Summary of Contents for Samsung SINGLE AC N Series
Page 1
SINGLE Technical Data Book SINGLE for Europe (R32, Heat Pump) CAC Utedel Digital Inverter Model : AC****N**KG/EU (Indoor Unit), AC***RXADK*G/EU (Outdoor Unit)
European Union (EU) regulations for more efficient performance. Non-inverter Small package, big performance The Samsung Ceiling Type air conditioner boasts a slim, compact design—half the size of conventional products— Saving with cooling power comparable to larger units. (Wh/h)
Page 3
Versatile piping installation allowance and control CAC Single outdoor units offer a selection of pipe Samsung is dedicated to supporting comfortable living directions. The internal pipe connection ports allow four different pipe directions, supporting a neater, more and working environments based on the strength of organized-looking unit upon installation.
Page 4
Nomenclature Outdoor Unit Model Name Buyer (1) Classification (5) Product Notation A, 1 Inv+Side+General Temp (6) Feature (2) Capacity Flagship X 1/10 kW (3 digits) Standard Deluxe Premium (3) Version 2018 (7) Rating Voltage 2019 1Ф, 220~240V, 50Hz 3Ф, 380~415V, 50Hz (4) Product Type Indoor Unit (8) Mode...
Page 5
Line-up Outdoor Unit Capacity (kW) Model 5.2 (5.0) 10.0 (9.5) 12.0 13.4 1Phase 3Phase...
2. Dimensional Drawing Outdoor Units AC052RXADKG/EU Units : mm [inches] Name Description Refrigerant gas pipe Φ12.7(1/2) Refrigerant liquid pipe Φ6.35(1/4) Drain Hole Φ20...
Page 10
2. Dimensional Drawing Outdoor Units AC071RXADKG/EU Units : mm [inches] Name Description Refrigerant gas pipe Φ15.88(5/8) Refrigerant liquid pipe Φ6.35(1/4) Drain Hole Connection with the provided drain plug.
Page 11
2. Dimensional Drawing Outdoor Units AC100/120RXAD*G/EU Units : mm [inches] [37] [63/64] [22-51/64] [12-5/16] [2-1/16] [1-3/16] [1-21/32] [3-1/8] [1-3/16] [3-5/64] [4-3/16] [3-1/2] [5-15/64] [2-5/8] [6-1/32] [7/8] [6-1/2] [24-3/8] [2-3/8] [11/16] [1-3/16] [1-7/16] Hole For Anchor Bolt (4Positions , M10) [11-9/16] [8-9/16] Name Description...
3. Center of Gravity 3. Center of Gravity Outdoor Units AC026/035RXADKG/EU Units : mm [inches] [9-1/8 [6-1/2] The position of foundation bolt AC052RXADKG/EU Units : mm [inches]...
Page 14
3. Center of Gravity Outdoor Units AC071RXADKG/EU Units : mm [inches] AC100/120RXAD*G/EU Units : mm [inches]...
Page 15
3. Center of Gravity Outdoor Units AC140RXAD*G/EU Units : mm [inches]...
5. Sound Data 5. Sound Data Outdoor Units Sound Pressure level Unit: dB(A) Model Cooling Heating Microphone AC026RXADKG/EU AC035RXADKG/EU AC052RXADKG/EU 1.5m AC071RXADKG/EU Front • NR Curve 1) AC026RXADKG/EU 2) AC035RXADKG/EU NR 90 NR 90 NR 85 NR 85 NR 80 NR 80 NR 75 NR 75...
Page 21
5. Sound Data Outdoor Units Sound Pressure level Unit: dB(A) Model Cooling Heating Microphone Microphone AC100RXAD*G/EU AC120RXAD*G/EU AC140RXAD*G/EU 1.5m 1.5m Front Front • NR Curve 5) AC100RXAD*G/EU 6) AC120RXAD*G/EU NR 75 NR 75 NR 70 NR 70 Heating Cooling NR 65 NR 65 Heating Cooling...
5. Sound Data Outdoor Units Sound Power level Unit: dB(A) NOTE Model Power • Specifications may be subject to change without prior notice AC026RXADKG/EU - Sound power level is an absolute value that a sound source generates. AC035RXADKG/EU - dBA = A-weighted sound power level. AC052RXADKG/EU - Reference power : 1pW.
Page 23
5. Sound Data Outdoor Units Sound Power level Unit: dB(A) NOTE Model Power • Specifications may be subject to change without prior notice AC100RXAD*G/EU - Sound power level is an absolute value that a sound source generates. AC120RXAD*G/EU - dBA = A-weighted sound power level. AC140RXAD*G/EU - Reference power : 1pW.
7. Operation Range 7. Operation Range AC026/035RXADKG/EU Outdoor Unit Indoor Unit Indoor Unit Mode Temperature(DB) Temperature(DB) Humidity(RH) Cooling -15°C ~ 46°C 18°C ~ 32°C 80% or less Heating -20°C ~ 24°C 30°C or less Drying -15°C ~ 46°C 18°C ~ 32°C 80% or less AC052/071/100/120RXAD*G/EU Outdoor Unit...
※ In case you want more information about the controllers and accessories, please refer to the Controller and Accessory TDB on pvi.Samsung.com site or Global Partner Portal site.
Page 54
Outdoor Unit 200 mm CAUTION Air Guide Duct (This product is not provided by Samsung) • Depending on the condition of power supply, • Install the unit at a height where its base can be unstable power or voltage may cause malfunction firmly fixed in place.
2000 300 or 600 or or more more more AC071RXADKG or more ※ In case you want more information about the controllers and accessories, please refer to the Controller and Accessory TDB on pvi.Samsung.com site or Global Partner Portal site.
Page 56
The components of the outdoor unit must be reachable and removable under safe conditions for people and the unit. ※ In case you want more information about the controllers and accessories, please refer to the Controller and Accessory TDB on pvi.Samsung.com site or Global Partner Portal site.
- The air guide duct is fixed firmly on the guard fan. ※ In case you want more information about the controllers and accessories, please refer to the Controller and Accessory TDB on pvi.Samsung.com site or Global Partner Portal site.
Outdoor Unit Communication cable ELCB Earthing Main power cable Indoor Unit ※ In case you want more information about the controllers and accessories, please refer to the Controller and Accessory TDB on pvi.Samsung.com site or Global Partner Portal site.
• Keep distances of 50 mm or more between power cable and communication cable. ※ In case you want more information about the controllers and accessories, please refer to the Controller and Accessory TDB on pvi.Samsung.com site or Global Partner Portal site.
Page 60
18.1 20.6 AC071TNXDKG AC071RXADKG 220 to 240 16.5 16.5 17.7 17.7 20.6 ※ In case you want more information about the controllers and accessories, please refer to the Controller and Accessory TDB on pvi.Samsung.com site or Global Partner Portal site.
Page 61
M4 screw hole(NOT SUPPLIED WITH UNIT ACCESSORIES). ※ In case you want more information about the controllers and accessories, please refer to the Controller and Accessory TDB on pvi.Samsung.com site or Global Partner Portal site.
Page 62
• Keep distances of 50 mm or more between power cable and communication cable. ※ In case you want more information about the controllers and accessories, please refer to the Controller and Accessory TDB on pvi.Samsung.com site or Global Partner Portal site.
Page 63
40.0 AC140RXADKG 32.0 32.0 AC140RNMDKG 34.5 34.5 40.0 AC140RNCDKG 34.5 34.5 40.0 ※ In case you want more information about the controllers and accessories, please refer to the Controller and Accessory TDB on pvi.Samsung.com site or Global Partner Portal site.
Page 64
• Abbreviations MCA: Min. Circuit Amps. (A) MFA: Max. Fuse Amps. (A) ※ In case you want more information about the controllers and accessories, please refer to the Controller and Accessory TDB on pvi.Samsung.com site or Global Partner Portal site.
Page 65
1(L) 2(N) Cable tie Outdoor-to-indoor Main power cable Communication cable power cable ※ In case you want more information about the controllers and accessories, please refer to the Controller and Accessory TDB on pvi.Samsung.com site or Global Partner Portal site.
• When the cables are connected through the hole, remove the Plate bottom. ※ In case you want more information about the controllers and accessories, please refer to the Controller and Accessory TDB on pvi.Samsung.com site or Global Partner Portal site.
• Protect or enclose refrigerant tubing to avoid mechanical damage. ※ In case you want more information about the controllers and accessories, please refer to the Controller and Accessory TDB on pvi.Samsung.com site or Global Partner Portal site.
Page 68
Temper grade ø6.35 ø9.52 C1220T-O ø12.70 ø15.88 ø15.88 ø19.05 C1220T-1/2H OR C1220T-H ø22.23 ※ In case you want more information about the controllers and accessories, please refer to the Controller and Accessory TDB on pvi.Samsung.com site or Global Partner Portal site.
Page 69
• Make sure that the refrigeration system is earthed Liquid side stop valve before charging. (service port) ※ In case you want more information about the controllers and accessories, please refer to the Controller and Accessory TDB on pvi.Samsung.com site or Global Partner Portal site.
Page 70
Outdoor Unit AC100RXAD*G 2700 1000 3700 AC120RXAD*G AC140RXAD*G 2900 2250 5150 Unit tCO₂e ※ In case you want more information about the controllers and accessories, please refer to the Controller and Accessory TDB on pvi.Samsung.com site or Global Partner Portal site.
Page 71
+50 g/m over 30 m AC120RXAD*G AC140RXAD*G +50 g/m over 30 m ※ In case you want more information about the controllers and accessories, please refer to the Controller and Accessory TDB on pvi.Samsung.com site or Global Partner Portal site.
Page 72
AC052*N*DKG or three AC035*N*DKG is available. ※ In case you want more information about the controllers and accessories, please refer to the Controller and Accessory TDB on pvi.Samsung.com site or Global Partner Portal site.
Page 73
※ The wired remote controller can be used with any of 7-segment. the DPM indoor units. ※ In case you want more information about the controllers and accessories, please refer to the Controller and Accessory TDB on pvi.Samsung.com site or Global Partner Portal site.
Page 74
2020. 03 Ver.3.1 Samsung Electronics Co., LTD. Head Office (Suwon Korea) 129, Samsung-Ro, Yeongtong-Gu, Suwon City, Gyeonggi-Do, Korea 16677 Website : www.samsung.com, https://partnerhub.samsung.com Email : airconditioner@samsung.com Images and data in this book may subject to change without prior notice.