaged when it is started immediately after being: Plugged in Stopped lt will start up normally after three minutes.
If necessary, press the (On/Off) button. Result: The POWER indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used. The indoor unit beeps. IMPORTANT The air conditioner is fitted with a protection mechanism...
If necessary, press the (On/Off) button. Result: The POWER indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used. The indoor unit beeps. Press the button one or more times until remote control.
If necessary, press the (On/Off) button. Result: The POWER indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used. The indoor unit beeps. Press the button one or more times until remote control.
If necessary, press the (On/Off) button. Result: The POWER indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used. The indoor unit beeps. If the is not displayed at the top of the remote control, press the MODE button on the remote control one or more times until it appears.
Adjusting the Air Flow Direction Vertically You can adjust the position of the outer air flow blade on the upper part of the unit, thus increasing the efficiency of the air conditioner. Press the button one or more times as required.
To cancel the On Timer, press the ON TIMER button one or more times until the timer setting disappears. Press the (Set/Cancel) button. If you want to turn on the air conditioner before the timer reaches the setting time, press the button until the (On/Off) button.
Off timer setting. If you would like to turn the air conditioner on after 2 hours and to operate it for 2 hours: 1. Press the ON TIMER button until ‘2.0 Hr’ is displayed.
Setting the Sleep Timer The Sleep Timer can be used when you are cooling your room to switch the air conditioner off automatically after a period of six hours. If you wish to switch the unit off at a specific time, refer to page 17.
Here is a recommendation that you should follow when using your air conditioner. Topic Recommendation Power failure If a power failure occurs when the air conditioner is operating, the unit is switched off. When the power returns, the air conditioner start up again automatically.
Temperature and Humidity Ranges The following table indicates the temperature and humidity ranges within which the air conditioner can be used. If the air conditioner is used at... High temperatures Low temperatures High humidity levels Mode Outdoor Temperature Indoor Temperature Cooling 70°F to 109°F approx.
Cleaning Your Air Conditioner To get the best possible use out of your air conditioner, you must clean it regularly by two weeks to remove the dust that accumulates on the air filter. IMPORTANT Before cleaning your air conditioner, ensure that you have switched off the breaker used for the unit.
Check whether the TIMER indicator on the indoor unit is switched on. If so: - Wait until the switch-on time is reached and the air conditioner starts up automatically - Cancel the timer (see pages 16~18 for further details) Check that there are no obstacles between you and the indoor unit.
Max. Height Difference Dimensions INDOOR UNIT & Weight W X H X D Net Weight OUTDOOR UNIT W X H X D Net Weight Standard rating conditions Cooling APC3240C 30000 Btu/h 10.0 Pts/h 208-230V~, 60Hz 3250 Flare mm(in) 9.52(3/8) mm(in) 15.88(5/8)
Page 24
NSTALLATION ANUAL Contents ELECTION OF NSTALLATION LACE Indoor Unit ........26 Outdoor Unit .
Page 25
Be sure to read the installation manual carefully to ensure sufficient realization of the excellent performance of the unit. Be sure to drill a hole in the wall necessary for installation before attempting to install the unit. After completion of installation, be sure to perform a test operation of the unit to check for any problem, and then deliver the unit to the customer if the test results are acceptable.
SELECTION OF INSTALLATION PLACE Indoor Unit Install the unit at a place close to the wall facing the outside as it is necessary to perform piping connection with the outdoor unit. - It is effective to install the unit at a window side to ensure uniform distribution of indoor temperature.
ELECTRICAL WORK The electrical work should be performed by a specialist qualified for the work. Use the three phase power supply, and be sure to install the sub power distributing board for exclusive use with the unit(separately purchased by the user). Avoid octopus-type wiring as it can cause a drop in voltage, thus resulting in poor performance of the automatic control circuit.
INSTALLATION METHOD Outdoor Unit When using the anchor bolt 1. Fix the unit on a flat, rigid floor using the anchor bolt. (Anchor bolt : M10 x 4 points - separately purchased) Installation Procedures 1. Open the front panel, and remove the flare nut. 2.
Page 29
3. Install the high pressure pipe to the heat exchanger liquid pipe, and the low pressure pipe to the heat exchanger gas pipe respectively using the flare nut, taking care not to cause any leakage of refrigerant. 4. Be sure to insulate the pipe with appropriate insulation material. 5.
INSTALLATION METHOD Connection of Refrigerant Piping Flare Processing 1. Cut the pipe using the pipe cutter. 2. Insert the flare nut into the pipe, and then perform the flare processing. Pipe Bending 1. Perform bending of the pipe using the bender which has a specified bending radius.
Drilling a Hole in the Wall Drill a hole of 60mm(2 ") in diameter to the outside. The drilling should be done at a distance of less than 150mm(5 ") from the floor facing the indoor unit. Drain Hose Extend the drain hose to the drain hose connected to the drain pan, and fix it with the tape or a cable tie to prevent separation.
AIR PURGE The air in the indoor unit and in the pipe must be purged. If air remains in the refrigeration pipes, it will affect the compressor, reduce to cooling capacity and could lead to a malfunction. Use Vacuum Pump as shown at the figure. 1.
REFRIGERANT CHARGING Air purge(at the time of new installation only) Close the gas pipe side valve by turning it clockwise. Connect the pressure gauge to the low pressure side service valve, and then open the gas pipe side valve again. Connect it to the refrigerant filling tank.
CHECK AND TEST OPERATION Check Be sure to check the following again after completion of installation. 1. Check the piping connection area for any gas leakage. Indoor connection area 2. Is the drain hose properly connected? 3. Is the insulation of the piping in good condition? Insulation Outdoor connection area...
Test Operation After checking, read the owner’s instructions carefully, and perform a test operation. Then deliver the unit to the customer. (When delivering the unit, be sure to read carefully and follow the contents of the owner’s instructions.) CAUTION 1. Be sure to check whether the service valve is opened before attempting to perform the test operation.
Page 36