AP50M0✴ Series AP50M1✴ Series Air Conditioner user & installation manual imagine the possibilities Thank you for purchasing this Samsung product. ES FR PT AR DB68-05323A-02 Mirage_AP50M0@_IBIM_EN_05323A-02.indd 55 2016-05-19 오후 1:27:31...
Page 2
Features of your new air conditioner Strong Turbo/Long Function Your new air conditioner supports Turbo function which makes you cool fast for 30 minutes and Long function which makes the cool air goes to much further place. Look for Everywhere The elegant and harmonious design gives priority to the esthetics of your space and complements any of your existing interior décor.
Because the following operating instructions cover various models, the characteristics of your air conditioner may differ slightly from those described in this manual. If you have any questions, call your nearest contact center or find help and information online at www.samsung.com. Important safety symbols and precautions: Risk of death or serious personal injury.
Page 5
Never use a damaged or dusted power cable, or loosened power receptacle. f Potential risk of fire or electric shock. Install an exclusive circuit breaker and short-circuit breaker for the air conditioner. f Potential risk of electric shock or fire. Do not insert anything such as fingers or branches into the air conditioner vents while the air conditioner is running.
Page 6
Safety precautions SEVERE WARNING SIGNS WARNING Always make sure that the power supply is compliant with current safety standards. Always install the air conditioner in compliance with current local safety standards. Verify that the voltage and frequency of the power supply comply with the specifications and that the installed power is sufficient to ensure the operation of any other domestic appliance connected to the same electric lines.
Page 7
Do not allow children to climb on the air conditioner. Do not use the air conditioner as a cooling precision instrument for food, pets, plants, cosmetics or machinery. Do not pull or give excessive shock to the air conditioner. f Potential risk of fire, or unit malfunction and there are risk of personal injury because unit may fall down. Do not spray water directly on the air conditioner or use benzene, thinner or alcohol to clean the surface of the unit.
Page 8
Safety precautions CAUTION SIGNS CAUTION When using a wireless remote controller, the distance should not be more than 7 meters from the air conditioner. If the remote controller is not used for a long period of time, remove the batteries to prevent leakage of electrolyte.
Viewing your air conditioner Congratulations on the purchase of the air conditioner. We hope you enjoy the features of your air conditioner and stay cool with optimal effi ciency. Please read the manual to get started and to make the best use of the air conditioner. Checking the indoor unit and display Carefully unpack your air conditioner and check the indoor unit to make sure it is not damaged.
Viewing your air conditioner Control panel You can operate the air conditioner with the control panel when you can’t or don’t want to operate the air conditioner with the remote controller. (see pages 21.) Air swing (Up/Down) indicator Fan speed indicator Air swing (Left/Right) indicator Temperature setting Defrost indicator...
Checking the remote controller Remote controller buttons You can activate the air conditioner by pointing the remote controller away from it. When using the remote controller, always point it directly at the air conditioner. Vertical air swing Adjusts the air flow direction up and down (Not applicable to Duct type models).
Checking the remote controller Remote controller display Operation mode Remote controller *Heat mode is applicable to transmission AP50M1✴❋model only. Low battery Set temperature or on/off set time with the timer function Fan speed On/Off timer Air fl ow direction Options * These functions are not supported Single, Heater and Purity functions are not supported by this model.
Page 13
Battery changing time When the battery is exhausted,( )will be displayed in the remote controller display. When the icon appears, change the batteries. The remote controller requires two 1.5V AAA type batteries. Storing the remote controller When you do not use the remote controller for a long time, remove the batteries from the remote controller and store it in the remote controller holder.
Basic operation Basic operation is an operation mode that can be selected by pressing the Mode button. Auto In Auto mode, the air conditioner will automatically set the Operation(Cool/Heat Mode) and fan speed depending on the room temperature detected by the room temperature sensor. (Heat mode is applicable to AP50M1✴ model only.) Cool Cool mode is frequently used and you can freely control the temperature, fan speed, and air flow direction in cool mode.
Page 15
Turning on the power Press the button to turn on the air conditioner. Selecting the operation mode Press the button to set the operation mode. Selecting the fan speed Press the button to set the desired fan speed. Auto (Auto) Cool (Auto), (Med),...
Page 16
Basic operation Selecting air fl ow direction This function allows you to shift the air fl ow direction up and down or left and right. Press the button to move the air fl ow direction up and down or left and right while the air conditioner is turned on.
Setting the On/Off timer You can set the air conditioner to turn on/off automatically at desired time. Setting On timer while the air conditioner is off / Off timer while the air conditioner is on. When the air conditioner is off ; 1.
Page 18
Setting the On/Off timer When the air conditioner is on; 1. Press the Timer button to select (Off ). - (Off ) indicator starts to blink and you can set the time. 2. Press the < or > button to set the time. - You can set the time in 0.5 hour unit from 0.5 ~ 3 hours and 1 hour unit from 3~24 hours.
Using the Turbo function You can set the Turbo function to provide fast and powerful cooling (heating). When the air conditioner is operating in Cool or Heat mode; 1. Press the Turbo button. - (Turbo) will be displayed and the function will operate for 30 minutes. f Press the Turbo Button.
Using the Long function Long function will be helpful when you want the cool air to go to much further place. 1. Press the Options button. 2. Press the < , > or Options button until (Long) indicator starts to blink. 3.
Using the air conditioner with the control panel You can control the air conditioner without the remote controller. 1. Press the Power button on the indoor unit control panel. f The air conditioner will turn on with ringing sound. Stop To turn off the air conditioner, press the Power button again.
Cleaning and maintaining the air conditioner Make sure to turn off the circuit breaker when cleaning the air conditioner. CAUTION Cleaning the exterior 1. Wipe the surface of the unit with a slightly wet or dry cloth when needed. Do not use Benzene, Thinner or Clorox .
Maintaining your air conditioner If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best condition. 1. Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and turn off the circuit breaker. There may be internal damage if moisture is left in components.
Page 24
Cleaning and maintaining the air conditioner Internal protections via the unit control system This internal protection operates if an internal fault occurs in the air conditioner. Type Description Against cold air The internal fan will be off to against cold air when the heat pump is heating. Defrost cycle The internal fan will be off to against cold air when the heat pump is heating.
Appendix Troubleshooting Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses. PROBLEM SOLUTION The air conditioner does not operate • Because of the protective mechanism, the appliance does not start operating immediately after it has been immediately to keep the unit from overloading.
Appendix Operation ranges The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use. OPERATIONAL TEMPERATURE INDOOR MODE IF OUT OF CONDITIONS HUMIDITY INDOOR OUTDOOR Condensation may occur on the indoor COOLING 18˚C to 32˚C 21˚C to 52˚C...
This manual explains how to install an indoor unit with a split system with two SAMSUNG units. The use of other types of units with different control systems may damage the units and invalidate the warranty. The manufacturer shall not be responsible for damages arising from the use of non compliant units.
Page 28
Safety precautions f Do not use the air conditioner in environments with hazardous substances or close to equipment that release free flames to avoid the occurrence of fires, explosions or injuries. f Our units must be installed in compliance with the spaces indicated in the manual to ensure either accessibility from both sides or ability to perform routine maintenance and repairs.
Accessory parts list ❋ ❋ Product illustration may look diff erent from the actual product. Part Name Quantity Remarks Fixing bracket for indoor unit Remote controller Remote controller holder M4 X L12 screws M4 X L14 screws Batteries for remote controller Indoor unit Protective piping cover Insulation for piping...
Selection of installation place Indoor unit f Install the unit at a place close to the wall facing the outside as it is necessary to perform piping connection with the outdoor unit. - It is effective to install the unit at a window side to ensure uniform distribution of indoor temperature. f Install the unit at a place where there is no obstacle against the wind around the air intake and air outlet.
Page 31
Outdoor unit f A place free from the risk of combustible gas leakage. f A place which can bear the weight of the unit. f A place which can bear the fixing strength of the outdoor unit. f Avoid a place subject to oil (including machine oil). f Avoid a saline place.
Preparing the installation Selecting appropriate location for installation Decide the installation location based on the following condition and obtain the user’s approval. f Avoid a place that may disturb your neighbor. Noise may occur from the outdoor unit and the discharged air may run into the neighborhood.
If you install several outdoor units at the same place, observe the space for ventilation and free airflow. f If the space for ventilation is insufficient, the air conditioner may not generate performance designed. Keep in mind that SAMSUNG logo is located on the front side of outdoor unit. Mirage_AP50M0@_IBIM_EN_05323A-02.indd 33...
Electrical work The electrical work should be performed by a specialist qualified for the work. f Use the three phase power supply, and be sure to install the sub power distributing board for exclusive use with the unit (separately purchased by the user). ❋...
Page 35
Indoor and outdoor connection wiring f When connecting the wiring harness between the indoor and outdoor unit, align the outdoor side and the indoor side with the terminal board No. ❋ ❋ When the wiring harnesses of the indoor and outdoor unit are not properly connected, it may cause trouble. Be careful not to allow the indoor and outdoor wirings and power lines to get in contact with the service valve of the refrigerant system or to the pipe without an insulation.
Page 36
Electrical work AP50M1✴ Series Using 4poles ELCB(Earth Leakage Circuit Breaker) 1. Remove the cover of electric box on side panel of the outdoor unit. 2. Connect the electric input wires [L1(R), L2(S), L3(T), N] to each terminal [L1(R), L2(S), L3(T), N] of the electric box on the outdoor unit respectively.
Electrical wiring f Connect it to the terminal board N and L for power cable to the outdoor unit. In so doing, peel off the end of the power cord by about 5mm, and press the cord to the ring terminal for hooking. - Make sure to install exclusive power supply.
Installation method Outdoor unit When using the anchor bolt Fix the unit on a flat, rigid floor using the anchor bolt. Anchor bolt fixing dimensions (Anchor bolt : M10 x 4 points - separately purchased) 670mm When using the rubber leg Put the rubber leg to the outdoor unit leg.
Page 39
Indoor unit Indoor unit Outdoor unit Indoor unit Fix the pipe S-TRAP Outdoor Fix the (Every 10 m) Outdoor unit pipe unit 4. Install the high pressure pipe to the heat exchanger liquid pipe, and the low pressure pipe to the heat exchanger gas pipe respectively using the flare nut, taking care not to cause any leakage of refrigerant.
Page 40
Installation method Refrigerant pipe work Insulating the pipes f Make sure to insulated the refrigerant pipes with an insulation tape. If the Pipe insulator pipe is not insulated, condensate may form and drop into the indoor. Vinyl f Wind the refrigerant pipes and the drain hose with vinyl tapes. tape Indoor/ f When you bend the pipe, try to secure large bending radius (over 100 mm)
Page 41
Connection of refrigerant piping Flare processing 1. Cut the pipe using the pipe cutter. 90° Oblique Rough Burr 2. Remove burr on the edge of pipe. Pipe - If burr is not removed after cutting the pipe, there is a risk of refrigerant gas leakage. Reamer - If foreign substance such as burr goes into the pipe, there is a risk of product breakdown.
Page 42
Installation method Pipe bending 1. Perform bending of the pipe using the bender which has a specified bending radius. 2. Be sure to take full care to perform bending of the pipe successfully at Spring one time. Bending and unbending the pipe more than twice makes the bending work increasingly difficult.
Page 43
Drain hose 1. Connect the drain hose by inserting the extension drain hose to the drain connection port tightly. Drain hose 2. Insulate the extension drain hose, then fix it with a cable tie or a tape. Drain hole for duct (polypropylene) Vinyl chloride Piping material...
Air purge ❋ ❋ Be sure that all valve cocks are closed. f The air in the indoor unit and in the pipe must be purged. Make sure to vacuum inside of the connection pipe using vacuum pump after connecting pipes.(Use vacuum pump as shown at the figure.) If air remains in the refrigeration pipes, it will affect the compressor, reduce to cooling capacity and could lead to a malfunction.
Refrigerant charging How to add refrigerant 1. Connect manifold gauge to the gas side service valve. 2. Take the trial operation with the cooling trial operation mode. 3. Perform trial operation for longer than 10 minutes and add refrigerant based on the below pressure table. ❋...
Check and test operation Check f Be sure to check the following again after completion of installation. 1. Check the piping connection area for any gas leakage. Indoor connection area Outdoor connection area 2. Is the drain hose properly connected? 3.
Check and test operation Test operation f After checking, read the owner’s instructions carefully, and perform a test operation. Then deliver the unit to the customer. (When delivering the unit, be sure to read carefully and follow the contents of the owner’s instructions.) f Check if the indoor/outdoor unit’s connection wires are properly connected.
Packing and unpacking guide Indoor unit Cushion-top ① Cushion-mid ② Packing case ③ Indoor unit ④ Cushion-bottom ⑤ f Packing the unit as below procedure 1. Put the indoor unit ④ onto the cushion-bottom ⑤. 2. Assemble cushion-mid ② of indoor unit ④. 3.
Page 49
Packing and unpacking guide Outdoor unit Cushion-top ⑤ Outdoor unit ④ Packing case ① 4 screws ③ Wood palette ② f Packing the unit as below procedure 1. Fix the outdoor unit ④ and the wood palette ② by 4 screws ③. 2.
How to connect your extended power cables 1. Prepare the following tools: Tools Crimping pliers Connection sleeve (mm) Insulation tape Contraction tube (mm) Spec MH-14 20xØ6.5(HxOD) Width 19 mm 70xØ8.0 (LxOD) Shape 2. As shown in the figure, peel off the shields from the rubber and wire of the power cable.
Page 51
4. Using a crimping tool, compress the two points and flip it over and compress another two points in the same location. - The compression dimension should be 8.0. - After compressing it, pull both sides of the wire to make sure it is firmly pressed. f Method 1 f Method 2 Compression...
Page 52
Mirage_AP50M0@_IBIM_EN_05323A-02.indd 52 2016-05-19 오후 1:27:30...
Page 53
Mirage_AP50M0@_IBIM_EN_05323A-02.indd 53 2016-05-19 오후 1:27:30...