  • Page 2: Table Of Contents

    DELIVERY SET ....................TROUBLESHOOTING ..................12 SAFETY INSTRUCTIONS ................13 ELECTRICAL SCHEMATIC DIAGRAM OF THE VDI-MINI UNIT ..16 WARRANTY ....................INFORMATION CONCERNING DISPOSAL OF EQUIPMENT ....18 ACCEPTANCE CERTIFICATE ..............18 - 2 - PATON VDI SERIES ECO DC MMA...
  • Page 3: Ec Declaration Of Conformity

    February 2014 and 2014/30/EU Electromagnetic Compatibility of 26 February 2014. The CE mark above can be used under the responsibility of manufacturer. After completion of an EC declaration of conformity and compliance with all relevant EU Directives. - 3 - PATON VDI SERIES ECO DC MMA...
  • Page 4: General Information

    40%, which is more than enough for most works in household sector (workshops, fleets, etc.). The block for protection of overvoltage and undervoltage is installed in all Paton™ MMA branded models. Due to the increased frequency of the input voltage of the rectifier transformer of the welding unit, the weight and overall dimensions of the transformer are significantly reduced as compared with other welding units with similar characteristics.
  • Page 5: Technical Characteristics

    The basic advantages of the PATON™ welding unit are the following: The welding unit is protected against long-time fluctuations of power supply voltage and provides arc stabilization when the input voltage of the unit changes in the range of 170 V through 260 V.
  • Page 6: Controls And Connectors

    В (-) – The bayonet connector socket for connecting: the earthing cable in the manual arc welding mode (or the power cable for a welding electrode in some cases when special welding electrodes are used for welding); - 6 - PATON VDI SERIES ECO DC MMA...
  • Page 7: Setting The Welding Unit Into Operation

    Prevent ingress of metallic particles (for example, when grinding the weld) sucked by the unit ventilator. WARNING!!! After fall from a height, the welding unit might be a source of electrical shock. Install the unit on a firm stable surface. - 7 - PATON VDI SERIES ECO DC MMA...
  • Page 8: Connection To A Power Supply System

    When power switch 3 is set to position "I", the electrode is under voltage. Prevent the contact of the electrode with conducting or earthed parts, for example, the casing of the welding unit. - 8 - PATON VDI SERIES ECO DC MMA...
  • Page 9: Increased-Current Arc Starting Hot-Start

    This function may be disabled, for example, when welding sheet materials and when the welding unit is connected to a low-powered voltage source (the welding unit with this function enabled consumes additional power). t (s) Pic.3. Increased-current arc starting HOT-START - 9 - PATON VDI SERIES ECO DC MMA...
  • Page 10: Protection Against Electrode Sticking Anti-Stick

     When working in environment with excessive dust content, manually clean the passages for cooling air. WARNING! Purging of the unit from a short distance can result in damage of the electronic elements of the unit. - 10 - PATON VDI SERIES ECO DC MMA...
  • Page 11: Operation With An Electric Generator

    In this case, the parameter of an electrical outlet and power cable should be selected with consideration for the actual power supply voltage. - 11 - PATON VDI SERIES ECO DC MMA...
  • Page 12: Delivery Set

    260 V (the indicator on the rear power supply system with panel lights). proper voltage. Fault of the internal power Apply to the service center. supply module of the welding unit - 12 - PATON VDI SERIES ECO DC MMA...
  • Page 13: Safety Instructions

    Failure to follow the instructions in this manual may result in serious personal injury, death and damage to the unit itself. Incorrect installation, maintenance and operation resulting in damage to the device - the manufacturer is not liable. - 13 - PATON VDI SERIES ECO DC MMA...
  • Page 14 Firefighting equipment such as: (powder or snow fire extinguishers, fire blankets) should be located near the workstation in a visible, readily accessible place. - 14 - PATON VDI SERIES ECO DC MMA...
  • Page 15 SAFETY MARK: This device is suitable for mains power, for welding work in an environment of higher standard of electric shock. It is recommended that the power line be provided with a separate protection against the shock absorber. - 15 - PATON VDI SERIES ECO DC MMA...
  • Page 16: Electrical Schematic Diagram Of The Vdi-Mini Unit

    12. ELECTRICAL SCHEMATIC DIAGRAM BPK-0332 - 16 - PATON VDI SERIES ECO DC MMA...
  • Page 17: Warranty

    13. WARRANTY The Pilot Plant of Welding Equipment of the E.O PATON Electric Welding Institute guarantees the correct operation of the power supply if the costumers provided service conditions, storage and transportation. ATTENTION!!! Warranty commitments are cancelled in case of mechanical damage.
  • Page 18: Information Concerning Disposal Of Equipment

    Inverter rectifiers „PATON™ VDI-_________E” The serial number ______________ECO complies with the harmonized standards and is fit for use. Date of sale "___" ____________ 20___ year Stamp here _____________________ (signature of the seller) ================================================================================ - 18 - PATON VDI SERIES ECO DC MMA...
  • Page 19 ATTENTION!!! Delivery of the equipment to the service center "PATON" is performed at the manufacturer's expense only during the 1st of the year from the date of purchase! Over 1 year - at the buyer's expense.
  • Page 20 _______________________ (signature) Faults detected: __________________________________________________________________________________ __________________________________________________________________________________ Faulty-condition cause: __________________________________________________________________________________ __________________________________________________________________________________ __________________________________________________________________________________ __________________________________________________________________________________ Tel. Technical support: +48 889 226 032 Address of the service center: 38500, Poland, Sanok, Zamenhofa 9 Street ======================================================================= - 20 - PATON VDI SERIES ECO DC MMA...