Page 1
Introduction Safety notes Description of the device SIMATIC NET Assembling Network components Transceiver SFP/SFP+/SCP/STP Uninstalling Connecting up Operating Instructions Maintenance and cleaning Technical data Dimension drawings Approvals 10/2023 A5E02630804-18...
Page 2
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Table of contents Introduction ............................5 Safety notes ............................9 Description of the device ........................11 Product overview ....................... 12 Components of the product ....................15 Assembling ............................17 Safety notices for installation ..................... 17 Notes on installation of SFP / SFP+ transceivers..............18 Using a pluggable transceiver (SFP/SFP+)................
• On the data medium that ships with some products: – Product CD / product DVD – SIMATIC NET Manual Collection • On the Internet pages of Siemens Industry Online Support: – Industrial Ethernet / PROFINET Industrial Ethernet System Manual (https:// support.industry.siemens.com/cs/ww/es/view/27069465)
Page 6
Feed under https://www.siemens.com/industrialsecurity (https://www.siemens.com/industrialsecurity) Catalogs You will find the article numbers for the Siemens products of relevance here in the following catalogs: • SIMATIC NET Industrial Communication / Industrial Identification, catalog IK PI • SIMATIC Products for Totally Integrated Automation and Micro Automation, catalog ST 70 •...
Page 7
Introduction Device defective If a fault develops, send the device to your SIEMENS representative for repair. Repairs on-site are not possible. Recycling and disposal The products are low in pollutants, can be recycled and meet the requirements of the WEEE directive 2012/19/EU for the disposal of electrical and electronic equipment.
Safety notes Read the safety notices Note the following safety notices. These relate to the entire working life of the device. You should also read the safety notices relating to handling in the individual sections, particularly in the sections "Installation" and "Connecting up". CAUTION To prevent injury and damage, read the manual before using the device.
Description of the device Structure of the type designation The type designation of an pluggable transceiver is made up of several parts that have the following meaning: Standard version (C) Conformal coating Interface Number of ports 1 100 Mbps 2 1000 Mbps 3 10 Gbps SF Pluggable transceiver with LC connector SC Pluggable transceiver with SC connector...
Description of the device 3.1 Product overview Interface *) Property 1000 Mbps, LC port optical, glass FO cable (single mode), up to max. 40 km 10 Gbps, LC port optical, glass FO cable (single mode), up to 40 km 100 Mbps, LC port optical, glass FO cable (single mode), up to max. 70 km 1000 Mbps, LC port optical, glass FO cable (single mode), up to max.
Page 13
Description of the device 3.1 Product overview Active plug-in transceiver SFP (100 Mbps) With active plug-in transceivers, Gigabit slots can be used as Fast Ethernet interfaces. Type Property Article number SFP991-1A 1 x 100 Mbps, LC port optical for glass FO cable 6GK5 991-1AD00-8GA0 (multimode), up to max.
Page 14
Description of the device 3.1 Product overview Bidirectional plug-in transceiver SFP Bidirectional plug-in transceivers feature only one fiber connection. They transmit and receive on two different wavelengths. To establish a connection, you need two matching bidirectional SFPs. The connected SFPs must respectively transmit on the wavelength at which the connection partner receives.
Description of the device 3.2 Components of the product SCP / STP transceiver Type Properties Article number SCP992-1 1 x 1000 Mbps SC port optical for glass FO cable 6GK5 992-1AJ00-8AA0 (multimode) up to max. 750 m SCP992-1LD 1 x 1000 Mbps SC port optical for glass FO cable 6GK5 992-1AK00-8AA0 (single mode) up to max.
Page 16
Description of the device 3.2 Components of the product Transceiver SFP/SFP+/SCP/STP Operating Instructions, 10/2023, A5E02630804-18...
Assembling Safety notices for installation Safety notices When installing the device, keep to the safety notices listed below. NOTICE Improper mounting Improper mounting may damage the device or impair its operation. • Before mounting the device, always ensure that there is no visible damage to the device. Note The plug-in transceivers are only developed for a limited number of plug-in cycles.
General notes on media modules and pluggable transceivers NOTICE Use only approved pluggable transceivers If you use components not approved by Siemens AG, in particular SFP / SFP+ transceivers, Siemens cannot accept any responsibility for the correct functioning of the "Ethernet switch system" according to the specification.
Notes on SCALANCE W: Note With a SCALANCE W786-2, do not plug or pull an SFP transceiver during operation! If you have questions on the use of SIMATIC NET products, please contact your Siemens sales partner. Using a pluggable transceiver (SFP/SFP+)
General notes on pluggable transceivers NOTICE Use only approved pluggable transceivers If you use components not approved by Siemens AG, in particular SCP / STP transceivers, Siemens cannot accept any responsibility for the correct functioning of the "Ethernet switch system" according to the specification.
Plugging and pulling during operation The pluggable transceivers can be plugged and pulled during operation. If you have questions on the use of SIMATIC NET products, please contact your Siemens sales partner. Note SCP / STP transceivers can only be used in the SCP / STP slots of the SCALANCE XM408-4C.
Page 22
Assembling 4.5 Using a pluggable transceiver (SCP/STP) Figure 4-2 Plugging in a transceiver Follow the steps below to insert a pluggable transceiver: 1. Make sure that the package is complete (Page 15). 2. Check all the parts for transport damage. WARNING Do not use any parts that show evidence of damage If you use damaged parts, there is no guarantee that the device will function according to the specifications.
Page 23
Assembling 4.5 Using a pluggable transceiver (SCP/STP) 6. Remove the sealing plug of the plug-in transceiver. 7. Insert the connecting cable into the pluggable transceiver until you hear it engage. The connecting cable is then firmly secured. Transceiver SFP/SFP+/SCP/STP Operating Instructions, 10/2023, A5E02630804-18...
Page 24
Assembling 4.5 Using a pluggable transceiver (SCP/STP) Transceiver SFP/SFP+/SCP/STP Operating Instructions, 10/2023, A5E02630804-18...
Uninstalling WARNING Improper disassembly Improper disassembly may result in a risk of explosion in hazardous areas. For proper disassembly, observe the following: • Before starting work, ensure that the electricity is switched off. • Secure remaining connections so that no damage can occur as a result of disassembly if the system is accidentally started up.
Uninstalling 5.2 Removing a pluggable transceiver (SCP/STP) Removing a pluggable transceiver (SCP/STP) Notes on deinstallation CAUTION Risk of burns due to the high temperatures of the pluggable transceiver The pluggable transceivers can be plugged and pulled during operation. Leave the transceiver to cool down.
Page 27
Uninstalling 5.2 Removing a pluggable transceiver (SCP/STP) 3. Remove the pluggable transceiver from the pluggable transceiver slot. Note Do not use force It must be possible to remove the pluggable transceiver easily and without applying any force. 4. Fit a sealing plug to the pluggable transceiver. Transceiver SFP/SFP+/SCP/STP Operating Instructions, 10/2023, A5E02630804-18...
Connecting up Safety when connecting up Safety notices When connecting up the device, keep to the safety notices listed below. Safety notices on use in hazardous areas General safety notices relating to protection against explosion WARNING EXPLOSION HAZARD Do not connect or disconnect cables to or from the device when a flammable or combustible atmosphere is present.
Page 30
Connecting up 6.1 Safety when connecting up Further notes NOTICE Note the fiber type and the shape of the fiber end Note the following when setting up an optical connection: • Use the correct fiber type: – Multimode – Single mode •...
Connecting up 6.2 Power supply Note Commissioning devices with redundancy mechanisms If you use redundancy mechanisms ("HRP" media redundancy or "MRP" and/or redundant linking of rings via standby link), open the redundant path before you insert a new or replacement device in an operational network. A bad configuration or attachment of the Ethernet cables to incorrectly configured ports causes overload in the network and a breakdown in communication.
Page 32
Connecting up 6.2 Power supply Transceiver SFP/SFP+/SCP/STP Operating Instructions, 10/2023, A5E02630804-18...
Maintenance and cleaning WARNING Unauthorized repair of devices in explosion-proof design Risk of explosion in hazardous areas • Repair work may only be performed by personnel authorized by Siemens. WARNING Impermissible accessories and spare parts Risk of explosion in hazardous areas •...
Technical data Note Deviations of the technical specifications from the values displayed in the WBM The values displayed can vary from the values displayed in the WBM (menu "System > Port diagnostics", "SFP diagnostics" tab). The values stated and explained in this document are authoritative.
Technical data 8.1 SFP transceiver *) Depending on the cable used, you can find additional information in the "Industrial Ethernet / PROFINET Passive network components" System Manual, see also section "Introduction", paragraph "Additional documentation". 8.1.3 SFP991-1LD/SFP991-1LD(C) Properties Transmission mode 100Base-LX complying with IEEE 802.3 Transmission rate ...
Technical data 8.1 SFP transceiver Properties Cable length (max.) * 10 km Transmitter output (optical) Minimum -9.5 dBm Maximum -3 dBm Receiver input Sensitivity min. -19 dBm Input power max. -3 dBm Depending on the cable used, you can find additional information in the "Industrial Ethernet / PROFINET Passive network components"...
Technical data 8.1 SFP transceiver Properties Receiver input Sensitivity min. -23 dBm Input power max. -3 dBm Depending on the cable used, you can find additional information in the "Industrial Ethernet / PROFINET Passive network components" System Manual, see also section "Introduction", paragraph "Additional documentation".
Technical data 8.2 Bidirectional plug-in transceiver SFP Properties Transmitter output (optical) Minimum -10 dBm Maximum -4 dBm Receiver input Sensitivity min. -17 dBm Input power max. -3 dBm Depending on the cable used, you can find additional information in the "Industrial Ethernet / PROFINET Passive network components"...
Technical data 8.3 SFP+ transceiver Properties Receiver input Sensitivity min. -21 dBm Input power max. -3 dBm Depending on the cable used, you can find additional information in the "Industrial Ethernet / PROFINET Passive network components" System Manual, see also section "Introduction", paragraph "Additional documentation".
Technical data 8.5 STP transceiver Properties Receiver input Sensitivity min. -19 dBm Input power max. -3 dBm Depending on the cable used, you can find additional information in the "Industrial Ethernet / PROFINET Passive network components" System Manual, see also section "Introduction", paragraph "Additional documentation".
Technical data 8.8 Environmental conditions Construction Construction SFP/SFP+ Dimensions (W x H x D) 14 x 9 x 57 mm Weight 20 g SCP/STP Dimensions (W x H x D) 28 x 9 x 57 mm Weight 60 g Environmental conditions Environmental conditions Transportation/storage temperature -40 to +85 °C...
Technical data 8.9 Effective power loss Effective power loss Effective power loss at 25 °C ambient temperature SFP991-1/SFP991-1(C) 0.36 W SFP991-1A 1.1 W SFP991-1LD/SFP991-1LD(C) 0.39 W SFP991-1LD A 1.1 W SFP991-1LH+ 0.47 W SFP991-1ELH200 0.63 W SFP992-1/SFP992-1(C) 0.33 W SFP992-1+ 0.52 W SFP992-1LD/SFP992-1LD(C) 0.41 W SFP992-1LD+...
Technical data 8.10 MTBF (Mean Time Between Failure) 8.10 MTBF (Mean Time Between Failure) MTBF SFP991-1/SFP991-1(C) > 490 years SFP991-1A > 345 years SFP991-1LD/SFP991-1LD(C) > 490 years SFP991-1LD A > 370 years SFP991-1LH+ > 420 years SFP991-1ELH200 > 380 years SFP992-1/SFP992-1(C) > 670 years SFP992-1+ > 227 years SFP992-1LD/SFP992-1LD(C) >...
Page 52
Technical data 8.10 MTBF (Mean Time Between Failure) Transceiver SFP/SFP+/SCP/STP Operating Instructions, 10/2023, A5E02630804-18...
Dimension drawings SFP dimension drawing Front and top view, side view (left/right) and view from below Dimensions are specified in mm. Transceiver SFP/SFP+/SCP/STP Operating Instructions, 10/2023, A5E02630804-18...
Dimension drawings 9.2 SFP+ dimension drawing SFP+ dimension drawing Front and top view, side view (left/right) and view from below Dimensions are specified in mm. Transceiver SFP/SFP+/SCP/STP Operating Instructions, 10/2023, A5E02630804-18...
Dimension drawings 9.3 SCP dimension drawing SCP dimension drawing Front and top view, side view (left/right) and view from below Dimensions are specified in mm. Transceiver SFP/SFP+/SCP/STP Operating Instructions, 10/2023, A5E02630804-18...
Dimension drawings 9.4 STP dimension drawing STP dimension drawing Front and top view, side view (left/right) and view from below Dimensions are specified in mm. Transceiver SFP/SFP+/SCP/STP Operating Instructions, 10/2023, A5E02630804-18...
Current approvals on the Internet You will find the current approvals for the product on the Internet pages of Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/15273/cert). Notes for the manufacturers of machines This product is not a machine in the sense of the EC Machinery Directive or the Supply of Machinery (Safety) Regulations (UK).
Page 58
EC L174, 01/07/2011, pages 88-110 You will find the EU Declaration of Conformity/manufacturer's declaration for these products on the Internet pages of Siemens Industry Online Support (https:// support.industry.siemens.com/cs/ww/en/ps/15273/cert).
Page 59
"SIMATIC NET Product Information Use of subassemblies/modules in a Zone 2 Hazardous Area". You will find this document • on the data medium that ships with some devices. • on the Internet pages under Siemens Industry Online Support (https:// support.industry.siemens.com/cs/ww/en/ps/15273/cert).
Page 60
Approvals The products meet the requirements of the following standards: • EN/IEC 60079-7, GB 3836.8 • EN IEC/IEC 60079-0, GB 3836.1 You will find the current versions of the standards in the currently valid certificates. Note for devices with CLASS 1 LASER Important note on products certified according to Type Examination Certificate DEKRA 18ATEX0078 U and IECEx Certificate of Conformity DEK 18.0050 U and containing Class 1 optical radiation sources.
Page 61
Approvals Note The transceivers do not have a UL listing but a c-UR-us approval (component approval). Note for Australia - RCM The product meets the requirements of the RCM standard. Applied standards: • AS/NZS CISPR11 (Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement).