Page 1
Tel: 01452 733933 Fax 01452 733939 TIG 170 AC/DC DIGITAL TIG WELDER OPERATION INSTRUCTIONS Version 2017-10...
Page 3
Thank you for selecting the R-Tech POWER TIG 170EXT Digital Inverter AC/DC Tig Welder. The POWER TIG 170EXT Digital has many benefits over traditional TIG welders, including 9 memory stores, advanced AC waveforms, pulse welding, slope up/down, remote foot option and an industrial 60% duty cycle.
Page 4
Welding Capability – Duty Cycle The R-Tech POWER TIG 170EXT Digital is rated at 170 Amps at 60% duty cycle on a ten minute basis. If the duty cycle is exceeded a thermal protector will shut machine off until the machine cools.
Page 5
Pulse Amperage Range 5 - 95% Gas Post Flow Time 0 - 50 Seconds Gas Pre Flow Time 0 - 25 Seconds Arc Starting Mode High Frequency AC Waveforms Advanced Squarewave Soft Squarewave Triangular Sine Wave AC Balance Control 5 - 90% of Electrode Positive AC Easy Start Parameters AC Frequency 120Hz AC Balance 25%...
This machine cannot be stacked. Transport – Unloading Never underestimate the weight of equipment, never move or leave suspended in the air above people. Use recommended lifting equipment at all times. WARNING! Falling Equipment can cause injury. Never lift welder with gas bottle attached. Never lift above personnel.
Page 7
3. Direct interference radiated from feedback into power lines 4. Interference from re-radiation by un-grounded metallic objects. Keeping these contributing factors in mind, installing equipment as per following instructions should minimize problems. 1. Keep the welder input power lines as short as possible and enclose as much of them as possible in metal conduit or equivalent shielding.
Page 8
Connecting to a mains electrical supply THIS MACHINE MUST BE FITTED TO A 13AMP 240V MAINS INPUT Connecting to an Engine Driven Generator If connecting this machine to an engine driven generator please ensure the following Minimum Generator KVA Output – 5.0 KVA continuous Generator to be fitted with AVR (automatic voltage regulation) DO NOT USE ON A GENERATOR WITHOUT AVR Connecting to a generator without the above minimum requirements will in-...
Page 9
Connections for POWER TIG 170EXT Digital Rear machine connections Fig 1 1. On/Off Switch 2. 240V AC Auxiliary output Connect water cooler to socket, when machine is turned on by on/switch it will then output power from aux socket. Fig1.1 Main chassis earth bolt If you experience interference you can fit extra earth to this point (Not normally used) Gas Input connector...
Page 10
Connections for TIG (GTAW) Welding Fig 2 1. Negative power connector - Connect Tig Torch Dinze to power connector by inserting and twisting until tight ENSURE TIG TORCH IS FITTED TO NEGATIVE CONNECTOR OTHERWISE YOU WILL EXPERIENCE TUNGSTEN BURNBACK 2. Gas outlet - Quick release type Connect the torch gas hose 3.
Page 11
Connections for STICK MMA (SMAW) Welding Fig 3 1. Negative power connector - Connect the earth lead to by inserting and twisting until tight and the earth clamp to work/bench. 2. Not used for MMA welding 3. Positive power connector + Connect the electrode holder by inserting and twisting until tight 4.
Controls and Settings Fig 4 1. Memory store function There are 9 memory store programs to enable you to select required parameters for job in hand and then store to select channel. Press memory button until required program you wish to store is showing in LED Then enter parameters as required, now press and hold save button for 3 seconds and release, the green save LED will now light for about 2 seconds and then go out.
Page 13
Adjustable from 0 - 25 seconds, this enables the backed up gas pressure to be released from torch before actual arc is started. Common settings for most application is about .3 to .5 seconds - If welding stainless steel etc sometimes a longer pre-flow is required. 4.
Page 14
9. Pulse frequency adjustment This can be adjusted as follows: DC Mode 0.1 to 500Hz AC Advanced Squarewave 0.1 - 250Hz AC Soft Square, Triangular and Sinewave 0.1 - 10Hz Advanced AC Pulse 0.1 - 10Hz 10. AC Frequency Transformer based welders are normally fixed at 60Hz, due to the advanced inverter technology you can adjust from 20 - 250Hz.
Page 15
HOT burst at end of weld. 14. Post Flow Gas Adjustable from 0 - 50 seconds. When you stop welding the gas will continue to flow for this set amount of time, this allows the tungsten to cool without getting contaminated and also protect the weld bead until it has cooled slightly.
Page 16
21. Tig Pulse mode selector This machine has two pulse modes. Standard pulse works in both AC and DC modes Advanced AC pulse works only in AC mode Pulse is used to help control the amount of heat going into workpiece and commonly used on stainless steels and alloys.
Page 17
When the trigger mode is in the 4 step position the following sequence will occur Press and hold the Tig torch switch to start sequence. The machine will open gas valve to start flow of shield gas, after preset gas pre-flow time to flow time to purge air from torch hose the welding output of machine will be turned on and the arc will be started at start (min) current This condition can be maintained as long as required.
Page 18
by using your thumb to adjust knob on torch handle. This does take some getting used to but is handy when you are welding in a position where a foot pedal is not use-able. You can use a remote amperage torch in 2T or 4T mode, most common is 4T as you press trigger to start weld and then release you can then use thumb/finger for torch switch to adjust amperage knob, once weld has finished press the torch switch again to finish weld.
Operating machine SAFETY PRECAUTIONS WARNING! ELECTRIC SHOCK CAN KILL Do not touch electrically live parts or electrode with skin or wet clothing. Insulate yourself from work and ground Always wear dry insulating gloves WARNING! FUMES AND GASES can be dangerous Keep your head out of fumes &...
Page 20
Welding in TIG mode – No Pulse – No remote foot pedal 1. Connect the Tig Torch to machine, connect earth lead to machine & work piece. 2. Set to Tig mode pulse off (Fig 4.21) 3. Select 2 or 4 way torch operation (Fig 4.22) 4.
Page 21
Welding in TIG mode – with Remote amperage torch 1. Connect the Tig Torch to machine, connect earth lead to machine & work piece. 2. Set to Tig mode pulse off or Tig mode pulse on (Fig4.21) In welding with pulse in remote torch, the foot pedal controls peak main welding amperage 3.
The troubleshooting guide is provided to help you locate possible machine malfunctions If fault / problem is not listed below check our Tig Welder Support page on our website www.r-techwelding.co.uk/support.php or contact R-Tech by phone. Contact details can be found on front of this manual and our website...
Machine keeps overheating - Warning light is lit on machine Check if fan is running – if not contact R-Tech for repair Check the cooling vents for obstruction, blow out machine with clean dry low pressure air supply. Check for adequate ventilation around machine ...
Page 24
Machine stuck on minimum amps when welding although higher amperage has been Make sure machine has not been set to 4-way operation as when in this mode when you press torch switch you get minimum amps and when you let go of switch machine will go to maximum amps set.
Page 25
No HF when torch trigger pressed, no blue spark between HF points Examine and clean HF points with clean dry low pressure air line HF PCB faulty – Contact R-Tech for repair MMA Stick welding problems Stick electrode ‘blasts off’ when arc is struck...