  • Page 1 ® EntryCom Door Entry System User and Service Manual Version 2.0...
  • Page 2: 2 . T E C H N I C A L P A R A M E T E R

    Dear customer, ® We congratulate you on having purchased the 2N EnrtyCom door ® communicator, which is the successor to the popular product 2N . We NTRY OM V1 hope you will fully enjoy using this new product for a long time to come. Merits of the Product 1.
  • Page 3: Table Of Contents

    FEATURES ....................4 1.1. : ......................4 PTIONAL CCESSORIES PURPOSE ....................5 P R O D U C T MIX ..................... 6 3.1......................6 ASIC AND XTENDER NITS 3.2......................7 NSTALLATION CCESSORIES 3.3..................8 NCREASED ROTECTION CCESSORIES 3.4.
  • Page 4: Features

    1. Features • Operates on any analogue telephone line • Telephone-controlled electronic lock switch • Exclusive white button backlight – white LEDs • Modularity – up to 54 buttons + keypad • Applicable as a standard telephone and code lock (keypad version) •...
  • Page 5: Purpose

    ® - EntryCom is also easy to use – just press the desired call button and the EntryCom unit will automatically “dial“ the number pre-stored in the respective memory. The number of buttons is flexible as it is a modular unit.
  • Page 6: Product Mix

    3. Product Mix Basic and Extender Units 3.1. Part No. 9135130E Part No. 9135130KE Part No. 9135181E Basic unit Basic unit Extender unit 3 buttons 3 buttons + keypad 8 buttons Part No. 9135160E Part No. 9135160KE 913582E Part No. Basic unit Basic unit Extender unit...
  • Page 7: Installation Accessories

    All mounting accessories are made from stainless steel particularly necessary for outdoor applications unless there is suitable weather protection. The flush mounting frame box (without roof) enables installation of the EntryCom unit indoors so that it does not protrude from the wall (up to 1 mm).
  • Page 8: Increased Protection Accessories

    Increased Protection Accessories 3.3. Part No. 9135511KE Part No. 9135515E Part No. 9135511E Vandal resistant cover for Vandal resistant cover for one Vandal resistant cover for basic basic unit with keypad + Flush extension unit + Flush unit + Flush mounting box *) mounting box *) mounting box *) *) Attention! This box is not 9135351E !!! It is a special box only for Vandal resistant covers.
  • Page 9: Video Accessories

    Video Accessories 3.6. Part No. 9135210E Part No. 9134147E Part No. 9134145E In-built colour CCD camera 7" colour LCD monitor (TFT) MPEG4 LAN video server Video records can be observed by anybodies PC via the LAN, no SW installation is needed. Serves up to 10 PCs PAL, resolution 420 TV rows, sensitivity 2 lux The selected model features a at the same time.
  • Page 10: Terminology

    DTMF – dual tone multi-frequency signalling. PSTN – public switched telephone network. Outgoing call – EntryCom-telephone connection made, e.g. by a pressing a button. Incoming call – telephone-EntryCom connection. Programming mode – EntryCom programming mode accessible from by dialling into the intercom only.
  • Page 11: Function Description

    If the EntryCom unit is connected to a telephone system you may be able to tag the port that EntryCom is connected to so that you can see on the ringing phone that it is the EntryCom that is calling. When the called party answers the call, the visitor and...
  • Page 12: From Internal User's View (Survey Of Functions)

    You call the appropriate extension and EntryCom makes the call and gives a confirmation tone after two rings (or as pre-programmed). Now you can speak and control the 2 switches, program EntryCom (see later), and listen to what is going on outside and speak to the calling party if desired..
  • Page 13: Signals Overview

    • can be heard from the loudspeaker after line connection (first Refusal connection signalling); • signals an incoming call if EntryCom has not been programmed; When a disabled function has been entered from the keypad. • • Signals switch deactivation (if activated by DTMF).
  • Page 14: Call Termination Options - Summary

    Code Lock 5.7. The electronic lock connected to the EntryCom can not only be activated by the phone but also directly from the door using the keypad. In this mode, the keypad behaves like a standard code lock with the following features: •...
  • Page 15: Dtmf Transmission During Outgoing Call

    01 and 54 (0 may not be omitted) are pressed, the call to the pre-programmed number is made. You can use EntryCom as if it had up to 54 separate buttons, which saves buying the extender units and space on the installations wall. The ideal solution is to use a few standard buttons for the most important speed dialling options e.g.
  • Page 16 824, Switch 2 delay, defining the shortest delay time possible (1second) and a sufficiently long switch activation time. • Can I use the code lock while another person is speaking through EntryCom? Yes but this is not advisable as you should be aware that the password is private and could contravene security.
  • Page 17 ENTRYCOM Statuses and Available Operations Operation --- --- Button pressing – new call Call extension - DTMF Call termination - DTMF Hang-up upon continuous, busy or ringing tone Switch activation – DTMF password Programming start --- --- Switch activation – code lock...
  • Page 18: Installation Instructions

    Mechanical Mounting 6.2. Mounting Options What You Need for Mounting ® - 2N EntryCom only Indoor wall mounting ® EntryCom 1-module flush mounting box with Indoor frame, Part No. 9135351E, or...
  • Page 19 4. If you are utilising a roof module, you should install it now. 5. Screw EntryCom onto the wall. Carry the supply cables (line, lock, power supply) through one of the holes into the basic unit frame. Silicone 6.
  • Page 20: Buttons Labels - Insertion, Replacement

    Buttons Labels – Insertion, Replacement 6.3. Instructions 1. Remove the EntryCom metal cover. To do this, use a hexagonal key, unscrew the screw as shown in the figure and take the cover off. 2. Remove the name plates as shown in the figure using, e.g., a screw driver.
  • Page 21: Electrical Installation

    Connection to Telephone Line Connect EntryCom simply using LINE terminals. The advantage is that the EntryCom requires no power supply because all power is fed from the telephone line – except for the button backlight and electric lock, if connected. Nevertheless, EntryCom...
  • Page 23: Common Instalation

    It carries unnecessary risks to connect the unit in this way. It is in no case recommended to connect EntryCom in parallel to another telephone or another EntryCom door communicator. It is neither admissible to use equipment that switches one line between two or more sets (intelligent double branch, etc.).
  • Page 24 If a standard 12 V electric lock (see above) is connected to EntryCom, the backlight can be powered using the lock power supply. Connect the power supply as shown in the figure.
  • Page 25 We recommend you to use a UTP cable (8-wire, approx. 5.5 mm output diameter) for EntryCom connection. Push the cable into the groove on the left side of the cover. If you combine this cable with another one (e.g. the electric lock 2-wire cable), insert the 2-wire first and then the UTP cable to prevent the 2-wire cable from falling out.
  • Page 26 Connection of Switch 2 A new additional switch, Part No. 9135250E, has been designed for EntryCom. It can be mounted into any basic unit, as an added option. To connect it, follow the instructions included in the switch delivery.
  • Page 27: Camera Installation

    Camera Installation 7.2. The camera unit, Part No. 9135210E, can be built into any EntryCom basic unit during installation or as an option to be added later. You can also use the camera unit in combination with any Vandal resistant panel. It is a colour CCD camera with high resolution of 420 TV rows, with a monochrome night mode (infrared backlight hidden under the nameplates), and has a wide-angle pin-hole lens (90º...
  • Page 28: Connection Of Extender Units

    The easy installation of the button extender units is one of the great advantages of using the EntryCom system. The installation could not be easier - the units are connected using one cable (included in every extender delivery) in a chain manner (every element in the chain is connected with the preceding one).
  • Page 29 Cable Interconnection of Units • Every extender unit delivery contains a connecting cable with identical ends. The connection ratio is 1:1. It is impossible to insert the connectors incorrectly because they are provided with a key. • The basic unit is always on the left. The extender units are “chained“, each unit being connected with its neighbour.
  • Page 30 Button Numbering Button numbering – single-button sets Same Numbering Plan if the unit has a keypad Button numbering – double-button sets 15 23 31 39 16 24 32 40 17 25 33 41 18 26 34 42 19 27 35 43 Same 20 28 36 44...
  • Page 31: Programming

    • If you enter an incorrect function number or parameter value, EntryCom sends a refusal signal and you have to start with the function number again. • If you do not press any button within a predefined timeout, EntryCom sends a hang- up signal and hangs up. The timeout is 5 seconds; every character is followed by 30 seconds for you to think over your setting.
  • Page 32 • Should you use such confusing passwords for switch control, you have to enter the longer password (by phone) with asterisks at the beginning and end. • If EntryCom refuses to store a password, it means that the switch password list is full, or the password has already been entered.
  • Page 34: F U L L P A R A M E T E R C H A R

    2 = silent with confirmation Number Dialling for all 3 = SP without confirmation type buttons 4 = SP without confirmation The called party recognises better that the incoming call is Ticking into call 0-12 0 = off from EntryCom...
  • Page 35 15 = Maximum loudspeaker volume volume Minimum conti- If the tone is longer, 10 - 99 20 = 2s nuous tone time EntryCom hangs up. Minimum busy tone 0-255 8 = 0.08s period These parameters control the Maximum busy tone 0-255 70 = 0.7s...
  • Page 36 Parameter Parameter Name Range Default Note Possibility to hang up 0 = no by pressing the same 1 = yes button Possibility to dial the 0 = no next number by pressing another 1 = yes button Possibility to hang 0 = no up by pressing # 1 = yes...
  • Page 37 Increase parameter 944 also when Hélios is placed in the hall or corridor with a large decay time. Account of parameters 951, 952, 953 Ringing tone (example) At this time EntryCom detects, that ringing tone had ended. Long space Ringing tone Param.
  • Page 38: 1 . S E C T I O N F O R A D Va N C E D U Sers

    Automatic Multiple Number Dialling 11.1. When you press a EntryCom button, you may find out that the called line is busy or the called party is absent. EntryCom is able to identify these situations and solve them by Automatic Multiple Number Dialling if one of three automatic dialling modes is enabled.
  • Page 39 If the called number is busy or remains unanswered until the preset timeout or in other cases (see the table), EntryCom dials the next number in the sequence. Evaluation of Situations in Speakerphone Automatic Dialling with Confirmation...
  • Page 40 PSTN connection. Excessive noise in the surroundings may also have a negative impact. However, this may only decelerate automatic dialling (the busy tone may not be recognised, e.g.). Even if EntryCom cannot identify the DTMF, the connection is established (yet for a shorter time).
  • Page 41: Arrival/Departure, Day/Night Modes

    Arrival/Departure, Day/Night Modes 11.2. EntryCom can identify easily where to “route” (switch) a call after a button is pressed. All you have to do is call EntryCom and enter the following: I‘m leaving: password I‘m back: password All buttons can be switched all at once by a common Day/Night password or individually by separate Departure/Arrival passwords.
  • Page 42: Telephone Parameters

    12. Technical Parameters Telephone Parameters 12.1. Value Conditions Parameter Minimum required off-hook line current 15 mA Off-hook Minimum required on-hook line voltage 20 V Hang-up DC voltage drop (off-hook) < 8 V I = 25 mA < 16 V I = 50 mA Lead current while hang-up <...
  • Page 44 2N TELEKOMUNIKACE a.s. Modřanská 621, 143 01 Praha 4, PRAGUE: tel.: +420 261 301 333, fax: +420 261 301 999, e-mail: sales@2n.cz, www.2n.cz © 2007, 2N TELEKOMUNIKACE a.s.. - Prague DR 1322v2.0...

This manual is also suitable for:

Neowave entrycom

Table of Contents