Advertisement

Consumer Protection Act 1987
As responsible manufacturers, we take care to make sure that our
products are designed and constructed to meet the required safety
standards when properly installed and used.
IMPORTANT NOTICE: PLEASE READ THE ACCOMPANYING
WARRANTY: Any alteration that is not approved by Aga, could
invalidate the approval of the appliance, operation of the warranty
and could also affect your statutory rights. Use only authorised
replacement parts.
All local regulations including those referring to national and
European standards need to be complied with when installing
the appliance.
Control of Substances - Health and Safety
Important
This appliance may contain some of the materials that are indicated.
It is the Users/Installers responsibility to ensure that the necessary

INTRODUCTION

The Rayburn 345W has been designed to burn a variety
of wood logs and thereby provide heating facilities for
cooking, domestic hot water and central heating.
The thermostatically controlled hot water boiler can be
operated independently of the cooker and will provide hot
water for central heating and domestic use (normal
setting for winter usage), whilst manually operated
spinwheel control on the front of the ashpit door will
provide heat for cooking and domestic hot water (normal
setting for summer usage).
The cooker/boiler flueway damper knob on the centre
front of the cooker below the top plate requires to be set
in conjunction with the flue chamber damper to obtain the
appropriate service required from the appliance.

PREPARING COOKER FOR USE

FIREBRICK POSITIONS

The Rayburn 345W is delivered complete including a set
of boiler removable firebricks where positional location
determines the amount of hot water supplied in winter
and summer seasons.
The oven side and firebox front firebricks are
permanently fixed with fire cement and should remain in
their positions at all times.
The two boiler face side bricks and boiler face rear brick
are so located for summer use when hot water, for
domestic use only, will be provided.
For winter use or central heating facilities the boiler face
rear brick is removed and the two boiler face side bricks
are transferred to locate on/over the oven side bricks.
Secondary Air Slide.
On opening the firedoor the secondary air slide is seen
on the base of the opening and should be set according
raywarranty@aga-web.co.uk
Users Instructions.
Rayburn Heatranger 345W
Wood Burning Cooker
personal protective clothing is worn when handling, where
applicable, the pertinent parts that contain any of the listed materials
that could be interpreted as being injurious to health and safety, see
below for information.
Firebricks, Fuel beds, Fuels - when handling use disposable
gloves.
Fire Cement - when handling use disposable gloves.
Glues and Sealants - exercise caution - if these are still in liquid
form use face mask and disposable gloves.
Glass Yarn, Mineral Wool, Insulation Pads, Ceramic Fibre,
Kerosene Oil - may be harmful if inhaled, may be irritating to skin,
eyes, nose and throat. When handling avoid inhaling and contact
with skin or eyes. Use disposable gloves, face-masks and eye
protection. After handling wash hands and other exposed parts.
When disposing of the product, reduce dust with water spray,
ensure that parts are securely wrapped.
THE ASHPIT AND FIREBOX DOORS MUST BE LOCKED
CLOSED AT ALL TIMES DURING NORMAL USE, EXCEPT
WHEN LIGHTING OR RE-FUELLING.
to the heating requirement. (See Fig. 6).
Air Slide Open - heating
Air Slide Closed - cooking
WARNING: HOT SURFACES, use the tool supplied to
operate this appliance. It is recommended to use the
heatproof glove supplied when raising the dome lids to
use the hotplate. Replacement gloves can be obtained
from the Aga Shop.
Fig. 1
1
WARNING
10/07 EOPI 515158

Advertisement

Table of Contents
loading

Summary of Contents for Rayburn Heatranger 345W

  • Page 1 THE ASHPIT AND FIREBOX DOORS MUST BE LOCKED CLOSED AT ALL TIMES DURING NORMAL USE, EXCEPT WHEN LIGHTING OR RE-FUELLING. The Rayburn 345W has been designed to burn a variety of wood logs and thereby provide heating facilities for to the heating requirement. (See Fig. 6).
  • Page 2 RECOMMENDED FUELS Fuel should be stored under cover and ventilated, and kept dry. Wet kitchen refuse should not be burned. The appliance has been tested using wood logs only. It is not suitable to burn solid mineral fuels. CHIMNEY FIRES Prevention: Chimney fires do not occur in clean, intact, properly installed chimneys.
  • Page 3 FUELLING WITH WOOD OR PEAT LIGHTING THE FIRE All Fuels using Wood and Paper The cooker will satisfactorily burn wood logs, blocks or a) Check the flue pipe is free of blockage. peat briquettes, but logs should be perfectly dry in order b) Open firebox door.
  • Page 4 obtained by the setting of the cooker/boiler damper. Set the cooker/boiler damper knob on the front of the cooker to ‘C’ and the boiler thermostat knob on the rear left hand corner of the top plate, to its minimum setting. d) Thermostat set at No.1 as domestic hot water is obtained when cooking.
  • Page 5 increasing the opening setting of the flue chamber BOILER CENTRAL HEATING door, using the flue dilution lever. THERMOSTAT SETTING 2. If the fuel does not burn but ‘dies out’, the draught should be increased by reducing the opening setting of the flue chamber door, using the flue dilution lever. Set the cooker/boiler damper knob ‘H’.
  • Page 6 required, close the spinwheel to approximately one turn DE-ASHING open. Thereafter control the temperature of the oven by adjusting the spinwheel. ALWAYS DE-ASH BEFORE RE-FUELLING. NOTE: THE METHOD SHOULD PROVE SUCCESSFUL IN ALMOST ALL CASES, BUT IF CLOSING THE FLUE Open the ashpit door to give access to the ashpan (See CHAMBER DAMPER CAUSES THE FIRE TO SMOKE, Fig.
  • Page 7 the fire box. (See Fig. 14). Clean boiler flue outlet by inserting brush horizontal at right hand of boiler aperture below top plate, allowing debris to fall into firebox. Replace flue chamber door and hotplate plug and riddle the bottomgrate thoroughly to clear the bottomgrate ready for re-lighting.
  • Page 8 FIREBRICK REPLACEMENT SPARES LIST The firebricks fitted to the Rayburn 345W are of first Part Number Description No Reqd quality manufacture, and providing the cooker has been Boiler Thermostat installed and used correctly will have a reasonable life. 1/16182 T...
  • Page 12 For further advice or information contact your local distributor/stockist With Aga’s policy of continuous product improvement, the Company reserves the right to change specifications and make modifications to the appliance described at any time. Manufactured by Station Road Ketley Telford Shropshire TF1 5AQ England www.aga-web.co.uk...

Table of Contents