Split-type room air conditioner (cool and heat) (26 pages)
Summary of Contents for Samsung AQB09JJWC
Page 1
Silver Nano Pre-Filter ■ Multi Functional Cleaning System ■ AQB09JJWC/AQB12JJWC : The Chatechin filter and activated Deodorizing filter ■ are adopted. Human Touch Remote control ■ UQB09JJWC/UQB12JJWC For more information, Please access to our service web site(http://itself.sec.samsung.co.kr) 26006A(2)_co.indd 2006-04-14 ソタネト 5:11:24...
5-1 Indoor Unit ..............................5-2 Outdoor Unit ............................. 5-3 Ass’y Control In ............................5-4 Ass’y Control Out ............................16. Electrical Parts List ..........................17. Wiring Diagram ............................7-1 Indoor Unit ..............................7-2 Outdoor Unit ............................Samsung Electronics 26006A(2)_1.indd 2006-04-14 ソタネト 5:12:25...
Do not place a cloth or other materials over it. ● Remove the batteries if you don’t use the remote control for a long time. (If applicable) ● Use the remote control within 7 meters from the indoor unit. (If applicable) Samsung Electronics 26006A(2)_1.indd 2006-04-14...
● Young children or infirm persons should be always supervised when they use the air conditioner. ● Max current is measured according to IEC standard for safety. ● Current is measured according to ISO standard for energy efficiency. Samsung Electronics 26006A(2)_1.indd 2006-04-14...
■ Multi functional cleaning system Multi Chatechin filter and activated Deordorizing filter are adopted. ■ Human touch remote control The use of air conditioner is easier and more convenient by the human touch remote control of new design. Samsung Electronics 26006A(2)_1.indd 2006-04-14 ソタネト 5:12:26...
17 lb Net Weight Outdoor Unit 78 lb 79 lb Indoor Unit 32.5x11.2x7.4 inch 32.5x11.2x7.4 inch Outer Dimension (WidthxHeightxDepth) Outdoor Unit 31.1x21.6x11.2 inch 28.4x21.6x10.4 inch Indoor Unit 43dB 43dB Noise Outdoor Unit 53dB 53dB Samsung Electronics 26006A(2)_1.indd 2006-04-14 ソタネト 5:12:27...
Remote Control DB93-03012K Batteries for Remote Control DB47-90024A Indoor Unit User’s Manual DB98-25865A Installation Manual DB98-25853A Service Manual DB98-26006A Drain Plug DB67-20011A Outdoor Unit Rubber Leg DB73-00179A 3-wire Power Cable Accessory 2-wire Assembly Cable Samsung Electronics 26006A(2)_1.indd 2006-04-14 ソタネト 5:12:29...
Page 10
DB96-10453B Assembly Pipe,ø3/8 inch(9.52mm) DB96-10453F PE T3 Foam Tube Insulation DB72-50165A Vinyl Tape, Width 2 inch(50mm) DB72-00459A Accessory Drain Plug DB67-20011A Rubber Leg DB73-00179A Pipe Clamps A DB39-20224A Pipe Clamps B DB39-20224B Cement Nail Samsung Electronics 26006A(2)_1.indd 2006-04-14 ソタネト 5:12:30...
Indoor fan motor malfunction 3-4P EEPROM error Option Setting Option error Option Setting (option wasn’t set up or option data error) Remote Control on/off Outdoor unit error Outdoor Unit Power Reset Lamp on, Lamp off, Lamp blink Samsung Electronics 26006A(2)_1.indd 2006-04-14 ソタネト 5:12:30...
Page 13
Connect the sensor to CN43, supply power, and measure the voltage of #1 and #2 of the CN43 connector. Poor ASS'Y PCB Replace Below 0.5V? Poor ASS'Y PCB Replace Over 4.9V? MICOM Error or Connector(CN43) check Samsung Electronics 26006A(2)_1.indd 2006-04-14 ソタネト 5:12:31...
Page 14
3. Assemble the room pipe sensor to PCB, plug in, and check the voltage of connector 3 and 4. If the resistance is below 0.5V or over 4.9V, replace the indoor Main PCB. (short or disconnected in the PCB board) Samsung Electronics 26006A(2)_1.indd 2006-04-14 ソタネト...
Page 15
Test rod location Normal voltage PCB CN72 Condition pin #3 and #5 Fan operating About AC180V Replace Motor Motor Fan-Capacitor is out of order Fan-Capacitor Fan motor should be replaced. Fan motor is out of order. Samsung Electronics 26006A(2)_1.indd 2006-04-14 ソタネト 5:12:32...
Power ON reset(1sec) • PCB pattern (Open/Short) Capacity miss match • Option code Test Operation at Cooling Mode • Operating mode Test Operation at Heating Mode • Operating mode LED ON, LED OFF, LED BLINK Samsung Electronics 26006A(2)_1.indd 2006-04-14 ソタネト 5:12:32...
Setting Option SEG4. Push the button to set the display panel to Every time you push the button, the display panel reads ➡ ➡ ➡ . . . repeatedly. ➡ ➡ ➡ ➡ ➡ ➡ ➡ Samsung Electronics 26006A(2)_1.indd 2006-04-14 ソタネト 5:12:37...
Page 18
Setting Option SEG10. Push the button to set the display panel to Every time you push the button, the display panel reads ➡ ➡ ➡ . . . repeatedly. ➡ ➡ ➡ ➡ ➡ ➡ ➡ Samsung Electronics 26006A(2)_1.indd 2006-04-14 ソタネト 5:12:47...
Page 19
If all lamps of indoor unit are flickering, Plug out, plug in power plug again and press ON/OFF key to retry. If the unit is not working properly or all lamps are continuously flickering after setting the option code, see if the correct option code is set up for its model. Samsung Electronics 26006A(2)_1.indd 2006-04-14...
2) Open the Front Grille by pulling right and left sides of the hook. 3) Loosen 1 of the right screw(CCW) and detach the Terminal Cover. 4) Detach the thermistor from the Front Grille. 5) Loosen 3 fixing screws(CCW) of Front Grille. Samsung Electronics 26006A(2)_1.indd 2006-04-14 ソタネト 5:12:53...
Page 22
(Inclusion Power Cord) 2) Detach the outdoor unit connection wire from the Terminal Block. 3) Loosen 4 fixing screws(CCW) of Ass'y Control-In. Tray Drain 1) Pull Tray Drain out from the Back Body. Samsung Electronics 3-11 26006A(2)_1.indd 2006-04-14 ソタネト 5:12:54...
Page 23
Fan Motor 1) Loosen the fixing screw(CCW). & 2) Detach the Fan Motor from the Fan. Cross Fan 3) Detach the Fan From the left Holder Bearing. Samsung Electronics 26006A(2)_1.indd 2006-04-14 ソタネト 5:12:55...
Cabinet Front lower to detach the Cabinet Front. 3) Detach the Cabinet Front like the picture on the right side. 4) Loosen 1 screw(CCW) fixed to assemble Plate Control Out with Cabinet-Side RH. Samsung Electronics 26006A(2)_1.indd 2006-04-14 ソタネト 5:12:56...
Page 25
Remark 5) Loosen 2 fixing screws(CCW) on the rear side of Cabinet-Side RH. 6) Loosen 3 screws(CCW) fixed to assemble Bracket Valve with Cabinet-Side RH. 7) Loosen 2 fixing screws(CCW) of Cabinet Side LF. Samsung Electronics 26006A(2)_1.indd 2006-04-14 ソタネト 5:12:57...
Page 26
1) Detach the Motor Wire from the PCB of Ass'y Control Out. 2) Detach several connectors from the PCB of Ass'y Control Out. 3) Detach 2 Connect Wires from Reactor. 4) Loosen 1 screw(CCW) fixed to assemble Ass'y Control Out with Partition. Samsung Electronics 26006A(2)_1.indd 2006-04-14 ソタネト 5:12:58...
Page 27
2) Detach the Terminal Cover and detach the Connect Comp Wire from Compressor. 3) Disassemble the Felt Comp Sound. 4) Loosen the 3 bolts(CCW) at the bottom of Compressor like the picture on the right side. Samsung Electronics 26006A(2)_1.indd 2006-04-14 ソタネト 5:12:58...
5. Exploded Views and Parts List 5-1 Indoor Unit Samsung Electronics 26006A(2)_1.indd 2006-04-14 ソタネト 5:13:01...
Page 30
Exploded Views and Parts List ■ Parts List Q'TY Code No. Description Specification SA/SNA AQB09JJWC AQB12JJWC DB94-00454B ASS’Y-BACK BODY ASS’Y DB61-01632A BACK-BODY HIPS DB69-00834A CUSHION-BACK BODY DB61-01634A SUPPORTER-EVAP RH HIPS DB31-00219A MOTOR-IN YDK-016S1408-01 DB94-00456A ASS’Y-CROSS FAN OD92x635 DB97-02075A ASS’Y-BOLT SPECIAL ASS’Y...
7. Wiring Diagram 7-1 Indoor Unit This Document can not be used without Samsung’s authorization. Samsung Electronics 26006A(2)_1.indd 2006-04-14 ソタネト 5:13:30...
Operating Instructions and Installation 7-2 Outdoor Unit This Document can not be used without Samsung’s authorization. Samsung Electronics 26006A(2)_1.indd 2006-04-14 ソタネト 5:13:30...
8. Schematic Diagram 8-1 Indoor Unit This Document can not be used without Samsung’s authorization. Samsung Electronics 26006A(2)_1.indd 2006-04-14 ソタネト 5:13:32...
8-2 Outdoor Unit ■ Inverter This Document can not be used without Samsung’s authorization. Samsung Electronics 26006A(2)_1.indd 2006-04-14 ソタネト 5:13:36...
Page 55
Schematic Diagram ■ Main This Document can not be used without Samsung’s authorization. Samsung Electronics 26006A(2)_1.indd 2006-04-14 ソタネト 5:13:38...
9-1 PCB Circuit Descriptions 9-1-1 Indoor Unit SMPS BUZZER PART INDOOR FAN CONTROL SUB PCB CONNECTOR ZERO CROSSING PART DISPLAY INDOOR TEMPERATURE SENSOR STEP MOTOR & ION This Document can not be used without Samsung’s authorization. Samsung Electronics 26006A(2)_1.indd 46-47 2006-04-14 ソタネト 5:19:55...
Page 58
Circuit Descriptions Circuit Descriptions 9-1-2 Outdoor Unit(Inverter) BLDC FAN INVERTER SMPS MICOM COMMUNICATION This Document can not be used without Samsung’s authorization. Samsung Electronics 26006A(2)_1.indd 48-49 2006-04-14 ソタネト 5:19:57...
Page 59
Circuit Descriptions Circuit Descriptions 9-1-3 Outdoor Unit(Main) TEMPERATURE SENSOR & EEV 485 COMMUNICATION This Document can not be used without Samsung’s authorization. Samsung Electronics 26006A(2)_1.indd 50-51 2006-04-14 ソタネト 5:19:59...
Temperature Sensor Motor RPM Feedback BLADE-H Step Motor Remocon Module HVPS(High voltage Generator) Humidity Sensor DISPLAY PCB Connection Anions Melody PCB Connection Auto grill 1 Test Board Connection Auto grill 2 Indoor Fan Motor Samsung Electronics 10-1 26006A(2)_1.indd 2006-04-14 ソタネト 5:13:59...
10-2 Outdoor Inverter PCB Power N Power Relay Power L Comp. Connector Wire BLDC Fan : YAW396-07V (WHT) Reactor Connector Wire Main PCB Connector : SMW200-07(WHT) 10-2 Samsung Electronics 26006A(2)_1.indd 2006-04-14 ソタネト 5:14:04...
11-1-1 Indoor Unit The design and shape can be changed according to the model. Air Inlet Temperature sensor Air filter Air flow blades (under the grille) (outlet) Operation indicator(Green) Timer indicator(Green) Turbo indicator(Red) On/Off button 11-1 Samsung Electronics 26006A(2)_1.indd 2006-04-14 ソタネト 5:14:08...
Page 65
11-1-2 Outdoor Unit Air Inlet(Rear) Air Outlet Connection Valve (inside) Samsung Electronics 11-2 26006A(2)_1.indd 2006-04-14 ソタネト 5:14:09...
Turbo (Maximum) Press the button on the remote control until is displayed. Heat Mode Press the button to select the fan speed until the required setting is displayed. Automatic (rotated : Medium High 11-3 Samsung Electronics 26006A(2)_1.indd 2006-04-14 ソタネト 5:14:12...
Page 67
You can select the Turbo function in the Auto, Cool and Heat mode. If you select this function in the Dry or Fan mode, the mode changes to the Auto mode. Energy Saving Press the button. Function Samsung Electronics 11-4 26006A(2)_1.indd 2006-04-14 ソタネト 5:14:16...
• You can check the battery life by pressing the button. Note : • The number of the battery life indicator means the remaining battery life. Replace the batteries when only one battery life indicator remains. 11-5 Samsung Electronics 26006A(2)_1.indd 2006-04-14 ソタネト 5:14:17...
Indoor fan and outdoor fan stop operation intermittently exterior ice in a HEAT mode, and indoor fan and outdoor in a HEAT mode. fan do not operate intermittently for within 20% of the total heater operation Samsung Electronics 12-1 26006A(2)_2.indd 2006-04-14 ソタネト 5:16:08...
Replace fuse 20[A]/250[V] Check the input/output voltage of SMPS on the INV PCB. PCB should be replaced DC_Link voltage(C101):DC300[V] IC16, IC19 Input:DC12[V] output: DC5[V] ◆ Check the setting temperature 12-2 Samsung Electronics 26006A(2)_2.indd 2006-04-14 ソタネト 5:16:09...
Separate the BLDC FAN Wire Is the number 1, 3 of the Is the +, - of C102 Short? BLDC FAN Wire Short? Replace the PCB Replace the BLDC FAN Normal Operation Exit Samsung Electronics 12-3 26006A(2)_2.indd 2006-04-14 ソタネト 5:16:09...
Page 72
(Square-Wave) execute the following step after 30 seconds. Disassemble the BLDC FAN Wire. Is the short between Exchange the PCB. the BLDC FAN Wires? Exchange the BLDC FAN MOTOR. Exchange the PCB. 12-4 Samsung Electronics 26006A(2)_2.indd 2006-04-14 ソタネト 5:16:09...
Page 73
Pull out the power cord and exchange the PCB from the case after 30 seconds. Is the assembly of Micom and Exchange the PCB. peripheral circuit part good? Check again after assembly of PCB. Samsung Electronics 12-5 26006A(2)_2.indd 2006-04-14 ソタネト 5:16:09...
Page 74
4-WAY valve coil. Dose the voltage of AC 220V Exchange apply to the connector of 4-WAY the outdoor PCB. valve coil during the operation? Go to the next page 4-WAY valve main body error 12-6 Samsung Electronics 26006A(2)_2.indd 2006-04-14 ソタネト 5:16:10...
Page 75
Check the resistance value Outdoor fan error of outdoor fan. Dose the voltage of DC300V apply to the connector of outdoor Check the motor wire. fan during the operation of outdoor unit? Outdoor PCB error Samsung Electronics 12-7 26006A(2)_2.indd 2006-04-14 ソタネト 5:16:10...
Exchange the sensor. (Refer to the R/T TABLE) Is the resistance value of sensor connection pull_up 18K? Exchange the PCB. Exchange the PCB. Normal operation Exit 400.0 350.0 300.0 250.0 200.0 150.0 100.0 50.0 12-8 Samsung Electronics 26006A(2)_2.indd 2006-04-14 ソタネト 5:16:10...
Page 77
Exchange the sensor. (Refer to the R/T TABLE) Is the resistance value of sensor connection pull_up 24K? Exchange the PCB. Normal operation Exchange the PCB. Exit 600.0 500.0 400.0 300.0 200.0 100.0 Samsung Electronics 12-9 26006A(2)_2.indd 2006-04-14 ソタネト 5:16:11...
Exchange the sensor. (Refer to the R/T TABLE) Is the resistance value of sensor connection pull_up 18.2K? Exchange the PCB. Exchange the PCB. Normal operation Exit 400.0 350.0 300.0 250.0 200.0 150.0 100.0 50.0 12-10 Samsung Electronics 26006A(2)_2.indd 2006-04-14 ソタネト 5:16:12...
Page 79
Remove the Fan lock. Isn't the Fan locked? Is the connector connected correctly? Connect the connector. Is the color of Fan wire matched correctly? Exchange the Fan. Exchange the PCB. Normal operation Exit Samsung Electronics 12-11 26006A(2)_2.indd 2006-04-14 ソタネト 5:16:12...
Page 80
Is the capacitor(C101, C102, C103) Connect the connector. for DC-Link assembled in accordance the specification? Are R113, R114, R115 470kohm? Exchange the PCB. Is R116 14.3kohm? Exchange the Fan. Exchange the PCB. Normal operation Exit 12-12 Samsung Electronics 26006A(2)_2.indd 2006-04-14 ソタネト 5:16:12...
Page 81
Is the position of temperature sensor Correct the sensor position or and the sensing value normal? exchange the sensor. Is the connection cable for Correct the cable connection. the compressor and power terminal normal? Exchange the PCB. Samsung Electronics 12-13 26006A(2)_2.indd 2006-04-14 ソタネト 5:16:13...
Is the connection of Correct the connection of communication cable normal? communication cable. Is it the outdoor Exchange the indoor/outdoor unit PCB. 2 Micom(Inverter + Main) model? Exchange the outdoor unit PCB. 12-14 Samsung Electronics 26006A(2)_2.indd 2006-04-14 ソタネト 5:16:13...
(u↔v, v↔w, w↔u) normal? Is the compressor body and Exchange the compressor. interphase resistance insulated? Is the connection cable for the Correct the cable connection. compressor and power terminal normal? Exchange the PCB. Samsung Electronics 12-15 26006A(2)_2.indd 2006-04-14 ソタネト 5:16:13...
(u↔v, v↔w, w↔u) normal? Is the compressor body and Exchange the compressor. interphase resistance insulated? Is the connection cable for the Correct the cable connection. compressor and power terminal normal? Exchange the PCB. 12-16 Samsung Electronics 26006A(2)_2.indd 2006-04-14 ソタネト 5:16:13...
Page 85
Is the resistance for the Exchange the PCB. detection of DC Link voltage normal? Is the resistance value of Exchange the PCB. DC Link discharge normal? Is the reactor insulation damaged? Exchange the PCB. Exchange the reactor. Samsung Electronics 12-17 26006A(2)_2.indd 2006-04-14 ソタネト 5:16:13...
Page 86
1. AC Line Zero Cross Signal OUT – Check the assembly condition of peripheral part of IC21, ZD201, ZD200 and D201 on the PCB. 2. Capacity miss match – Check again the indoor unit option code. 12-18 Samsung Electronics 26006A(2)_2.indd 2006-04-14 ソタネト 5:16:14...
2) The fan motor of the indoor unit doesn't run. • Fan Motor Connector(CN72) is faulty 3) The power voltage between terminal #3 and #5 • ASS'Y Main PCB is faulty • of the connector(CN72) is 0V. Connection is faulty Samsung Electronics 12-19 26006A(2)_2.indd 2006-04-14 ソタネト 5:16:14...
Outdoor PCB Error 2) Is CN01 3, 5 within 1~5V? • BLDC Motor Error 3) Is the voltage of CN01 6 changed? 4) Is the resistance of BLDC Motor 1, 3 opened after power off? 12-20 Samsung Electronics 26006A(2)_2.indd 2006-04-14 ソタネト 5:16:14...
Stepping Motor Measure the resistance between the red wire and each terminal wire with a tester. Normal About 300Ω at the normal temperature [68˚F~86˚F(20˚C~30˚C)] Abnormal ∞, 0Ω . . . Open or Short Samsung Electronics 12-21 26006A(2)_2.indd 2006-04-14 ソタネト 5:16:14...
SELECT(UP/DOWN) : BLADE CONTROL SLEEP OPERATION MELODY CONTROL PART ANION SELECT DC5V VOLTAGE REGULATOR AUTO CLEAN SELECT SPEAKER ENERGY SAVING SELECT OPTION SOUND ON/OFF SELECT DC12V SMPS POWER BLOCK DIGITAL ON/OFF AC INPUT 13-1 Samsung Electronics 26006A(2)_2.indd 2006-04-14 ソタネト 5:16:15...
Page 91
Block Diagram BUZZER CONTROL INDOOR FAN CONTROL SMPS 485 COMMUNICATION SUB-PCB Samsung Electronics 13-2 26006A(2)_2.indd 2006-04-14 ソタネト 5:16:15...
• AC FAN CONTROL SIGNAL • EEV CONTROL SIGNAL • 4-WAY VALVE • 4-WAY CONTROL SIGNAL • EEV • LED CONTROL SIGNAL • INDOOR COMMUNICATION SIGNAL INDOOR UNIT SMPS AC INPUT PFC CIRCUIT 13-3 Samsung Electronics 26006A(2)_2.indd 2006-04-14 ソタネト 5:16:15...
Page 93
Block Diagram ■ Inverter PCB OUTDOOR FAN POWER RELAY IGBT DIODE DC_LINK CAP SMPS Samsung Electronics 13-4 26006A(2)_2.indd 2006-04-14 ソタネト 5:16:16...
14-1 Index for Model Name ✳ Project model code for New Built-in Product. Model Code Buyer code kBtu In/Out Technical Grill Design R22+Inv WW-Premium R22+BLDC WW-Standard R410A+BLDC H/P, C/O Outdoor Chassic Power Source (Europe)220~240V, 50Hz (US)208~230V, 60Hz Samsung Electronics 14-1 26006A(2)_2.indd 2006-04-14 ソタネト 5:16:17...
It occurs when the drain pump is plugged out or it is out of order. Check the power of the drain pump and the position of the drain hose, and when the pump is faulty, contact the drain pump manufacturer. Samsung Electronics do not manufacture drain pumps.
Page 98
Also, the remote controller may not work under intensive light from a 3-wavelength lamp or a neon sign due to the EMI. In this case, take the remote controller closer to the receiver. 14-4 Samsung Electronics 26006A(2)_2.indd 2006-04-14 ソタネト 5:16:19...
Page 99
There is a cost table. But, our service engineer needs to visit to total up the cost correctly. When you move in, make sure to contact Samsung Electronics Service Center or Authorized Service Agent in advance to streamline the process.
Body Note : • If you have not used the air conditioner for a long time, select the Fan mode for 3 to 4 hours to dry the inside of the air conditioner. 14-6 Samsung Electronics 26006A(2)_2.indd 2006-04-14 ソタネト 5:16:20...
Page 101
3. Wash the filters with clean water, then dry them in the shade. Bio Filter Deodorizing Filter 4. Insert the filters in their place. Note : • You can change the position of filters with each other. 5. Close the front grille. Samsung Electronics 14-7 26006A(2)_2.indd 2006-04-14 ソタネト 5:16:20...
Electric and earth work shall meet the "Electric Facility Technology Standard" and the "Internal Wire Regulation" of the Electric Business Laws. ■ Inspection & Trial Run Upon completion of the tests, you shall make a trial run while you explain the main functions of the air conditioner to finish the installation. 14-8 Samsung Electronics 26006A(2)_2.indd 2006-04-14 ソタネト 5:16:21...
183kgf . cm with a torque wrench. 7) Check for gas leakage. - At this time, especially check for gas leakage from the 3-Way valve’s stem nuts, and from the service port cap. Samsung Electronics 26006A(2)_2.indd 2006-04-14 ソタネト 5:16:21...
• Make sure you do not bend the connection pipes in the middle and store together with the cables. • Move the indoor and outdoor units to a new location. • Remove the mounting plate for the indoor unit and move it to a new location. 14-10 Samsung Electronics 26006A(2)_2.indd 2006-04-14 ソタネト 5:16:22...