Sign In
Upload
Manuals
Brands
YDOC Manuals
Data Loggers
ML-2013
YDOC ML-2013 Manuals
Manuals and User Guides for YDOC ML-2013. We have
2
YDOC ML-2013 manuals available for free PDF download: Manual, User Manual
YDOC ML-2013 Manual (120 pages)
ML-x15 series; WDL-x14 series. Low power 2G/3G data loggers
Brand:
YDOC
| Category:
Data Loggers
| Size: 2.92 MB
Table of Contents
Table of Contents
3
Product Description
10
Models and Editions
11
ML-X15
12
WDL-X14
14
Getting Started
16
Vibration
16
Do's and Don'ts
16
Inserting the SIM-Card
16
Power on for the First Time
17
Connect to a PC
17
Operating Basics
18
Configuration Menu
18
Reference
25
Principle of Operation
25
Sample Interval
25
Data Logging Interval
25
Send Interval
25
Send Delay
25
Example
26
Parameters
27
Name
27
Code
27
Unit
27
Value Factor
27
Value Offset
27
Decimals
27
Data Log
27
Data Transpond
28
Alarm Message
28
Alarm Log
28
Alarm Output
28
Alarm Limits and Delays
28
Configuration Menu Settings
29
Date & Time
29
System Information
29
Configuration Setup
30
General Settings
31
Exit
31
System Name
31
Datalog Interval
31
Timestamp Round down
31
Continuous Alarm Sampling
31
Alarm Output Port
32
Deployment Date and Time
32
Daily Operating Time Slot
32
Time Zone
32
Summer Time
32
Modem Settings
33
NTP Time Update
34
Time Update
34
Update Interval
34
Server
34
NTP Port
34
Time Update Test
34
Alarm Messages
34
System Alarm
34
Data Alarm
34
APN Login Test
34
SMS Commands
35
Acva Sms
35
Internal Sensors
35
Name
35
Sample Interval
35
Battery Capacity
35
Battery Replaced
35
Rest Capacity
35
Rest Power
35
Casing Pressure (WDL-X14 Only)
36
Casing Temperature (WDL-X14 Only)
36
Processor Temperature
36
Average Voltage
36
Max Voltage
36
Min Voltage
36
Average, Max, Min Current
36
Operating Cycle
36
Free Disk Space
36
Analog Sensors (Ma/V)
37
Sensor Power Switch
37
Sample Interval
37
Port Mode
37
Parameter Settings
37
Determine Linear Conversion Function (2 Calibration Points)
37
Determine Linear Offset Only (1 Calibration Point)
37
Digital Sensors- Pulse Input
38
Sample Interval
38
Port Mode
38
Pull up
38
Pull down
39
Register Mode
39
Units Per Pulse, or Pulses Per Unit
39
Register Value
39
Register Reset
39
Log each Counter Change
39
Counter
39
Quantity
39
Mean-, Max- and Min Rate
39
Digital Sensors- Alarm Input
40
Trigger Delay
40
Register Value
40
Network Signal Sensor
41
Independent Data Log
41
Signal Bars
41
Signal Db/%/Indication/Bit Error Rate
41
Aggregation Channels
42
Calculation Channels
43
Example 1
44
Sin(Radians)
45
Supported Comparisons with 2 Arguments
46
Serial Port
47
Start Command
48
Generic Serial
49
Example
50
Field Position
50
Field Type
50
Generic NMEA
50
Parameters
50
Gps
51
Rs485
51
Measurement Command
51
Parameters
51
Accessory Port
52
Radio
52
Power down Delay
52
Send Delay
52
Send Interval
52
Iridium Satellite
53
Iridium SBD Service
53
Backup Mode
54
Data Transpond
54
Message Format
54
Send Interval
54
Settings Menu
54
Gps
55
Minimum Satellites to Use
55
Position Drift Alarming
55
Time to Fix
55
Calculate Alarm Limits on Deployment
56
GPS Quality
56
Latitude / Longitude
56
Latitude/Longitude Hi/Lo Alarm Drift
56
Satellites
56
Camera
57
Display
58
Power down Delay
58
DTU Connection
59
Port Settings
60
Sensor Power Switch
60
Connect Interval
60
Connection Delay
60
Server
60
TCP Port
60
Client ID
60
Termination ID
60
Terminal Request ID
60
Email Output
61
Server
61
SMTP Port
61
Originator Address
61
Destination Address
61
Data Format
61
Remote Configuration
61
FTP Output
62
Server
62
Port
62
FTP Mode
62
Security
62
Directory
62
Omit Timestamp
62
Data Format
62
Remote Configuration
63
HTTP Output
64
Server
64
TCP Port
64
Security
64
Data Format
64
Remote Configuration Transfer and Firmware Upgrade
64
Remote Configuration
65
MQTT Output
66
Server
66
Port
66
Root Topic
66
Security
67
Data Output
67
Data Format
67
Remote Configuration Transfer and Firmware Upgrade
67
Remote Configuration
68
TCP Output
69
Server
69
Port
69
Security
69
Data Format
69
Satellite Output (SBD)
69
Configuration Review
70
Parameter List
70
Measurement List
70
Alarm List
71
Alarm Limits
71
Maintenance Menu
72
Field Testing
72
Digital Input Test
72
Verify Analog Inputs
72
Battery Test
73
Comport Redirect
73
SD Card Test
73
Configuration Down/Upload
74
Data Download
74
Format SD Card
74
Bootloader Menu
75
Firmware Upgrade
75
Modem Maintenance
75
Hardware
76
Wiring
76
Baud Rate and Frame Format
76
Sdi-12
76
Rs232
77
Rs485
77
Analog Inputs (4
79
Loop Powered Devices
79
Analog Inputs (0
79
Analog Differential Inputs (ML-2013 Only)
79
Differential Input Ports Theory of Operation
79
Common Mode Noise Rejection
79
Using Load Cells with the ML-2013
80
Bridge of Wheatstone
80
Analog Differential Input 5
81
Potentiometer Input (ML-X15 Only)
82
Digital Inputs
83
Alarming
84
Advanced Alarming
86
Firmware Upgrade
87
Power Switch Limitations
88
Inserting an SD-Card
89
D-Records
90
Data Modifiers
91
JSON Data Format
92
Compacted Data Format
93
Records
94
Time-Record
95
Input-Drivers
96
Digital Pulse Sensor
97
Counter
98
Rate
99
Power Supply
100
Pin Configuration
101
ML-X15
102
WDL-X14
103
Pin Descriptions
104
Digital Inputs
105
Maintenance and Repair
106
Safety
107
Environment and Disposal
108
Transport and Storage
109
Appendix
110
CE Declarations of Conformity
111
Supported Serial Sensor Devices
114
Open Collector Output
117
Trouble Shooting
118
System Messages
119
Advertisement
YDOC ML-2013 User Manual (45 pages)
Low power GPRS data logger
Brand:
YDOC
| Category:
Data Loggers
| Size: 2.54 MB
Table of Contents
Table of Contents
3
1 Product Description
5
Editions
6
2 Getting Started
8
Vibration
8
Do's and Don'ts
8
Inserting the SIM-Card
8
Power on for the First Time
9
Connect to a PC
9
3 Operating Basics
10
Configuration Menu
10
4 Reference
16
Principle of Operation
16
Sample Interval
16
Data Logging Interval
16
Send Interval
16
Example
16
Sdi-12
17
SDI-12 Hardware
17
SDI-12 Wiring
17
SDI-12 Baud Rate and Frame Format
18
Analog Inputs (4
20
Loop Powered Devices
20
Analog Differential Inputs (ML-2013 Only)
20
Differential Input Ports Theory of Operation
20
Common Mode Noise Rejection
20
Using Load Cells with the ML-2013
20
Bridge of Wheatstone
21
Excitation Output
21
Analog Differential Input 5
22
Analog Differential Input 6
22
Calibration of Differential Inputs
22
Overall Calibration
22
Digital Inputs
23
Pull up Type
23
Pull down Type
23
Coil Input
23
Alarming
24
Alarming - Principal of Operation
24
Firmware Upgrade
25
When to Use Firmware Upgrades
25
Firmware Upgrade Procedure
25
Firmware Upgrade over the Air
26
Firmware Driver Limitations
26
Power Switch Limitations
26
Modem
26
Modem Firmware Upgrade
26
SD-Card
27
Inserting an SD-Card
27
Data Format
27
Header
27
Parameter Code
28
Parameter Name
28
Parameter Unit
28
D-Records
28
Parameter Value
28
System-Records
29
System Message
29
Additional System Message
29
Data Modifiers
29
Transmission of the Data Log File
30
Input-Drivers
30
Analog Sensors
30
Digital Pulse Sensor
31
Example Configuration Rain Measurement
31
Counter
32
Quantity
32
Rate
32
Power Supply
33
Internal RTC Backup Battery
33
Power Consumption & Battery Life
33
5 Pin Configuration
34
Pin Description
36
Analog Inputs
36
Analog Input 1 to 4
36
Analog Input 5 to 8 (ML-2013 Only)
36
Rs 485 a & B
36
Power Switch
36
Vbat
36
RX & TX COM 1 & Com 3
36
SDI-12 Hi
36
Digital Inputs
36
Antenna Placement and Field Strength
37
6 Maintenance and Repair
37
RTC Lithium Battery Replacement
37
Recalibration
38
Xray
38
7 Safety
38
Power Supply
38
Esd
38
8 Environment and Disposal
39
9 Transport and Storage
39
10 Specifications
40
11 EU Declaration of Conformity
41
12 Supported Serial Transponders
43
13 Trouble Shooting
44
Customer Response Form
45
Advertisement
Related Products
YDOC ML-2012/13
YDOC ML-2013-DC
YDOC ML-2013-PV
YDOC ML-2013-TFT
YDOC ML-2012
YDOC ML-OI-AD-20MA
YDOC ML-OI-AX-RH
YDOC ML-OA-WIFI
YDOC ML-OI-COM-RS485
YDOC ML-OI-COM-UART
YDOC Categories
Data Loggers
More YDOC Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL