You have purchased the XG series, a compact, layer 2 switch that achieves unsurpassed standards of high throughput and low-latency performance. This guide describes the XG series (XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600) functions, installation procedures, configuration operations, and maintenance procedures and should be read and understood before you start using your XG series.
XG Series User’s Guide Contents Contents Preface ................................2 Organization and Usage of This Manual ......................16 Target Readers and Required Knowledge ....................... 16 Areas Covered ................................16 Trademark Notification in This Manual ........................17 How the Manuals for This Device Are Organized ....................18 End User's License Agreement .........................19 Chapter 1 Features and Functions.................
Page 4
XG Series User’s Guide Contents Chapter 4 Switch Functions and their Configuration........... 59 Basic Switch Functions ..........................61 4.1.1 Switching Mode (XG2600) ........................61 4.1.2 MAC Address Table Management ......................62 4.1.3 Jumbo Frame Support ..........................63 4.1.4 Flow Control ............................63 4.1.5 Storm Control ............................
Page 7
XG Series User’s Guide Contents 5.5.6 Management LAN port IPv6 Related Information ................216 5.5.6.1 oob ip6 use ..........................216 5.5.6.2 oob ip6 ifid ..........................216 5.5.6.3 oob ip6 address ........................217 5.5.6.4 oob ip6 ra mode ........................217 5.5.6.5 oob ip6 route ..........................
Page 8
XG Series User’s Guide Contents 5.13 AAA Information Settings ........................247 5.13.1 Group ID Information ..........................248 5.13.1.1 aaa name ..........................248 5.13.2 AAA User Information .......................... 249 5.13.2.1 aaa user id ..........................249 5.13.2.2 aaa user password ........................250 5.13.2.3 aaa user user-role ........................251 5.13.3 RADIUS Information Settings .......................
Page 9
XG Series User’s Guide Contents 5.15.2 System Log Information ........................285 5.15.2.1 syslog server address ......................285 5.15.2.2 syslog server pri ........................286 5.15.2.3 syslog pri ..........................287 5.15.2.4 syslog facility ......................... 287 5.15.2.5 syslog security ........................288 5.15.2.6 syslog dupcut .......................... 288 5.15.2.7 syslog command-logging .......................
Page 11
XG Series User’s Guide Contents 5.17.4 Command Alias ............................355 5.17.4.1 alias ............................355 5.17.4.2 show alias ..........................356 5.17.4.3 clear alias ..........................356 5.17.5 Command Output ........................... 357 5.17.5.1 more ............................357 5.17.5.2 tail ............................358 5.18 System Operations and Display Commands ..................359 5.18.1 System Operations and Display Commands ..................
Page 12
XG Series User’s Guide Contents 5.21 USB connection Counter, Log, Statistics, and Status Display and Clear Operation Commands ..431 5.21.1 USB connection Counter, Log, and Statistics Clear Commands ............431 5.21.1.1 show usb hcd status ........................ 431 5.21.1.2 show usb storage status ......................432 5.22 LACP Counter, Log, Statistics, and Status Display and Clear Operation Commands ......435 5.22.1 LACP Counter, Log, Statistics, and Status Display Commands ............
Page 13
XG Series User’s Guide Contents 5.29 LLDP Counter, Log, Statistics, and Status Display and Clear Operation Commands ......496 5.29.1 LLDP Counter, Log, Statistics, and Status Display Commands ............496 5.29.1.1 show lldp ..........................496 5.29.1.2 show lldp summary ........................ 502 5.29.1.3 show lldp neighbors .......................
Page 14
XG Series User’s Guide Contents 5.39 Ethernet L3 Monitor Function Counter, Log, Statistics, and Status Display and Clear Operation Commands ............................537 5.39.1 Ethernet L3 Monitor Function Counter, Log, Statistics, and Status Display Commands ..... 537 5.39.1.1 show icmpwatch ........................537 5.39.1.2 show icmpwatch statistics ......................
Page 15
Group ........................ 611 B.1.12 qBridgeMIB Group ........................ 613 B.1.13 ifMIB Group .......................... 614 B.1.14 radiusMIB Group ........................615 Fujitsu Extension MIB ............................616 B.2.1 nonosSystem Group ....................... 616 B.2.2 nonosSystemError Group ....................... 616 B.2.3 nonosLineset Group ....................... 616 B.2.4 nosDualPower Group ......................
XG Series User's Guide Organization and Usage of This Manual This section describes target readers, contents, notations, etc. of this guide. Target Readers and Required Knowledge This guide was written for administrators, who are in charge of network construction, maintenance, and management. To use this guide, the following knowledge is required.
XG Series User's Guide Trademark Notification in This Manual Microsoft, MS-DOS, Windows, Windows NT, Windows Server and Windows Vista are registered trademarks of the Microsoft Corporation in the USA and other countries. Adobe and Reader are trademarks or registered trademarks of Adobe Systems Incorporated in the USA and other coun- tries.
XG Series User's Guide How the Manuals for This Device Are Organized The following are XG series related manuals. Use these manuals as necessary. Manual Name Description Safety and Installation Guide This manual describes the safety and installation. Hardware Guide Describes the hardware of the XG.
XG Series User's Guide End User's License Agreement @(#)COPYRIGHT 8.2 (Berkeley) 3/21/94 All of the documentation and software included in the 4.4BSD and 4.4BSD-Lite Releases is copyrighted by The Regents of the University of California. Copyright 1979, 1980, 1983, 1986, 1988, 1989, 1991, 1992, 1993, 1994 The Regents of the University of California. All rights reserved.
Page 21
XG Series User's Guide 3. All advertising materials mentioning features or use of this software must display the following acknowledgement:"This product includes cryptographic software written by Eric Young (eay@cryptsoft.com)" The word 'cryptographic' can be left out if the rouines from the library being used are not cryptographic related:-). 4.
Chapter 1 Features and Functions This chapter describes the features and functions of the device. Hardware Specifications ............23 1.1.1 Switch Specifications .
Hardware Specifications This section explains the Hardware specifications for the device. 1.1.1 Switch Specifications : supported, –: Not supported item specification XG0440DC / model name XG0224 XG0448 XG2600 XG0440DCR Interface Console Port specifications RS232C number of ports Baud rate (bps)
Page 24
XG Series User's Guide Chapter 1 Features and Functions item specification XG0440DC / model name XG0224 XG0448 XG2600 XG0440DCR Expansion Slot 2 (*1) – – Power Voltage/Frequencys AC100V-240V (50/60Hz) Power code for 3-pin socket (grounded) (125V13A) AC:for 3-pin socket (grounded) (125V13A)
XG Series User's Guide Chapter 1 Features and Functions Applicable to XG0224 only. Cable length (maximum) is under the condition that the stressed receiver sensitivity satisfy the permissible level. CLASS 1 LASER PRODUCT SFP+ Module XG0448 / XG0440DC / XG0440DCR / XG2600 Available Model 10GBASE-SR / LR...
XG Series User's Guide Chapter 1 Features and Functions SFP+ Expansion Card XG0224 / XG0448 Available Model item specification Type name SJ10GSFPZ Interface (ETHER) specifications IEEE802.3ae (10GBASE-R Interface) number of ports Baud rate (bps) connector SFP connector CX4 Expansion Card XG0224 / XG0448 Available Model...
1.1.3 10/100/1000BASE-T Port Specifications All models Available Model connector is RJ45 8 pin • XG0224 / XG0448 / XG0440DC / XG0440DCR –: Not supported Signal name (XG0224: 1 to 24 port) (XG0448: 1 to 48 port) Pin numbering (XG0440DC / XG0440DCR: 1 to 40 port)
XG Series User's Guide Chapter 1 Features and Functions 1.1.4 USB Port Specifications XG0448 / XG0440DC / XG0440DCR / XG2600 Available Model Pin numbering Signal name VBUS 1.1.5 Console Port Specifications All models Available Model connector is RJ45 8 pin A straight cable is used. –: Not supported Pin numbering Signal name in / out Content...
Chapter 1 Features and Functions Software Specifications This section explains the software specifications for the device. 1.2.1 Software Specifications ❍ : Supported, –: Not supported Features Item XG0440DC / XG0224 XG0448 XG2600 XG0440DCR Forwarding Mode Store and Forward Selectable VLAN Port VLAN ❍...
Page 31
XG Series User's Guide Chapter 1 Features and Functions Features Item XG0440DC / XG0224 XG0448 XG2600 XG0440DCR Rewrite the priority ❍ ❍ ❍ (with the use of (with the use of (with the use of COS (user priority) – ACL)
XG Series User's Guide Chapter 1 Features and Functions 1.2.3 System Maximum Values –: Not supported Features Item XG0440DC / XG0224 XG0448 XG2600 XG0440DCR Bridge information # of blocks registered (*1) 16000 32000 16000 # of static blocks registered VLAN definition...
Page 35
XG Series User's Guide Chapter 1 Features and Functions Features Item XG0440DC / XG0224 XG0448 XG2600 XG0440DCR # of ARPs registered 8000 static – # of IPv4 interfaces 100 (*10) # of IPv6 interfaces 100 (*10) RA information (IPv6) # of interface receiving RA...
Page 36
*3) First, the maximum number of neighbor LLDP device information is 15 times of the number of total ports including 1G and 10G. (XG0224: 390, XG0448: 780, XG0440DC,XG0440DCR: 660, XG2600: 390) Second, each port including 1G and 10G must have at least one LLDP information. (XG0224: 26, XG0448: 52, XG2600: 26) The remaining number of neighbor LLDP device information can be distributed to any ports.
Chapter 2 Using the CLI This chapter describes how to use the command line interface (CLI) to operate the device. Overview of the CLI..............38 2.1.1 Operating Environment for the CLI .
XG Series User's Guide Chapter 2 Using the CLI Overview of the CLI This section describes how to use the command line interface (CLI) for the XG Series. 2.1.1 Operating Environment for the CLI There are two ways to access the device to run commands. •...
XG Series User's Guide Chapter 2 Using the CLI for the device as below. XG2600(config)# ether 1 vlan untag 1 XG2600(config)# lan 0 vlan 1 XG2600(config)# lan 0 ip 192.168.1.1/24 3 XG2600(config)# commit XG2600(config)# save A VT100, VT200, or xterm can be used as a terminal. 2.1.2 Command Modes and Mode Switching The following table shows a hierarchy of command modes and mode switching.
XG Series User's Guide Chapter 2 Using the CLI Login to the device When you connect to the device via a console port, telnet, or ssh connection (*1), a login prompt like the following one appears: Login: Enter user name (*1) Password: Enter password.
Page 41
XG Series User's Guide Chapter 2 Using the CLI Privilege classes (admin class and user class) Two privilege classes are available; admin class (login as admin) and user class (login as user). • admin class All commands can be run. However, admin commands and su commands cannot be run because it is not necessary to run them in admin class.
XG Series User's Guide Chapter 2 Using the CLI 2.1.2.2 Executable commands Command execution is restricted according to the following conditions: • Command type • Privilege class • Use mode " Privilege classes (admin class and user class)", p. Reference "...
XG Series User's Guide Chapter 2 Using the CLI Using the CLI 2.2.1 Using the Shell Function The shell function supports the following features in order to assist command entry: • Command execution function • Entry editing function • Command name autocomplete function •...
XG Series User's Guide Chapter 2 Using the CLI 2.2.1.3 Command name autocomplete function The command name autocomplete function allows you to display a list of command names without entering anything by pressing the TAB key or CTRL + I. In addition, if you press the TAB key or CTRL + I after entering part of a command, the command string will be automatically completed.
Page 45
XG Series User's Guide Chapter 2 Using the CLI Number of times the TAB Operation key or CTRL + I are hit Three times Command forms are displayed. In operation mode, simplified command forms are displayed. In configuration mode, when the configuration hierarchy function is disabled, simplified command forms are displayed.
XG Series User's Guide Chapter 2 Using the CLI 2.2.1.4 Command argument autocomplete function While entering configuration command arguments, the command argument autocomplete function allows you to display a list of arguments and candidate arguments without entering anything by pressing the TAB key or CTRL + I. In addition, if you press the TAB key or CTRL + I after entering part of an argument, the remaining character string will be automatically completed.
XG Series User's Guide Chapter 2 Using the CLI 2.2.1.7 Configuration hierarchy function The configuration hierarchy function interprets common portions of executed configuration command names and arguments as a hierarchy level, and allows you to move between hierarchy levels. When you execute a configuration command and the command completes successfully, in general the portion from the command name to the argument two arguments before an argument specifying a variable value becomes a hierarchy level.
XG Series User's Guide Chapter 2 Using the CLI • To disable the configuration hierarchy function: Press CTRL + G. The following message is displayed and the configuration hierarchy function is disabled. Information which has been partially entered will be discarded. <NOTICE>...
XG Series User's Guide Chapter 2 Using the CLI Re-executing commands You can enter a history specifier at the beginning of the command string to re-execute the command. The command will be executed after the command string for re-execution is displayed. In addition, command history and history numbers can be viewed with the history command.
XG Series User's Guide Chapter 2 Using the CLI Replacing the last command string By entering a replacement specifier (^), replacement target string, and replacement string at the beginning of a command string, you can re-execute the last command with the specified string replaced with a new string. If no replacement string is specified, the target string will be deleted.
XG Series User's Guide Chapter 2 Using the CLI Replacing command strings By entering a single-replacement specifier (:s) or all-replacement specifier (:gs) following a history specifier and replacement specifier, you can replace the target string and re-execute the command string. A single-replacement specifier replaces the first matching string only, while an all-replacement specifier replaces all matching strings.
XG Series User's Guide Chapter 2 Using the CLI 2.2.1.10 List of shell key bindings The following table shows the key bindings for using the shell. Key combination Single Operation (note) Ctrl+A Moves the cursor to the top. ← (Note) Ctrl+B Moves the cursor to the left by one character.
XG Series User's Guide Chapter 2 Using the CLI 2.2.2 Error Messages Common to All Commands The table below lists error messages common to all commands and displayed when autocompleting or executing commands. Note that the argument position shown in these error messages indicates the place of the erroneous argument, counted from the command name as "1."...
XG Series User's Guide Chapter 2 Using the CLI 2.2.3 Characters that can be entered • Any letter (A-Z, a-z) and digit (0-9) • Space (ASCII code: 0x20) • Symbols: !, #, $, %, `, ', (, ), _, -, ~, ^, \, {, }, :, +, ,, ., @, =, [, ], &, *, ;, /, ?, |, > Command and option separators are recognized as one or more space characters (ASCII code: 0x20).
Chapter 3 Installation This chapter describes the installation procedures for the device. Refer to "chapter 2 Using the CLI", p. 37, for details on using the CLI. Reference Refer to "chapter 5 Command Reference", p. 85, for details on commands. Workflow for Initial Setup of the Device .
XG Series User's Guide Chapter 3 Installation Workflow for Initial Setup of the Device This section describes the procedures to setup the device. 1) Prepare a terminal Prepare a terminal for the initial configuration. 2) "Besic Setting Up" Connect the device and terminal with an RS232C cable. The band rate setting is 9,600 bps. To configure the Device basically, carry out the following procedure.
XG Series User's Guide Chapter 3 Installation 3.1.1 Configure LAN Interface The initial setting of the LAN interface is for only IPv6 link-local address. To use the following functions, configure the LAN interface. • Telnet connection • SNMP manager connection •...
XG Series User's Guide Chapter 3 Installation 3.1.3 SNMP Configuration (Optional) To operate in conjunction with an SNMP manager, the SNMP agent must be configured. To configure the SNMP agent, carry out the following procedures in "admin" Operation mode. Command Task XG2600# configure Switch to Configuration mode.
Chapter 4 Switch Functions and their Configuration This chapter describes the functions of the device and how to configure them. Refer to "2.1.1 Operating Environment for the CLI", p. 38, for details on using the CLI. Reference Refer to "chapter 5 Command Reference", p. 85, for details on commands.
Page 60
IGMP Snooping ..............77 4.8.1 Registering Group Members .
4.1.1 Switching Mode (XG2600) XG2600 provides the following two switching modes. XG0224 / XG0448 / XG0440DC / XG0440DCR provide store-and-forward switching modes only. • Store-and-forward switching mode After the device finishes receiving a frame, it checks the FCS (Frame Check Sequence) and performs a validity check (on packet size, etc.) before forwarding the frame.
The MAC address table is a database used for managing the association between address information and destination ports. XG0224 and XG2600 can learn up to 16000 entries of MAC addresses. XG0448 / XG0440DC / XG0440DCR can learn up to 32000 entries of MAC addresses.
Chapter 4 Switch Functions and their Configuration 4.1.3 Jumbo Frame Support The device can transmit jumbo frames of up to 9KB (9216 bytes). (XG0224 / XG0448 / XG0440DC / XG0440DCR) The device can transmit jumbo frames of up to 16KB (16128 bytes). (XG2600) 4.1.4...
Task XG0224# configure Switch to Configuration mode. XG0224(config)# ether 10 type mirror 0 1 both Configure the port 10 to be destination port and the receive/send frames of the source port (port 1) are mirrored. XG0224(config)# ether 10 type mirror 10 2 tx Configure the port 10 to be destination port and the send frames of the source port (port 2) are mirrored.
XG Series User's Guide Chapter 4 Switch Functions and their Configuration Link Down Relay Link Down Relay is a function that monitors the status of a specified port link, if a link down detected the device notifies the device force to link down the relay port. (1)When Link Down Relay is not used Link Up Link Up...
XG Series User's Guide Chapter 4 Switch Functions and their Configuration Link Aggregation Link aggregation is a function that combines multiple ports into a single logical link. A set of ports that comprise a logical link are called an aggregation group. Link aggregation provides: •...
XG Series User's Guide Chapter 4 Switch Functions and their Configuration 4.4.1 Configuring Link Aggregation Either static or dynamic (also known as LACP) configuration can be selected for Link Aggregation. • Static configuration Configures aggregation groups statically. • LACP Configures link aggregation using Link Aggregation Control Protocol (LACP). The LACP is a switch-to-switch control protocol that enables dynamic configuration of aggregation groups and is standardized by the IEEE802.3ad.
XG Series User's Guide Chapter 4 Switch Functions and their Configuration 4.4.2 Frame Distribution Methods in Link Aggregation How frames are distributed across physical ports that make up an aggregation group are determined by the contents of a frame (source and destination MAC addresses). There are 6 ways to specify how frames are distributed: •...
XG Series User's Guide Chapter 4 Switch Functions and their Configuration 4.4.3 The Number of Ports That Require Linkup It is possible to specify the number of ports that enable a linkup state for an aggregation group. If the number of active ports that make up an aggregation group in a linkup state is less than the specified number of ports, the aggregation group changes to a linkdown state.
XG Series User's Guide Chapter 4 Switch Functions and their Configuration Spanning Tree Protocol (STP) The Spanning Tree Protocol (STP) is a function that prevents loops from occurring on a network. It is also possible to provide network redundancy by intentionally creating a loop. STP exclusively uses only one active path between network devices, and shuts out other paths, to avoid network loops.
XG Series User's Guide Chapter 4 Switch Functions and their Configuration 4.5.1 Port Roles Based on Spanning Tree RSTP assigns one of these port roles to individual ports: • Root port Provides the best path (lowest cost) when the switch forwards packets to the root switch. •...
XG Series User's Guide Chapter 4 Switch Functions and their Configuration 4.5.3 Configuring Spanning Tree To configure the spanning tree protocol, carry out the following procedure in "admin" Operation mode. Command Task XG2600# configure Switch to Configuration mode. XG2600(config)# stp mode stp Enable Spanning Tree Protocol.
XG Series User's Guide Chapter 4 Switch Functions and their Configuration VLAN VLAN (Virtual LAN) is a technology that divides a single network into virtually separated networks. VLANs are separate logical networks within one physical network. A VLAN capable switch can change and define new LAN network configurations without changing physical cable connections.
XG Series User's Guide Chapter 4 Switch Functions and their Configuration 4.6.2 Tag-Based (IEEE802.1Q) VLAN Tag-based VLAN is a method of configuring VLANs so that the frame forwarding decision is based on a tag in the MAC header identifying the VLAN membership. 4 bytes of additional data in the header, called a VLAN tag, identifies the VLAN frame ownership.
XG2600(config)# save Save the configuration. XG2600(config)# reset Reset the device. • XG0224 / XG0448 / XG0440DC / XG0440DCR Command Task XG0224# configure Switch to Configuration mode. XG0224(config)# ether 1-8 qos priority (0-7) Set a default priority for frames whose priority was not set (VLANuntagged frame) when received.
If "igmpsnoop unknown flooding off" command is set (the default setting), any Multicast frames except IPv4 Multicast packets Note are never will not flooding all ports belonging to the same VLAN. When you using IPv6 or another protocol, please set use the "igmpsnoop unknown flooding on" command (XG0224 / XG0448 / XG0440DC / XG0440DCR). IGMP Snooping...
• If "igmpsnoop unknown flooding off" command is set (the default setting), IPv4 Multicast packets that cannot be registered are those will not flooding all ports belonging to the same VLAN (XG0224 / XG0448 / XG0440DC / XG0440DCR). The following figure shows the relationship between the registered IP multicast address and the multicast MAC address.
XG Series User's Guide Chapter 4 Switch Functions and their Configuration 4.8.2 Removing Group Members The group members registered by IGMP snooping are removed under the following status. • If after receiving an IGMP Report message for group registration, the group member interval expires before the device receives another IGMP Report message, the switch removes the host from the group member.
XG Series User's Guide Chapter 4 Switch Functions and their Configuration 4.8.3 Managing Group Members When network congestion causes Leave message loss or there is a host that uses IGMPv1, the multicast router does not receive Leave messages. The multicast router sends out an IGMP General Query message to all hosts (IP address: 224.0.0.1) at intervals (query interval) to determine membership information.
XG Series User's Guide Chapter 4 Switch Functions and their Configuration 4.8.4 IGMP Querier In a typical network configuration, the multicast router periodically sends out an IGMP General Query message to determine if any of the hosts on the network are members of any multicast groups. Receiving a response from a host ascertains its membership in a multicast group.
XG Series User's Guide Chapter 4 Switch Functions and their Configuration 4.8.5 Configuring IGMP Snooping To configure IGMP snooping, carry out the following procedure in "admin" Operation mode. Command Task XG2600# configure Switch to Configuration mode. XG2600(config)# igmpsnoop use on Enable global IGMP snooping on the device.
XG Series User's Guide Chapter 4 Switch Functions and their Configuration Network Management 4.9.1 Traffic Statistics The device can display traffic statistics to analyze network operations such as traffic bytes, errors, etc. The following are the Traffic Statistics the device provides. •...
XG Series User's Guide Chapter 4 Switch Functions and their Configuration Command Task XG2600(config)# snmp user 0 read view 0 Set MIB read permission view for SNMP v3. XG2600(config)# snmp user 0 notify view 0 Set trap notification permission view for SNMP v3. XG2600(config)# commit Apply the configuration.
Chapter 5 Command Reference This chapter explains about Command Reference. Port Information Settings ............89 5.1.1 Ethernet Common Information .
Page 86
5.5.7 Management LAN port LLMNR Related Information ......219 IPv4 Related Information ............220 5.6.1 IPv4 Related Information .
Page 87
5.20.1 Ethernet Counter, Log, Statistics, and Status Display Commands ....390 5.20.2 Ethernet Counter, Log, and Statistics Clear Commands ......430 5.21 USB connection Counter, Log, Statistics, and Status Display and Clear Operation Commands .
A range of multiple ports can be specified in <number> ("ether" port definition number) shown in the [Options] of each command in this section. • Examples of multiple ports range specification for XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600. = port1 1-20...
XG Series User's Guide Chapter 5 Command Reference 5.1.1 Ethernet Common Information This section explains about the commands related to ethernet common information. 5.1.1.1 forwardingmode Function forwardingmode <mode> Available Model XG2600 Syntax forwardingmode <mode> Options <mode> • store-and-forward store and forward mode is used •...
Chapter 5 Command Reference 5.1.1.2 ether use Function Set the port use. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax ether <number> use <mode> Options <number> • ether port number Set a port number to use with a decimal value.
• metal Use 10/100/1000BASE-T ports (RJ45) • fiber Use SFP Ports. *The 100BASE-FX module can be used by XG0224 / XG0448. • auto Automatically selects media type. *However, if both Ethernet and SFP ports are connected the SFP ports are used.
Chapter 5 Command Reference 5.1.1.4 ether mode Function Set the link speed. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR Syntax ether <number> mode <speed> Options <number> • ether port number Set a port number to use with a decimal value. When setting multiple port numbers, separate them with commas (,).
Chapter 5 Command Reference 5.1.1.5 ether duplex Function Set the full-duplex or half-duplex link mode. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR Syntax ether <number> duplex <duplex> Options <number> • ether port number Set a port number to use with a decimal value. When setting multiple port numbers, separate them with commas (,).
Chapter 5 Command Reference 5.1.1.6 ether mdi Function Set the MDI. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR Syntax ether <number> mdi <mode> Options <number> • ether port number Set a port number to use with a decimal value. When setting multiple port numbers, separate them with commas (,).
Chapter 5 Command Reference 5.1.1.7 ether flowctl Function Set the flow control function. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax ether <number> flowctl <send> <receive> Options <number> • ether port number Set a port number to use with a decimal value.
: The receive frames of the source port are mirrored. : The send frames of the source port are mirrored. both : Both the send and receive frames of the source port are mirrored. [XG0224 / XG0448 / XG0440DC / XG0440DCR]...
Page 98
Chapter 5 Command Reference <group> • Group number Set a link aggregation group number with a decimal number. Range Model 1 to 13 XG0224 1 to 26 XG0448 1 to 22 XG0440DC / XG0440DCR 1 to 10 XG2600 Set a backup group number with a decimal number.
Page 99
• The storm control to the same port where the mirror target port was set becomes invalid. [XG0224 / XG0448 / XG0440DC / XG0440DCR] • Only a single port can be set as the mirrored target port on the device.
Page 100
XG Series User's Guide Chapter 5 Command Reference Default It is assumed that the normal port has been specified. ether <number> type normal Port Information Settings...
Chapter 5 Command Reference 5.1.1.9 ether vlan tag Function Set the tagged VLAN. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax ether <number> vlan tag <tagged_vidlist> Options <number> • ether port number Set a port number to use with a decimal value.
XG Series User's Guide Chapter 5 Command Reference 5.1.1.10 ether vlan untag Function Set the untagged VLAN. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax ether <number> vlan untag <untagged_vidlist> Options <number> • ether port number Set a port number to use with a decimal value.
XG Series User's Guide Chapter 5 Command Reference 5.1.1.11 ether egress permission Function Set the forwarding permission port list information. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax ether <number> egress permission <portlist> Options <number> • ether port number Set a port number to use with a decimal value.
XG Series User's Guide Chapter 5 Command Reference 5.1.1.13 ether loopdetect frame Function Enable the Loop Detection Frame sender. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax ether <number> loopdetect frame <target> Options <number> • ether port number Set a port number to use with a decimal value.
XG Series User's Guide Chapter 5 Command Reference 5.1.1.14 ether startup Function Set the offline status when it is started up. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax ether <number> startup <mode> Options <number> • ether port number Set a port number to use with a decimal value.
Chapter 5 Command Reference 5.1.1.15 ether recovery limit Function Set the upper limit number of linkdown times. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax ether <number> recovery limit <limit> Options <number> • ether port number Set a port number to use with a decimal value.
Chapter 5 Command Reference 5.1.1.16 ether downrelay port Function Set the linked port list information about the Linkdown Relay function. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax ether <number> downrelay port <portlist> Options <number> • ether port number Set a port number to use with a decimal value.
5.1.1.17 ether downrelay recovery mode Function Set offline state release operation on the Linkdown Relay function of the Ethernet port. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax ether <number> downrelay recovery mode <mode> Options <number>...
5.1.1.18 ether downrelay recovery cause Function Set the target parameters for releasing the offline state on the Linkdown Relay function of the Ethernet port. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax ether <number> downrelay recovery cause <cause> Options <number>...
XG Series User's Guide Chapter 5 Command Reference 5.1.1.19 ether description Function Define the text description for a ether port Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax ether <number> description <description> Options <number> • The Ethernet port number Set a port number to use with a decimal value.
XG Series User's Guide Chapter 5 Command Reference 5.1.1.20 linkaggregation algorithm Function Set the load distribution algorithm of link aggregation. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax linkaggregation <group> algorithm <type> Options <group> • Link aggregation group number Set a link aggregation group number with a decimal number.
XG Series User's Guide Chapter 5 Command Reference 5.1.1.21 linkaggregation mode Function Set the link aggregation operation mode. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax linkaggregation <group> mode <la_mode> Options <group> • Link aggregation group number Set a link aggregation group number with a decimal number.
XG Series User's Guide Chapter 5 Command Reference 5.1.1.22 linkaggregation type Function Set a link aggregation type. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax linkaggregation <group> type normal linkaggregation <group> type backup <backup_group> <priority> Options <group>...
<group> type normal 5.1.1.23 linkaggregation collecting minimum Function Set the minimum number of member ports for link aggregation. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax linkaggregation <group> collecting minimum <count> Options <group> • Link aggregation group number Set a link aggregation group number with a decimal number.
Chapter 5 Command Reference 5.1.1.24 linkaggregation icmpwatch address Function Set the destination address for "ether" L3 monitoring of link aggregation. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax linkaggregation <group> icmpwatch address <dst_addr> Options <group> • Link aggregation group number Set a link aggregation group number with a decimal number.
Chapter 5 Command Reference 5.1.1.26 linkaggregation downrelay port Function Set the linked port list information about the linkaggregation Linkdown Relay function. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax linkaggregation <group> downrelay port <portlist> Options <group>...
Chapter 5 Command Reference 5.1.1.27 linkaggregation downrelay recovery mode Function Set offline state release operation on the Linkdown Relay function of linkaggregation. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax linkaggregation <group> downrelay recovery mode <mode> Options <group>...
5.1.1.28 linkaggregation downrelay recovery cause Function Set the target parameters for offline state release in the Linkdown Relay function of the linkaggregation. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax linkaggregation <group> downrelay recovery cause <cause> Options <group>...
Chapter 5 Command Reference 5.1.1.29 linkaggregation description Function Define the text description for a link aggregation group. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax linkaggregation <group> description <description> Options <group> • Link aggregation group number Set a link aggregation group number with a decimal number.
XG Series User's Guide Chapter 5 Command Reference 5.1.1.30 backup mode Function Set the backup port selection method. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax backup <group> mode <mode> Options <group> • Backup group number Set a backup group number with a decimal number.
XG Series User's Guide Chapter 5 Command Reference 5.1.1.31 backup standby Function Set the standby status of backup ports. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax backup <group> standby <mode> Options <group> • Backup group number Set a backup group number with a decimal number.
5.1.2.1 ether mac storm Function Set the broadcast and multicast storm control information. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax XG2600 ether <number> mac storm <threshold_broadcast> <threshold_multicast> <action> XG0224 / XG0448 / XG0440DC / XG0440DCR ether <number>...
Page 124
Use Mode Configuration mode (admin class) Explanation XG0224 / XG0448 / XG0440DC / XG0440DCR Set the broadcast or multicast storm control information. If "discard" or "close" is specified, the systemlog is output when the threshold value is exceeded or the device is restored.
This section explains about the commands related to STP information. 5.1.3.1 ether stp use Function Set the STP availability. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax ether <number> stp use <mode> Options <number> • ether port number Set a port number to use with a decimal value.
Chapter 5 Command Reference 5.1.3.2 ether stp domain cost Function Set the path cost. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax ether <number> stp domain <instance-id> cost {auto|<path_cost>} Options <number> • ether port number Set a port number to use with a decimal value.
Chapter 5 Command Reference 5.1.3.3 ether stp domain priority Function Set the priority. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax ether <number> stp domain <instance-id> priority <priority> Options <number> • ether port number Set a port number to use with a decimal value.
Chapter 5 Command Reference 5.1.3.4 ether stp force-version Function Set the STP Force Protocol Version. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax ether <number> stp force-version <version> Options <number> • ether port number Set a port number to use with a decimal value.
This section explains about the commands related to LLDP Information. 5.1.4.1 ether lldp mode Function Set LLDP function Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax ether <number> lldp mode <mode> Options <number> • ether port number Set a port number to use with a decimal value.
Function Set LLDP information which is sent Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax ether <number> lldp info port-description <mode> ether <number> lldp info system-name <mode> ether <number> lldp info system-description <mode>...
Page 131
XG Series User's Guide Chapter 5 Command Reference • LLDP Information Name Specify LLDP Information Name (TLV of 802.1AB) port-description : Port Description Information (Port Description TLV) system-name : System Name Information (System Name TLV) system-description : Sysrem description Information (System Description TLV) system-capabilities : System Capabilities Information (System Capabilities TLV) management-address...
Chapter 5 Command Reference 5.1.4.3 ether lldp vlan Function Set VLAN for sending LLDP information Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax ether <number> ldp vlan <vlanidlist> Options <number> • ether port number Set a port number to use with a decimal value.
This section explains about the commands related to filter information. 5.1.5.1 ether macfilter Function Set the MAC filter. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax ether <number> macfilter <count> <action> <acl> Options <number> • ether port number Set a port number to use with a decimal value.
Page 134
XG Series User's Guide Chapter 5 Command Reference Note 2. The packet filtering default value is "pass". No packets are filtered if only "pass" is set in <action>. [XG2600] Note 3. "acl mac llc" definitions can not filter llc frames with the VLAN tag. Note 4.
Page 135
XG Series User's Guide Chapter 5 Command Reference "vlan protocol" commands "ether macfilter" command A smaller Ethernet port number has a higher priority among Ethernet ports. "vlan macfilter" command A smaller VLAN ID has a higher priority among VLANs. "lan ip filter" command A smaller lan definition number has a higher priority among lans.
Page 136
XG Series User's Guide Chapter 5 Command Reference • Upper limit based on "actions" 16 actions for the entire device. Up to16 actions can be set for the entire device, including the "ether qos aclmap", "vlan aclmap", "lan ip dscp", "vlan protocol"...
Page 137
XG Series User's Guide Chapter 5 Command Reference [XG0224 / XG0448 / XG0440DC / XG0440DCR] Note 3. This command is unavailable if the allowable upper limit for the device is exceeded. The allowable upper limits are as follows. • Upper limit based on "commands"...
Chapter 5 Command Reference 5.1.5.2 ether macfilter move Function Change the priority of MAC filter. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax ether <number> macfilter move <count> <new_count> Options <number> • ether port number Set a port number to use with a decimal value.
This section explains about the commands related to QoS information. 5.1.6.1 ether qos aclmap Function Set the Quality of Service (QoS) conversion. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax ether <number> qos aclmap <count> <action> <value> <acl> Options <number> • ether port number Set a port number to use with a decimal value.
Page 140
A larger value indicates a queue with a higher output priority. Range Model 0 to 7 XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 <acl> • ACL definition number Specify the ACL definition number of the access control list where the packet pattern to configure QoS conversion has been defined.
Page 141
XG Series User's Guide Chapter 5 Command Reference Note 4. This command is unavailable if the allowable upper limit for the device is exceeded. The allowable upper limits are as follows. • Upper limit based on "commands" 64 commands for the entire device. Up to 64 commands can be set for the entire device, including the "ether macfilter",...
Page 142
XG Series User's Guide Chapter 5 Command Reference The following is the number of masks for ACL.. number of masks "acl mac" define LSAP of llc not define LSAP of llc "acl vlan" not define src IP address not define tos/dscp value not define tos/dscp value define src IP address not define dst IP address...
Page 143
When the port type of the Ethernet port is a link aggregation, the same setting is needed in all the member ports where the link aggregation is composed. [XG0224 / XG0448 / XG0440DC / XG0440DCR] Note 2. If a queue is selected by <action> and if this queue has not been associated with the cos value by the "qos cosmap"...
5.1.6.2 ether qos aclmap move Function Change the QoS conversion priority of the Ethernet port. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax ether <number> qos aclmap move <count> <new_count> Options <number> • ether port number Set a port number to use with a decimal value.
Chapter 5 Command Reference 5.1.6.3 ether qos priority Function Set the priority. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax ether <number> qos priority <queue_priority> Options <number> • ether port number Set a port number to use with a decimal value.
Set each of them from 800m to 4000m or 1g to 4g (bps). • Weight of queues [XG0224 / XG0448 / XG0440DC / XG0440CR] Set the weight of 8 queues as the number of packets to send if "wrr" is specified in <mode>.
XG Series User's Guide Chapter 5 Command Reference 5.1.6.5 ether qos prioritymap Function Assign the priority to the queue Available Model XG2600 Syntax ether <number> qos prioritymap <priority> <queue> Options <number> • ether port number Set a port number to use with a decimal value. When setting multiple port numbers, separate them with commas (,).
This section explains about the commands related to LACP information. 5.1.7.1 ether lacp port-priority Function Set the LACP port priority. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax ether <number> lacp port-priority <priority> Options <number> • ether port number Set a port number to use with a decimal value.
This section explains about the commands related to ether L3 monitor information. 5.1.8.1 ether icmpwatch address Function Set the destination address for Ethernet L3 monitoring. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax ether <number> icmpwatch address <dst_addr> Options <number> • ether port number Set a port number to use with a decimal value.
Chapter 5 Command Reference 5.1.8.2 ether icmpwatch interval Function Set various types of "ether" L3 monitoring intervals. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax ether <number> icmpwatch interval <interval> <timeout> [<retry>] Options <number> • ether port number Set a port number to use with a decimal value.
This section explains about the commands related to ether SNMP Information. 5.1.9.1 ether snmp trap linkdown Function Enable/disable a linkdown trap for a specified ether port. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax ether <number> snmp trap linkdown <mode> Options <number> • ether port number Set a port number to use with a decimal value.
Chapter 5 Command Reference 5.1.9.2 ether snmp trap linkup Function Enable/disable a linkup trap for a specified ether port. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax ether <number> snmp trap linkup <mode> Options <number> • ether port number Set a port number to use with a decimal value.
XG Series User's Guide Chapter 5 Command Reference 5.1.10 ether output rate control information This section explains about the commands related to ether output rate control information. 5.1.10.1 ether ratecontrol Function Set output rate limit of ether port Available Model XG2600 Syntax ether <number>...
This section explains about the commands related to LACP information. 5.2.1.1 lacp system-priority Function Set the LACP system priority. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax lacp system-priority <priority> Options <priority> • Priority of LACP system Set the device priority with a decimal value from 1 to 65535.
Chapter 5 Command Reference 5.2.1.2 lacp bpdu Function Set the BPDU forwarding mode of the LACP. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax lacp bpdu <mode> Options <mode> • on Specify the BPDU forwarding mode.
The VLAN ID, which is to be specified in <vid> of [Options] described in each command of this section, shall be within the range specified as shown below. Range Model 1 to 4094 XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 5.3.1 VLAN Common Information This section explains about the commands related to VLAN common information. 5.3.1.1...
XG Series User's Guide Chapter 5 Command Reference 5.3.1.2 vlan protocol Function Set the protocol VLAN. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax vlan <vid> protocol <protocol-type> vlan <vid> protocol <count> <frame-type> <ether-type> Options <vid> • VLAN ID Specify a decimal VLAN ID from 2 to 4094.
Page 158
XG Series User's Guide Chapter 5 Command Reference <ether-type> Specify the Ethertype or LLC value if the protocol is defined by the user. • Specify the Ethertype value for Ethernet II format or IEEE 802.3 SNAP format frames, or specify an LLC value (DSAP or SSAP) for IEEE 802.3 LLC format frames, using a 4- digit hexadecimal value (from 0000 to ffff).
Page 159
XG Series User's Guide Chapter 5 Command Reference [XG2600] • The Max definition number of "vlan protocol" definitions is 16. • If there are "vlan protocol" definitions over 16, the definition, the VLAN and the ports belong to the VLAN are invalid. •...
Chapter 5 Command Reference 5.3.1.3 vlan forward Function Set static forwarding rules setting. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax vlan <vid> forward <count> <dst_addr> <port> Options <vid> • VLAN ID Specify a VLAN ID with a decimal value.
Chapter 5 Command Reference 5.3.1.4 vlan description Function Set description for VLAN Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax vlan <vid> description <description> Options <vid> • VLAN ID Specify VLAN ID with a decimal value from 0 to 4094 <description>...
This section explains about the commands related to IGMP snooping information. 5.3.2.1 vlan igmpsnoop router Function Set the multicast router port. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax vlan <vid> igmpsnoop router <mode> [<portlist>] Options <vid> • VLAN ID Specify a VLAN ID with a decimal value.
Chapter 5 Command Reference 5.3.2.2 vlan igmpsnoop querier Function Set the Querier operations. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax vlan <vid> igmpsnoop querier <mode> Options <vid> • VLAN ID Specify a VLAN ID with a decimal value.
Chapter 5 Command Reference 5.3.2.3 vlan igmpsnoop source Function Set the IP address to be used for IGMP snooping. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax vlan <vid> igmpsnoop source <address> Options <vid> • VLAN ID Specify a VLAN ID with a decimal value.
Chapter 5 Command Reference 5.3.2.4 vlan igmpsnoop proxy Function Set the IGMP proxy mode. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax vlan <vid> igmpsnoop proxy <mode> Options <vid> • VLAN ID Specify a VLAN ID with a decimal value.
This section explains about the commands related to filter information. 5.3.3.1 vlan macfilter Function Set the MAC filter for VLAN. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax vlan <vid> macfilter <count> <action> <acl> Options <vid> • VLAN ID Specify a VLAN ID with a decimal value.
Page 167
XG Series User's Guide Chapter 5 Command Reference Caution Note 1. If none of "acl mac", "acl vlan" and "acl ip" definitions exist on the access control list which has been specified by <acl> or if the access control list specified by <acl> does not exist, the packets are not filtered.
Page 168
XG Series User's Guide Chapter 5 Command Reference "ether qos aclmap" command A smaller Ethernet port number has a higher priority among Ethernet ports. "vlan qos aclmap" command A smaller VLAN ID has a higher priority among VLANs. "lan ip dscp" command A smaller lan definition number has a higher priority among lans.
Page 169
If same <vid> is used, the commands use 1 action for them. - vlan <vid> protocol <count> ether - vlan <vid> protocol <count> llc [XG0224 / XG0448 / XG0440DC / XG0440DCR] Note 3. This command is unavailable if the allowable upper limit for the device is exceeded.
Page 170
XG Series User's Guide Chapter 5 Command Reference - For ACL to set ICMP Result of multiplication between the number of ICMP TYPEs and the number of ICMP CODEs for ICMP - For ACL not to set TCP, UDP, or ICMP You can expand the upper limit to use "resource filter distribution"...
Chapter 5 Command Reference 5.3.3.2 vlan macfilter move Function Change the priority of VLAN MAC filter. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax vlan <vid> macfilter move <count> <new_count> Options <vid> • VLAN ID Specify a VLAN ID with a decimal value.
Chapter 5 Command Reference 5.3.3.3 vlan ip6filter Function Set VLAN IPv6 filter Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR Syntax vlan <vid> ip6filter <count> <action> <acl> Options <vid> • VLAN ID Specify the VLAN ID with a decimal value from 1 to 4094.
Page 173
XG Series User's Guide Chapter 5 Command Reference "vlan ip6filter" command A smaller VLAN ID has a higher priority among VLANs. "lan ip6 filter" command A smaller lan definition number has a higher priority among lans. If up to 128 of "vlan ip6filter"...
Chapter 5 Command Reference 5.3.3.4 vlan ip6filter move Function Change the priority of VLAN IPv6 filter Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR Syntax vlan <vid> ip6filter move <count> <new_count> Options <vid> • VLAN ID Specify VLAN ID with a decimal value from 1 to 4094 <count>...
This section explains about the commands related to QoS information. 5.3.4.1 vlan qos aclmap Function Set the QoS conversion of the VLAN. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax vlan <vid> qos aclmap <count> <action> <value> <acl> Options <vid> • VLAN ID Specify a VLAN ID with a decimal value.
Page 176
A larger value indicates a queue with a higher output priority. Range Model 0 to 7 XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 <acl> • ACL definition number Specify the ACL definition number of the access control list where the packet pattern to configure QoS conversion has been defined.
Page 177
XG Series User's Guide Chapter 5 Command Reference "ether macfilter" command A smaller Ethernet port number has a higher priority among Ethernet ports. "vlan macfilter" command A smaller VLAN ID has a higher priority among VLANs. "lan ip filter" command A smaller lan definition number has a higher priority among lans.
Page 178
XG Series User's Guide Chapter 5 Command Reference The number of masks that each command use depends on applied ACL. When Multiple ACL are applied, the number of masks amount to sum total, and depends on ACLs the number of masks amount to less than sum total. The following is the number of masks for ACL.
Page 179
If same <vid> is used, the commands use 1 action for them. - vlan <vid> protocol <count> ether - vlan <vid> protocol <count> llc [XG0224 / XG0448 / XG0440DC / XG0440DCR] Note 2. If a queue is selected by <action> and if this queue has not been associated with the cos value by the "qos cosmap"...
It is assumed that this option has not been set. 5.3.4.2 vlan qos aclmap move Function Change the priority of QoS for VLAN Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax vlan <vid> qos aclmap move <count> <new_count> Options <vid> • VLAN ID Specify the VLAN ID with a decimal value from 1 to 4094 <count>...
Chapter 5 Command Reference 5.3.4.3 vlan ip6qos aclmap Function Set IPv6 QoS of VLAN Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR Syntax vlan <vid> ip6qos aclmap <count> <action> <value> <acl> Options <vid> • VLAN ID Specify the VLAN ID with a decimal value from 1 to 4094 <count>...
Page 182
XG Series User's Guide Chapter 5 Command Reference Caution Note1. If none of "acl ip6" definition exist on the access control list which has been specified by <acl> or if the access control list specified by <acl> does not exist, the QoS processing is not applied to those packets.
Chapter 5 Command Reference 5.3.4.4 vlan ip6qos aclmap move Function Change the priority of IPv6 QoS for VLAN Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR Syntax vlan <vid> ip6qos aclmap move <count> <new_count> Options <vid> • VLAN ID Specify the VLAN ID with a decimal value from 1 to 4094 <count>...
This section explains about the commands related to MAC information. 5.4.1.1 mac learning Function Set the MAC address learning. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax mac learning <mode> Options <mode> • on Enable automatic learning of the MAC address.
Chapter 5 Command Reference 5.4.1.2 mac age Function Set the aging-out time of MAC address learning table. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax mac age <time> Options <time> • Aging-out time Set the aging-out time of MAC address learning table in seconds.
MAC Table Flush Information 5.4.2.1 mac flush address Function Set the MAC address for monitoring. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR Syntax mac flush <count> address <mac_addr> Options <count> • Definition Number Specify a decimal value from 0 to 3.
Chapter 5 Command Reference 5.4.2.2 mac flush mode Function Set the learning table initialization mode. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR Syntax mac flush <count> mode <flush-mode> Options <count> • Definition Number Specify a decimal value from 0 to 3.
[Options] described in each command of this section, shall be within the range for each model as shown below. Range Model 0 to 99 XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 5.5.1 IPv4 Related Information This section explains about the commands related to IPv4 related information.
Chapter 5 Command Reference 5.5.1.2 lan ip address Function Set the IP address. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax lan [<number>] ip address <address>/<mask> <broadcast> Options <number> • lan definition number Specify a lan definition serial number with a decimal value.
Chapter 5 Command Reference 5.5.1.3 lan ip route Function Set the IPv4 static route information. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax lan [<number>] ip route <count> <address>/<mask> <next_hop> [<distance>] Options <number> • lan definition number Specify a lan definition serial number with a decimal value.
Chapter 5 Command Reference 5.5.1.4 lan ip filter Function Set the IP filter. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax lan [<number>] ip filter <count> <action> acl <acl_count> Options <number> • lan definition number Specify a lan definition serial number with a decimal value.
Page 192
XG Series User's Guide Chapter 5 Command Reference Explanation Set the IP filter for the LAN interface. The IP filter is used to transmit or reject packets that have matched the address, protocol, TOS or DSCP value, port number, ICMP TYPE, and ICMP CODE specified in ACL. Checking whether the conditions are satisfied or not according to the set priority, if a packet that has satisfied those conditions is found, it is filtered, and the subsequent setting will be ignored.
Page 193
XG Series User's Guide Chapter 5 Command Reference "ether macfilter" command A smaller Ethernet port number has a higher priority among Ethernet ports. "vlan macfilter" command A smaller VLAN ID has a higher priority among VLANs. "lan ip filter" command A smaller lan definition number has a higher priority among lans.
Page 194
If same <vid> is used, the commands use 1 action for them. - vlan <vid> protocol <count> ether - vlan <vid> protocol <count> llc [XG0224 / XG0448 / XG0440DC / XG0440DCR] Note 3. This command is unavailable if the allowable upper limit for the device is exceeded.
Page 195
XG Series User's Guide Chapter 5 Command Reference If up to 128 of "ether macfilter" commands have been defined for port ether1, the subsequent "vlan macfilter" "lan ip filter" command will be no longer applied. • Upper limit based on rule 128 rules for the entire device.
Chapter 5 Command Reference 5.5.1.5 lan ip filter move Function Change the IP filter priority. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax lan [<number>] ip filter move <count> <new_count> Options <number> • lan definition number Specify a lan definition serial number with a decimal value.
Chapter 5 Command Reference 5.5.1.6 lan ip dscp Function Set the DSCP value rewriting conditions. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax lan [<number>] ip dscp <count> acl <acl_count> <new_dscp> Options <number> • lan definition number Specify a lan definition serial number with a decimal value.
Page 198
XG Series User's Guide Chapter 5 Command Reference Explanation Set DSCP value rewriting conditions. Rewrite the DSCP value of a packet, which has satisfied conditions, to the specified DSCP value. Caution Note 1. If none of "acl ip" definition exist on the access control list which has been specified by <acl>...
Page 199
XG Series User's Guide Chapter 5 Command Reference "ether qos aclmap" command A smaller Ethernet port number has a higher priority among Ethernet ports. "vlan qos aclmap" command A smaller VLAN ID has a higher priority among VLANs. "lan ip dscp" command A smaller lan definition number has a higher priority among lans.
Page 200
If same <vid> is used, the commands use 1 action for them. - vlan <vid> protocol <count> ether - vlan <vid> protocol <count> llc [XG0224 / XG0448 / XG0440DC / XG0440DCR] Note 2. This command is unavailable if the allowable upper limit for the device is exceeded.
It is assumed that DSCP value rewriting is not performed. 5.5.1.7 lan ip dscp move Function Change the priority of DSCP value rewriting conditions. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax lan [<number>] ip dscp move <count> <new_count> Options <number> • lan definition number Specify a lan definition serial number with a decimal value.
Chapter 5 Command Reference 5.5.1.8 lan ip arp static Function Sets static ARP. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR Syntax lan [<number>] ip arp static <count> <dst> <mac> Options <number> • Defined LAN number The sequential number of a LAN definition expressed in base 10.
This section explains about the commands related to IPv6 Related Information. 5.5.2.1 lan ip6 use Function Set IPv6 function Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax lan [<number>] ip6 use <mode> Options <number> • lan definition number Specify lan definition number with a decimal value <mode>...
Chapter 5 Command Reference 5.5.2.3 lan ip6 address Function Set IPv6 address Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax lan [<number>] ip6 address [<count>] <address>/<prefixlen> Options <number> • lan definition number Specify lan definition number with a decimal value <count>...
Chapter 5 Command Reference 5.5.2.5 lan ip6 route Function Set IPv6 static route information Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax lan [<number>] ip6 route <count> <address>/<prefixlen> <next_hop> [<distance>] Options <number> • lan definition number Specify lan definition number with a decimal value <count>...
Chapter 5 Command Reference 5.5.2.6 lan ip6 filter Function Set IPv6 filter Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR Syntax lan [<number>] ip6 filter <count> <action> acl <acl_count> Options <number> • lan definition number Specify lan definition number with a decimal number <count>...
Page 207
XG Series User's Guide Chapter 5 Command Reference Note 3. This command is unavailable if the allowable upper limit for the device is exceeded. The allowable upper limits are as follows. • Upper limit based on "commands" 128 commands for the entire device. Up to 128 commands can be set for the entire device, including the "vlan ip6filter"...
Chapter 5 Command Reference 5.5.2.7 lan ip6 filter move Function Change priority of IPv6 filter Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR Syntax lan [<number>] ip6 filter move <count> <new_count> Options <number> • lan definition number Specify lan definition number with a decimal value <count>...
Chapter 5 Command Reference 5.5.2.8 lan ip6 dscp Function Set DSCP value rewrite condition Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR Syntax lan [<number>] ip6 dscp <count> acl <acl_count> <new_dscp> Options <number> • lan definition number Specify lan definition number with a decimal value <count>...
Page 210
XG Series User's Guide Chapter 5 Command Reference "vlan ip6qos aclmap" command A smaller VLAN ID has a higher priority among VLANs. "lan ip6 dscp" command A smaller lan definition number has a higher priority among lans. If up to 128 of "vlan ip6qos aclmap"...
Chapter 5 Command Reference 5.5.2.9 lan ip6 dscp move Function Change priority of DSCP value rewrite condition Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR Syntax lan [<number>] ip6 dscp move <count> <new_count> Options <number> • lan definition number Specify lan definition number with a decimal value <count>...
This section explains about the commands related to VLAN related information. 5.5.3.1 lan vlan Function Set a VLAN ID. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax lan [<number>] vlan <vid> Options <number> • lan definition number Specify a lan definition serial number with a decimal value.
This section explains about the commands related to LLMNR Related Information. 5.5.4.1 lan llmnr use Function Set to use the LLMNR function. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax lan [<number>] llmnr use <mode> Options <number> • lan definition number Specify a lan definition serial number with a decimal value.
XG Series User's Guide Chapter 5 Command Reference 5.5.5 Management LAN port IPv4 Related Information This section explains about the commands related to Management LAN port IPv4 Related Information. 5.5.5.1 oob ip address Function Set IP address of oob port Available Model XG2600 Syntax...
XG Series User's Guide Chapter 5 Command Reference 5.5.5.2 oob ip route Function Set the IPv4static route information Available Model XG2600 Syntax oob ip route <count> <address>/<mask> <next_hop> [<distance>] Options <count> • Static route information definition number Specify a static route information definition number with a decimal value. Range Model 0 to 199...
XG Series User's Guide Chapter 5 Command Reference 5.5.6 Management LAN port IPv6 Related Information This section explains about the commands related to Management LAN port IPv6 Related Information. 5.5.6.1 oob ip6 use Function Set IPv6 function of oob port Available Model XG2600 Syntax...
XG Series User's Guide Chapter 5 Command Reference 5.5.6.3 oob ip6 address Function Set IPv6 address Available Model XG2600 Syntax oob ip6 address [<count>] <address>/<prefixlen> Options <count> • IPv6 address definition number Specify IPv6 address definition number with a decimal value from 0 to 3. <address>/<prefixlen>...
XG Series User's Guide Chapter 5 Command Reference 5.5.6.5 oob ip6 route Function Set IPv6 static route information Available Model XG2600 Syntax oob ip6 route <count> <address>/<prefixlen> <next_hop> [<distance>] Options <count> • Static route information definition number Specify static route information definition number with a decimal value Range Model 0 to 199...
Sender The LLMNR function to The hostname of this device is set by "sysname" command, and the default hostname is Model name (e.c. XG0224). Caution • "lan llmnr use" (lan llmnr use on) and "oob llmnr use" (oob llmnr use on) definitions can be set only 2 definitions for the entire device/ •...
5.6.1.1 ip arp age Function Set a valid time of ARP entry. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax ip arp age <time> Options <time> Set a valid time (minutes) of ARP entry with a decimal value from 1 to 240.
This section explains about the commands related to QoS information. 5.7.1.1 qos cosmap Function Set the correspondence between the COS value and storage queue for a specific packet. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR Syntax qos cosmap <cos> <queue> Options <cos> • cos value...
5.8.1.1 stp mode Function Set the STP (Spanning Tree Protocol) operation mode. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax stp mode {disable | stp | rstp | mstp } Options disable • Specify when STP is not used.
Chapter 5 Command Reference 5.8.1.2 stp age Function Set a maximum valid time of bridge configuration. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax stp age <max_age> Options <max_age> • Maximum valid time Specify a valid time of the BPDU information sent from the root bridge within the range of 6 to 40 seconds.
Chapter 5 Command Reference 5.8.1.3 stp delay Function Set a maximum forward delay time. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax stp delay <delay_time> Options <delay_time> • Maximum forward delay time Specify a maximum forward delay time within the range of 4 to 30 seconds.
Chapter 5 Command Reference 5.8.1.4 stp hello Function Set a Hello message transmission interval. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax stp hello <time> Options <time> • Transmission interval Specify a transmission interval of configuration BPDU to be sent periodically after this device becomes a root bridge, within the range of 1 to 10 seconds.
Chapter 5 Command Reference 5.8.1.6 stp domain priority Function Set the bridge priority. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax stp domain <instance-id> priority <priority> Options <instance-id> • STP instance ID number Specify a decimal value from 0 to 15.
Chapter 5 Command Reference 5.8.1.7 stp config_id Function Set the MST configuration. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax stp config_id <region_name> <revision_level> Options <region_name> • Region name (Configuration name) Specify a configuration name using up to 32 characters from 0x21, 0x23 to 0x7e ASCII set.
Chapter 5 Command Reference 5.8.1.9 stp max-hops Function Set a maximum hop count of bridge configuration. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax stp max-hops <hop_count> Options <hop_count> • Maximum hop count Specify a decimal value from 1 to 40.
This section explains about the commands related to LLDP Information. 5.9.1.1 lldp send interval Function Set LLDP send interval Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax lldp send interval <interval> <delay> Options <interval> • LLDP send interval Specify LLDP send interval with a decimal value with h (hours), m (minutes), s (seconds) It can be specified from 5 seconds to 32768 seconds.
Chapter 5 Command Reference 5.9.1.2 lldp send hold Function Set LLDP hold times Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax lldp send hold <count> Options <count> • LLDP hold times Specify LLDP hold time which neighbor device holds LLDP information of this device.
Chapter 5 Command Reference 5.9.1.4 lldp notification interval Function Set minimal interval of SNMP Notification Trap Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax lldp notification interval <interval> Options <interval> • Trap minimal interval Specify minimal interval of SNMP Notification Trap with a decimal value with h (hours), m (minutes), s (seconds) from 5 seconds to 3600 seconds.
This section explains about the commands related to IGMP snooping information. 5.10.1.1 igmpsnoop use Function Set the IGMP snooping function. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax igmpsnoop use <mode> Options <mode> Specify the IGMP snooping mode.
Loop Detection Information This section explains about the commands related to Loop Detection information. 5.11.1.1 loopdetect use Function Set the Loop Detection function. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax loopdetect use <mode> Options <mode> • on Enable the Loop Detection function.
XG Series User's Guide Chapter 5 Command Reference 5.11.1.2 loopdetect portdisable Function Set the port offline mode. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax loopdetect portdisable <mode> Options <mode> • yes Place the port offline automatically.
XG Series User's Guide Chapter 5 Command Reference 5.11.1.4 loopdetect interval Function Set a transmission interval of the Loop Detection frame. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax loopdetect interval <time> Options <time> • Transmission interval Specify a transmission interval of the loop detection frame with a value from 1 to 32767 seconds.
5.12.1.1 acl mac Function Set the definition of the ACL MAC. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax acl <acl_count> mac <src_mac> <dst_mac> llc <value> acl <acl_count> mac <src_mac> <dst_mac> ether <value> acl <acl_count> mac <src_mac> <dst_mac> any Options <acl_count>...
Any etherframe pattern can be specified in the ACL definition. 5.12.1.2 acl vlan Function Set the definition of the ACL VLAN. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax acl <acl_count> vlan <vid> <cos> Options <acl_count>...
5.12.1.3 acl ip Function Set the definition of the ACL IPv4. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax acl <acl_count> ip <src_addr>/<mask> <dst_addr>/<mask> [<protocol> [any]] acl <acl_count> ip <src_addr>/<mask> <dst_addr>/<mask> [<protocol> [tos <value>]] acl <acl_count> ip <src_addr>/<mask> <dst_addr>/<mask> [<protocol> [dscp <value>]] Options <acl_count>...
Page 241
XG Series User's Guide Chapter 5 Command Reference • TOS value Specify the TOS value used to identify the ACL target with a hexadecimal value from 0 to ff. • DSCP value Specify the DSCP value used to identify the ACL target with a decimal value from 0 to Use Mode Configuration mode (admin class) Explanation...
XG Series User's Guide Chapter 5 Command Reference 5.12.1.5 acl tcp Function Set the definition of the ACL TCP. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax acl <acl_count> tcp <src_port> <dst_port> Options <acl_count> • ACL definition number Specify an ACL definition serial number with a decimal value.
XG Series User's Guide Chapter 5 Command Reference 5.12.1.6 acl udp Function Set the definition of the ACL UDP. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax acl <acl_count> udp <src_port> <dst_port> Options <acl_count> • ACL definition number Specify an ACL definition serial number with a decimal value.
XG Series User's Guide Chapter 5 Command Reference 5.12.1.7 acl icmp Function Set the definition of the ACL ICMP. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax acl <acl_count> icmp <icmptype> <icmpcode> Options <acl_count> • ACL definition number Specify an ACL definition serial number with a decimal value.
XG Series User's Guide Chapter 5 Command Reference 5.12.1.8 acl description Function Set the definition of the ACL description. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax acl <acl_count> description <description> Options <acl_count> • ACL definition number Specify an ACL definition serial number with a decimal value.
Range Model 0 to 9 XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Allowed range of AAA user information definition number The group serial number (decimal value), which is to be specified in [<number>] (AAA user information definition number) described in [Options] of each command, shall be within the range as shown below.
This section explains about the commands related to group ID information. 5.13.1.1 aaa name Function Set a group name. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax aaa [<group_id>] name <group_name> Options <group_id> • Group ID Specify a group ID with a serial decimal value.
This section explains about the commands related to AAA user information. 5.13.2.1 aaa user id Function Set the authentication information (user ID). Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax aaa [<group_id>] user [<number>] id <id> Options <group_id>...
XG Series User's Guide Chapter 5 Command Reference 5.13.2.2 aaa user password Function Set the authentication information (password). Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax aaa [<group_id>] user [<number>] password <password> [encrypted] Options <group_id> • Group ID Specify a group ID with a serial decimal value.
XG Series User's Guide Chapter 5 Command Reference 5.13.2.3 aaa user user-role Function Sets user privilege class. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax aaa [<group_id>] user [<number>] user-role <class> Options <group_id> • Group ID Set group IDs using a base 10 sequential serial number.
This section explains about the commands related to RADIUS information. 5.13.3.1 aaa radius service Function Set the RADIUS service. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax aaa [<group_id>] radius service <service> [<type>] Options <group_id> • Group ID Specify a group ID with a serial decimal value.
Chapter 5 Command Reference 5.13.3.2 aaa radius auth source Function Set the local IP address of the RADIUS authentication device. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax aaa [<group_id>] radius auth source <address> Options <group_id>...
XG Series User's Guide Chapter 5 Command Reference 5.13.3.3 aaa radius auth message-authenticator Function Set the Message-Authenticator. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax aaa [<group_id>] radius auth message-authenticator <mode> Options <group_id> • Group ID Specify a group ID with a serial decimal value.
5.13.3.6 aaa radius client server-info auth port Function Specify UDP port of the authentication server (the old RFC specifications compatible). Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax aaa [<group_id>] radius client server-info auth [<number>] port <port> Options <group_id>...
Chapter 5 Command Reference 5.13.3.8 aaa radius client server-info auth priority Function Set the priority. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax aaa [<group_id>] radius client server-info auth [<number>] priority <priority> Options <group_id> • Group ID Specify a group ID with a serial decimal value.
This section explains about password information. 5.14.1 password format Function Sets format for encrypted password strings. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax password format <format> Options <format> Format for encrypted password strings • common Common password format Encrypted password strings that can be used by other devices.
5.14.2 password admin set Function Set an administrator password. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax password admin set [<password> [encrypted]] Options <password> • Password Specify a password using up to 64 characters from, 0x21,0x23 to 0x3e,0x40 to 0x7e ASCII set.
Page 264
XG Series User's Guide Chapter 5 Command Reference Retype password: The <password> option is not set. Retype the password for administrator interactivery. <WARNING> weak admin password: set the password The administrator password is not set. Set an administrator password. <WARNING> weak admin password: contain at least 8 characters The administrator password is seven or fewer characters in length.
Chapter 5 Command Reference 5.14.3 password user set Function Set a general user password. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax password user set <password> [encrypted] Options <password> • Password Specify a password using up to 64 characters from 0x21, 0x23 to 0x7e ASCII set.
Chapter 5 Command Reference 5.14.4 password aaa Function Set AAA information of login user Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax password aaa <group_id> Options <group_id> • AAA Group ID Specify AAA group ID with a decimal value...
This section explains about the commands related to SNMP information. 5.15.1.1 snmp service Function Set the SNMP agent and SNMP trap functions. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax snmp service <mode> Options <mode> • on Enable SNMP agent and SNMP trap functions.
Chapter 5 Command Reference 5.15.1.3 snmp agent sysname Function Set the equipment name for the SNMP agent function. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax snmp agent sysname <sysname> Options <sysname> • Equipment name (sysName value) Specify the MIB variable, sysName, which indicates an equipment name of this device, with up to 32 characters.
XG Series User's Guide Chapter 5 Command Reference 5.15.1.5 snmp agent address Function Set the SNMP agent address. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax snmp agent address <address> Options <address> • Agent address Set the agent address of this device.
XG Series User's Guide Chapter 5 Command Reference 5.15.1.7 snmp manager Function Set the SNMP host information. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax snmp manager <manager_number> <address> <community> <trap> [<write>] Options <manager_number> • SNMP host definition number Specify a serial number of SNMP host definition with a decimal value from 0 to 7.
XG Series User's Guide Chapter 5 Command Reference 5.15.1.16 snmp rmon Function Set the RMON function. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax snmp rmon <mode> Options <mode> Specify whether to enable or disable the RMON function.
XG Series User's Guide Chapter 5 Command Reference 5.15.1.18 snmp user address Function Set a SNMP host address. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax snmp user [<number>] address [<addr_number>] <address> Options <number> • User definition number Specify a user definition number with a decimal value from 0 to 7.
XG Series User's Guide Chapter 5 Command Reference 5.15.1.19 snmp user notification Function Set a trap notification host address. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax snmp user [<number>] notification [<addr_number>] <address> Options <number> • User definition number Specify a user definition number with a decimal value from 0 to 7.
XG Series User's Guide Chapter 5 Command Reference 5.15.1.20 snmp user auth Function Set the authentication protocol Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax snmp user [<number>] auth <protocol> [<password> [encrypted]] Options <number> • User definition number Specify the user definition number with a decimal value from 0 to 7.
XG Series User's Guide Chapter 5 Command Reference 5.15.1.21 snmp user priv Function Set encryption protocol Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax snmp user [<number>] priv <protocol> [<password> [encrypted]] Options <number> • User definition number Specify the user definition number with a decimal value from 0 to 7.
XG Series User's Guide Chapter 5 Command Reference 5.15.1.22 snmp user write Function Set the MIB write-enable view. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax snmp user [<number>] write <view_name> Options <number> • User definition number Specify a user definition number with a decimal value from 0 to 7.
XG Series User's Guide Chapter 5 Command Reference 5.15.1.23 snmp user read Function Sets MIB read permission view. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax snmp user [<number>] read <access> [<view_number>] Options <number> • User ID User ID expressed as a base 10 value from 0 to 7.
XG Series User's Guide Chapter 5 Command Reference 5.15.1.24 snmp user notify Function Sets trap notification permission view. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax snmp user [<number>] notify <access> [<view_number>] Options <number> • User ID User ID expressed as a base 10 value from 0 to 7.
XG Series User's Guide Chapter 5 Command Reference 5.15.1.25 snmp view subtree Function SNMP MIB view information Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax snmp view [<view_number>] subtree [<subtree_number>] <view_type> <subtree_name> Options <view_number> • View definition number Specify the view definition number with a decimal value from 0 to 7 The default is 0.
Page 284
XG Series User's Guide Chapter 5 Command Reference Subtree name Object ID Remark Trap name coldstart 1.3.6.1.6.3.1.1.5.1 linkdown 1.3.6.1.6.3.1.1.5.3 linkup 1.3.6.1.6.3.1.1.5.4 authfail 1.3.6.1.6.3.1.1.5.5 newroot 1.3.6.1.2.1.17.0.1 topologychange 1.3.6.1.2.1.17.0.2 noserror 1.3.6.1.4.1.211.1.127.1.0.1 lldpremtableschange 1.0.8802.1.1.2.0.0.1 Use Mode Configuration mode (admin class) Explanation Set MIB view information in SNMPv3 Default Device Information Settings...
This section explains about the commands related to system log information. 5.15.2.1 syslog server address Function Set the server IP address that receives system log information. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax syslog server <number> address <address> Options <number>...
Chapter 5 Command Reference 5.15.2.2 syslog server pri Function Set the severity level for syslog information sent to the syslog servers. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax syslog server <number> pri <mode> Options <number>...
XG Series User's Guide Chapter 5 Command Reference 5.15.2.3 syslog pri Function Set the severity level output to the switch syslog. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax syslog pri <mode> Options <mode> • Priority Specify the priority to output system log information from the following.
XG Series User's Guide Chapter 5 Command Reference 5.15.2.5 syslog security Function Set the security to output the system log information. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax syslog security <securetype> Options <securetype> • Security type Select one of the followings to output the security log information.
XG Series User's Guide Chapter 5 Command Reference 5.15.2.7 syslog command-logging Function Set command execution history output of system log information Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax syslog command-logging <mode> Options <mode> • enable Output command execution history to system log •...
Chapter 5 Command Reference 5.15.2.9 syslog source address Function Set the source IP address of the system log information. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax syslog source address <address> Options <address> Specify the source IPv4 address that is used for sending the system log information.
5.15.3.1 time auto server Function Specify the IP address, protocol, and priority of server(s) that supply time information. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax time auto server <count> address <address> <protocol> [<interface>] Options <count>...
Chapter 5 Command Reference 5.15.3.2 time auto interval Function Set an automatic setting interval of time information. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax time auto interval <time> Options <time> Specify the interval to set time information.
5.15.3.4 time summer-time Function Sets summer time/daylight saving time. Use the no form to return to the default setup. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax time summer-time <start_day> <end_day> [<offset>] Options <start_day> • Specifies the day/time to start Daylight Saving Time in any form of "Mm.w.d/hhmm,"...
Page 294
XG Series User's Guide Chapter 5 Command Reference <offset> • pecifies the time set forward during Daylight Saving Time in the form of "hhmm." - hh Specifies the hour set forward during Daylight Saving Time with a two-digit number. It can be set in the range of 00 to 23. - mm Specifies the minute set forward during Daylight Saving Time with a two-digit number.
5.15.4.1 proxydns domain Function Set the forward lookup conditions for proxy DNS. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax proxydns domain <count> <qtype> <qname> <address>/<mask> reject (Discard the request to forward) proxydns domain <count> <qtype> <qname> <address>/<mask> static <ipaddress>...
Page 296
XG Series User's Guide Chapter 5 Command Reference For the host name, the following wild cards are usable. An execution example is given below. Execution example Matching Character String www.*.com This is considered to match all of the following character strings. •...
Chapter 5 Command Reference 5.15.4.2 proxydns domain move Function Change the forward lookup conditions for proxy DNS. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax proxydns domain move <count> <new_count> Options <count> • Destination definition number before changes Specify a destination definition number to change its order.
5.15.4.3 proxydns address Function Set the reverse lookup conditions for proxy DNS. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax proxydns address <count> <address>/<mask> reject (Discard the request to forward) proxydns address <count> <address>/<mask> static <ipaddress>...
Chapter 5 Command Reference 5.15.4.4 proxydns address move Function Change the reverse lookup conditions for proxy DNS. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax proxydns address move <count> <new_count> Options <count> • Destination definition number before changes Specify a destination definition number to change its order.
This section explains about the commands related to host database information. 5.15.5.1 host name Function Set the host name of the host database information. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax host <number> name <name> Options <number>...
Chapter 5 Command Reference 5.15.5.3 host ip6 address Function Set the IPv6 address of the host database information Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax host <number> ip6 address <ip6_address> Options <number> • definition number Set the definition number of host database information with a decimal value <ip6_address>...
This section explains about the commands related to schedule information. 5.15.6.1 schedule at Function Set the command to specify day and time in the system schedule. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax schedule <number> at <day> <time> <command> Options <number>...
It is assumed that no schedule information is set. 5.15.6.2 schedule syslog Function Set the system log in the system schedule. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax schedule <number> syslog <syslog> Options <number> Specify the schedule definition.
This section explains about the commands related to Filter/QoS Resource Information. 5.15.7.1 resource filter distribution Function Set the distribution of filter and QoS resources. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR Syntax resource filter distribution <function> <protocol> Options <function>...
Other This section explains about other commands. 5.15.8.1 addact Function Set the command execution reservation. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax addact <index> <date> <command> Options <index> • Registration number Specify the registration number of the command execution reservation information.
XG Series User's Guide Chapter 5 Command Reference 5.15.8.4 telnetinfo Function Set the TELNET connection service. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax telnetinfo autologout <time> Options <time> • Automatic disconnection time Specify a time period (from 0 to 86400 seconds (one day)) for the user to be automatically disconnected when no command input/output processing has been performed by the client while connected through telnet.
If unset, dumping of data to external media via a dump switch will be allowed. dumpswitch enable 5.15.8.7 sysname Function Set a name of this device. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax sysname <name> Options <name> • Name Specify a name of this device using up to 32 characters from 0x21, 0x23 to 0x7e ASCII set.
XG Series User's Guide Chapter 5 Command Reference 5.15.8.8 serverinfo ftp Function Set the FTP server function. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax serverinfo ftp ip <mode> Options <mode> • on Enable the FTP server function.
Chapter 5 Command Reference 5.15.8.10 serverinfo ftp filter Function Set the application filter for the FTP server function. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax serverinfo ftp filter <count> <action> acl <acl_count> Options <count> • Filtering definition number Specify a definition number, which indicates a filtering priority, with a decimal value from 0 to 29.
Chapter 5 Command Reference 5.15.8.11 serverinfo ftp filter move Function Change the priority of the application filter for the FTP server function. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax serverinfo ftp filter move <count> <new_count> Options <count>...
XG Series User's Guide Chapter 5 Command Reference 5.15.8.13 serverinfo sftp Function Set the SSH FTP server function. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax serverinfo sftp ip <mode> Options <mode> • on Enable the SSH FTP server function.
XG Series User's Guide Chapter 5 Command Reference 5.15.8.14 serverinfo sftp ip6 Function Set the IPv6 SSH FTP server function Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax serverinfo sftp ip6 <mode> Options <mode> • on Enable IPv6 SSH FTP server function •...
XG Series User's Guide Chapter 5 Command Reference 5.15.8.16 serverinfo telnet ip6 Function Set the IPv6 telnet server function Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax serverinfo telnet ip6 <mode> Options <mode> • on Enable telnet server function •...
It is assumed that the application filter is not set for the TELNET server function. 5.15.8.18 serverinfo telnet filter move Function Change the priority of the application filter for the TELNET server function. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax serverinfo telnet filter move <count> <new_count> Options <count>...
XG Series User's Guide Chapter 5 Command Reference 5.15.8.20 serverinfo ssh Function Set the SSH login server function. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax serverinfo ssh ip <mode> Options <mode> • on Enable the SSH login server function.
XG Series User's Guide Chapter 5 Command Reference 5.15.8.21 serverinfo ssh ip6 Function Set the IPv6 SSH login server function Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax serverinfo ssh ip6 <mode> Options <mode> • on Enable IPv6 SSH login server function •...
Chapter 5 Command Reference 5.15.8.22 serverinfo ssh filter Function Set the application filter for the SSH server function. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax serverinfo ssh filter <count> <action> acl <acl_count> Options <count> • Filtering definition number Specify a definition number, which indicates a filtering priority, with a decimal value from 0 to 29.
Chapter 5 Command Reference 5.15.8.23 serverinfo ssh filter move Function Change the priority of the application filter for the SSH server function. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax serverinfo ssh filter move <count> <new_count> Options <count>...
XG Series User's Guide Chapter 5 Command Reference 5.15.8.25 serverinfo http Function Set the HTTP server function Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax serverinfo http ip <mode> Options <mode> • on Enable HTTP server function •...
Chapter 5 Command Reference 5.15.8.27 serverinfo http filter Function Set the application filter for HTTP server function Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax serverinfo http filter <count> <action> acl <acl_count> Options <count> • Filtering definition number Specify a definition number, which indicates a filtering priority, with a decimal value from 0 to 29.
Chapter 5 Command Reference 5.15.8.28 serverinfo http filter move Function Change the priority of the application filter for the HTTP server function Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax serverinfo http filter move <count> <new_count> Options <count>...
XG Series User's Guide Chapter 5 Command Reference 5.15.8.30 serverinfo dns Function Set the DNS server function. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax serverinfo dns ip <mode> Options <mode> • on Enable the DNS server function.
Chapter 5 Command Reference 5.15.8.32 serverinfo dns filter Function Set the application filter for the DNS server function. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax serverinfo dns filter <count> <action> acl <acl_count> Options <count> • Filtering definition number Specify a definition number, which indicates a filtering priority, with a decimal value from 0 to 29.
Chapter 5 Command Reference 5.15.8.33 serverinfo dns filter move Function Change the priority of the application filter for the DNS server function. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax serverinfo dns filter move <count> <new_count> Options <count>...
XG Series User's Guide Chapter 5 Command Reference 5.15.8.35 serverinfo sntp Function Set the SNTP server. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax serverinfo sntp ip <mode> Options <mode> • on Enable the SNTP server function.
Chapter 5 Command Reference 5.15.8.37 serverinfo sntp filter Function Set the application filter for the SNTP server function. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax serverinfo sntp filter <count> <action> acl <acl_count> Options <count> • Filtering definition number Specify a definition number, which indicates a filtering priority, with a decimal value from 0 to 29.
Chapter 5 Command Reference 5.15.8.38 serverinfo sntp filter move Function Change the priority of the application filter for the SNTP server function. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax serverinfo sntp filter move <count> <new_count> Options <count>...
XG Series User's Guide Chapter 5 Command Reference 5.15.8.40 serverinfo time ip tcp Function Set the TIME server function by TCP. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax serverinfo time ip tcp <mode> Options <mode> • on Enable the TIME server function by TCP.
XG Series User's Guide Chapter 5 Command Reference 5.15.8.42 serverinfo time ip udp Function Set the TIME server function by UDP. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax serverinfo time ip udp <mode> Options <mode> • on Enable the TIME server function by UDP.
Chapter 5 Command Reference 5.15.8.44 serverinfo time filter Function Set the application filter for the TIME server function. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax serverinfo time filter <count> <action> acl <acl_count> Options <count> • Filtering definition number Specify a definition number, which indicates a filtering priority, with a decimal value from 0 to 29.
Page 332
XG Series User's Guide Chapter 5 Command Reference Use Mode Configuration mode (admin class) Explanation Change the priority of the application filter for the TIME server function. Device Information Settings...
Chapter 5 Command Reference 5.15.8.46 serverinfo time filter default Function Set the default operation of the application filter for the TIME server function. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax serverinfo time filter default <action> Options <action>...
This section explains about the commands related to Login banner information. 5.16.1.1 login banner telnet Function Turn on or off the telnet login banner. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax login banner telnet <mode> Options <mode>...
XG Series User's Guide Chapter 5 Command Reference 5.16.1.3 login banner ssh Function Turn on or off the ssh login banner. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax login banner ssh <mode> Options <mode> Specify the desired mode.
5.17.1 Mode Operation Commands This section explains about mode operation commands. 5.17.1.1 admin Function Switch to the admin class. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax admin Options Use Mode Operation mode (user class) Explanation Switch from the user class to the admin class.
Page 337
# exit > 5.17.1.2 su Function Switch to the admin class. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax Options Use Mode Operation mode (user class) Explanation Switch from the user class to the admin class.
XG Series User's Guide Chapter 5 Command Reference 5.17.1.3 exit Function Return to the class, mode or configuration directory, or logout. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax exit Options Use Mode Operation mode (user class/admin class)
XG Series User's Guide Chapter 5 Command Reference 5.17.1.4 configure Function Switch to the configuration mode. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax configure Options Use Mode Configuration mode (admin class) Explanation Switch from the operation mode to the configuration mode.
XG Series User's Guide Chapter 5 Command Reference 5.17.1.5 end Function Return to the operation mode. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax Options Use Mode Configuration mode (admin class) Explanation Return from the configuration mode to the operation mode.
XG Series User's Guide Chapter 5 Command Reference 5.17.1.7 top Function Switch to the highest configuration directory. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax Options Use Mode Configuration mode (admin class) Explanation If the configuration directory function is enabled in the configuration mode, move up to the top directory.
Page 342
XG Series User's Guide Chapter 5 Command Reference 5.17.1.9 ! Function Return to the previous class, mode or configuration directory. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax Options Use Mode Operation mode (admin class) Configuration mode (admin class)
Terminal Operation Commands This section explains about terminal operation commands. 5.17.2.1 terminal pager Function Set the pager functions. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax terminal pager {enable|disable} Options enable Use the pager functions. disable Do not use the pager functions.
Page 344
XG Series User's Guide Chapter 5 Command Reference Key inputs Operations Skip one screen backward after specifying the number of lines for one screen *1 j ^J e ^E ^N ↓ RETURN Skip one screen forward or specified number of lines forward (show all of the skipped lines) k ^K y ^Y ^P ↑...
Page 345
XG Series User's Guide Chapter 5 Command Reference If information is displayed, the following prompt will appear. MORE(line 1-22/515 lines, 1428/33473 bytes, 4%): - -- --- ---- ----- If it cannot be displayed backward, the following prompt will appear. MORE(line 1-22 lines): - -- Description: a: Top line number on screen...
Chapter 5 Command Reference 5.17.2.2 terminal window Function Set the terminal screen size. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax terminal window [column <column>] [line <line>] Options column <column> Specify the number of digits of the terminal screen with a decimal value.
XG Series User's Guide Chapter 5 Command Reference 5.17.2.4 terminal prompt Function Set the input prompt. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax terminal prompt login "<prompt>" terminal prompt user "<prompt>" terminal prompt admin "<prompt>" Options login Set the input prompt during login.
# terminal prompt admin "\h bank/\C\w\p" 5.17.2.5 terminal timestamp Function Set the command execution date and time display function. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax terminal timestamp {enable|disable} Options enable Display the date and time when command is executed.
Chapter 5 Command Reference 5.17.2.6 terminal bell Function Set the bell function to sound in the case of an operation error. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax terminal bell {enable|disable} Options enable Sound a terminal bell in the case of an operation error.
Chapter 5 Command Reference 5.17.2.7 terminal logging Function Set the command execution history log. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax terminal logging line <line> Options line <line> Specify a number for the lines of the command execution history to be logged with a decimal value from 0 to 100.
This section explains about command execution history. 5.17.3.1 show logging command Function Display the command execution history. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show logging command [brief] [all] Options Display detailed the command execution history on the current login line.
Page 353
XG Series User's Guide Chapter 5 Command Reference Execution Example # show logging command 01/24 08:48:54 * console 0 admin show system information 01/24 08:49:02 * console 0 admin show date 01/24 08:49:11 * console 0 admin show logging commandDec 01 15:58:55 1 show system information # show logging command brief show date...
Chapter 5 Command Reference 5.17.3.2 clear logging command Function Clear the command execution history. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax clear logging command [all] Options Clear the command execution history on the current login login.
This section explains about commands related to command alias. 5.17.4.1 alias Function Set the command alias information. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax alias <alias> "<command>" Options <alias> Specify a command alias name to be assigned, with up to 80 characters.
XG Series User's Guide Chapter 5 Command Reference 5.17.4.2 show alias Function Display the command alias information. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show alias [<name>] Options Display all command alias information. <name> Display the information about the specified command alias name.
This section explains about commands related to command output operations. 5.17.5.1 more Function Display the command output one screen at a time on a display screen. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax <command> | more Options <command>...
XG Series User's Guide Chapter 5 Command Reference 5.17.5.2 tail Function Display the last part of command output. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax <command> | tail [<lines>] Options <command> Specify a command to execute.
This section explains about system operations and display commands. 5.18.1.1 show system information Function Display the system information. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show system information Options Display the system information. Use Mode...
Memory Displays the memory size installed in the device. 5.18.1.2 show system status Function Display the system status. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show system status Options Display the system status. Use Mode...
Page 361
XG Series User's Guide Chapter 5 Command Reference When a CX4 Card is installed. # show system status Current-time : Wed Dec 10 05:55:40 2008 ---(1) Startup-time : Wed Dec 10 05:52:11 2008 ---(2) restart_cause : power on ---(3) machine_state : RUNNING ---(4) power0_state...
Page 362
XG Series User's Guide Chapter 5 Command Reference inspiration_state State of environment temperature monitor. phy_state State of temperature monitor around PHY. slot1_state State of Expansion Card temperature monitor (SLOT1). NORMAL : The temperature is normal. HIGHWARNING : The device changes to a high temperature state. HIGHALARM : Thermal alarm occurs in the device.
Page 363
XG Series User's Guide Chapter 5 Command Reference restart_cause Cause for the system startup. The following system startup causes are displayed: power on : The power has been turned on. reset : The reset command has been issued. reset switch : The [RESET] switch has been pressed. system down : System-down has occurred.
Page 364
XG Series User's Guide Chapter 5 Command Reference inspiration_temp Environment temperature. phy_temp temperature around PHY. slot1_temp temperature around Expansion Card (SLOT1). At the time of three following states, "--" is displayed. The Expantion Card without Thermal Sensor is installed. (CX4) The Invalid Expantion Card is installed.
Page 365
XG Series User's Guide Chapter 5 Command Reference machine_state State of the device RUNNING : The device is active. FALLBACK : The device is into fallback state. access_direction Direction where a device is installed in. front access : The device should be installed forward. (XG0440DC) rear access : The device should be installed backward.
Page 366
XG Series User's Guide Chapter 5 Command Reference inspiration_temp Environment temperature. internal_temp Device inside temperature. XG2600 # show system status Current-time : Thu Dec 21 16:04:50 2008 ---(1) Startup-time : Thu Dec 21 16:04:36 2008 ---(2) restart_cause : power on ---(3) machine_state : RUNNING...
Page 367
XG Series User's Guide Chapter 5 Command Reference PSU1 state State of the power unit (PSU1). PSU2 state Type of the power unit (PSU2). NORMAL : The power unit works normally. NO PRESENT : The power unit is not installed. NO POWER : The power unit has been turned off.
XG Series User's Guide Chapter 5 Command Reference 5.18.1.3 show tech-support Function Display all the analysis information. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show tech-support [detail] [save] Options Display the result of the analysis. detail Display or save detail report.
XG Series User's Guide Chapter 5 Command Reference 5.18.1.9 show date Function Display the current date and time of the device. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show date Options Use Mode Operation mode (user class/admin class)
5.18.1.11rdate Function Set the date and time of the remote host into this device. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax rdate Options Set the date and time of the remote host in this device.
This section explains about commands related to configuration display. 5.19.1.1 show candidate-config Function Display the configuration being edited. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show candidate-config [all] [<config>] Options Display all configuration including default values.
Chapter 5 Command Reference 5.19.1.2 show running-config Function Display the configuration during operation. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show running-config [all] [<config>] Options Display all configuration including default values. If omitted, only the modified configuration is displayed.
XG Series User's Guide Chapter 5 Command Reference 5.19.1.4 diff Function Display the configuration difference. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax diff <src_filename> <dst_filename> Options <src_filename> Specify the name of the compare source file.
Configuration Delete Commands This section explains about commands related to configuration delete. 5.19.2.1 delete Function Delete the configuration being edited. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax delete <config> Options <config> • Configuration command Specify the name and arguments of the configuration command to be deleted.
This section explains about commands related to configuration definition information operations. 5.19.3.1 load Function Read (or load) the configuration. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax load <filename> Options <filename> Specify the name of the file to be read (or loaded).
Execution Example # load config1 5.19.3.2 save Function Save the configuration. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax save [<filename>] Options Overwrite the existing "startup-config" file with the "candidate-config" file contents. <filename> Overwrite the file specified with the "candidate-config" file contents.
XG Series User's Guide Chapter 5 Command Reference 5.19.3.3 commit Function Commit (or dynamically activate) the configuration. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax commit Options Use Mode Configuration mode (admin class) Explanation Apply the configuration that was set or changed with the configuration command, without device restart.
5.19.3.4 commit try time Function Try to commit (dynamically activate) the candidate config, or re-commit the startup-config if the try time period expires. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax commit try time <time> Options <time>...
Chapter 5 Command Reference 5.19.3.5 commit try cancel Function Cancel retrieving the startup-config after using the "commit try time" command. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax commit try cancel Options Use Mode Configuration mode (admin class) Explanation Cancel retrieving the startup-config after using the "commit try time"...
XG Series User's Guide Chapter 5 Command Reference 5.19.3.6 discard Function Discard the changes of configuration. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax discard Options Use Mode Configuration mode (admin class) Explanation Discard changes of candidate-config, and return to the same contents as for running- config.
This section explains about commands related to File Operation Commands. 5.19.4.1 dir Function Displays a list of files. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax dir [<filename>] Options <filename> Specifies the name of the file or directory to be displayed. The dir command will only display files or directories that match this parameter.
XG Series User's Guide Chapter 5 Command Reference 5.19.4.2 copy Function Copies a file. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax copy <src_filename> <dst_filename> Options <src_filename> The source file to be copied. <dst_filename> The target file name.
XG Series User's Guide Chapter 5 Command Reference 5.19.4.3 remove Function Deletes a file. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax remove <filename> Options <filename> Name of file to be deleted. Use Mode Operation mode (admin class)
This section explains the commands related to Ethernet counter, log, statistics, and status display commands. 5.20.1.1 show ether Function Display the Ethernet physical port information. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show ether [line <line>] Options Display all information.
Page 391
XG Series User's Guide Chapter 5 Command Reference Execution Example B9F# show ether line 1-7 [ETHER PORT-1] status : down ---(1) flow control ---(2) type : Normal ---(3) since : Jan 1 00:00:02 GMT 1970 ---(4) config ---(5) linkcontrol : online, recovery(-), downrelay(-) ---(6) [ETHER PORT-2] status...
Page 392
XG Series User's Guide Chapter 5 Command Reference offline (backup): Port offline by backup port function offline (icmpwatch): Port offline by ether L3 monitoring function down : Indicates that the port is in the linkdown state. auto : Indicates that automatic negotiation is enabled. 10M/100M/1000M/10G: Indicates the baud rate (10Mbps, 100Mbps, 1000Mbps or 10Gbps) of the currently linked Ethernet port.
Page 393
XG Series User's Guide Chapter 5 Command Reference Configuration Indicates setting value of "ether mode" command and "ether mdi" command. mode (setting value): Indicates the setting value of "ether mode" as mode (auto). mdi (setting value): Indicates the setting value of "ether mdi" as mdi (auto). : For the server port "-"...
XG Series User's Guide Chapter 5 Command Reference 5.20.1.2 show ether brief Function Display the information about Ethernet physical ports briefly. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show ether brief Options Display all information. Use Mode...
Page 395
XG Series User's Guide Chapter 5 Command Reference linkaggregation: Indicates that the port is used as a link aggregation port. This parameter also indicates the number of the link aggregation group that the port belongs to. "*linkaggregation" is displayed when the link aggregation port is not linked up as a multiplexed link in the linkup state.
Chapter 5 Command Reference 5.20.1.3 show ether statistics Function Display the statistics of Ethernet physical ports. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show ether statistics [line <line>] [detail] Options Display all the statistics. line <line>...
Page 397
Chapter 5 Command Reference C1 is connected with C3. C2 is connected with c4. Caution The statistics are cleared if this device is restarted. Execution Example Example of executing XG0224 #show ether statistics line 1 [ETHER PORT-1 STATISTICS] [Input Statistics] Octets...
Page 398
XG Series User's Guide Chapter 5 Command Reference Execution example when detail of XG0224 (Giga port) is specified # show ether statistics line 1 detail [ETHER PORT-1 STATISTICS] [Input Statistics] Octets bits/sec Frames frames/sec Unicast frames/sec Multicast frames/sec Broadcast frames/sec...
Page 399
---(64) 512-1023 ---(65) 1024-1518 ---(66) 1519-2047 ---(67) 2048-4095 ---(68) 4096-9216 ---(69) Execution example when detail of XG0224 (10Giga port) is specified # show ether statistics line 26 detail [ETHER PORT-26 STATISTICS] [Input Statistics] Octets bits/sec Frames frames/sec Unicast frames/sec Multicast...
Page 402
XG Series User's Guide Chapter 5 Command Reference Example of executing internal connection port of XG0448 XG0448(config)# show ether statistics line c1 [INTERNAL CONNECTION PORT-1 STATISTICS] Packets from : line 1 to 24 ---(40) : line 51 to 52 ---(41) Connected to : C3 [Input Statistics]...
Page 403
XG Series User's Guide Chapter 5 Command Reference Execution example when detail of XG0448 (Giga port) is specified # show ether statistics line 1 detail [ETHER PORT-1 STATISTICS] [Input Statistics] Octets bits/sec Frames frames/sec Unicast frames/sec Multicast frames/sec Broadcast frames/sec Pause frames Mac Control frames Discards...
Page 404
XG Series User's Guide Chapter 5 Command Reference (Continued) [Input Detail Statistics] Frame size frames frames/sec 65-127 128-255 256-511 512-1023 1024-1518 1519-2047 2048-4095 4096-9216 [Output Detail Statistics] Frame size frames frames/sec 65-127 128-255 256-511 512-1023 1024-1518 1519-2047 2048-4095 4096-9216 Execution example when detail of XG0448 (10Giga port) is specified # show ether statistics line 50 detail [ETHER PORT-50 STATISTICS] [Input Statistics]...
Page 406
XG Series User's Guide Chapter 5 Command Reference Number of broadcast frames received per second (Frames/sec.) Number of received PAUSE frames (MAC control frames) Number of discarded frames out of all the received frames Number of received shortsized frames (less than 64 bytes) Number of frames in which FCS error is detected in 64 data size bytes or more Number of received frames in which an alignment error was detected Number of shortsized frames (less than 64 bytes) in which an FCS or alignment...
Page 407
XG Series User's Guide Chapter 5 Command Reference The following information is displayed only for an internal connected port of XG0448 External port in which it belongs to internal, connected port Opposed internal, connected port. The counter of an internal, connected port becomes a frame that has been forwarded from the Giga/10Giga port with the value to which the header for an internal control in 12 bytes is added.
Page 408
XG Series User's Guide Chapter 5 Command Reference Number of frames (with data size of 4096 to 9216 bytes) received and number of frame (with data size of 4096 to 9216 bytes) received per second (Frames/sec.) Number of frames (with 64 byte data size) sent and number of frame (with 64 byte data size) sent per second (Frames/sec.) Number of frames (with data size of 65 to 127 bytes) sent and number of frame (with data size of 65 to 127 bytes) sent per second (Frames/sec.)
Page 410
XG Series User's Guide Chapter 5 Command Reference Example of executing internal connection port of XG0440DC / XG0440DCR XG0440DCR(config)# show ether statistics line c1 [INTERNAL CONNECTION PORT-1 STATISTICS] ---(40) Packets from : line 1 to 24 ---(41) : line 43 to 44 Connected to : C3 ---(42)
Page 411
XG Series User's Guide Chapter 5 Command Reference Number of received broadcast frames Number of broadcast frames received per second (Frames/sec.) Number of received PAUSE frames (MAC control frames) Number of discarded frames out of all the received frames Number of received shortsized frames (less than 64 bytes) Number of frames in which FCS error is detected in 64 data size bytes or more Number of received frames in which an alignment error was detected Number of shortsized frames (less than 64 bytes) in which an FCS or alignment...
Page 412
XG Series User's Guide Chapter 5 Command Reference The following information is displayed only for an internal connected port of XG0440DC / XG0440DCR Statistics of Internal connection port External port in which it belongs to internal, connected port Opposed internal, connected port. The counter of an internal, connected port becomes a frame that has been forwarded from the Giga/10Giga port with the value to which the header for an internal control in 12 bytes is added.
Page 415
XG Series User's Guide Chapter 5 Command Reference Number of received MAC control frames Number of received frames discarded because of insufficient resources or backpressure Number of received frames that were discarded by filtering Number of received frames that were discarded by the reception discard setting Number of received frames that were discarded because the STP was not in the transmitting state The number of frames discarded because they were not associated with the VLAN...
Page 416
XG Series User's Guide Chapter 5 Command Reference Number of frames sent with a data size of 65 to 127 bytes, and the number of those frames sent per second (frames/sec) Number of frames sent with a data size of 128 to 255 bytes, and the number of those frames sent per second (frames/sec) Number of frames sent with a data size of 256 to 511 bytes, and the number of those frames sent per second (frames/sec)
Page 417
XG Series User's Guide Chapter 5 Command Reference Example of executing 10Giga port of XG2600 # show ether statistics line 1 [ETHER PORT-1 STATISTICS] [Input Statistics] Octets : 1493377360 ---(1) bits/sec ---(2) Frames : 6706618 ---(3) frames/sec ---(4) Unicast : 6704279 ---(5) frames/sec ---(6)
Page 418
XG Series User's Guide Chapter 5 Command Reference Example of executing m1 port of XG2600 (management port) # show ether statistics line m1 [ETHER PORT-1 STATISTICS] [Input Statistics] Octets : 148231 bits/sec : 511 Frames : 897 frames/sec Unicast : 45 frames/sec Multicast : 852...
Page 419
XG Series User's Guide Chapter 5 Command Reference Number of received PAUSE frames (MAC control frames) Number of discarded frames out of all the received frames Number of received shortsized frames (less than 64 bytes) Number of frames in which FCS error is detected in 64 data size bytes or more Number of received frames in which an alignment error was detected Number of shortsized frames (less than 64 bytes) in which an FCS or alignment error was detected...
Page 420
XG Series User's Guide Chapter 5 Command Reference Number of FCS error frame transmissions of 64 data size bytes or more The number of frames in which the error detection is done to the "cut-through" mode in the reception port after it begins to transmit and the transmission discontinuance is done is contained.
Page 421
XG Series User's Guide Chapter 5 Command Reference Execution example when detail of XG2600 (10Giga port) is specified # show ether statistics line 1 detail [ETHER PORT-1 STATISTICS] [Input Statistics] Octets : 1493377360 bits/sec Frames : 6706618 frames/sec Unicast : 6704279 frames/sec Multicast : 15...
Page 422
XG Series User's Guide Chapter 5 Command Reference Number of frame sending and receiving of (with data size of 65 to 127 bytes) data size bytes. And, it is numerical of the frame sending and receiving of (with data size of 65 to 127 bytes) size of data a second bytes. (frames/sec) Number of frame sending and receiving of (with data size of 128 to 255 bytes) data size bytes.
5.20.1.4 show ether media-info Function Display Media information of Ethernet physical port Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show ether media-info [line <line>] Options Display the information of all SFP+,CX4 ports and SFP ports line <line>...
Page 424
SFP (1000BASE-BX-D) module is installed SFP(BX-U) SFP (1000BASE-BX-U) module is installed SFP(ZX) SFP (1000BASE-ZX) module is installed The CX4 expansion card is mounted. (Only for XG0448 / XG0224. ) SFP+(SR) SFP+(10GBASE-SR) module is installed SFP+(LR) SFP+(10GBASE-LR) module is installed UNKNOWN Type of the installed module is unknown...
5.20.1.5 show ether utilization Function Display the usage ratio (or utilization) information of Ethernet physical ports. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show ether utilization Options Display the utilization information of all Ethernet ports.
Page 426
XG Series User's Guide Chapter 5 Command Reference Execution Example (XG0448) # show ether utilization Port TX/sec Util RX/sec Util ------ ---------- ------- ---------- ------- Execution Example (XG0440DC / XG0440DCR) # show ether utilization Port TX/sec Util RX/sec Util ------ ---------- ------- ----------...
Page 427
XG Series User's Guide Chapter 5 Command Reference Execution Example (XG2600) # show ether utilization Port TX/sec Util RX/sec Util ------ ---------- ------- ---------- ------- 710227 1420457 1420454 Port : Ethernet physical port number The management port is displayed with M1. (Only XG2600) An "internal connected port"...
5.20.1.6 show ether queue Function Display the number of packets placed in the COS queue of Ethernet physical ports. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show ether queue [line <line>] Options Display the number of packets placed in the COS queue of all ports.
Page 429
XG Series User's Guide Chapter 5 Command Reference Execution Example Execution Example # show ether queue [ETHER PORT-1] CoS Queue 0 ---(1) CoS Queue 1 CoS Queue 2 : 238 CoS Queue 3 CoS Queue 4 CoS Queue 5 CoS Queue 6 CoS Queue 7 [ETHER PORT-2] CoS Queue 0...
5.20.2.1 clear ether statistics Function Clear the statistics of Ethernet physical ports. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax clear ether statistics [line <line>] Options Clear all the statistics. line <line>...
XG Series User's Guide Chapter 5 Command Reference 5.21 USB connection Counter, Log, Statistics, and Status Display and Clear Operation Commands This section explains about USB connection Counter, Log, Statistics, and Status Display and Clear Operation Commands. 5.21.1 USB connection Counter, Log, and Statistics Clear Commands This section explains commands related to USB connection Counter, Log, and Statistics Clear Commands.
Page 433
XG Series User's Guide Chapter 5 Command Reference USB device controller status Status is displayed via the following messages: Uninit: not initialized Initializing [1/2] (Set configuration) Initializing [2/2] (Get max lun) Get device specs [1/5] (Test unit ready) Get device specs [2/5] (Inquiry) Get device specs [3/5] (Mode sense) Get device specs [4/5] (Read capacity) Get device specs [5/5] (Read format capacities)
Page 434
XG Series User's Guide Chapter 5 Command Reference Request sense code When an error is detected by the USB device the error data established on the USB device is displayed. Vendor Vendor information for the USB device is displayed. Product Product information for the USB device is displayed.
This section explains the commands related to LACP counter, log, statistics, and status display commands. 5.22.1.1 show lacp Function Display LACP information briefly. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show lacp Options Display all information.
Page 436
XG Series User's Guide Chapter 5 Command Reference Port number Indicates that the information display at the right side is for this device (Actor) or the remote device (Partner). Indicates that the LACP mode is active or passive. The passive is displayed if the valid LACP remote system information has not been obtained.
XG Series User's Guide Chapter 5 Command Reference 5.22.1.2 show lacp statistics Function Display the LACP statistics. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show lacp statistics Options Display all statistics. Use Mode Operation mode (user class/admin class)
This section explains the commands related to LACP counter, log, statistics, and status clear commands. 5.22.2.1 clear lacp statistics Function Clear the LACP statistics. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax clear lacp statistics Options Use Mode...
XG Series User's Guide Chapter 5 Command Reference 5.23 M1 port Status Display command This section explains the commands related to oob. 5.23.1 M1 port Status Display command This section explains the commands related to M1 port Status Display command. 5.23.1.1 show oob Function Display of M1 port information...
This section explains the commands related to interface counter, log, statistics, and status display commands. 5.24.1.1 show interface Function Display the interface information. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show interface [interface <interface_name>] Options Display the status and type of all interfaces.
Page 441
XG Series User's Guide Chapter 5 Command Reference Interface name MTU size Interface flag The interface flag is displayed by any of the following character strings. : Operating. BROADCAST: An available broadcast address is being established. LOOPBACK : Loopback. POINTOPOINT: Point-to-point link.
XG Series User's Guide Chapter 5 Command Reference 5.24.1.2 show interface brief Function Display the interface information. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax Display interface information briefly. Options Display all interfaces briefly. interface <interface_name>...
Chapter 5 Command Reference 5.24.1.3 show interface summary Function Display the number of interface entries (the interface summary). Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show interface summary Options Use Mode Operation mode (user class/admin class)
This section explains the commands related to ARP entry. 5.25.1.1 show arp Function Display the ARP entries. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show arp [<ip_address>] show arp summary Options Display the details of all ARP entries.
Page 445
XG Series User's Guide Chapter 5 Command Reference An entry type is displayed. The details are as follows. P: A permanent entry Rest The time to live of the ARP entry is indicated in seconds. For the permanent entry, "perm" is shown. Interface The ARP entry interface is displayed.
ARP Entry Clear Commands This section explains the commands related to ARP entry clear. 5.25.2.1 clear arp Function Clear the ARP entries. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax clear arp [<ip_address>] Options Clear all ARP entries. <ip_address>...
This section explains the commands related to the IPv4 routing table counter, log, statistics, and status display commands. 5.26.1.1 show ip route Function Display the routing table information. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show ip route [all] show ip route connected [all] show ip route static [all] show ip route destination <ip_address>/<mask>...
Page 448
XG Series User's Guide Chapter 5 Command Reference Execution Example Display of the entire route information # show ip route all Destination/Mask Gateway Distance UpTime Interface --- --------------- -------------- -------- -------- --------- 192.168.10.0/24 192.168.10.50 00:00:01 lan0 192.168.11.0/24 192.168.10.20 00:00:01 lan0 The kernel flag and the protocol type are displayed.
5.26.1.2 show ip route summary Function Display the number of routing table information entries. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show ip route summary [all] Options Display the number of route information sets that have been registered on the routing table.
5.26.1.3 show ip route kernel Function Display the routing table of the IP kernel. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show ip route kernel show ip route kernel longest-match <ip_address> show ip route kernel summary Options Display the current entries on the routing table of the IP kernel.
Page 451
XG Series User's Guide Chapter 5 Command Reference Flag : The entry type is displayed. The details are as follows. U (Up): Indicates that the route is enabled. G (Gateway): Indicates the route which requires an intermediate routing such as gateway. H (Host): Indicates the host entry.
This section explains the commands related to IPv6 routing table. 5.26.2.1 show ipv6 route Function Display IPv6 routing table information Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show ipv6 route [all] show ipv6 route connected [all] show ipv6 route static [all] show ipv6 route ra [all] show ipv6 route destination <prefix>/<prefixlen>...
Page 453
XG Series User's Guide Chapter 5 Command Reference The kernel flag and the protocol type are displayed. The following shows the kernel flags that may be displayed. : Indicates the route registered in the IPv6 kernel. Blank : Indicates the route not registered in the IPv6 kernel. The following shows the protocol types that may be displayed.
5.26.2.2 show ipv6 route summary Function Display number of routes registered in IPv6 routing table Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show ipv6 route summary [all] Options Display number of routes registered in IPv6 routing table...
Chapter 5 Command Reference 5.26.2.3 show ipv6 route kernel Function Display routing table of IPv6 kernel Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show ipv6 route kernel show ipv6 route kernel summary Options Display the current entry of IPv6 kernel routing table longest-match <ipv6_address>...
Page 456
XG Series User's Guide Chapter 5 Command Reference Destination/Masklen The destination network address and the mask value are displayed. If routed via the host, no mask value is displayed. Gateway: The gateway address is displayed. The direct route indicates the MAC address of the gateway. If the gateway address is not resolved, link#x is shown (where, x is an interface index number that the system automatically assigns to each interface).
XG Series User's Guide Chapter 5 Command Reference 5.26.2.4 show ipv6 ra default-router-list Function Display default router list Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show ipv6 ra default-router-list Options Display default router list Use Mode...
XG Series User's Guide Chapter 5 Command Reference 5.26.2.5 show ipv6 ra prefix-list Function Display prefix list Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show ipv6 ra prefix-list Options Display prefix list Use Mode Operation mode (user class/admin class)
5.27.1.1 show ip traffic Function Display the IP-related statistics. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show ip traffic show ip traffic { tcp | udp | ip | icmp | igmp | pim } Options Display all IP statistics.
Page 460
XG Series User's Guide Chapter 5 Command Reference Execution Example # show ip traffic tcp: 170 packets sent 145 data packets (29694 bytes) 1 data packet (18 bytes) retransmitted 0 resends initiated by MTU discovery 19 ack-only packets (10 delayed) 0 URG only packets 0 window probe packets 0 window update packets...
Page 461
XG Series User's Guide Chapter 5 Command Reference (continued) 26 datagrams output 467 total packets received 0 bad header checksums 0 with size smaller than minimum 0 with data size < data length 0 with ip length > max ip packet size 0 with header length <...
This section explains the commands related to IPv4 packet statistics clearing. 5.27.2.1 clear ip traffic Function Clear the IP-related statistics. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax clear ip traffic Options Clear the IP-related statistics.
This section explains the commands related to IPv6 packet statistics display. 5.27.3.1 show ipv6 traffic Function Display IPv6 packets statistics information Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show ipv6 traffic show ipv6 traffic { tcp | udp | ip | icmp } Options...
This section explains the commands related to IPv6 packet statistics clearing. 5.27.4.1 clear ipv6 traffic Function Clear IPv6 packet statistics information Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax clear ipv6 traffic Options Clear all IPv6 statistics information...
This section explains the commands related to bridge counter, log, statistics, and status display. 5.28.1.1 show bridge Function Display the learning table status and statistics. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show bridge show bridge summary Options Display the contents of the learning table.
Page 468
XG Series User's Guide Chapter 5 Command Reference Status of learning table One of the following is displayed. : Dynamic learning table : Static learning table Display of learning table assignment #show bridge summary Registered station blocks : --- (1) Dynamic entry --- (2) Static entry...
5.28.2.1 clear bridge Function Initialize the dynamically learned MAC address from the learning table. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax clear bridge clear bridge port <portlist> clear bridge mac <macaddr> <vid>...
This section explains the commands related to spanning tree counter, log, statistics, and status display. 5.28.3.1 show spanning-tree Function Display the spanning tree information. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show spanning-tree show spanning-tree root show spanning-tree bridge show spanning-tree active show spanning-tree interface <interface_name>...
Page 471
XG Series User's Guide Chapter 5 Command Reference Execution Example Display of all spanning tree information in a simple format # show spanning-tree Spanning tree enabled protocol IEEE Root ID Priority 32768 ---(1) Address 00:00:e2:08:57:89 ---(2) Cost 200000 ---(3) Port 1 (eth1) ---(4) Hello Time 2 sec...
Page 472
XG Series User's Guide Chapter 5 Command Reference Configuration BPDU send interval The configuration BPDU send interval (in seconds) is displayed. Maximum wait time The maximum wait time (in seconds) of configuration BPDUs is displayed. Maximum forwarding delay time The maximum forwarding delay time (in seconds) is displayed. BPDU forwarding function The BPDU forwarding function (on or off) defined on this device is displayed.
Page 473
XG Series User's Guide Chapter 5 Command Reference Display of spanning tree information of the root bridge # show spanning-tree root Root ID Priority 32768 ---(1) Address 00:00:e2:08:57:89 ---(2) Cost 200000 ---(3) Port 1 (eth1) ---(4) Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec ----------------...
Page 474
XG Series User's Guide Chapter 5 Command Reference BPDU forwarding function The BPDU forwarding function (on or off) defined on this device is displayed. STP operation mode The STP operation mode (disable/stp/rstp/mstp) of this device is displayed. Display of only spanning tree information of the active interface # show spanning-tree interface active eth1 is Forwarding Port Version 0(STP)
Page 475
XG Series User's Guide Chapter 5 Command Reference (Continued) BPDU statistics: Config BPDU: sent 292, sent error 0 --------- ------------ (13) (14) received 0, discarded 0 ----------- ----------- (15) (16) TCN BPDU: sent 0, sent error 0 ------ ------------ (17) (18) received 0, discarded 0 ----------...
Page 476
XG Series User's Guide Chapter 5 Command Reference Designated bridge priority The priority of the designated bridge is displayed. MAC address of designated bridge The MAC address of the designated bridge is displayed. Designated port ID The designated port ID (the port priority and port number) is displayed. Designated port path cost The path cost of the designated port is displayed.
Page 477
XG Series User's Guide Chapter 5 Command Reference Display of spanning tree information of the specified interface # show spanning-tree interface 1 eth1 is Forwarding Port Version 0(STP) ------------------ ------------------- Port path cost 200000(auto), Port priority 128, Port Identifier 128.1 --------------------------- ----------------- ----------------------...
Page 478
XG Series User's Guide Chapter 5 Command Reference Port role One of the following is displayed for the port role. Disabled : The STP is disabled. Root : Root port Designated : Designated port Blocking : Blocking port Alternate : Alternate port (It is displayed only when RSTP or MSTP is active.) Backup : Backup port (It is displayed only when RSTP or MSTP is active.) Priority of root bridge...
Page 479
XG Series User's Guide Chapter 5 Command Reference To display all spanning tree information in detail # show spanning-tree detail IEEE compatible spanning tree protocol is being executed. Bridge Identifier has priority 32768, address 00:0b:5d:89:00:aa ------------------------------------ ------------------------- Configured hello time 2, max age 20, forward delay 15 ----------------------- ---------- ----------------...
Page 480
XG Series User's Guide Chapter 5 Command Reference (Continued) Other statistics: changed to forwarding state 1 (37) eth2 is Forwarding Port Version 0(STP) STP-Compatible(-) ------------------ ------------------- ----------------- (10) (11) (36) Port path cost 200000(auto), Port priority 128, Port Identifier 128.2 --------------------------- ----------------- ----------------------...
Page 481
XG Series User's Guide Chapter 5 Command Reference Root port The interface name of the root port is displayed. If this device operates as the root bridge, the root port (Item (8)) and root path cost (Item (9)) are not displayed. Only the following message is displayed. This bridge is the root Root path cost The path cost to the root bridge is displayed.
Page 482
XG Series User's Guide Chapter 5 Command Reference Designated port path cost The path cost of the designated port is displayed. Number of configuration BPDU send times The number of configuration BPDU send times is displayed. Number of configuration BPDU send error times The number of configuration BPDU send error times is displayed.
Chapter 5 Command Reference 5.28.3.2 show spanning-tree instance Function Display the spanning tree information. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show spanning-tree instance <instance_id> [detail] Options <instance_id> Display the spanning tree information of the specified instance only.
Page 484
XG Series User's Guide Chapter 5 Command Reference (Continued) Interface Port ID Cost Status(Role) Sent Designated Bridge ID Received --------------- -------- ----------- ----------------------- ---------- eth1 128.1 20000* Forwarding(Root) ---- ----- ------- ----------------- (21) (22) (23) (24) (25) 128.1 0 00:00:e2:08:57:89 ----- ---- -----------------------...
Page 485
XG Series User's Guide Chapter 5 Command Reference Maximum wait time (in seconds) The maximum wait time (in seconds) of configuration BPDUs is displayed. Maximum forwarding delay time (in seconds) The maximum forwarding delay time (in seconds) is displayed. Remaining hop count from root bridge The remaining hop count from the root bridge is displayed.
Page 486
XG Series User's Guide Chapter 5 Command Reference Number of BPDU send times The number of BPDU send times (the total value of all BPDU types) is displayed. Port ID of designated bridge The port ID of the designated bridge is displayed. Designated path cost of configuration BPDU The designated path cost of the configuration BPDU is displayed.
Page 487
XG Series User's Guide Chapter 5 Command Reference Disabled : The STP is disabled. Discarding : The port is in the discarding state (it is displayed only when RSTP or MSTP is active). Blocking : The port is in the blocking state. Listening : The port is in the listening state.
Page 488
XG Series User's Guide Chapter 5 Command Reference Display of detailed spanning tree information of instance 0 # show spanning-tree instance 0 detail MSTP Configuration Information Region Name : region1 Revision Level : 0 Instance ID 1 Vlans 20-30 Root ID Priority 32768 Address...
Page 489
XG Series User's Guide Chapter 5 Command Reference (Continued) BPDU statistics: Config BPDU: sent 141, sent error 0 -------- ------------ (16) (17) received 138, discarded 1 ------------ ----------- (18) (19) TCN BPDU: sent 0, sent error 0 ------ ------------ (20) (21) received 0, discarded 0 ----------...
Page 490
XG Series User's Guide Chapter 5 Command Reference Port role One of the following is displayed for the port role. Disabled : The STP is disabled. Root : Root port Designated : Designated port Blocking : Blocking port Alternate : Master port Backup : Backup port Priority of root bridge...
Page 491
XG Series User's Guide Chapter 5 Command Reference Number of TCN BPDU send times The number of TCN BPDU send times is displayed. Number of TCN BPDU send error times The number of TCN BPDU send error times is displayed. Number of TCN BPDU receive times The number of TCN BPDU receive times is displayed.
Page 492
XG Series User's Guide Chapter 5 Command Reference Display of detailed spanning tree information of the specified instance other than instance 0 # show spanning-tree instance 1 detail MSTP Configuration Information Region Name : region1 Revision Level : 0 Instance ID 1 Vlans 120-130 Root ID Priority...
Page 493
XG Series User's Guide Chapter 5 Command Reference Interface name and port status of the specified instance One of the following is displayed for the port status of the specified instance. Disabled : The STP is disabled. Discarding : The port is in the discarding state (it is displayed only when RSTP or MSTP is active).
Page 494
XG Series User's Guide Chapter 5 Command Reference Port processing type of the specified instance One of the following is displayed for the port processing type to be set by the sent or received BPDU. Disabled : Disabled port Aged : The MSTP BPDU receive timeout detection port Mine : MSTP BPDU packets sending port considered having high port...
This section explains the commands related to spanning tree counter, log, statistics, and status clearing. 5.28.4.1 clear spanning-tree statistics Function Clear the statistics relating to the spanning tree. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax clear spanning-tree statistics Options Use Mode...
This section explains about commands related to LLDP Counter, Log, Statistics, and Status Display Commands. 5.29.1.1 show lldp Function Display LLDP Information Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show lldp [port <portlist>] [detail] Options Disokay all LLDP information of the ports which LLDP function is enabled on port <portlist>...
Page 497
XG Series User's Guide Chapter 5 Command Reference Execution Example # show lldp Send Interval Time : 30 seconds ---(1) Send Hold Count : 4 times ---(2) Send Delay : 2 seconds ---(3) Reinit Delay : 2 seconds ---(4) Notification Interval Time : 5 seconds ---(5) Port...
Page 498
XG Series User's Guide Chapter 5 Command Reference (Continued) [PORT 8] Configuration Mode : send Send LLDPDU size : 179 octets Chassis ID : subtype=4(MAC) info=00:0b:5d:fd:05:b2ц Port ID : subtype=5(ifName) info="8" Time To Live(TTL) : 120 seconds Port Description : info="EthernetPort(ether8)" System Description : info="'SBAX2' '1.2 V01.00' 'Wed Feb 13 15:23:07 JST 2008'"...
Page 499
XG Series User's Guide Chapter 5 Command Reference LLDP send information Setting value by lldp info command : Send Port Description TLV : Send System Name TLV : Send System Description TLV : Send System Capabilities TLV : Send Management Address TLV : disable IEEE802.1 LLDP send information : Port VLAN ID...
Page 500
XG Series User's Guide Chapter 5 Command Reference System Capabilities information Value which is sent with System Capabilities TLV info= : Available function enabled= : Enabled function Bridge : Bridge functon Router : Router function When system-description is disabled by lldp info command, this value is not displayed.
Page 501
XG Series User's Guide Chapter 5 Command Reference Maximum Frame length Size Value which is sent with IEEE802.3 Maximum Frame Size TLV When maximum-frame-size is disabled by lldp info command, this value is not displayed. SNMP Notification Trap SNMP Notification Trap setting Number of ports which LLDP function is enabled in When port option is not specified, Number of port which LLDP function is enabled...
XG Series User's Guide Chapter 5 Command Reference 5.29.1.2 show lldp summary Function Display LLDP summary information Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show lldp summary Options Use Mode Operation mode (user class/admin class)
Page 503
XG Series User's Guide Chapter 5 Command Reference Execution Example # show lldp neighbors Port Neighbor Counts ---- --------------- # show lldp neighbors port 1-2 detail [PORT 1] ---(1) Neighbor Counts : 1 ---(2) Neighbor 1 ---(3) Chassis ID : subtype=4(MAC) info=02:00:0e:d1:47:80 ---(4) Port ID : subtype=5(ifName) info="MB/0"...
Page 504
XG Series User's Guide Chapter 5 Command Reference Port description information Value which is sent with Port Description TLV System name information Value which is received with System Name TLV System description information Value which is received with System Description TLV System Capabilities information Value which is received with System Capabilities TLV info=...
5.29.1.4 show lldp statistics Function Display LLDP statistics information Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show lldp statistics [port <portlist>] [detail] Options Display LLDP statistics information of all ports which LLDP function is enabled in port <portlist>...
Page 506
XG Series User's Guide Chapter 5 Command Reference # show lldp statistics detail [Neighbor tables statistics] Last changed time : Wed Feb 13 16:09:01 2008 ---(1) Tables inserts ---(2) Tables deletes ---(3) Tables drops ---(4) Tables ageouts ---(5) [PORT 1] ---(6) Sent packets ---(7) Received packets...
This section explains about commands related to LLDP Counter, Log, Statistics, and Status Clear Commands. 5.29.2.1 clear lldp neighbors Function Clear LLDP neighbor information Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax clear lldp neighbors Options Use Mode...
This section explains the commands related to VLAN counter, log, statistics, and status display. 5.30.1.1 show vlan Function Display the VLAN setting Information. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show vlan show vlan summary show vlan interface show vlan vid <vlan_id>...
Page 509
XG Series User's Guide Chapter 5 Command Reference Execution Example # show vlan Interface Type Description ---- ---------------- ------------ -------- ----------------------- ether5 untagged port default ether6 untagged ether7 dot1q-tagged port linkaggregation1 dot1q-tagged ether8 untagged port v100 ether13 untagged protocol v200 ether14 untagged ether15...
Number of entries of each VLAN type, and total number of VLAN entries 5.30.1.2 show vlan brief Function Display the VLAN setting Information briefly. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show vlan brief Options Use Mode...
This section explains commands related to COS queue counter, log, statistics, and status display. 5.31.1.1 show qos cosmap Function Display the correspondence between the COS value and storage queue for a packet. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR Syntax show qos cosmap Options Use Mode...
XG Series User's Guide Chapter 5 Command Reference 5.31.1.2 show qos prioritymap Function Display the correspondence between the COS value and storage queue for a packet. Available Model XG2600 Syntax show qos prioritymap [line <line>] Options Display the relationship between packet COS values and their storage queues of all ports.
5.32.1.1 show ssh server key Function Display the public key for SSH host authentication. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show ssh server key {dsa|rsa} Options Display the DSA public key for SSH host authentication of this device.
Page 514
XG Series User's Guide Chapter 5 Command Reference Execution Example Display of the DSA public key # show ssh server key dsa ssh-dss AzaCJB5CpVUXI1LXjzNVo1kt/LHGhWlOleJQDj11tGeeAAAFKoNjMatP i8JWtZhrgldtxVVmBAIAB3Nc3MAAAAAkgFa0nu7HMPdQAAAIA4sIwVzNfTpxNtjJ Qx1gJHrDjybKeBMmpnJ/RtGTJfvZW5T/aDc/aoB7PdF+appeXx9U8FsQF+EaMNfq P3lK2u3XAEoAzLa0JQCo6VjoDQh15YIzKFo2AVaK4lCeS3q81q8A4+jttJ0Dt0U0 rVucQoOq+BdIgaCMDuaqmJQAotGvZvZQ/RMTSh6pMh+z9DdB1DLnPNxEyt61Sftz Vk+rjgZ29In2V7ai4yuOfIhNL61ybOrrfoZ9YQW4P9rJuDxhvn2xvZQ/RMTSh6pM 6WIwA9mlzAst/YBxbb9JcO7uPVhN8M624q8yKsQaMClW1AAAWOO+ZkaqccWLy9GU xPksjfC+N7O22akmykT8V6iMh4+7iAIBJYE6pWpsQU5nFP9rJuDx5R/QV4Ql77od 96vNtgwv/hSseRFjyqrGxKewMb11FNjzWSAUyzW0p+GLR/mqBCFavMRl4toxEsP3 UDNRpGpFdw== root@localhost --- (1) The DSA public key for host authentication of this device Display of the RSA public key # show ssh server key rsa ssh-rsa AA94UAATdVfYAAxsAArx3AAIF7QAsTsTwAEeKogAFAlNoAA0OAAAAj3F...
This section explains commands related to IGMP snooping counter, log, statistics, and status display. 5.33.1.1 show igmpsnoop brief Function Display the brief information on IGMP snooping. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show igmpsnoop brief Options Display the number of groups held by IGMP snooping.
Chapter 5 Command Reference 5.33.1.2 show igmpsnoop mrouter Function Display the multicast router port information. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show igmpsnoop mrouter [<vidlist>] Options Display information about all VLANs with the valid IGMP snooping.
Chapter 5 Command Reference 5.33.1.3 show igmpsnoop reporter Function Display the multicast listener information. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show igmpsnoop reporter [<vidlist>] Options Display information about all VLANs with the valid IGMP snooping.
Chapter 5 Command Reference 5.33.1.4 show igmpsnoop statistics Function Display the IGMP snooping statistics. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show igmpsnoop statistics [<vidlist>] Options Display information about all VLANs with the valid IGMP snooping.
Page 519
XG Series User's Guide Chapter 5 Command Reference Number of received IGMP Leave packets Number of registration times of group address entries Number of deletion times of group address entries Number of header received checksum error packets of IGMP packet Number of received packet-format error packets, except for checksum errors Number of unsuccessful registration times due to an excess of the upper limit on the number of entries...
This section explains commands related to IGMP snooping counter, log, statistics, and status clear. 5.33.2.1 clear igmpsnoop statistics Function Clear the IGMP snooping statistics. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax clear igmpsnoop statistics [<vidlist>] Options Clear the statistics of all VLANs with the valid IGMP snooping.
Chapter 5 Command Reference 5.33.2.2 clear igmpsnoop group Function Clear the IGMP snooping entries. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax clear igmpsnoop group <vid> <address> Options <vid> Specify an ID of VLAN with the entries to clear. If "all" is specified, all VLANs are selected.
Loopdetection Counter, Log, Statistics, and Status Display Commands 5.34.1.1 show loopdetect Function Displays loop detection status. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show loopdetect Options Use Mode Operation mode (user class/admin class) Configuration mode (admin class) Explanation Displays loop detection status.
Page 523
XG Series User's Guide Chapter 5 Command Reference Loop detection status undetected : Loop has not been detected. detected : Loop has been detected (the loop detection frame sent by this port has been received by a port on this device). *If the port has been disabled, "(portdisable)"...
5.35.1.1 show aaa radius client server-info Function Display the RADIUS server information. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show aaa radius client server-info [group <group_id>] Options Display all server information of the AAA group.
This section explains commands related to NETTIME (time/sntp) statistics information display. 5.36.1.1 show nettime status Function Display the status with the NETTIME (time/sntp) function. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show nettime status Options Use Mode...
Chapter 5 Command Reference 5.36.1.2 show nettime statistics Function Display the statistics with the NETTIME (time/sntp) function. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show nettime statistics [<mode> [<protocol>]] Options Display all the currently operating device information.
Page 527
XG Series User's Guide Chapter 5 Command Reference No option If options are omitted, all NETTIME information running on this device is displayed. # show nettime statistics NETTIME server statistics information: [sntp udp] 0 received synchronized request --- (1) received invalid packet --- (2) 0 request discard (clock not synchronized) --- (3)
Page 528
XG Series User's Guide Chapter 5 Command Reference • server Total number of received synchronized request packets Total number of invalid packets among the synchronized request packets of Item Total number of discarded synchronized request packets due to the out of synchronized status of this device Total number of unsuccessful response transmission packets Total number of response transmission packets...
This section explains commands related to NETTIME (time/sntp) statistics information display. 5.36.2.1 clear nettime statistics Function Clear the NETTIME (time/sntp) statistics. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax clear nettime statistics [<mode>] Options Clear all NETTIME (time/sntp) statistics.
This section explains commands related to proxyDNS statistics information display. 5.37.1.1 show proxydns statistics Function Display the statistics with Proxy DNS function. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show proxydns statistics Options Use Mode...
Page 531
XG Series User's Guide Chapter 5 Command Reference Number of packets discarded by the URL filtering function Number of packets discarded due to insufficient header length ProxyDNS Statistics Display and Clear Operation Commands...
This section explains commands related to proxyDNS statistics information clear. 5.37.2.1 clear proxydns statistics Function Clear the ProxyDNS statistics. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax clear proxydns statistics Options Use Mode Operation mode (admin class)
This section explains commands related to the SNMP statistic information display. 5.38.1.1 show snmp statistics Function Display the statistics with SNMP function. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show snmp statistics Options Use Mode...
Page 534
XG Series User's Guide Chapter 5 Command Reference Total number of SNMP received messages Total number of SNMP sent messages Total number of unsupported SNMP received messages Total number of SNMP received messages of the unused community Total number of received messages that indicate the operations not allowed in the community Total number of received messages with ASN.1 errors Total number of receive PDU packets with the tooBig error status...
Page 535
XG Series User's Guide Chapter 5 Command Reference Total number of received invalid EngineIds Total number of received authorization failures Total number of received encryption failures SNMP Statistics Display and Clear Operation Commands...
This section explains commands related to the SNMP statistic clearing. 5.38.2.1 clear snmp statistics Function Clear the SNMP statistics. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax clear snmp statistics Options Use Mode Operation mode (admin class)
This section explains about commands related to Ethernet L3 monitor function counter, log, statistics, and status display. 5.39.1.1 show icmpwatch Function Display various information collected by the Ethernet L3 monitor function. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show icmpwatch Options Use Mode...
The address to be monitored Link aggregation group number 5.39.1.2 show icmpwatch statistics Function Display the statistics of Ethernet L3 monitor function. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show icmpwatch statistics Options Display all statistics. Use Mode...
This section explains about commands related to Ether L3 monitor function counter, log, statistics, and status clearing. 5.39.2.1 clear icmpwatch statistics Function Clear the statistics of Ethernet L3 monitor function. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax clear icmpwatch statistics Options Use Mode...
This section explains the display command related to Login information. 5.40.1.1 show users Function Display the login information. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show users [all] Options Display current login user's information. Display login information about all the lines.
Page 541
XG Series User's Guide Chapter 5 Command Reference The user class If the line isn't used, "-" is displayed. The Remote Host The Host Ip address that the user login from. The date of login or logout. The idle time for the line. Login Information Operations and Display Commands...
Login Information Operation Commands This section explains the operation command related to Login information. 5.40.2.1 clear line Function Logout user forcibly. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax clear line <line_number> clear line <line_name> <interface_number> Options <line_number>...
This section explains commands related to socket status display. 5.41.1.1 show socket Function Display the socket status. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show socket Options Display the status of all sockets. Use Mode...
Page 545
XG Series User's Guide Chapter 5 Command Reference Remote address and port number The remote address and its port number are displayed. If omitted, an asterisk (*) is displayed instead. Internal status of protocol For TCP protocol, one of the following is displayed. CLOSED : No session is established yet.
This section explains about commands related to trace show. 5.42.1.1 show trace ssh Function Show the information traced by the SSH server function. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax show trace ssh Options Use Mode...
Page 547
XG Series User's Guide Chapter 5 Command Reference Thread name The thread name is displayed. Trace dump time The trace dump time is displayed. Trace information The trace information is displayed. Trace Show and Clear Operation Commands...
This section explains about commands related to trace clear. 5.42.2.1 clear trace ssh Function Clear the information traced by the SSH server function. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax clear trace ssh Options Use Mode...
Ethernet Port Control Commands This section explains commands related to Ethernet port control. 5.43.1.1 offline Function Offline the Ethernet ports. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax offline ether [<port>] Options ether Offline all ports (linkdown).
RADIUS Control Commands This section explains RADIUS control commands. 5.44.1.1 radius recovery Function Recover the RADIUS server. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax radius recovery group <group_id> auth <number> Options <group_id> • Group ID Specify the ID of AAA group to be applied by the command.
This section explains about commands related to USB Port Control Commands. 5.45.1 USB Port Control Commands 5.45.1.1 usbctl Function Disables or enables USB ports. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax usbctl <mode> Options <mode> • enable Enable USB port.
5.46.1 I'm here Commands 5.46.1.1 iamhere Function Blink the READY LED and the CHECK LED alternately. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax iamhere <mode> [<time>] Options <mode> • on Blink the READY LED and the CHECK LED alternately.
Page 557
XG Series User's Guide Chapter 5 Command Reference Explanation Displays network route. Displays the route to the specified host (IP address or host name) by sending test packets to the host with the time-to-live value in the IP datagram header set to 1 at first, then incrementally increasing by 1, and analyzing the ICMP time exceeded packets and ICMP destination unreachable packets received.
XG Series User's Guide Chapter 5 Command Reference 5.47.1.3 telnet Function Connects to a telnet server. Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Syntax telnet <host> [<port>] [{ipv4|ipv6}] [escape {<char>|none}] [srcaddr <srcaddr>] [tos <tos>] Options <host>...
Page 559
XG Series User's Guide Chapter 5 Command Reference Explanation Allows connection to and remote operation of a host/router running a telnet server. If the telnet server demands the following information, enter the information for this device as listed within the parentheses. •...
Page 563
XG Series User's Guide Chapter 5 Command Reference (1)-1 In addition to operation (1), the relevant route is added or deleted with the route change for this device and the neighboring routers. The communication via the relevant logical interface is interrupted briefly. The relevant Ethernet port is linked down or linked up.
Chapter 6 Managing the Device This chapter describes the Managing the Device. Verifying the Device Operations ........... . . 565 6.1.1 Verifying Hardware Status.
(admin class) or the configuration mode (admin class). The following example shows the information that is displayed when the "show system status" command is entered. Execution Example XG0224 When no Expansion Card is installed. # show system status Current-time : Wed Dec 10 06:07:43 2008...
Page 566
XG Series User's Guide Chapter 6 Managing the Device When a SFP+ Card is installed. # show system status Current-time : Wed Dec 10 06:03:04 2008 ---(1) Startup-time : Wed Dec 10 06:02:19 2008 ---(2) restart_cause : reset ---(3) machine_state : RUNNING ---(4) power0_state...
Page 567
XG Series User's Guide Chapter 6 Managing the Device NORMAL : The temperature is normal. HIGHWARNING : The device changes to a high temperature state. HIGHALARM : Thermal alarm occurs in the device. UNKNOWN : There are three following states. The Expantion Card without Thermal Sensor is installed.
Page 568
XG Series User's Guide Chapter 6 Managing the Device restart_cause Cause for the system startup. The following system startup causes are displayed: power on : The power has been turned on. reset : The reset command has been issued. reset switch : The [RESET] switch has been pressed. system down : System-down has occurred.
Page 569
XG Series User's Guide Chapter 6 Managing the Device slot2_temp temperature around Expansion Card (SLOT2). At the time of three following states, "--" is displayed. The Expantion Card without Thermal Sensor is installed. (CX4) The Invalid Expantion Card is installed. The Expantion Card is not installed.
Page 570
XG Series User's Guide Chapter 6 Managing the Device power_redundancy State of the redundant power unit. single : The device has no redundant power unit. redundant : The device has a redundant power unit. PSU1 state State of the power unit (PSU1). PSU2 state Type of the power unit (PSU2).
Page 571
XG Series User's Guide Chapter 6 Managing the Device XG2600 # show system status Current-time : Thu Dec 21 16:04:50 2008 ---(1) Startup-time : Thu Dec 21 16:04:36 2008 ---(2) restart_cause : power on ---(3) machine_state : RUNNING ---(4) access_direction : front access ---(5) power_redundancy...
Page 572
Device inside temperature. The following example shows the information that is displayed when the "show ether media-info" command is entered. Execution Example Execution Example (XG0224) # show ether media-info Port media type Vendor PN ---- ---------- ---------------- (1) (2) SFP(SX)
Page 573
XG Series User's Guide Chapter 6 Managing the Device Execution Example (XG0448) # show ether media-info Port media type Vendor PN ---- ---------- ---------------- (1) (2) NONE NONE SFP(LX) SCP6P44-F7-BMH NONE SFP+(LR) FTLX1471D3BCL SFP+(SR) TRS2000EN-S002 SFP+(SR) TRS2000EN-S002 NONE Execution Example (XG0440DC / XG0440DCR) # show ether media-info Port media type Vendor PN ---- ---------- ----------------...
Page 574
SFP(BX-D) SFP (1000BASE-BX-D) module is installed SFP(BX-U) SFP (1000BASE-BX-U) module is installed SFP(ZX) SFP (1000BASE-ZX) module is installed CX4 The CX4 expansion card is mounted. (Only for XG0448 / XG0224. ) SFP+(SR)SFP+ (10GBASE-SR) module is installed SFP+(LR) SFP+ (10GBASE-LR) module is installed UNKNOWN Type of the installed module is unknown NONE SFP+ module is not installed or the module of the unsupport is mounted.
XG Series User's Guide Chapter 6 Managing the Device 6.1.2 Verifying System Status Verify the system status by entering the "show system information" command in the operation mode (admin class) or the configuration mode (admin class). The following example shows the information that is displayed when the "show system information"...
XG Series User's Guide Chapter 6 Managing the Device 6.1.3 Reviewing Log Messages 6.1.3.1 Format of System Log Message System log messages from the device are classified into 4 levels -- error, info, notice and warn. In the default setting, 3 levels of system log messages (error,warn and info) are put. To display system logs, run the "show logging syslog"...
XG Series User's Guide Chapter 6 Managing the Device 6.1.3.2 Reviewing Error Logs If a fault occurred, review the error log to check fault messages. To review error logs, enter the "show logging error" command in the operation mode (admin class) or the configuration mode (admin class).
XG Series User's Guide Chapter 6 Managing the Device Saving/Restoring Configuration Information This device allows you to save/restore configuration information using the following methods: • Saving/restoring configuration information using FTP • Saving/restoring configuration information using a CompactFlash card • Saving/restoring configuration information using USB memory 6.2.1 Saving/restoring configuration information using FTP All models...
Page 581
XG Series User's Guide Chapter 6 Managing the Device • The following error message may be displayed while using ftp commands: 502 PASV command not implemented. Passive mode regused. If this error message is displayed, perform the following operation and retry the failed operation: ftp>...
Page 582
XG Series User's Guide Chapter 6 Managing the Device "5.14 Password Information", p. 262. Reference Restoring configuration information using the FTP server function The following explains how to restore configuration information using ftp commands on a PC. Put configuration information with an ftp command FTP client IP address 192.168.1.1 Precautions...
: Configuration information 2 takes effect after restart. 6.2.2 Saving/restoring configuration information using a Compact Flash Card XG0224 Available Model You can save the device’s configuration information on a CompactFlash card. If necessary, you can also restore the configuration information saved on a CompactFlash card.
XG Series User's Guide Chapter 6 Managing the Device Restoring configuration information using a CompactFlash card The following explains how to restore device configuration information that has been saved to a CompactFlash card. Insert the CompactFlash card containing the configuration information into the device’s CompactFlash card slot.
Page 585
XG Series User's Guide Chapter 6 Managing the Device Save configuration information to the USB memory. Example The following example saves configuration information 1 to the config1-1 file. # copy config1 /um0/config1-1 Block the USB port. # usbctl disable Confirm that the USB port has been blocked. Run a show usb hcd status command and ensure that the status displays "disable".
Page 586
XG Series User's Guide Chapter 6 Managing the Device Confirm that the USB port has been blocked. Run a show usb hcd status command and ensure that the status displays "disable". # show usb hcd status [USB HCD STATUS] status : disable Remove the USB memory from the device.
XG Series User's Guide Chapter 6 Managing the Device Updating Firmware This section explains how to update the firmware and initialize the settings of the device. Precautions • Before updating the firmware, do not connect the switch via the serial interface. •...
Page 588
XG Series User's Guide Chapter 6 Managing the Device Log in with the account name "ftp-admin". Log in to the device using FTP command. Login name: ftp-admin Password: The password is the one made with the "password set" command. If no password has been set, there is no need to enter one. Confirm the password with the system administrator.
System : XG2600 Firm Ver. : V01.00 (firmware version) 6.3.2 Updating Firmware Using CompactFlash card XG0224 Available Model This section explains how to update the firmware using a compact flash card. Firmware Update with a telnet or a console Follow the instructions below to transfer the firmware saved in a compact flash card using the telnet command or a console.
Page 590
XG Series User's Guide Chapter 6 Managing the Device Firmware Update with a WWW browser Follow the instructions below to transfer the firmware saved in a compact flash card using the WWW browser. Connect this device and a PC via LAN. Set an IP address which has the same network as the device for the personal computer.
XG Series User's Guide Chapter 6 Managing the Device 6.3.3 Updating Firmware Using USB memory XG0448 / XG0440DC / XG0440DCR / X2600 Available Model This section explains how to update the firmware using a compact USB memory. Firmware Update with a telnet or a console Follow the instructions below to transfer the firmware saved in a USB memory using the telnet command or a console.
Page 592
XG Series User's Guide Chapter 6 Managing the Device Firmware Update with a WWW browser Follow the instructions below to transfer the firmware saved in a USB memory using the WWW browser. Connect this device and a PC via LAN. Set an IP address which has the same network as the device for the personal computer.
Preparing the Device Precautions When the device boots up Backup Firm, the IP address of Management-port (XG2600) or LAN port (XG0224 / XG0448 / XG0440DC / XG0440DCR) is set 192.168.1.1. A problem has come up, so please connect only this device and a PC.
Page 594
XG Series User's Guide Chapter 6 Managing the Device • XG0224 / XG0448 / XG0440DC / XG0440DCR Directly connect a cable to 10/100/1000BASE-T ports of this device and the PC instead of using a HUB in between. [XG0224] [XG0440DC/XG0440DCR] Example: XG0440DCR...
XG Series User's Guide Chapter 6 Managing the Device • XG2600 • XG0224 / XG0448 / XG0440DC / XG0440DCR [XG0224] [XG0440DC/XG0440DCR] Example: XG0440DCR [XG0448] 6.4.2 Updating the Firmware You can perform firmware update by transferring the firmware from an FTP client or a compact flash card.
XG Series User's Guide Chapter 6 Managing the Device Extracting of Maintenance Information If a fault occurred, maintenance information may be requested by the device sales representative to investigate the cause of the fault. This section provides procedures for extracting maintenance information. 6.5.1 Procedure for Extracting Maintenance Information when a System/Subsystem Failure Occurred...
Chapter 7 Troubleshooting This chapter describes the Troubleshooting. To Return to the Initial Shipment Settings (Initializing Switch Configuration) ....598...
XG Series User's Guide Chapter 7 Troubleshooting To Return to the Initial Shipment Settings (Initializing Switch Configuration) In case of incorrect settings or problems, this device status can be returned to its initial shipment settings. When relocating this device, initialize the settings to the time of shipment before setting. Initialization of the setting will erase all the set data.
XG Series User's Guide Appendix SNMP Traps This appendix lists the SNMP traps supported by the device. Trap List An SNMP agent can trap events and notify the SNMP manager asynchronously. An SNMP agent sends trap when an event occurs. The following is the list of supported traps.
XG Series User's Guide Appendix List of MIBs This appendix lists the MIBs supported by the device. Standard MIB Definitions All models Available Model The following shows meaning of MIB ACCESS column. :MIB can be read only. :MIB can be read and written. –...
XG Series User's Guide Appendix Fujitsu Extension MIB XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600 Available Model The following shows meaning of MIB ACCESS column. :MIB can be read only. :MIB can be read and written. – :MIB can not be accessed.
XG Series User's Guide Appendix IEEE802.1MIB All models Available Model The following shows meaning of MIB ACCESS column. :MIB can be read only. :MIB can be read and written. – :MIB can not be accessed. B.3.1 lldpMIB Group lldpConfiguration Group Name Object identifier MIB ACCESS lldpMessageTxInterval...
XG Series User's Guide Index Index Symbols clear bridge ............. 469 clear ether statistics ..........430 clear icmpwatch statistics ........539 ! ................342 clear igmpsnoop group ........... 521 Number clear igmpsnoop statistics ........520 clear ip traffic ............462 clear ipv6 traffic .............
Page 626
XG Series User's Guide Index end ................340 Hardware Status ............. 565 ether description ............. 110 host ip address ............300 ether downrelay port ..........107 host ip6 address ............301 ether downrelay recovery cause ......109 host name ............... 300 ether downrelay recovery mode ......
Page 627
XG Series User's Guide Index lan ip6 filter ............206 lldpXdot3RemPort Group ........621 lan ip6 filter move ..........208 lldpXdot3RemPower Group ........621 lan ip6 ifid .............. 203 load ................. 380 lan ip6 ra mode ............204 Log Messages ............576 lan ip6 route ............
Page 629
XG Series User's Guide Index show interface summary ........443 snmp trap coldstart ..........271 show ip route ............447 snmp trap linkdown ..........271 show ip route kernel ..........450 snmp trap linkup ............. 272 show ip route summary .......... 449 snmp trap lldpremtableschange ......
Page 630
XG Series User's Guide Index time auto interval ............ 292 time auto server ............291 time summer-time ..........293 time zone ..............292 top ................341 traceroute ..............556 udp Group ............... 608 udpEndpoint Group ..........608 udpListener Group ..........608 up ................
FUJITSU LIMITED • The contents may be revised without prior notice. • Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual. • No part of this manual may be reproduced in any form without the prior written permission of Fujitsu.