Sign In
Upload
Manuals
Brands
Samsung Manuals
Air Conditioner
AM048FXMDCH
Samsung AM048FXMDCH Manuals
Manuals and User Guides for Samsung AM048FXMDCH. We have
3
Samsung AM048FXMDCH manuals available for free PDF download: Service Manual, Installation Manual
Samsung AM048FXMDCH Service Manual (101 pages)
System Air Conditioner
Brand:
Samsung
| Category:
Air Conditioner
| Size: 2.68 MB
Table of Contents
Table of Contents
2
Precautions
4
Precautions for the Service
4
Precautions for the Static Electricity and PL
4
Precautions for the Safety
4
Precautions for Handling Refrigerant for Air Conditioner
5
Precautions for Welding the Air Conditioner Pipe
5
Precautions for Additional Supplement of Air Conditioner Refrigerant
5
Other Precautions
5
Product Specifications
6
The Feature of Product
6
Feature
6
Product Specifications
12
Disassembly and Reassembly
13
Necessary Tools
13
Disassembly and Reassembly
14
Am036/048/053Fxmdch
14
Am060Mxmdch
23
Troubleshooting
33
Error Display
33
Error Code
34
Appropriate Measures for Different Symptom
36
Error Due to Repeated Address Setting (E-108)
36
Communication Error between Indoor and Outdoor Unit (E-201)
37
Communication Error on All PBA Within the Outdoor Unit C-Box, Communication Cable Error. (E-205)
39
Error on Outdoor Temperature Sensor of Outdoor Unit (Short or Open). (E-221)
40
Error on COND out Temperature Sensor of Main Outdoor Unit (Short or Open). (E-231)
41
Error on Discharge Temperature Sensor of Compressor 1 (Short or Open). (E-251)
42
Discharge Temperature Sensor of Compressor 1 Is Detached from the Sensor Holder on the Pipe. (E-262) / Top Sensor of Compressor 1 Is Detached (E-266)
43
Suction Temperature Sensor Is Detached from the Sensor Holder on the Pipe. (E-269)
44
Refrigerant Leakage or Error on High Pressure Sensor (Short or Open). (E-291)
45
Refrigerant Leakage or Error on Low Pressure Sensor (Short or Open). (E-296)
46
Error on Suction Temperature Sensor (Short or Open). (E-308)
47
Error on Temperature Sensor of Double Layer Pipe
48
Liquid Pipe(Sub Heat Exchanger) (Short or Open). (E-311)
48
Error on EVI (ESC) in Temperature Sensor (Short or Open). (E-321)
49
Error on EVI (ESC) out Temperature Sensor(Short or Open). (E-322)
50
Error Due to Operation Failure of Fan1 (E-446)
51
Lock Error on Fan1 of Outdoor Unit. (E-448)
53
Error Due to Overheated Motor of Outdoor Unit's Fan1. (E-453)
54
Error Due to Overheated IPM of Fan1. (E-455)
55
Output Current Sensor Error of Inverter PBA 1. (E-468) Error Due to Input Current of Inverter 1. (E-485)
56
DC Voltage Sensor Error of Inverter PBA 1. (E-469)
57
Compressor Operation Stop Due to High Pressure Protection Control. (E-407)
58
Compressor Operation Stop Due to Low Pressure Protection Control or Refrigerant Leakage. (E-410)
59
Compressor Operation Stop Due to Discharge Temperature Protection Control. (E-416)
61
Phase Reversal or Phase Failure(3Ø Outdoor Unit Wiring, R-S-T-N), Connection Error on 3 Phase Input. (E-425)
63
Phase Reversal or Phase Failure(3Ø Outdoor Unit Wiring, R-S-T-N), Connection Error on 3 Phase Input. (E-428)
65
EVI (ESC) EEV Leakage or Internal Leakage of Intercooler or Incorrect Connector Insertion of EVI (ESC) EEV. (E-438)
67
Error Due to Refrigerant Leakage. (E-439) / Operation Prohibited Due to Low Pressure. (E-443)
69
Heating Mode Restriction Due to High Air Temperature. (E-440) Operation Prohibited Due to Low Pressure. (E-441)
70
Refrigerant Charging Restriction in Heating Mode When Air Temperature Is over 15°C. (E-442)
71
CCH Is Detached. (E-445)
72
Error Due to Operation Failure of Inverter Compressor 1. (E-461)
73
Error Due to Operation Failure of Inverter Compressor 1. (E-464)
74
Error Due to over Voltage / Low Voltage of Inverter PBA 1. (E-466)
75
Error Due to Overheat Caused by Contact Failure on IPM of Inverter PBA 1. (E-500)
76
Outdoor Unit's Option Switch Setting Error. (E-560)
77
PCB Diagram and Parts List
78
Outdoor Unit PCB
78
Wiring Diagram
86
Am036/048/053Fxmdch
86
Am060Mxmdch
87
Reference Sheet
88
Refrigerant Cycle Diagram
88
Am036/048/053Fxmdch
88
Am060Mxmdch
89
Nomenclatures
90
Check Operation & Amount of Refrigerant Automatically Checking
91
Check Operation
91
How to Troubleshoot of the "Undetermined
93
Automatic Refrigerant Amount Detection Function (Checking Th Amount of Refrigerant)
100
Advertisement
Samsung AM048FXMDCH Service Manual (65 pages)
SYSTEM AIR CONDITIONER
Brand:
Samsung
| Category:
Air Conditioner
| Size: 1.76 MB
Table of Contents
Table of Contents
2
Product Specifications
3
The Feature of Product
3
Product Specifications
9
Disassembly and Reassembly
10
Troubleshooting
20
Error Display
20
Error Code
21
How to Take Measures for each Symptom
22
Communicaion Error between Indoor and Outdoor Units During Tracking(Error Code:e201)
22
Outdoor Units (Error Code:e203)
24
Outdoor Temperature Sensor Error (Error Code : E221, E231, E251, E269)
25
High Pressure Temperature Sensor Error (Open/Short) (Error Code : E291) Low Pressure Temperature Sensor Error (Open/Short) (Error Code : E296)
26
Compressor down by Antifreeze Control (Error Code: E403)
27
Comp. down Due to a Protective Control of High Pressure (Error Code : E407)
28
Comp. down Due to a Protective Control of Low Pressureerror Code : E410)
29
Comp. down Due to a Discharge Temperature Sensor of a Compressor (Error Code : E416)
30
Reverse Phase Detection Error (3Phase Outdoor Unit) (Error Code : E425)
31
ESC EEV Open Error (Error Code : E438)
32
Refrigerant Leakage Error (Error Code : E439)
33
Prohibition of the Compressor Operation Due to Outdoor Temperature (Error Code : E440, 441)
34
Refrigerant Leakage Error (During Operation) (Error Code : E443)
34
Outdoor Unit Fan Error (Error Code : E458, 475)
35
Comp down Due to OLP Temperature Control (Error Code : E463)
36
Compressor Starting/Rotation Error (Error Code : E461, E467)
37
Current Error / PFC Overload Error (Error Code : E462, E484)
39
IPM over Current Error (Error Code : E464)
40
DC-Link Voltage Under/Over Error (Error Code : E466)
43
Gas Leak Error (Error Code : E554)
45
Others
47
PCB Diagram
48
Wiring Diagram
52
Reference Sheet
53
Refrigerant Cycle Diagram
53
Nomenclature
54
Check Operation & Amount of Refrigerant Automatically Checking
55
Check Operation
55
Automatic Commissioning Error Code
63
Amount of Refrigerant Automatically Checking
64
Samsung AM048FXMDCH Installation Manual (50 pages)
Brand:
Samsung
| Category:
Air Conditioner
| Size: 7.71 MB
Table of Contents
Air Conditioner
2
Installation Manual
2
Table of Contents
3
Safety Precautions
4
General Information
4
Outdoor Unit Type
6
Installation Combination
6
Deciding to Where to Install the Outdoor Unit
7
Installation Location
9
When Installing more than 1 Outdoor Unit
10
Installation and Base Ground Work for an Outdoor Unit
11
Refrigerant Pipe Installation
13
Cutting or Flaring the Pipes
16
Connecting the Drain Hose to the Outdoor Unit
28
Wiring Work
32
Grounding Work
37
Setting Outdoor Unit Option Switch and Key Function
38
Pump down
43
Checking Lists after Finishing Installation
45
Inspection and Check Operation
46
Check Operation
47
Automatic Refrigerant Amount Detection Function (Checking Th Amount of Refrigerant)
48
Trial Operation
49
Advertisement
Advertisement
Related Products
Samsung AM048FN4DCH/AA
Samsung AM048FNLDCH/AA
Samsung AM048FNMDCH/AA
Samsung AM048FNHDCH/AA
Samsung AM048KXWDCH
Samsung AM048JNCDCH
Samsung AM048NN4DCH Series
Samsung AM048TXMDCH
Samsung AM048JNZDAA
Samsung AM048KN4DCH/AA
Samsung Categories
Cell Phone
Monitor
Microwave Oven
Air Conditioner
LCD TV
More Samsung Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL