Sign In
Upload
Manuals
Brands
GE Manuals
Control Systems
C70
GE C70 Manuals
Manuals and User Guides for GE C70. We have
7
GE C70 manuals available for free PDF download: Instruction Manual, Communications Manual
GE C70 Instruction Manual (708 pages)
Capacitor Bank Protection and Control System UR Series
Brand:
GE
| Category:
Controller
| Size: 10.95 MB
Table of Contents
Table of Contents
3
1 Getting Started
11
Important Procedures
11
Cautions and Warnings
11
Inspection Procedure
12
Ur Overview
13
Introduction to the Ur
13
Hardware Architecture
13
Software Architecture
14
Enervista Ur Setup Software
15
System Requirements
15
Installation
15
Configuring the C70 for Software Access
16
Using the Quick Connect Feature
19
Connecting to the C70 Relay
24
Setting up Cybersentry and Changing Default Password
25
Ur Hardware
26
Mounting and Wiring
26
Communications
26
Faceplate Display
26
Using the Relay
27
Faceplate Keypad
27
Menu Navigation
27
Menu Hierarchy
27
Relay Activation
28
Relay Passwords
28
Flexlogic Customization
28
Commissioning
29
2 Product Description
31
Introduction
31
Overview
31
Security
33
Iec 870-5-103 Protocol
37
Order Codes
38
Overview
38
Order Codes with Enhanced Ct/Vt Modules
38
Order Codes with Process Bus Modules
40
Replacement Modules
43
Signal Processing
45
Ur Signal Processing
45
Specifications
47
Protection Elements
47
User-Programmable Elements
50
Monitoring
51
Metering
51
Inputs
52
Power Supply
53
Outputs
53
Communication Protocols
55
Inter-Relay Communications
55
Environmental
56
Type Tests
57
Production Tests
57
Approvals
58
Maintenance
58
3 Hardware
59
Description
59
Panel Cutout
59
Rear Terminal Layout
65
Wiring
66
Typical Wiring
66
Dielectric Strength
67
Control Power
67
Ct/Vt Modules
68
Process Bus Modules
70
Contact Inputs and Outputs
70
Transducer Inputs/Outputs
78
Rs232 Faceplate Port
80
Cpu Communication Ports
80
Irig-B
83
Direct Input/Output Communications
84
Description
84
Fiber: Led and Eled Transmitters
85
Interface
86
Rs422 Interface
89
Ieee C37.94 Interface
91
4 Human Interfaces
95
Enervista Ur Setup Interface
95
Introduction
95
Creating a Site List
95
Enervista Ur Setup Overview
95
Enervista Ur Setup Main Window
97
Extended Enervista Ur Setup Features
99
Settings Templates
99
Securing and Locking Flexlogic Equations
103
Settings File Traceability
105
Faceplate Interface
108
Faceplate
108
Led Indicators
109
Custom Labeling of Leds
112
Display
117
Keypad
117
Breaker Control
117
Menus
118
Changing Settings
121
5 Settings
122
Overview
125
Settings Menu
125
Introduction to Elements
128
Introduction to Ac Sources
129
Product Setup
132
Security
142
Display Properties
148
Clear Relay Records
149
Communications
150
Modbus User Map
188
Real Time Clock
188
User-Programmable Fault Reports
193
Oscillography
194
Data Logger
196
User-Programmable Leds
198
User-Programmable Self Tests
201
Control Pushbuttons
202
User-Programmable Pushbuttons
204
Flex State Parameters
210
User-Definable Displays
210
Direct Inputs and Outputs
213
Installation
220
Remote Resources Configuration
221
System Setup
222
Ac Inputs
222
Power System
223
Signal Sources
225
Breakers
228
Disconnect Switches
232
Flexcurves
235
Flexlogic
242
Introduction to Flexlogic
242
Flexlogic Rules
254
Flexlogic Evaluation
254
Flexlogic Example
255
Flexlogic Equation Editor
259
Flexlogic Timers
259
Flexelements
260
Non-Volatile Latches
265
Grouped Elements
266
Overview
266
Setting Group
266
Breaker Failure (Ansi 50Bf)
266
Phase Current
266
Neutral Current
266
Ground Current
266
Negative Sequence Current
266
Voltage Elements
311
Control Elements
330
Overview
330
Trip Bus
330
Setting Groups
332
Selector Switch
334
Time of Day Timers
340
Capacitor Control
341
Automatic Voltage Regulator
346
Digital Elements
351
Digital Counters
354
Monitoring Elements
356
Inputs and Outputs
369
Contact Inputs
369
Virtual Inputs
371
Contact Outputs
372
Virtual Outputs
375
Remote Devices
375
Remote Inputs
377
Remote Double-Point Status Inputs
378
Remote Outputs
378
Resetting
379
Direct Inputs and Outputs
380
Iec 61850 Goose Analogs
383
Iec 61850 Goose Integers
384
Transducer Inputs and Outputs
385
Dcma Inputs
385
Rtd Inputs
386
Dcma Outputs
388
Testing
391
Test Mode
391
Force Contact Inputs
392
Force Contact Outputs
393
Advertisement
GE C70 Instruction Manual (702 pages)
Capacitor Bank Protection and Control System
Brand:
GE
| Category:
Protection Device
| Size: 26.25 MB
Table of Contents
Table of Contents
3
1 Introduction
11
Safety Symbols and Definitions
11
General Cautions and Warnings
11
For Further Assistance
12
2 Product Description
15
Description
16
Security
17
Order Codes
22
Order Codes with Enhanced CT/VT Modules
22
Order Codes with Process Bus Modules
24
Replacement Modules
27
Signal Processing
29
UR Signal Processing
29
Specifications
31
Protection Elements
32
User-Programmable Elements
37
Monitoring
38
Metering
39
Inputs
40
Power Supply
41
Outputs
42
Communications
44
Inter-Relay Communications
45
Cybersentry Security
46
Graphical Front Panel
46
Environmental
47
Type Tests
48
Production Tests
48
Approvals
49
Maintenance
49
3 Installation
51
Unpack and Inspect
51
Panel Cutouts
52
Horizontal Units
52
Vertical Units
56
Rear Terminal Layout
61
Wiring
64
Typical Wiring
64
Dielectric Strength
65
Control Power
65
CT/VT Modules
66
Process Bus Modules
68
Contact Inputs and Outputs
69
Transducer Inputs and Outputs
81
RS232 Port
83
CPU Communication Ports
84
Irig-B
86
Direct Input and Output Communications
87
Description
87
Fiber: LED and ELED Transmitters
89
Interface
89
RS422 Interface
93
IEEE C37.94 Interface
95
Activate Relay
98
Install Software
99
Enervista Communication Overview
99
System Requirements
100
Install Software
101
Add Device to Software
102
Set IP Address in UR
103
Configure Serial Connection
108
Configure Ethernet Connection
110
Configure Modem Connection
111
Automatic Discovery of UR Devices
111
Connect to the C70
112
Connect to the C70 in Enervista
112
Use Quick Connect Via Front RS232 Port
113
Use Quick Connect Via Front USB Port
114
Use Quick Connect Via a Rear Ethernet Port
114
Set up Cybersentry and Change Default Password
115
Import Settings
116
Connect to D400 Gateway
117
Oscillography Files
117
Event Records
117
Log Files
117
Setting Files
118
4 Interfaces
119
Enervista Software Interface
119
Introduction
119
Settings Files
119
Event Viewing
120
File Support
121
Enervista Main Window
121
Protection Summary Window
122
Settings Templates
123
Secure and Lock Flexlogic Equations
127
Settings File Traceability
130
Front Panel Interface
133
Front Panel
133
Front Panel Display
135
Front Panel Navigation Keys
155
LED Indicators
156
Front Panel Labelling
161
Menu Navigation
167
Change Settings
169
View Actual Values
174
Breaker Control
175
Change Passwords
176
Invalid Password Entry
177
Logic Diagrams
177
Flexlogic Design Using Engineer
179
Design Logic
181
Send File to and from Device
191
Monitor Logic
192
View Front Panel and Print Labels
193
Generate Connectivity Report
194
Preferences
194
Toolbars
198
5 Settings
205
Settings Menu
205
Overview
208
Introduction to Elements
208
Introduction to AC Sources
209
Product Setup
211
Security
211
Display Properties
229
Graphical Front Panel
231
Clear Relay Records
243
Communications
244
Modbus User Map
311
Real-Time Clock
311
User-Programmable Fault Report
316
Oscillography
317
Data Logger
319
User-Programmable Leds
321
User-Programmable Self Tests
325
Control Pushbuttons
325
User-Programmable Pushbuttons
327
Flex State Parameters
332
User-Definable Displays
333
Direct Inputs and Outputs
335
Teleprotection
341
Installation
342
Remote Resources
342
Remote Resources Configuration
342
System Setup
344
AC Inputs
344
Power System
345
Signal Sources
346
Breakers
348
Disconnect Switch Control
354
Flexcurves
359
Flexlogic
366
Flexlogic Operands
366
Flexlogic Rules
381
Flexlogic Evaluation
381
Flexlogic Example
382
Flexlogic Equation Editor
387
Flexlogic Timers
387
Flexelements
387
Non-Volatile Latches
391
Grouped Elements
392
Overview
392
Setting Group 1
392
Phase Current
393
Neutral Current
408
Ground Current
420
Negative Sequence Current
423
Breaker Failure (ANSI 50BF)
428
Voltage Elements
438
Control Elements
455
Overview
455
Trip Bus 1
456
Setting Groups
457
Selector Switch
458
Time of Day Timers
465
Capacitor Control
467
Automatic Voltage Regulator
471
Digital Elements
475
Digital Counters
478
Monitoring Elements
480
Inputs/Outputs
496
Contact Inputs
496
Virtual Inputs
498
Contact Outputs
499
Virtual Outputs
502
Resetting
502
Direct Inputs and Outputs
503
Teleprotection
507
Transducer Inputs/Outputs
509
Dcma Inputs
509
RTD Inputs
510
Dcma Outputs
511
Testing
515
Test Mode Function
515
Test Mode Forcing
515
Force Contact Inputs
516
Force Contact Outputs
516
GE C70 Instruction Manual (672 pages)
Capacitor Bank Protection and Control System
Brand:
GE
| Category:
Protection Device
| Size: 13.24 MB
Table of Contents
Table of Contents
3
1 Getting Started
11
Important Procedures
11
Cautions and Warnings
11
Inspection Procedure
12
Ur Overview
13
Introduction to the Ur
13
Hardware Architecture
13
Software Architecture
15
Important Concepts
15
Enervista Ur Setup Software
16
Pc Requirements
16
Installation
16
Configuring the C70 for Software Access
17
Using the Quick Connect Feature
20
Connecting to the C70 Relay
25
Setting up Cybersentry and Changing Default Password
26
Ur Hardware
28
Mounting and Wiring
28
Communications
28
Faceplate Display
28
Using the Relay
29
Faceplate Keypad
29
Menu Navigation
29
Menu Hierarchy
29
Relay Activation
30
Relay Passwords
30
Flexlogic Customization
30
Commissioning
31
2 Product Description
33
Introduction
33
Overview
33
Security
35
Ordering
39
Replacement Modules
44
Specifications
46
Protection Elements
46
User-Programmable Elements
49
Monitoring
50
Metering
50
Inputs
51
Power Supply
52
Outputs
52
Communications
54
Inter-Relay Communications
54
Environmental
55
Type Tests
56
Production Tests
56
Approvals
57
Maintenance
57
3 Hardware
59
Description
59
Panel Cutout
59
Rear Terminal Layout
65
Wiring
66
Typical Wiring
66
Dielectric Strength
67
Control Power
67
Ct/Vt Modules
68
Process Bus Modules
70
Contact Inputs and Outputs
70
Transducer Inputs/Outputs
78
Rs232 Faceplate Port
79
Cpu Communication Ports
79
Irig-B
82
Direct Input/Output Communications
83
Description
83
Fiber: Led and Eled Transmitters
85
Interface
86
Rs422 Interface
89
Ieee C37.94 Interface
91
4 Human Interfaces
95
Enervista Ur Setup Interface
95
Introduction
95
Creating a Site List
95
Enervista Ur Setup Overview
95
Enervista Ur Setup Main Window
97
Extended Enervista Ur Setup Features
98
Settings Templates
98
Securing and Locking Flexlogic Equations
102
Settings File Traceability
104
Faceplate Interface
107
Faceplate
107
Led Indicators
108
Custom Labeling of Leds
111
Display
116
Keypad
117
Breaker Control
117
Menus
118
Changing Settings
120
5 Settings
121
Overview
125
Settings Menu
125
Introduction to Elements
128
Introduction to Ac Sources
129
Product Setup
132
Security
132
Display Properties
147
Clear Relay Records
149
Communications
150
Modbus User Map
181
Real Time Clock
181
User-Programmable Fault Reports
186
Oscillography
187
Data Logger
189
User-Programmable Leds
191
User-Programmable Self Tests
194
Control Pushbuttons
195
User-Programmable Pushbuttons
196
Flex State Parameters
201
User-Definable Displays
202
Direct Inputs and Outputs
204
Installation
212
Remote Resources Configuration
213
System Setup
214
Ac Inputs
214
Power System
215
Signal Sources
217
C70 Capacitor Bank Protection and Control System GE Multilin
217
Breakers
220
Disconnect Switches
224
Flexcurves
227
Flexlogic
234
Introduction to Flexlogic
234
Flexlogic Rules
245
Flexlogic Evaluation
245
Flexlogic Example
246
Flexlogic Equation Editor
250
Flexlogic Timers
250
Flexelements
251
Non-Volatile Latches
255
Grouped Elements
256
Overview
256
Setting Group
256
Breaker Failure
256
Phase Current
266
Neutral Current
281
Ground Current
293
Negative Sequence Current
295
Voltage Elements
300
Control Elements
319
Overview
319
Trip Bus 1
319
Setting Groups
321
Selector Switch
323
Time of Day Timers
329
Capacitor Control
330
Automatic Voltage Regulator
335
Digital Elements
340
Digital Counters
343
Monitoring Elements
345
Inputs and Outputs
357
Contact Inputs
357
Virtual Inputs
359
Contact Outputs
360
Virtual Outputs
362
Remote Devices
363
Remote Inputs
364
Remote Double-Point Status Inputs
365
Remote Outputs
365
Resetting
366
Direct Inputs and Outputs
367
Iec 61850 Goose Analogs
370
Iec 61850 Goose Integers
371
Transducer Inputs and Outputs
372
Dcma Inputs
372
Rtd Inputs
373
Dcma Outputs
375
Testing
378
Test Mode
378
Force Contact Inputs
379
Force Contact Outputs
380
Advertisement
GE C70 Instruction Manual (624 pages)
Capacitor Bank Protection and Control System
Brand:
GE
| Category:
Protection Device
| Size: 22.63 MB
Table of Contents
Table of Contents
3
1 Introduction
11
Safety Symbols and Definitions
11
General Cautions and Warnings
11
For Further Assistance
12
2 Product Description
15
Description
16
Security
17
Order Codes
21
Order Codes with Enhanced CT/VT Modules
22
Order Codes with Process Bus Modules
24
Replacement Modules
26
Signal Processing
28
UR Signal Processing
28
Specifications
30
Protection Elements
31
User-Programmable Elements
36
Monitoring
37
Metering
38
Inputs
39
Power Supply
40
Outputs
41
Communications
43
Inter-Relay Communications
44
Cybersentry Security
45
Environmental
45
Type Tests
46
Production Tests
46
Approvals
47
Maintenance
47
3 Installation
49
Unpack and Inspect
49
Panel Cutouts
50
Horizontal Units
50
Vertical Units
51
Rear Terminal Layout
56
Wiring
58
Typical Wiring
58
Dielectric Strength
59
Control Power
59
CT/VT Modules
60
Process Bus Modules
62
Contact Inputs and Outputs
63
Transducer Inputs and Outputs
74
RS232 Faceplate Port
75
CPU Communication Ports
76
Irig-B
78
Direct Input and Output Communications
79
Description
79
Fiber: LED and ELED Transmitters
82
Interface
82
RS422 Interface
86
IEEE C37.94 Interface
88
Activate Relay
91
Install Software
92
Enervista Communication Overview
92
System Requirements
93
Install Software
94
Add Device to Software
95
Set IP Address in UR
95
Configure Serial Connection
101
Configure Ethernet Connection
102
Configure Modem Connection
104
Automatic Discovery of UR Devices
104
Connect to the C70
105
Connect to the C70 in Enervista
105
Use Quick Connect Via the Front Panel RS232 Port
106
Set up Cybersentry and Change Default Password
107
Import Settings
108
4 Interfaces
111
Enervista Software Interface
111
Introduction
111
Settings Files
111
Event Viewing
112
File Support
113
Enervista Main Window
113
Protection Summary Window
114
Settings Templates
115
Secure and Lock Flexlogic Equations
119
Settings File Traceability
122
Front Panel Interface
125
Front Panel Display
125
Front Panel Keypad
126
Menu Navigation
126
Menu Hierarchy
126
Changing Settings
127
Faceplate
129
LED Indicators
130
Custom LED Labeling
133
Breaker Control
138
Change Passwords
139
Invalid Password Entry
140
Logic Diagrams
140
Flexlogic Design and Monitoring Using Engineer
142
Design Logic
144
Send File to and from Device
154
Monitor Logic
155
View Front Panel and Print Labels
156
Generate Connectivity Report
157
Preferences
157
Toolbars
161
5 Settings
167
Settings Menu
167
Overview
170
Introduction to Elements
170
Introduction to AC Sources
171
Product Setup
173
Security
173
Display Properties
191
Clear Relay Records
193
Communications
194
Modbus User Map
258
Real-Time Clock
259
User-Programmable Fault Report
263
Oscillography
264
Data Logger
266
User-Programmable Leds
268
User-Programmable Self Tests
271
Control Pushbuttons
271
User-Programmable Pushbuttons
273
Flex State Parameters
277
User-Definable Displays
278
Direct Inputs and Outputs
280
Teleprotection
286
Installation
287
Remote Resources
287
Remote Resources Configuration
287
System Setup
289
AC Inputs
289
Power System
290
Signal Sources
291
Breakers
293
Disconnect Switches
298
Flexcurves
301
Flexlogic
308
Flexlogic Operands
308
Flexlogic Rules
321
Flexlogic Evaluation
321
Flexlogic Example
322
Flexlogic Equation Editor
327
Flexlogic Timers
327
Flexelements
327
Non-Volatile Latches
331
Grouped Elements
332
Overview
332
Setting Group 1
332
Phase Current
333
Neutral Current
348
Ground Current
360
Negative Sequence Current
363
Breaker Failure (ANSI 50BF)
369
Voltage Elements
378
Control Elements
395
Overview
395
Trip Bus
395
Setting Groups
397
Selector Switch
398
Time of Day Timers
405
Capacitor Control
407
Automatic Voltage Regulator
411
Digital Elements
415
Digital Counters
418
Monitoring Elements
420
Inputs/Outputs
436
Contact Inputs
436
Virtual Inputs
438
Contact Outputs
439
Virtual Outputs
442
Resetting
442
Direct Inputs and Outputs
443
Teleprotection
446
Transducer Inputs/Outputs
448
Dcma Inputs
448
RTD Inputs
449
Dcma Outputs
450
Testing
454
Test Mode Function
454
Test Mode Forcing
454
Force Contact Inputs
455
Force Contact Outputs
455
GE C70 Instruction Manual (546 pages)
Capacitor Bank Protection and Control System
Brand:
GE
| Category:
Control Systems
| Size: 10.42 MB
Table of Contents
Table of Contents
3
1 Introduction
9
Safety Symbols and Definitions
9
General Cautions and Warnings
9
For Further Assistance
10
2 Product Description
11
Security
13
Order Codes
17
Order Codes with Enhanced CT/VT Modules
18
Order Codes with Process Bus Modules
20
Replacement Modules
22
Signal Processing
25
UR Signal Processing
25
Specifications
27
Protection Elements
27
User-Programmable Elements
32
Monitoring
33
Metering
34
Inputs
35
Power Supply
36
Outputs
37
Communications
39
Inter-Relay Communications
40
Environmental
41
Type Tests
42
Production Tests
42
Approvals
43
Maintenance
43
3 Installation
45
Unpack and Inspect
45
Panel Cutouts
46
Horizontal Units
46
Vertical Units
47
Rear Terminal Layout
52
Wiring
53
Typical Wiring
53
Dielectric Strength
54
Control Power
54
CT/VT Modules
55
Process Bus Modules
57
Contact Inputs and Outputs
57
Transducer Inputs and Outputs
64
RS232 Faceplate Port
66
CPU Communication Ports
66
Irig-B
68
Direct Input and Output Communications
69
Description
69
Fiber: LED and ELED Transmitters
71
Interface
71
RS422 Interface
75
IEEE C37.94 Interface
77
Activate Relay
80
Install Software
81
Enervista Communication Overview
81
System Requirements
82
Install Software
82
Configure the C70 for Software Access
83
Configure Serial Communication
84
Configure Ethernet Communication
85
Automatic Discovery of UR Devices
86
Connect to the C70
86
Connect to the C70 in Enervista
86
Use Quick Connect Via the Front Panel RS232 Port
87
Use Quick Connect Via a Rear Ethernet Port
88
Set up Cybersentry and Change Default Password
93
4 Interfaces
95
Enervista Software Interface
95
Introduction
95
Settings Files
95
Event Viewing
96
File Support
96
Enervista Main Window
96
Settings Templates
97
Secure and Lock Flexlogic Equations
102
Settings File Traceability
104
Front Panel Interface
106
Front Panel Display
106
Front Panel Keypad
106
Menu Navigation
107
Menu Hierarchy
107
Changing Settings
108
Faceplate
109
LED Indicators
111
Custom LED Labeling
114
Breaker Control
119
Change Passwords
120
Invalid Password Entry
121
Logic Diagrams
122
5 Settings
125
Settings Menu
125
Overview
128
Introduction to Elements
128
Introduction to AC Sources
129
Product Setup
131
Security
131
Display Properties
149
Clear Relay Records
151
Communications
151
Modbus User Map
206
Real-Time Clock
206
User-Programmable Fault Report
210
Oscillography
211
Data Logger
213
User-Programmable Leds
214
User-Programmable Self Tests
218
Control Pushbuttons
218
User-Programmable Pushbuttons
220
Flex State Parameters
225
User-Definable Displays
226
Direct Inputs and Outputs
228
Installation
235
Remote Resources
235
Remote Resources Configuration
235
System Setup
236
AC Inputs
236
Power System
238
Signal Sources
238
Breakers
241
Disconnect Switches
246
Flexcurves
249
Flexlogic
256
Flexlogic Operands
256
Flexlogic Rules
269
Flexlogic Evaluation
269
Flexlogic Example
270
Flexlogic Equation Editor
275
Flexlogic Timers
275
Flexelements
275
Non-Volatile Latches
279
Overview
280
Setting Group 1
280
Grouped Elements
280
Phase Current
281
Neutral Current
295
Ground Current
307
Negative Sequence Current
309
Breaker Failure (ANSI 50BF)
315
Voltage Elements
324
Overview
341
Control Elements
341
Trip Bus
342
Setting Groups
343
Selector Switch
344
Time of Day Timers
352
Capacitor Control
352
Automatic Voltage Regulator
357
Digital Elements
361
Digital Counters
364
Monitoring Elements
366
Inputs/Outputs
378
Contact Inputs
378
Virtual Inputs
380
Contact Outputs
381
Virtual Outputs
384
Resetting
384
Direct Inputs and Outputs
385
Transducer Inputs/Outputs
389
Dcma Inputs
389
RTD Inputs
390
Dcma Outputs
391
Testing
394
Test Mode Function
394
Test Mode Forcing
395
Force Contact Inputs
396
Force Contact Outputs
396
GE C70 Communications Manual (532 pages)
Universal Relay Family
Brand:
GE
| Category:
Relays
| Size: 3.79 MB
Table of Contents
Table of Contents
3
1 Introduction
7
Products
7
Features Per Product
7
Communication Ports
20
Safety Symbols and Definitions
20
For Further Assistance
20
Modbus
21
2 Modbus Communication
21
Modbus RTU Protocol
21
Introduction
21
Configuration
21
Physical Layer
21
Data Link Layer
22
Modbus RTU CRC-16 Algorithm
23
Modbus Function Codes
24
Supported Function Codes
24
Read Actual Values or Settings (Function Code 03/04H)
24
Execute Operation (Function Code 05H)
25
Store Single Setting (Function Code 06H)
25
Store Multiple Settings (Function Code 10H)
26
Exception Responses
26
File Transfers
27
Obtaining Relay Files Using Modbus
27
Memory Map
32
Modbus Memory Map
32
6 Iec 60870-5-104
80
Communication
81
Data Formats
204
3 Iec 61850 Communication
239
Overview
239
Introduction
239
Abstract Communication Service Interface (ASCI)
241
Datasets
244
Txgoose
245
Rxgoose
247
Reports
248
Commands
250
Substation Configuration Language (SCL)
250
Configuring the UR Using SCL
256
Merge SCL File
261
Configurable Logical Devices
262
Protocol Implementation Conformance Statement (PICS)
262
Basic Conformance Statement
262
ACSI Conformance Statement
263
ACSI Basic Conformance Statement
263
ACSI Models Conformance Statement
263
ACSI Services Conformance Statement
265
Model Implementation Conformance Statement (MICS)
267
Master (Root) Logical Device
268
Protection (Prot) Logical Device
275
Control (Ctrl) Logical Device
354
System Logical Device
389
Meter Logical Device
410
General (Gen) Logical Device
431
GE Namespace
447
Enumerations
462
SCL Implementation Conformance Statement (SICS)
463
PIXIT Conformance Statement
465
TICS Conformance Statement
470
SCL Logging
472
Overview of Process
472
SCL File Storage on UR
473
Generation of CID Files
473
Schema Version Used by Ur/Enervista
473
CID File Processing Steps
473
SCL Log File Format and Examples
473
Troubleshooting Log File Errors
475
G2 Implementation Model for GOOSE Configuration Via SCL
475
Introduction
475
Configuration Process
476
Configuration Process with IED Setup Tool
478
IED Capability Description (ICD) File
478
Instantiated IED Capability Description (IID) File
482
Configured IED Description (CID) File
482
Sample SCL Files
484
Annex - Optional Intermediate GOOSE Reception Objects
489
E3-2.0 Implementation Model for GOOSE Configuration Via SCL
492
Introduction
492
Workflow
492
ICD Files
493
CID Files
494
IID Files
495
GE C70 Communications Manual (526 pages)
UR Family
Brand:
GE
| Category:
Controller
| Size: 3.78 MB
Table of Contents
Table of Contents
3
1 Introduction
7
Products
7
Features Per Product
7
Communication Ports
20
Safety Symbols and Definitions
20
For Further Assistance
20
Modbus
21
2 Modbus Communication
21
Modbus RTU Protocol
21
Introduction
21
Configuration
21
Physical Layer
21
Data Link Layer
22
Modbus RTU CRC-16 Algorithm
23
Modbus Function Codes
24
Supported Function Codes
24
Read Actual Values or Settings (Function Code 03/04H)
24
Execute Operation (Function Code 05H)
25
Store Single Setting (Function Code 06H)
25
Store Multiple Settings (Function Code 10H)
26
Exception Responses
26
File Transfers
27
Obtaining Relay Files Using Modbus
27
Memory Map
32
Modbus Memory Map
32
6 Iec 60870-5-104
80
Communication
81
Data Formats
203
3 Iec 61850 Communication
239
Overview
239
Introduction
239
Abstract Communication Service Interface (ASCI)
241
Datasets
244
Txgoose
245
Rxgoose
247
Reports
248
Commands
250
Substation Configuration Language (SCL)
250
Configuring the UR Using SCL
256
Merge SCL File
261
Configurable Logical Devices
262
Protocol Implementation Conformance Statement (PICS)
262
Basic Conformance Statement
262
ACSI Conformance Statement
263
ACSI Basic Conformance Statement
263
ACSI Models Conformance Statement
263
ACSI Services Conformance Statement
265
Model Implementation Conformance Statement (MICS)
267
Master (Root) Logical Device
268
Protection (Prot) Logical Device
275
Control (Ctrl) Logical Device
351
System Logical Device
385
Meter Logical Device
406
General (Gen) Logical Device
426
GE Namespace
442
Enumerations
457
SCL Implementation Conformance Statement (SICS)
458
PIXIT Conformance Statement
460
TICS Conformance Statement
465
SCL Logging
467
Overview of Process
467
SCL File Storage on UR
468
Generation of CID Files
468
Schema Version Used by Ur/Enervista
468
CID File Processing Steps
468
SCL Log File Format and Examples
468
Troubleshooting Log File Errors
470
G2 Implementation Model for GOOSE Configuration Via SCL
470
Introduction
470
Configuration Process
471
Configuration Process with IED Setup Tool
473
IED Capability Description (ICD) File
473
Instantiated IED Capability Description (IID) File
477
Configured IED Description (CID) File
477
Sample SCL Files
479
Annex - Optional Intermediate GOOSE Reception Objects
484
E3-2.0 Implementation Model for GOOSE Configuration Via SCL
487
Introduction
487
Workflow
487
ICD Files
488
CID Files
489
IID Files
490
Advertisement
Related Products
GE Cafe CFCP1NIYSS
GE C1033
GE Appliances CG5985
GE CyberDome II
GE Profile Advantium CB1001
GE CB8
GE CA15DR
GE CustomStyle Profile Performance 22
GE C30
GE CTX16AM
GE Categories
Refrigerator
Ranges
Microwave Oven
Air Conditioner
Dishwasher
More GE Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL