User Manuals: IDS IDS-iSYS Automated System
Manuals and User Guides for IDS IDS-iSYS Automated System. We have
1
IDS IDS-iSYS Automated System manual available for free PDF download: User Manual
IDS IDS-iSYS User Manual (263 pages)
Vitro diagnostic analyser
Brand:
IDS
| Category:
Measuring Instruments
| Size: 7.55 MB
Table of Contents
Table of Contents
8
Section 1 Operating Principle
13
1-1- Field of Use
14
Operating Principle
15
1-2- General Overview
16
1-3- Characteristics
20
1-4- Installation
23
1-4-1- Environment
23
1-4-2- Electricity Supply
24
1-4-3- Connections
24
1-5- Operating Principles
25
1-5-1- Luminescence Measurements
25
1-5-2- Absorbancy Measurements
25
1-5-3- Immunoassays
26
1-5-4- Biochemistry Assays
27
1-6- Precautions for Use
28
1-6-1- General Precautions
28
1-6-2- Special Precautions
29
1-6-3- Safety Precautions
29
Section 2 User Interface Software
30
2-1- Structure of the Software
32
User Interface Software
32
2-2- Main Screen
33
2-3- Menus
39
2-3-1- FILE Menu
39
2-3-2- SESSIONS Menu
40
2-3-3- DATA Menu
41
2-3-4- MAINTENANCE Menu
42
2-3-4- MAINTENANCE Menu (Continued)
43
2-3-5- SETUP Menu
44
2-3-6- MANAGEMENT of LOTS Menu
45
2-3-7- HELP Menu
46
2-4- Functions Keys
47
Section 3 Use
48
Information on the Lid Opening
50
Use
50
3-1- Start up
52
3-1-1- Initial Start up
52
3-1-2- Start up from Standby Mode
52
3-2- Installation of Reagents
53
3-2-1- Colour Codes Associated with Reagent Positions in the Reagent Compartment
58
3-2-2- Information Displayed with Reagents
58
3-2-3- Management of on Board Reagents
59
3-3- Installation of Ancillary Reagents
61
3-3-1- Installation of Internal Ancillary Reagents
62
3-3-2- Installation of External Ancillary Reagents
63
3-3-3- Installation of IDS-Isys Cuvettes
65
3-4- System Performance Checks (Immunoassay Only)
67
3-4-1- Programming the Qualification Profile
67
3-4-2- Management of Results
68
3-5- Programming Calibrations and Controls
70
3-5-1- Programming Calibrations
70
3-5-2- Programming Quality Controls
73
3-6- Loading of Calibrators, Controls or Samples in the Sample Compartment
75
3-6-1- Removable Trays
76
3-6-2- Fixed Tray
79
3-6-3- Configure a Position Without Barcode
80
3-6-4- End of Loading
81
3-6-5- Colour Codes Associated with Sample Positions
82
3-6-6- Colour Codes Associated with Removable Trays
82
3-6-7- Colour Codes Associated with Position Contour
83
3-7- Programming Samples
84
3-8- Assays
85
3-8-1- Performing Assays
85
3-8-2- Adding Samples During an Assay
86
3-8-3- Adding or Replacing a Reagent During an Assay
87
3-8-4- Releasing an Alarm During an Assay
88
3-8-5- Unloading Samples During an Assay
90
3-8-6- Performing Reflex Tests
91
3-8-7- Performing Dilutions
92
3-9- Adding an Emergency (STAT) Sample
94
3-10- Results
95
3-10-1- Result of a Calibration
96
3-10-2- Result of Controls
100
3-10-3- Sample Results
101
3-10-4- Work List Results
102
3-11- Messages Associated with Results
104
3-12- Results Storage
108
3-13- Quality Control Management
110
3-13-1- Cumulative Analysis
110
3-13-2- Westgard Rules
113
3-14- Switching the Analyser Off
115
3-14-1- Emptying the Solid Waste
116
3-14-2- Emptying the Liquid Waste
117
3-15- Switching the Analyser Off Completely
118
Section 4 Messages
119
4-1- Messages Associated with Calibrations
121
Messages
121
4-2- Messages Associated with Calibration Controls
123
4-3- Messages Associated with Results
124
4-4- Warning Messages
128
4-5- Error Messages
129
Section 5 Maintenance
130
5-1- Daily Maintenance
132
Maintenance
132
5-1-1- General Maintenance
133
5-1-1-1- Checking Reagent Drawer and Plexiglas
133
5-1-1-2- Checking Sample Drawer and Plexiglas
133
5-1-1-3- Cleaning Needle Exterior
134
5-1-1-4- Decontamination of the Probe
134
5-2- Weekly Maintenance
135
5-2-1- General Maintenance
136
5-2-1-1- Cleaning the Reagent Compartment and Plexiglas
136
5-2-1-2- Cleaning the Sample Tray and Plexiglas
136
5-2-1-3- Cleaning the Rinsing Well
137
5-2-1-4- Checking Dilutors and IDS-Isys System Liquid Pumps
137
5-2-2- Immunoassay Maintenance
