Camden model EMF-2 (EMF-2m or EMF-2ABM) is a
microprocessor controlled multi-function relay. This
all-in-one design replaces our previous models
EMF-1, EMF-1m or EMF-1ABM.
The EMF-2 is designed for specialized applications
such as ABM vestibules, one or two-door restrooms
in shared-use facilities, 2 – 5 door airlocks, and
secure man-traps.
Dip switches let you easily choose the mode, and the
unit automatically programs the inputs, outputs and
potentiometers accordingly.
Removable terminal strips simplify wiring chores, and
all adjustments are conveniently located on one end
of the case.
IMPORTANT: Do not apply power to the unit until
you have read the instructions fully and made the
required adjustments.
Section 2__________________
Installation
Mounting
The EMF-2 should be mounted in a clean dry location
out of direct contact with the elements.
locations include inside a metal box, operator header,
or above a false ceiling. If placed on top of a header,
ensure that unauthorized personnel cannot tamper
with the unit.
If used in an Airlock or Mantrap application, the relay
may be located at either door location, or, centrally to
all doors.
You must bring wiring from all door
actuators to this unit (as well as the lock, operator,
and door contact outputs as appropriate).
The EMF-2 is also available in an attractive lockable
metal cabinet version (EMF-2m or EMF-2ABM),
suitable for wall mounting.
Fax: 905-366-3378
Suitable
EMF-2 / EMF-2m
Multi-Function Timer
Installation Instructions
Ver. A1-001
MADE IN CANADA
Wiring
Wiring of this unit is dependant on the mode desired.
Select your intended application, then proceed to the
section indicated.
Note: Do not wire Safety devices to the EMF-2. If
installed, wire your safety device directly to the
operator control box.
IMPORTANT:
Changes to the Mode and Out2
do not take effect until a power reset. It is therefore
best to make these adjustments with the power
turned off!
NOTE:
We highly recommend the use of a
regulated power supply when powering equipment for
barrier-free washroom applications where the strike
power may be maintained from a few minutes to
many hours.
We offer a low-cost board-only
regulated power supply - CX-PS13 V2, which in turn
can be powered from a small 24VAC transformer, (or
the auxiliary power on the door control) and will
supply clean, filtered & regulated 24VDC power for
the strike and EMF-2.
APPLICATIONS
& SET-UP INSTRUCTIONS:
ABM Vestibule Control
(Mode 1) Proceed to section 3A
1 Door Unsecured Restroom
(Mode 2) Proceed to section 3B
1 Door Secured Restroom
(Mode 3) Proceed to section 3C
2 Door Unsecured Restroom
(Mode 4) Proceed to section 3D
2 / 3 Door Airlock (w/ auto-crossing)
(Mode 5) Proceed to section 3E
2 - 5 Door Airlock
(Mode 6) Proceed to section 3F
2 Door Man-trap
(Mode 7) Proceed to section 3G on Page 17
System Inspection Instructions
Technical Specifications, & Warranty
PAGE 1 OF 19
on Page 3
on Page 5
on Page 7
on Page 11
on Page 13
on Page 15
Page 18
Page 19