hit counter code
2easy 2-wire Series Technical Manual

2easy 2-wire Series Technical Manual

Apartment intercom system 5-inch tft module
Hide thumbs Also See for 2-wire Series:

Advertisement

Quick Links

DT821 TECHNICAL MANUAL
Apartment Intercom System
2-wire Series
VULCAN 5-inch TFT Module

Advertisement

Table of Contents
loading

Summary of Contents for 2easy 2-wire Series

  • Page 1 DT821 TECHNICAL MANUAL Apartment Intercom System 2-wire Series VULCAN 5-inch TFT Module...
  • Page 2: Parts And Functions

    INSTALLATION GUIDE 1. Parts and Functions Speaker Fisheye Lens Night View LED Microphone 1 2 3 4 5 6 Status Indicator Connection Dot-matrix Display Port Card Reader MK Modul e Screw Hole Surface mount box Flush mount wall box Door Station...
  • Page 3: Terminal Description

    INSTALLATION GUIDE 2. Terminal Description JP-LK CN/KMB CN/T-COIL 1 2 3 4 5 6 CN/FUN CN/WGN • +12V: 12VDC power output • LK-: power ground • LK+: relay common contact • NO.: relay normally open contact • EB+: exit button positive • EB-: exit button negative • JP-LK: electronic lock type setting • SET : DIP switches for system configurations...
  • Page 4 INSTALLATION GUIDE Unlock timing: 1~99s Working temperature: - 20ºC ~ +55ºC Wiring: 2 wires (no-polarity) Dimension: H316×W133×D48mm(3-Modules) H232×W133×D48mm(2-Modules) 4. Mounting Flush mounting Use the screws to fasten the panel Cut a hole and install the wall box Final result Connect and plug bus line connector with cable Surface mounting...
  • Page 5: Connection Diagram

    INSTALLATION GUIDE 5. Connection Diagram Impedance Code=31 Code=30 OFF ON switch Code=29 Code=28 Code= 4 Code= 3 Impedance OFF ON switch Code= 2 Code= 1...
  • Page 6: Dip Switches Settings

    VD MODULE 6. VD Module Speaker Camera lens Night view LED Invisible key B Invisible key A Status indicator Talk indicator Unlock indicator Note: Key A and key B can not be seen on the panel, they are cryptic. Normally key A and key B are not active. To activate them, flip DIP switch 6 into On position (1) DIP Switches Settings There are 6 DIP- switches on the rear of door station.
  • Page 7 VD MODULE • Dip-4 is obsolete • DIP-5 is for unlocking time setting. Off (0) is default setting, and the default time is 1 second. If set On (1), the unlock time is 5 seconds • DIP-6 is for activating invisible key A and key B. Power Off the door station and then power it On.
  • Page 8 VD MODULE • Unlocking Time Setting 1. Press Key A, the Unlock indicator turns on with double beep sound 2. Press and hold Key B to enter the Unlocking Time Setting, single beep sound and the Status indicator start blinking one time per second. Every flash of Status Indicator increase unlocking time by 1 second For example, if Status indicator blinked four times, the unlocking time is 4 seconds...
  • Page 9 VD MODULE • Tune Volume Setting When the door station with Camera Module is in standby. (1)Press Key B to enter Tune Volume Setting, the Talk indicator turns on,at the same time, play the tune at current volume; (2)Press Key A to increase/decrease the volume; (3)Press B to exit.
  • Page 10 VD MODULE B). Please know that the Bit-6 switch must be set to ON, then power up to carry on the following settings. • Camera N / P Standard Switch When the door station with Camera Module is in standby. (1)Press Key A, the Talk indicator and Status indicator turns on with the warn- ing sound of BP+, BP;...
  • Page 11 T5 MODULE 7. T5 Module • About main menu: Press to enter se�ng page Keypad bu�on Unlock bu�on Namelist bu�on Help bu�on Calling a resident via input room number: Press keypad button to enter keypad page. Input the room number. Press to call.
  • Page 12 T5 MODULE Open the door by entering an unlock password: Press unlock button to enter keypad page. Input your unlock password. Press to open the door. Open the door by using an access card: Touch your access card to card reader area of the door station. -12-...
  • Page 13 T5 MODULE Enter installer mode: and input installer password into setting menu. Default installer password: 66666666 NOTICE: Installer mode will not exit until you manually exit or power off and restart. to exit installer mode. back to standard main menu. While in standard main menu, you could check as below: Exited installer mode Still in installer mode...
  • Page 14: Installer Menu

    T5 MODULE Installer menu: 1. Language Select language 2. Date & Time Setting up date and time 3. Menu style Select menu style, requires customizing 4. System settings Settings relates to DT821 Video module Video format PAL or NTSC, default is PAL Tone prompt Tone or prompt setup, 0: Mute, 1: Ringtone, 2: Voice Ennunciation Sound volume...
  • Page 15: Other Settings

    T5 MODULE Night LED level Night LED illumination level Night LED mode, “Auto” (detect each 10min), “Always On” and Night LED mode “Always Off” If surface mounted with raincover, enable it to have smaller Rain-cover enable camera angle 5. Other settings Settings related to T5 module Setting Item Description...
  • Page 16 T5 MODULE Setting Item Description Display unlock icon on the list calling menu Enable: Disable: List displays unlock Display name only or with a flat number List displays name only Screen mode “Day mode” (white background), or “Night mode” (black background) Screen bright TFT screen illumination level The maximum waiting timing to call without tap confirm (keypad...
  • Page 17: Installer Code

    T5 MODULE 6. Installer Code To change the installer code: Input default or current installer code -> Input new code twice Default installer code: 66666666 7. Unlocking Code Disable/Enable unlocking with a code To change public unlocking code: Input current public unlocking code -> input new code twice (4digits) Default public unlocking code: 1234 8.
  • Page 18 T5 MODULE Monitor connected Monitor not connected Remove or Enable monitors from Namelist By default, 32 monitors will be listed. To remove the monitor from the list please follow steps as below: IM Manage IM Manage IM Manage 1-16 17-32 1-16 17-32 1-16...
  • Page 19 T5 MODULE DT addr: current DT monitor address, is a read only info Manage PWD: manage password for this user, each user could get into their’s own setting menu by input manage password, input “Address” + “Manage password” to get into this menu, such as for 01 and manage PWD is 2234, input 12234 to get in to manage page.
  • Page 20 T5 MODULE View Cards View card Room Name Card ID Date Seach Tap “View Cards”, and in “View Cards” you could view registered cards: • Swipe the card needed to be checked • Input or select a room • Input card holder’s name •...
  • Page 21: Device Information

    T5 MODULE Card data Tap “Card data” Backup to SD: Backup card data to a SD card (the card slot in T5 module). Restore from SD: Restore a backup from SD card Clear RES Data: Delete all cards 10. Device information Show information: firmware version, up time (running since power up) and SN number 11.
  • Page 22: Specification

    13. Exit installer mode Exit installer mode 14. RES manage Uploads customize files (display language, default settings and Logo) RES manage does not manage “Voice prompt” Backup to SD Backup customized files onto SD card Restore form SD Restore customized files Clear customization Remove customization, roll back to standard version Specification:...
  • Page 23: Door Lock Controlled With Internal Power

    LOCK CONNECTION 14. Electric Lock Connection 1) Door Lock Controlled with Internal Power 1. The door lock is limited to 12Vdc, and holding current must be less than 250mA when using internal power 2. The Unlock Mode Parameter must be set to 0 (default) 3.
  • Page 24: Electric Lock Connection

    ELECTRIC LOCK CONNECTION 2) Door Lock Controlled with External Power 1. The external power supply must be used according to the lock 2. The jumper must be taken off before connecting 3. Setup the Unlock Mode Parameter for different lock types • Power-on-to-unlock type:Unlock Mode=0 (default) • Power-off-to-unlock type:Unlock Mode=1 4.
  • Page 25 DT-ENG-821-V1 The design and specifications can be changed without notice to the user. Right to inter- pret and copyright of this manual are preserved.

This manual is also suitable for:

Vulcan dt821