Advertisement
The Honeywell CM61 is a programmable thermostat which controls your heating system so that you can have comfortable temperatures when you are at home and energy savings when you are away.
It is important to understand that the CM61 is not a traditional "ON/OFF" controller but a "HI / LOW" temperature controller.
This means that to program the heating to go 'OFF' at a particular time a lower (setback) temperature setpoint is entered which you would choose to protect you and your home.
Attractive slim styling makes it ideal for location in any suitable room in your home.
Display Backlight illuminates the display when a key is pressed for easier viewing in low light conditions.
6 daily independent temperature levels let you set any 6 temperatures from 5 to 30°C to match your daily lifestyle.
Holiday button saves energy by letting you reduce the temperature for 1 to 99 days while you are on holiday, returning to normal operation on the day you return.
Memory holds the user program indefinitely so that it is never lost even if you take the batteries out.
Outside Temperature Sensor (optional accessory) can be fitted to the CM61 to display the outside temperature.
Remote Temperature Sensor (optional accessory) can be fitted to the CM61 to control the temperature from another room.
Optimum Start option is a program which ensures that the optimum temperature conditions are achieved at the required times as described below (not available on T6661B1040).
Optimum Start is an Energy Efficiency Feature that adjusts the start time of your heating system depending upon how cold it is.
On cold days your Heating will be started earlier to ensure that your home is warm when you get up and on warmer days the heating system will be started later to save energy.
So, if the Optimum Start Feature is used, the time / temperature settings which are entered into the CM61 are when you want to be warm by and not when you want the heating to start. (not available on T6661B1040)
The diagram below details the key button functions and display information.
The CM61 has a backlit display that will illuminate when a button is pressed for easier viewing of the display in low light conditions. After the last button press the backlight will remain on for 7 seconds.
The time can be set with the CM61 in the AUTO, MAN or OFF operating modes. Press + or - until the correct time is displayed. Each button press will change the time by one minute. Holding the button down for a few seconds will change the time slowly at first, then quickly. Make sure AM or PM is correct.
Press the AUTO button. The CM61 will now control your heating using the built-in temperature program:
Daily
Program | 1 | 2 | 3 | 4 | 5 | 6 |
Time | 6:30 | 8:00 | 12:00 | 2:00 | 6:00 | 10:30 |
Temperature | 21°C | 18°C | 21°C | 18°C | 21°C | 16°C |
Although the CM61 has up to 6 temperature / time changes available (PROG 1 – 6), any unused settings may be deleted by holding down the appropriate button (PROG 2 – 6) for 2 seconds.
To reinstate any deleted setting hold down the button again for 2 seconds.
When the CM61 is in AUTO mode (display will show "AUTO") the temperature can be adjusted temporarily by pressing TEMP or . The temperature will return to the program at the next temperature change time.
In normal operation the temperature displayed is the actual room temperature. To check the programmed temperature press and the display will show the programmed temperature with the two small arrows.
To operate as a simple thermostat with one temperature throughout the day, press MAN. Adjust the manual temperature by pressing TEMP or . The manual temperature can be set anywhere from 5°C to 30°C in 0.5°C steps.
The unit will control to the new temperature for the set number of days holiday. At midnight the holiday counter will be reduced by one until the selected number of days have passed. The unit will then return to normal control as set by the MAN or AUTO button.
To cancel the HOLIDAY setting, press the button a second time.
Press the OFF button. The unit has an intelligent built-in frost protection feature, so that if the temperature falls below 5°C, it will automatically switch the heating on.
With no other accessories fitted and for applications other than electric heating, the batteries should last about 4 years.
When the batteries need replacing, a flashing symbol will be displayed.
To change the batteries:
RESPECT YOUR ENVIRONMENT!
Take care to dispose of used batteries carefully.
NOTE: If you take more than one minute to change the batteries the clock may need to be reset - see How do I adjust the time?
Yes. Please refer to your installer for more information.
NOTE: This option only works if activated by your installer.
The 'SERVICE' indicator is displayed at set intervals as a reminder that your heating system requires a routine check. Please call your installer to arrange a maintenance visit.
The symbol will remain on the display of the CM61 until it is either reset or disabled by your installer. The CM61 and heating system will continue to operate as normal.
Honeywell provides other accessories and "Add-On" modules that can be used with your CM61, ask your installer for details:
The ATS module picks up a daily time signal from a transmitter in Central Europe and corrects the time on the CM61 display. So:
* Not available in all Geographic Regions depending on transmitter range and home location.
The Outside Temperature Sensor accessory can be fitted to your CM61 to display the outside temperature. By pressing the twice, the CM61 displays the external temperature.
The Remote Temperature Sensor accessory can be fitted to your CM61 to control the temperature of another room where it is inconvenient to locate the CM61 e.g. commercial premises where the public may adjust buttons.
See the troubleshooting guide below. If you need assistance after this, call your installer. The CM61 should only be opened or removed by a qualified professional to prevent possible injury from electric shock.
Symptom | Possible Cause | Remedy |
Blank Display | No batteries | Check batteries are in the battery compartment and that the paper tab has been pulled out |
Battery orientation | Check that the batteries have been installed in the correct orientation. | |
Exhausted batteries | Replace batteries | |
Incorrect battery cartridge insertion | Remove battery cartridge and re-insert | |
Display shows flashing symbol | Batteries need replacing | Change the batteries as described previously |
Display works but heating does not switch on | No power to system | Check that there is power to the system |
Program does not call for heat | Press TEMP to increase the temperature a few degrees above the current room temperature. The heating should come on after a few seconds. | |
CM61 not connected to boiler properly | Call installer to check electrical connection between the CM61 and the boiler | |
Heating switches ON/OFF too slowly or too quickly | CM61 not set correctly for your system | Call installer |
Temperature swings between too hot and too cold | CM61 not set correctly for your system | Call installer |
Display shows symbol | Fault in the CM61 | Remove battery cartridge and re-insert. If the symbol does not clear itself in a few minutes call the installer |
Display shows the word 'SERVICE' | Your installer has set a scheduled maintenance alert period on your CM61 as a recommendation that your heating system should receive a routine inspection. | Call your installer to arrange a maintenance visit. The CM61 and heating system will continue to operate as normal. |
This product and its associated documentation and packaging are protected by various intellectual property rights belonging to Honeywell Inc and its subsidiaries and existing under the laws of the UK and other countries. These intellectual and property rights may include patent applications, registered designs, unregistered designs, registered trade marks, unregistered trade marks and copyrights and also include the following UK registration rights:
UK patent application number 98062207.8
UK registered design numbers 2073334, 2073340 and 2073343.
Honeywell Control Systems Ltd.
Arlington Business Park
Bracknell, Berkshire RG12 1EB
User Help Line: 01344 656511
www.honeywelluk.com
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Advertisement
Thank you! Your question has been received!
Need Assistance?
Do you have a question about the CM61 that isn't answered in the manual? Leave your question here.