Samsung RC060RTRGA User & Installation Manual
Samsung RC060RTRGA User & Installation Manual

Samsung RC060RTRGA User & Installation Manual

System air conditioner

Advertisement

USER'S & INSTALLATION
MANUAL
RC060RTRGA
RC070RTRGA
RC080RTRGA
RC100RTRGA
RC120RTRGA
RC150RTRGA
RC180RTRGA
RC200RTRGA
RC250RTRGA
System Air Conditioner
(Cooling Only)

Advertisement

Table of Contents
loading

Summary of Contents for Samsung RC060RTRGA

  • Page 1 USER’S & INSTALLATION MANUAL RC060RTRGA RC070RTRGA RC080RTRGA RC100RTRGA RC120RTRGA RC150RTRGA RC180RTRGA RC200RTRGA RC250RTRGA System Air Conditioner (Cooling Only)
  • Page 2: General Information

    WARNING ACCESSORIES............1 GENNERAL INFORMATION..........1 Ask your dealer for installation of the air conditioner. Incomplete installation performed by yourself may result in a DIMENSIONAL DATA..........2 water leakage, electric shock, and fire. LOCATIONS AND RECOMMENDATIONS......7 INSTALLATION ...............7 your dealer improvement, repair, maintenance. ELECTRICAL WIRING .............10 Incomplete improvement, repair, and maintenance may...
  • Page 3: Dimensional Data

    3. DIMENSIONAL DATA Units: mm 380-415V / 3Ph / 50Hz 6 / 7 Tons C/O Units 1223 2068 Condenser fan Filter access door 1235 Drain connection hole Hole for control wires maintain orifice 2089 for air supply motor Hole for power wires Hole for other purpose Control and comperssor access panel Fig.3-1...
  • Page 4 380-415V / 3Ph / 50Hz Units: mm 8 / 10 Tons C/O Units 1323 2149 Condenser fan 1002 Filter access door 1335 Drain connection hole maintain orifice Hole for control wires 2165 for air supply motor Hole for power wires Hole for other purpose Control and comperssor access panel Fig.3-4...
  • Page 5 380-415V / 3Ph / 50Hz Units: mm 12 / 15 Tons C/O Units 1245 Filter occess door Drain connection hole Maintain orifice for air supply motor 1825 Control and comperssor access panel Hole for control wires Hole for power wires Hole for other purpose Fig.3-7 Horizontal supply opening...
  • Page 6 Units: mm 380-415V / 3Ph / 50Hz 18 / 20 Tons C/O Units 2138 2748 1245 Filter access door Drain connection hole Maintain orifice for air supply motor 2157 Control and comperssor access panel Hole for control wires Hole for power wires Fig.3-10 Hole for other purpose Horizontal supply opening...
  • Page 7 380-415V / 3Ph / 50Hz Units: mm 25 Tons C/O Units 2138 2748 Drain connection hole Maintain orifice for air supply motor Maintain orifice for air supply motor 2157 Control and comperssor access panel Fig.3-13 Hole for control wires Hole for power wires Hole for othere purpose Horizontal supply opening Fresh air...
  • Page 8: Installation

    4. LOCATIONS AND RECOMMENDATIONS Caution must be taken at all times to avoid personal injuries and/or damage to the equipment. 4.1 Horizontal airflow application The unit must be mounted level for proper drainage of water When choose horizontal air supply mode, please remove through the holes in the base pan.
  • Page 9: Rooftop-Units

    Typical rooftop application with frame Spreader bars Horizontal Fig.5-1 air deflector 5.2 Rooftop-units Down-side air return Down-side air orifice’s cover supply orifice’s cover For roof top applications using a field fabricated frame and ducts, use the following procedure: The frame must be located and secured by bolting or welding to the roof.
  • Page 10: Condensate Drain Piping

    5.3 Ground level-horizontal units For ground level installations, the unit should be positioned on a pad in the size of the unit or larger. The unit must be level on the pad. The pad must not come in contact with the structure. Be sure the outdoor portion of the supply and return air ducts are as short as possible.
  • Page 11: Electrical Wiring

    ELECTRICAL WIRING Tab.6-3 Tab.6-4 6.1 Protections and safety control Nominal ton Nominal ton 8 Tons 10 Tons Model type Model type Minutes delay for the compressor start-up Type of flow Hor. & Dow. Type of flow Hor. & Dow. ● At the beginning of energizing or after the stop of the Unit main Unit main...
  • Page 12 Tab.6-8 Tab.6-9 Tab.6-7 Nominal ton 20 Tons Nominal ton 18 Tons Nominal ton 25 Tons Model type Model type Model type Type of flow Hor. & Dow. Type of flow Hor. & Dow. Type of flow Hor. Unit main Unit main Unit main - 415 - 415...
  • Page 13: Installation Example

    6.4 Wiring provision NOTE F ield wiring These data are based on the following conditions. The units are internally wired at the factory according to Evaporator Air Input Temperature 85 F DB, 66 F WB. generally accepted electrical technology. Condenser Air Input Temperature 115 F DB. Required field wiring The strating current is indicated for each compressor motor.
  • Page 14: Main Power Supply

    6.5 Main power supply Tab.6-12 Model type Unit main power Main power switch Fuse Wires for Power supplies 380 - 415V 3×10mm +2×6mm 6Tons 3N~ 50Hz 380 - 415V 3×10mm +2×6mm 7Tons 3N~ 50Hz 380 - 415V 3×16mm +2×10mm 8Tons 3N~ 50Hz 380 - 415V 3×16mm...
  • Page 15 6.6 Block cable connection To connect with wire controller See the left figure: 1. When SW3 has been set in “ON”, please select KJR-12B For C/O Units wire controller; 2. When SW3 has been set in “1”, please select the wire controller be recommended in the below.
  • Page 16: Error Code

    6.7 Error code Tab.6-13 Type Content Code Remarks Normal Standby Normal Constraint cool Normal Compressor phase sequence Error error or phase default Outdoor coil sensor in sys. A error Error Error Outdoor coil sensor in sys. B error Indoor coil sensor in sys. A error Error Error Indoor coil sensor in sys.
  • Page 17: Specification

    7. SPECIFICATION 7.1 Physical Data R22 380-415V / 3Ph / 50Hz Tab.7-1 7 Tons 6 Tons 8Tons 10 Tons 12 Tons 15 Tons Nominal ton Model type Hor. & Dow. Hor. & Dow. Hor. & Dow. Hor. & Dow. Hor. & Dow. Type of flow Hor.
  • Page 18 Tab.7-2 20 Tons 25 Tons 18 Tons Nominal ton Model type Hor. Type of flow Hor. & Dow. Hor. & Dow. 300000 Cooling capacity (Btu/h) 240000 210000 Capacity Heating capacity (Btu/h) Performance SEER SEER 10.0 Length(mm) Length(mm) 2753 2753 2753 2157 Dimensions Dimensions...
  • Page 19 7.2 Parameter For Air Volume Parameter table for indoor unit air volume Tab.7-3 Tab.7-7 6 Tons 12 Tons Fan speed Static pressure Air flow Fan speed Brake power Static pressure Air flow Brake power (Pa) (CFM) (rpm) (rpm) (kW) (Pa) (CFM) (kW) 3350...
  • Page 20 8 Tons Tab.7-11 25 Tons Static pressure Air flow Fan speed Brake power (rpm) (Pa) (CFM) (kW) 1000 12450 1002 11400 10000 1005 10200 1008 1010 9900 5.37 9790 1015 9300 1017 5.01 8600 1022 3400 3600 3800 4000 2600 2800 3000 3200...
  • Page 21 15 Tons 25 Tons 4750 5000 5250 5500 5750 6000 6250 6500 6750 7000 7250 Air volume(CFM) Air volume(CFM) Fig.7-9 Fig.7-6 18 Tons Parameter table for outdoor unit air volume NOTE S h i e l d p a r t s i n b e l o w t a b l e s a r e s t a n d a r d w o r k i n g conditions for the unit.
  • Page 22: Operating Conditions

    Tab.7-15 Tab.7-19 10 Tons 20 Tons Static pressure Brake power Air flow Fan speed Static pressure Air flow Brake power Fan speed (Pa) (kW) (CFM) (rpm) (Pa) (CFM) (kW) (rpm) 7060 0.78 14000 1.3×2 6765 0.79 13500 1.4×2 6471 0.80 13100 1.5×2 Tab.7-16...
  • Page 23: Capacity Data

    7.4 Capacity Data Cooling capacity — 6 Tons Tab.7-22 Flow 2100 2400 2600 2800 67.2 69.3 74.2 77.4 69.1 72.3 76.2 79.1 70.6 74.4 77.8 80.1 72.2 75.9 78.8 80.9 58.4 65.8 70.5 73.5 62.4 68.0 71.6 74.4 66.2 69.0 72.1 74.3 70.0 73.6 76.4 78.5 77.1 77.9 78.8 80.3...
  • Page 24 Cooling capacity — 7 Tons Tab.7-23 Flow 2700 3000 3300 3600 82.5 84.2 85.8 87.5 87.3 89.0 90.8 92.6 89.3 91.1 92.9 94.8 91.0 92.8 94.7 96.6 72.7 80.4 85.3 87.5 77.4 84.3 88.2 91.1 82.0 84.5 87.9 92.3 86.2 90.3 93.5 95.2 94.8 96.7 98.6 100.6 95.9 97.8 99.8 101.8 96.7 98.6 100.6 102.6 97.3 99.2 101.2 103.3 55.6 68.8 81.8 94.3 58.0 72.6 85.4 96.3 59.5 73.8 88.2 100.1 60.8 75.8 90.7 100.8 98.6 100.6 102.6 104.6 99.2 101.2 103.2 105.2 99.4 101.4 103.4 105.5 99.7 101.7 103.7 105.8...
  • Page 25 Cooling capacity — 8 Tons Tab.7-24 Air Flow 2700 3000 3400 3700 4000 Ent DB 91.6 95.5 99.3 102.4 96.5 100.7 104.5 107.8 98.6 102.8 106.7 110.2 100.7 105.1 109.2 112.5 101.5 105.6 109.2 113.6 71.4 82.1 90.1 94.9 76.8 88.1 96.6 101.7 80.8 92.8 101.7 107.1 83.2 95.6 104.5 110.3 85.2 98.1 107.3 111.9...
  • Page 26 Cooling capacity — 10 Tons Tab.7-25 Flow 3600 4000 4400 4800 110.9 113.1 115.4 117.7 113.8 116.1 118.4 120.8 116.5 118.8 121.2 123.6 118.6 121.0 123.4 125.9 96.8 98.7 100.7 102.7 103.2 105.3 107.4 109.5 109.2 111.4 113.6 115.9 114.7 117.0 119.3 121.7 123.4 125.9 128.4 131.0 124.6 127.1 129.6 132.2 125.7 128.2 130.8 133.4 126.3 130.0 131.4 134.0 73.2 92.0 108.3 124.8 75.6 94.3 112.8 128.5 78.0 97.3 116.5 130.4 79.6 99.7 119.4 131.2 127.9 130.5 133.1 135.7 128.3 130.9 133.5 136.2 128.6 131.2 133.8 136.5 129.8 132.4 135.0 137.7...
  • Page 27 Cooling capacity — 12 Tons Tab.7-26 Flow 4500 5000 5500 6000 140.6 148.5 136.6 139.5 145.5 153.4 138.1 150.5 157.4 143.6 145.5 153.5 159.4 133.0 134.6 141.6 141.1 148.8 118.8 151.4 106.9 126.7 135.0 142.6 112.8 134.6 134.5 143.0 149.5 123.8 138.2 145.8...
  • Page 28 Cooling capacity — 15 Tons Tab.7-27 Flow 5500 6000 6500 7000 174.2 185.1 163.6 165.6 172.9 182.7 168.0 171.6 179.0 188.7 169.9 193.6 176.6 179.0 188.8 196.1 131.5 155.8 166.0 175.3 138.7 165.6 173.6 183.0 146.1 167.2 177.7 185.9 152.3 171.8 181.3 188.2...
  • Page 29 Cooling capacity — 18 Tons Tab.7-28 Flow 6500 7000 7500 8000 198.7 203.8 216.6 191.4 193.7 202.3 213.7 196.6 200.7 209.4 220.7 226.5 206.6 209.4 220.9 229.4 162.3 193.7 203.1 214.1 171.0 197.6 210.1 214.3 222.5 153.8 182.3 196.3 207.3 219.7 178.1 203.1...
  • Page 30 Cooling capacity — 20 Tons Tab.7-29 Flow 7500 8000 8500 9000 216.1 218.7 228.5 241.3 222.0 226.7 236.4 249.3 224.4 230.1 244.6 255.8 233.4 236.4 249.4 173.7 205.9 221.6 234.1 183.3 218.7 229.3 241.8 193.1 223.2 237.2 248.1 201.2 229.3 242.0 242.1 245.1...
  • Page 31 Cooling capacity — 25 Tons Tab.7-30 Flow 9500 10000 10500 11000 2626 Notes: 1.All capacities are gross and have not considered indoor fan heat.To obtain NET cooling capacity subtract indoor fan heat. 2.MBH=Total Gross Capacity. (Unit:1000Btu/h) 3.SHC=Sensible Heat Capacity. (Unit:1000Btu/h) I&O manual...
  • Page 32: Maintenance And Upkeep

    START-UP Control box Packging and components ● Is the unit properly located and level with the proper clearance? ● Is the duct work correctly sized, run, taped, insulated, and weatherproofed with proper unit arrangement? See Ductwork Installation section. Control box access panel For 6-20 tons ●...
  • Page 33 For 6-20 tons Regulating belt of rate of tension, inner fan filter-Baffle-plate Refer to Fig.9-3, Fixed bolt of electric motor’s supporting slide was loosened, following electric motor was drived, belt of rate of tension will begin change. plate bolts Fig.9-3 Method of belt tensioning using belt tension indicator Calculate the deflection in mm on a basis of 16mm per meter of center distance .Center distance (m)×16=deflection (mm).
  • Page 34 Clean the air filter (Vacuum cleaner or pure water may be used ● Re-install the air filter to clean the air filter. If the dust accumulation is too heavy , please use soft brush and mild detergent to clean it and dry Condenser coil out in cool place) .
  • Page 36 Contact SAMSUNG WORLD WIDE If you have any comments or questions regarding a Samsung product, contact the SAMSUNG customer care center. Country Customer Care Center Web Site TURKEY 444 77 11 www.samsung.com SOUTH AFRICA 0860-SAMSUNG(726-7864 ) www.samsung.com U.A.E 800-SAMSUNG (726-7864) www.samsung.com...