138
5-2-2-1- Rinsing of the IDS-Isys Triggers Tubing
138
5-3- Monthly Maintenance
139
5-3-1- General Maintenance
139
5-3-1-1- Cleaning the IDS-Isys System Liquid Pump Shafts
139
5-3-1-2- Cleaning the Liquid Waste Pump Shaft
139
5-3-1-3- Cleaning the IDS-Isys D-Sorb Pump and Level Sensor Shafts
140
5-3-1-4- Cleaning the Liquid Waste Level Sensor
140
5-3-1-5- Checking Lamp References
141
5-3-1-6- Switch off the Instrument
141
5-3-2- Immunoassay Maintenance
141
5-3-2-1- Cleaning the IDS-Isys Wash Solution Pump and Level Sensor Shafts
141
5-3-2-2- Rinsing of the AP Substrate Tubing
142
5-4- Analyser Interventions
143
5-4-1- Replacement of Lamp
143
5-4-2- Replacement of Probe
144
5-4-3- Replacement of Primary Fuses
145
5-4-4- Replacement of Secondary Fuses
146
5-4-5- Replacement of IDS-Isys Wash Solution Pump (Immunoassay)
147
5-4-6- Replacement of IDS-Isys System Liquid Pump
147
5-4-7- Replacement of Liquid Waste Pump
147
5-4-8- Replacement of IDS-Isys D-Sorb Pump
148
5-4-9- Removal of the On-Board IDS-Isys Cuvettes Cube
148
5-4-10- Adjustment of Probe Reference Position
149
5-4-10-1- Adjustment Procedure for Analyser Without Lid Locking System
150
5-4-10-2- Adjustment Procedure for Analyser with Lid Locking System
153
5-4-11- Unclogging the Sampling Probe
158
5-4-12- Intervention in System Configuration Menu
160
Section 5 Maintenance
160
5-4-13- Repeat an Automatic Maintenance
162
5-4-13-1- Washer Needle Cleaning
162
5-4-13-2- Cleaning the Probe
162
5-5- Analyser Cleaning
163
5-5-1- Decontaminating the Containers of Solid and Liquid Waste
164
Section 6 Problems & Corrective Action
165
Resolving Errors in Cartridge Check System (CCS)
167
Section 7 System Configuration
169
7-1- Programming the Automatic Qualification Profile
171
System Configuration
171
7-2- Creating the Reflex Tests
172
7-2-1- Creating a New Rule
173
7-2-2- Launch Option of Reflex Tests
175
7-2-3- Modifying an Existing Rule
176
7-2-4- Importing/Exporting Rules
176
7-2-5- Removing a Rule
176
7-3- Configuring the Print Settings
177
7-4- Options of Validating and Transferring the Results
178
7-5- User Management
179
7-6- Updating the Analytical Configuration
181
Appendices a
183
Waste Disposal a
184
Decontaminating the Analyser a
185
Cleaning/Decontaminating Declaration a
186
Disposal of the Analyser a
187
IDS-Isys User Manual - Revision M1
187
1- Versions of ASTM Protocol
199
2- ASTM Compatible Version
200
2-1- General Information
200
2-2- the Header Block
202
2-3- the Patient Block
203
2-5- the Result Block
208
2-6- the Request Information Block
210
2-7- the Message Terminator Block
212
2-8-1-Equipment Configuration
213
2-8-2-Change to Connection Setup
213
3- ASTM Compatible V2 Version
215
3-1- General Information
215
3-2- the Header Block
217
3-3- the Patient Block
218
3-5- the Result Block
223
3-6- the Comment Block
225
3-7- the Manufacturer Information Block
226
3-8- the Request Information Block
228
3-9- the Message Terminator Block
230
3-10-1-Equipment Configuration
231
3-10-2-Change to Connection Setup
231
3-10-3-Transferring Quality Control Results
233
4- ASTM Compatible V3 Version
234
4-1- General Information
234
4-2- the Header Block
236
4-3- the Patient Block
237
4-5- the Result Block
242
4-6- the Comment Block
244
4-7- the Manufacturer Information Block
245
4-8- the Request Information Block
247
4-9- the Message Terminator Block
249
4-10-1-Equipment Configuration
250
4-10-2-Change to Connection Setup
250
4-10-3-Transferring Quality Control Results
252
6- Examples of Data Transfer
254
6-1- Data Transferred by the LIS
255
6-2- Data Transferred to the LIS with ASTM Compatible Version
257
6-3- Data Transferred to the LIS with ASTM Compatible V2 Version
258
6-3- Data Transferred to the LIS with ASTM Compatible V3 Version
259
Advertisement
Advertisement
Related Products
IDS IDS805
IDS IDS1600
IDS IDS1200
IDS IDS400
IDS IDS806
IDS Categories
Security System
Keypad
Digital Camera
Control Unit
Control Panel
More IDS Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL