DC power cord for normal operation. 1.1 Safety precautions and • Please use approved power cord maintenance provided by Philips all the time. If your power cord is missing, please Warnings contact with your local service Use of controls, adjustments or center.
Page 4
1. Important • Do not knock or drop the monitor • Unplug the monitor if you are not during operation or transportation. going to use it for an extensive period of time. • Excessive usage of monitor can cause eye discomfort, it’s better to • Unplug the monitor if you need to take shorter breaks more often at clean it with a slightly damp cloth.
1. Important known as “after-imaging” or “ghost 1.2 Notational Descriptions imaging”, on your screen. The following subsections describe • “Burn-in”, “after-imaging”, or notational conventions used in this “ghost imaging” is a well-known document. phenomenon in LCD panel technology. In most cases, the Notes, Cautions and Warnings “burned in”...
From the planning, design and production stages, Philips emphasizes the important of making products that can easily be recycled. At Philips, end-of-life management primarily This marking on the product or on entails participation in national take-...
HDMI *Different according to region Step 1 Note Step 2 162B9TN: Use only the AC/DC adapter USB A-B model: Philips ADPC1936. 172B9TN: Use only the AC/DC adapter model: Philips ADPC2045. Kensington anti-theft lock DC power input Displayport input DVI input...
2. Setting up the monitor Connect to PC 2.2 Operating the monitor 1. Connect the power cord to the back Description of the control buttons of the monitor firmly. 2. Turn off your computer and unplug its power cable. 3. Connect the monitor signal cable to the video connector on the back of your computer.
Page 9
"ON" mode: it On-Screen Display (OSD) is a feature makes the screen looks slightly dim; for in all Philips LCD monitors. It allows an optimum brightness, enter to the OSD end user to adjust screen performance to set "DPS"...
2. Setting up the monitor Resolution notification 2.3 VESA Mounting This monitor is designed for optimal Note performance at its native resolution, This monitor accepts a 100mm x 100mm 1366 x 768(162B9TN), 1280 x VESA-Compliant mounting interface. 1024(172B9TN). When the monitor is VESA Mounting Screw M4.
How does it work? SmartImage is an exclusive, leading edge Philips technology that analyzes the content displayed on your screen. • EasyRead: Helps improve reading Based on a scenario you select, of text based application like PDF SmartImage dynamically enhances the ebooks.
3. Image Optimization • Photo: This profile combines color Note saturation, dynamic contrast and Philips LowBlue mode, mode 2 sharpness enhancement to display compliance with TUV Low Blue Light photos and other images with certification, you can have this mode by...
OS and applications which support functionality. touch functions, see the table listed above. • *Some operating systems require driver for the touch function. The driver is available from the Philips website supporting pages. HDMI Step 1 Step 2 USB A-B...
5.Technical Specifications 5. Technical Specifications Picture/Display Monitor Panel Type Backlight W-LED 162B9TN: 15.6" (39.6 cm) Panel Size 172B9TN: 17" (43.2 cm) 162B9TN: 16:9 Aspect Ratio 172B9TN: 4:3 162B9TN: 0.252 (H) mm x 0.252 (V) mm Pixel Pitch 172B9TN: 0.264 (H) mm x 0.264 (V) mm 162B9TN: 500:1 Contrast Ratio (typ.) 172B9TN: 1,000:1...
Page 15
5.Technical Specifications Connectivity Analog: VGA Signal Input/Output Digital: DVI-D, DP1.2, HDMI 1.4 USB3.1 x 2 including x 1 BC1.2 fast charger Input Signal Separate Sync, Sync on Green Audio In/Out PC audio-in, headphone out Convenience Built-in speaker 2 W x 2 User Convenience English, German, Spanish, Greek, French, Italian, Hungarian, Dutch, Portuguese, Brazil Portuguese,...
Page 16
100% PVC BFR free housing Cabinet Color Black Finish Texture Note 1. This data is subject to change without notice. Go to www.philips.com/support to download the latest version of leaflet. 2. *Some operating systems require driver for the touch function. The driver is avail-...
Page 17
5.Technical Specifications able from the Philips website supporting pages. 3. In order to comply with international energy standards, power consumptions are under the PC/Display test mode and the monitor needs to connect with USB up- stream cable.
6.Power Management The following setup is used to measure 6. Power Management power consumption on this monitor. • Native resolution: 1366 If you have VESA DPM compliance x 768(162B9TN), 1280 x display card or software installed in 1024(172B9TN), your PC, the monitor can automatically reduce its power consumption when • Contrast: 50% not in use.
Pixel Defect Policy single black pixel. Other combinations of lit and dark sub pixels appear as Philips strives to deliver the highest single pixels of other colors. quality products. We use some of the industry's most advanced...
Page 21
Black Dot Defects the warranty period, a TFT Monitor Black dot defects appear as pixels or panel in a Philips flat panel monitor sub pixels that are always dark or 'off'. must have pixel or sub pixel defects That is, a dark dot is a sub-pixel that...
Page 22
7.Customer care and warranty 162B9TN BRIGHT DOT DEFECTS ACCEPTABLE LEVEL 1 lit subpixel 1 or fewer 2 adjacent lit subpixels 3 adjacent lit subpixels (one white pixel) Distance between two bright dot defects* >5mm Total bright dot defects of all types 1 or fewer BLACK DOT DEFECTS ACCEPTABLE LEVEL...
Please contact our Philips Customer Service Representative or local contact center (by Consumer care number) for more details. Philips Customer Care Center number listed below.
Service contact information listed known as "after-imaging " or "ghost in Regulation & Service Information imaging", on your screen. "Burn-in", Manual and contact Philips customer "after-imaging", or "ghost imaging" service representative. is a well-known phenomenon in * Functionality different according to monitor panel technology.
Page 26
When handling the disconnect your old monitor and monitor, make sure that there is reconnect your Philips LCD monitor. no pressure or force applied to • Turn on your monitor and then turn the panel surface side. This may on your PC.
Page 27
“ghost image” symptoms any PC, workstation or Mac? that will not disappear and cannot be repaired. The damage mentioned above Ans.: Yes. All Philips LCD monitors are is not covered under your warranty. fully compatible with standard PCs, Macs and workstations. You...
Where can I find Regulation & Service Information Manual mentioned in EDFU? Ans.: Regulation & Service Information Manual can be download on the Philips website support page. 8.3 SmoothTouch Why is the touch function not available when I touch the dis- play? Ans.: Please ensure the supplied USB...
Page 29
This product has been manufactured by and is sold under the responsibility of Top Victory Investments Ltd., and Top Victory Investments Ltd. is the warrantor in relation to this product. Philips and the Philips Shield Emblem are regis- tered trademarks of Koninklijke Philips N.V. and are used under license.