Accessories
The following accessories are supplied with the indoor unit.
The type and quantity may differ depending on the specifications.
Pattern sheet
Rubber
Bushing bracket
Selecting the Installation Location
Indoor Unit
There must be no obstacles near the air inlet and outlet.
Install the indoor unit on a ceiling that can support its weight.
Maintain sufficient clearance around the indoor unit.
Make sure that the water dripping from the drain hose runs away
correctly and safely.
The indoor unit must be installed in this way, that they are out of public
access. (Not touchable by the users)
Rigid wall without vibration.
Where it is not exposed to direct sunshine.
Where the air filter can be removed and cleaned easily.
As a rule, the unit cannot be installed at a height of less than 2.5 m(8.2 ft).
It is possible to install the unit at a height of between 2.2 ~2.5 m (7.2~8.2 ft)
from the ground, if the unit has a duct with a well defined length [300 mm
(11.8 inch) or more] to avoid fan motor blower contact.
If you install the cassette or duct type indoor unit on the ceiling with
humidity over 80%, you must apply extra 10mm(0.39 inch) of polyeth-
ylene foam or other insulation with similar material on the body of the
indoor unit.
Insulation drain
Insulation cover band
Installation manual
Reducer
Flexible hose