ROOM AIR CONDITIONER INDOOR UNIT OUTDOOR UNIT MH18ZC1(C2)-09 MH18ZC1(C2)X MH19ZC1(C2)-07 MH19ZC1(C2)X MH19ZC1(C2)-12 MH24ZC1(C2)-12 MH24ZC1(C2)X MH26ZC1(C2)-07 MH26ZC1(C2)X MH26ZC1(C2)-12 Manual SERVICE AIR CONDITIONER CONTENTS 1. Precautions 2. Product Specifications 3. Operating Instructions and Installation 4. Disassembly and Reassembly 5. Troubleshooting 6. Exploded Views and Parts List 7.
Relocate the unit if necessary. 9. Keep children away from the unit while it is being repaired. 10. Be sure to clean the unit and its surrounding area. Fig. 1-3 No Kids Nearby! Fig. 1-4 Clean the Unit Samsung Electronics...
5.4~5.6 Low temp. 3.5~3.7 Cooling Standard 5.0~5.2 A + B Max over load 5.4~5.6 Low temp. 3.5~3.7 Standard 17~19 A or B Max over load 19~25 Deice Heating Standard 17~19 A + B Max over load 19~25 Deice Samsung Electronics...
To select the 5 way function with the remote control, press the 5 way button one or more times until the desired mode is selected.. Each time you press the 5 way button Each 5 way indicator on the indoor unit comes on in or der. Samsung Electronics...
Page 13
4. DRY MODE : Has 3 states, each deter- mined by room temperature. The unit operates in DRY mode. *Compressor ON/OFF Time is controlled compulsorily(can not set up the fan speed, always breeze). *Protective function : Low temperature release. (Prevention against freeze) Samsung Electronics...
Page 14
The air conditioner is turned ON at a spec- ified time using OFF TIMER : The air Conditioner is turned OFF at a specified time using *ON TIMER : Only timer LED lights on. *OFF TIMER : Both timer and operation LED lights on. Samsung Electronics...
Page 15
•In case of 2Unit, Capacity & Current multiplied by 2 Cooling Capacity & Air Outlet Temperature Cooling Capacity Air Outlet Temp 13000 12000 11000 21/15 21/19 35/24 43/26 Outdoor Temperature(DB/WB) Current & Low Pressure Current Low Pressure 21/15 21/19 35/24 43/26 Outdoor Temperature(DB/WB) Samsung Electronics...
Page 16
•In case of 2Unit, Capacity & Current multiplied by 2 Heating Capacity & Air Outlet Temperature Heating Capacity Air Outlet Temp 14000 13000 12000 11000 10000 9000 8000 7000 -5/-6 Outdoor Temperature(DB/WB) Current & Low Pressure Current Low Pressure -5/-6 Outdoor Temperature(DB/WB) Samsung Electronics...
Page 17
Operating Instructions and Installation 3-2-1(b) MH18ZC1(C2)-09 / MH19ZC1(C2)-07 / MH26ZC1(C2)-07 • Cooling Characteristics - Outdoor Temperature Test Condition Indoor Unit(DB/WB) : 27/19 Voltage/Frequency : 240V/50Hz Cooling Capacity & Air Outlet Temperature Cooling Capacity Air Outlet Temp. 10000 9000 8000 7000...
Page 18
Test Condition Indoor Unit(DB/WB) : 20/15 Voltage/Frequency : 240V/50Hz Heating Capacity & Air Outlet Temperature Heating Capacity Air Outlet Temp. 10500 9500 8500 7500 Outdoor Temperature(DB/WB) Heating Capacity & High Pressure Heating Capacity High Pressure 10500 9500 8500 7500 Outdoor Temperature(DB/WB) Samsung Electronics...
7) Pull the upper left and right of discharge softly for the outside cover to be pulled out. 8) Pull softly the lower part of discharge and push it up. Caution; Assemble the front panel and fix the hooks of left and right. Samsung Electronics...
Page 21
2) Loosen the fixing two screws and separate the motor holder. 3) Loosen the fixing screw of fan motor. (By use of M3 wrench) 4) Separate the fan motor from the fan. 5) Separate the fan from the left holder bearing. Samsung Electronics...
Page 22
<MH18ZC1(C2)X/MH19ZC1(C2)X> Fan Motor 1) Do Procedure 1 above. <MH24ZC1(C2)X/MH26ZC1(C2)X> & 2) Remove the nut flange. Propeller Fan (Turn to the right to remove as it is a left turned screw) 3) Disassemble the propeller fan. <MH18ZC1(C2)X/MH19ZC1(C2)X> Samsung Electronics...
In case that the communication between the indoor unit and outdoor unit is not made for 60 seconds Outdoor sensor Error (open or short) (GREEN) - Outdoor sensor - Pipe sensor A, B (GREEN) The malfunction ot 4way valve in heat mode operation. Samsung Electronics...
$ When pressing the button appear on the display, select one of them. % When pressing the button appear on the display, select one of them. ^ When pressing the button appear on the display, select one of them. Samsung Electronics...
Page 26
If all lamps of indoor unit are flickering, Plug out and plug in again and pressing ON/OFF key to retry. If the unit is not working properly or all lamps are continuously flickering after setting the option code, see if the correct option code is set up for it’s model. Samsung Electronics...
Page 28
• Perform the test operation only for the unit selected last. • Check the pipe pressure and the other operation status during the test operation. • Check items when the error occurs during the test operation (each unit) - Check there is enough refrigerant. - Check pipe connections. Samsung Electronics...
Page 29
Communication unit number display : C unit •During the test operation the unit under test (In case of triple split multi air conditioner) is on and off every 0.25s. Refrigerant leaks High temperature of the A cond High temperature of the B cond Samsung Electronics...
Check PCB pattern. Replace ICO2 Replace main PCB. 10ms Is voltage output terminal of TLP180(PC02) normal? Are voltage at #48 and #49 of the micom normal? Replace resonator (X301) 250ns Replace TLP180(pc02) Is operation normal? Replace micom Samsung Electronics...
Page 31
IC (KA 7812) DC 10V and 12V? D105) and KA7812. Is the output voltage of electrostatic voltage KA7805 is out of order - replace regulator IC (KA 7805) DC 4.5 V - 5.5 V? Replace the main PCB of indoor unit Samsung Electronics...
Page 32
(D101 - D104) IC01 (KA 7812) is DC 12V. and KA 7812. Check whether the output voltage of Replace the IC 02 (KA7805) IC02 (KA 7805) is DC 5V. Replace the outdoor unit Ass'y main PCB. Samsung Electronics...
Page 33
Replace the IC 06 (KID 65003) and the old type? SS71(G3MB202pl). 120Hz Is the pin no 25 of MICOM Replace Q401 (Ksc 945Y). the old type? Replace the indoor unit PCB Ass'y due to the Micom defect. 5-10 Samsung Electronics...
Page 34
(3) Perform the comp ON/OFF control in the dry mode. (4) When it is under the operation of anti-freezing, overload protection, defrost operation, it may be Low, high or Off. (5) Hi = High speed, Low = Low speed Samsung Electronics 5-11...
Page 35
Normal trol unit pushed? Voltage at pin #33-#36 of micom (ICO4) Micom (IC04) is faulty. change?(Squarewave) Volatge at pin #13, #14, #15, #16 of IC05 (KID65003) Driver IC05 (KID65003) is faulty. change?(Squarewave) UP/DOWN louver motor is faulty. 5-12 Samsung Electronics...
Voltage at PIN #30 of Remocon Micom change? Voltage at collecter of Q601 or Q602 change? Q601(C4375Y) or Q602(C1623Y) is faulty. IR LED(CL-1L5EU) is faulty. Voltage at pin #26 of micom (IC04) change (INDOOR UNIT)? Receiver module is faulty. Micom (IC04) is faulty. Samsung Electronics 5-13...
Page 37
(3) The changeover of heating to cooling : put the 4 way valve off immediately (in case of B and C room). (4) The changeover of cooling to heating : it is on after 170 seconds delay. 5-14 Samsung Electronics...
* Comp A( ) power measuring terminal (1) Comp A measuring ; RY 73 (4) ↔ RY 72 (4) RY71 (2) Comp B measuring ; RY 71 (4) ↔ RY 72 (4) (3) Power input ; RY 72 (3) ↔ RY 73(3) RY73 Samsung Electronics 5-15...
5-5-2 Procedure The parts should be replaced in the following procedure. Check for any faulty part. Detach the faulty part. Replace it with a new part. Check the operation of the new part. The repair is completed. 5-16 Samsung Electronics...
Page 40
1. Indoor unit fan motor is faulty. RMC switch pushed. above 180V~ 1. [FAN] mode 2. Fan speed [Hi] 2. Indoor unit fan motor does not operate. 2. Poor connection of indoor fan motor 3. Continuously operation and connector of RPM sensing (CN43) Samsung Electronics 5-17...
∞, O Ω … open or short Abnormal Measure resistance between red wire and each terminal. Stepping Motor Normal Approx. 380Ω at ambient temperature (20˚C ~30˚C) (UP/DOWN swing motor) ∞, O Ω … open or short Abnormal 5-18 Samsung Electronics...
6. Exploded Views and Parts List 6-1 Indoor Unit 20-6 20-6-1 20-1 20-4 20-5 20-3 20-2 13-2 13-3 13-4 17 18 13-1 You can search for the updated part code number through the ITSELF. URL : http://itself.sec.samsung.co.kr Samsung Electronics...
Page 44
Exploded Views and Parts List Parts List Q’TY CODE NO Description MH18ZC1(C2)-09 MH19ZC1(C2)-07 MH19ZC1(C2)-12 MH24ZC1(C2)-12 MH26ZC1(C2)-07 MH26ZC1(C2)-12 DB64-00354A GRILLE-AIR INLET DB63-00064A GUARD-AIR FILTER DB95-00287G ASSY-CLEANER FILTER DB63-00067A COVERTER-TERMINAL DB92-00248A ASSY PANEL-FRONT DB67-00051A SPACER-EVAP LOW DB67-00032A SPACER-EVAP UP DB63-00083A COVER U-BEND...