Page 1
• The appearance of a unit may be subject to change. • Save the manual and the proof of purchase for easy future reference. • Haier pharmaceutical refrigerators are for storage medicines and laboratory products at a temperature range of 2 to 8 C.
Safety Precautions Dear Customers, Thank you for choosing Haier pharmaceutical refrigerators. Before using the equipment, we advise that you carefully read and understood the contents and signs in this manual. This is to ensure your safety and prevent potential damage to stored products and the refrigerator.
Page 4
In case of flammable gas leakage such as coal gas, shut off the valve of leaked gas, open windows for ventilation and exhaust; do not plug in or pull out the power plug of refrigerator to prevent explosion and fi re. The refrigerator shall be installed by professional technical staffs or after-sale maintenance staff...
Page 5
The refrigerator shall be used in safe regions when toxic, harmful or radioactive articles are stored inside, as improper use may pose danger to human health or environment. Pull out the power plug if the refrigerator has been out of service for long time to prevent electric shock, leakage or fi...
Page 6
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualifi ed persons in order to avoid a hazard. Keep ventilation openings, in the appliance enclosure or in the built-in structure, clear of obstruction.
Usage Precautions • Make sure the temperature inside the refrigerator has reached the set value and put articles in the refrigerator by batch. Volumes accounted by articles shall not be greater than 1/3 of refrigerator to prevent rise of temperature. •...
Page 8
Product Features This product is designed to store biological and biomedical products at a temperature of 2 to 8 C. Typical installation sites include pharmacy stores, pharmaceutical factories, quarantine stations, health centers, and hospitals. 1. Temperature Control • The system's temperature is managed by a microcomputer. Temperature increment for adjustment is 0.1 C.
Product Installation Installation Environment • Ambient temperature: 16℃ to 35℃ ; optimal range is 16℃ to 25℃ • Humidity: below 85%Rh • Avoid excessive dust. • Solid and stable ground • Installation altitude lower than 2000m. • Voltage: nominal voltage ±10%. •...
Page 10
•After unpacking, use the casters of the refrigerator to handle the refrigerator. •When handling the refrigerator, the titling angle shall not be more than 45°. 2. Check the accessories shipped with the unit against the packing list. Contact Haier service should there be a discrepancy.
Page 11
5.Standing After leveling and cleaning the machine body, do not power on the refrigerator immediately. Allow the refrigerator to stand for more than 24 hours, and then power it on to ensure that it can operate normally. 6.Installation shelf and price tag Insert the shelf into the slot of the inner tank according to the appropriate distance and height.
Page 12
Initial Power-on Follow the rules below to start up a refrigerator. Connect the power cord to a dedicated socket that matches the electrical requirement for the unit. The unit should be without any load. Switch on the refrigerator and turn on the power switch on the electric control box on the right side of it.
Page 13
• This unit is designed for storage of products at 2 C to 8 C. Please make sure the temperature range meets the required storage temperature for your products. • The refrigeration process may cause a slight discrepancy between the displayed temperature and the air temperature inside the unit.
Application method Temperature Controller The temperature displayed represents the temperature sensed by the monitoring Warning bottle. The temperature shown is not always at 5 ℃ . The temperature sensor represents the average temperature in the storage box. When the accumulated start-up time of the compressor reaches a certain value (8 hours by default), the machine will automatically enter the forced defrosting cycle.
Page 17
Power failure alarm function When the power is down, power-off alarm function is activated, buzzer with 1 Hz frequency continuously beeps,at the same time alarm indicator light of the board fl ashes, if alarm equipment is connected to the remote alarm port, it will alarm synchronously and last at least 24 hours. Press the "Alarm"...
Page 18
USB(Optional) • USB interface function: The computer board has USB output function, which can export the temperature and other test data by U disk. The computer board can automatically collect and store temperature and other test data. The data is collected every 6 minutes and automatically saved after collection. When the data storage is full, the latest storage data will automatically replace the earliest storage space.
Alarm Alarm function This refrigerator has the alarm function in the table below, and also has a self-diagnosis function. Alarm Code Means Alarm mode High temperature Temperature sensor over limit Beep + alarm light fl ashing + Remote alarm Low temperature Temperature sensor over limit Beep + alarm light fl...
Page 20
•If the condition that caused the alarm within 30 minutes is not corrected, the buzzer Warning and remote control contacts will be triggered again. •In the event of a power failure, a fully charged backup battery can keep the alarm function working for 24 hours.
Cleaning and Maintenance • To avoid electric shock or injuries, please switch off the power of the refrigerator Warning before conducting any service or maintenance. • Do not inhale any air borne particles when conducting maintenance on your refrigerator. Refrigerator cleaning 1.Clean the refrigerator once a month.
Rechargeable battery recycling The refrigerator has a built-in rechargeable battery, which is recyclable. When the battery reaches the end of its service life, please contact the relevant local battery recycling agency to check or dispose of the battery correctly. Location of the battery The battery is used for power failure alarm, and the location of the battery is in the cabin above the box.
This chapter is to give answers in respect of potential fault phenomenon as well as respective solutions.If your question is still unresolved after operation, please contact Haier after-sales service.Do not maintain and dismantle the refrigerator by yourself!
Specifi cation • Packing List Specifi cation Name Pharmaceutical refrigerator Pharmaceutical refrigerator Model HYC-85GD HYC-85FD Exterior Dimensions 495×550×740 495×550×740 (W×D×H) (mm) Interior Dimensions 405×405×555 405×405×555 (W×D×H) (mm) Eff ective volume Inner temperature(℃ ) Door Glass door Solid door Insulation material...
Page 27
Accessory Packing List HYC-85GD HYC-85FD Name Operation manual Factory inspection report Performance test report Shelves/Baskets Power cord Kits Global Warming Potential Model Rated voltage(VAC) Rated frequency (Hz) equivalent(Tonnes) HYC-85GD 220-240~ 0.0009 HYC-85FD 220-240~ 0.0009 This product contains fl uorinated greenhouse gases covered by the Kyoto Protocol. Do not vent into the atmosphere.
Page 28
Certi cate of Quality checker: Manufacturer: Qingdao Haier Biomedical Co., Ltd. Address: Haier Industrial Park, Economic Technology Development Zone, Qingdao P.R. China Web:www.haiermedical.com Revision Date:03/2023 Version:1st,2023 Haier Biomedical Dedicated code:0270500000 Makes Life Better V13026...