OPERATOR’S MANUAL Model 150, 152, 162, & 168 Soft Serve Freezers Original Operating Instructions 028749- M 8/13/08 (Original Publication) Updated 1/6/15...
Page 2
Complete this page for quick reference when service is required: Taylor Distributor: Address: Phone: Service: Parts: Date of Installation: Information found on data plate: Model Number: Serial Number: Electrical Specs: Voltage Cycle Phase Maximum Fuse Size: Amps Minimum Wire Ampacity:...
Page 4
Statutory Damages of up to $250,000 (17 USC 504) for infringement, and may result in further civil and criminal penalties. All rights reserved. Taylor Company a division of Carrier Commercial Refrigeration, Inc. 750 N. Blackhawk Blvd. Rockton, IL 61072 Models 150, 152, 162, 168 Table of Contents...
This piece of equipment is made in the USA and has Note: All repairs must be performed by an USA sizes of hardware. All metric conversions are authorized Taylor Service Technician. approximate and vary in size. 131122 Models 150, 152, 162, 168 To the Installer...
(22 mm) hole in base pan. Connect two power supply leads. Attach ground (earth) wire to the grounding lug inside the The models 150 and 152 require a minimum of 6” (152 electrical box. mm) of clearance around both sides. Install the skirt...
If burns are severe, apply Beater Rotation ice packs and contact a physician immediately. Taylor reminds technicians to be cautious of government laws regarding refrigerant recovery, Beater rotation must be clockwise as viewed recycling, and reclaiming systems. If you have any looking into the freezing cylinder.
August 13, 2005. Therefore, operation. The Taylor Company models covered in this it must be collected separately after its use is manual consist of the following: 150, 152, 162 and 168. completed, and cannot be disposed as unsorted municipal waste.
We, at Taylor Company, are concerned about the safety of the operator when he or she comes in contact with the freezer and its parts. Taylor has gone to extreme efforts to design and manufacture built- in DO NOT operate the freezer unless it is safety features to protect both you and the service properly grounded.
Page 10
DO NOT obstruct air intake and discharge openings: 150 and 152: Minimum of 6” (152 mm) of This unit has many sharp edges that can clearance around both sides. Install the skirt cause severe injuries.
Models 150 & 152 Door Assembly Figure 5 Item Description Part No. Item Description Part No. Valve- Draw 024763 Door A.- 1 Spout X38959- SER O- Ring- 7/8 OD x .103 W 014402 Bearing- Guide 014496 O- Ring- 3/4 OD x .103 W 015835 O- Ring- 2- 3/4 OD x .139 W...
O- Ring- 2- 3/4 OD x .139 W 019998 Pin A.- Pivot Short X38539 Bearing- Front 023262 O- Ring- 5/16 OD x .070 W 016272 Beater A. X24689 Handle- Draw Valve 030564 Seal- U- Cup 080534 120501 Operator Parts Identification Models 150, 152, 162, 168...
047518 *Note: A sample container of sanitizer is sent with the unit. For reorders, order Stera Sheen part no. 055492 (100 2 oz. packs) or Kay-5 part no. 041082 (200 packs). 110804 Operator Parts Identification Models 150, 152, 162, 168...
To better communicate in the International arena, the words on many of our operator switches and buttons = STANDBY key have symbols to indicate their functions. Your Taylor equipment is designed with these International symbols. Models 150, 152, 162, 168...
Mix Refrigeration Switch Feed Tube The mix refrigeration switch is located under the The models 150, 152, 162 and 168 are called upon to control channel and is used for several purposes: handle a large variety of products (i.e., soft serve, For the unit to operate in the “AUTO”...
With cylinder is refrigerated during the “STANDBY” mode of sanitized hands, remove the feed tube. Turn it over operation. and place the end with the hole into the mix inlet hole. Models 150, 152, 162, 168 Important: To the Operator...
The Model 150 is a console model with a single spout door. The Model 152 is a counter model with a single spout door. The Model 162 is a counter model and the Model 168 Figure 12 is a console model.
Place the large o- ring(s) into the groove(s) on the back MAKE SURE THE POWER SWITCH IS IN of the freezer door and lubricate with Taylor Lube. THE “OFF” POSITION. Failure to follow this instruction may result in electrocution or injury to fingers or hands from hazardous moving parts.
Page 24
Figure 19 Note: For the Models 162/168, install the valve seal in the grooves on the center draw valve and lubricate with Taylor Lube. This special seal will prevent mix from one freezing cylinder from traveling into the Figure 22 second cylinder.
Page 25
Snap the design cap(s) over the bottom of the freezer door spout(s). Figure 24 Note: For Models 162/168, slide the o- ring onto each pivot pin and lubricate with Taylor Lube. Figure 27 Step 14 Install the front drip tray and splash shield under the freezer door.
Place the power switch in the “WASH” position. This will cause the sanitizing solution in the freezing cylinder to be agitated. Allow it to agitate for five minutes. Figure 29 Figure 30 Figure 33 Operating Procedures Models 150, 152, 162, 168...
Make sure the small hole in the feed tube is down. Figure 35 Repeat Steps 1 through 7 for the second freezing cylinder on Models 162/168. Figure 37 Models 150, 152, 162, 168 Operating Procedures...
Figure 38 Step 5 Figure 40 Place the power switch in the “AUTO” position. Closing Procedure To disassemble the Models 150/152/162/168, the following items will be needed: Two cleaning pails Figure 39 Sanitized stainless steel rerun can with lid Step 6...
When the rinse water stops flowing from the door spout, lower the draw valve and place the power Repeat Steps 1 through 5 for the other side of the switch in the “OFF” position. freezer on Models 162/168. 140721 Models 150, 152, 162, 168 Operating Procedures...
Figure 41 Step 2 Remove the cup seal(s) from the drive shaft(s) of the Step 7 beater assembly(ies). Wipe clean all exterior surfaces of the freezer. 150105 Operating Procedures Models 150, 152, 162, 168...
Be sure to have a generous j 4. Follow all lubricating procedures as outlined in amount of cleaning solution on the brush. “Assembly”. Models 150, 152, 162, 168 Important: Operator Checklist...
Your local Taylor distributor can perform this service for you. j 6. On the auxiliary refrigeration system, check the condenser for accumulation of dirt and lint. A...
3. The product is too stiff. a. The temperature control a. Adjust the temperature control. Do not set the or the T.Q.C. is set too temperature colder than cold. 18_F (- 8_C). If T.Q.C., contact service technician. Models 150, 152, 162, 168 Troubleshooting Guide...
Page 34
8. Product is not feeding into a. The mix level is a. Fill the mix hopper with mix. the freezing cylinder. inadequate in the mix hopper. b. The mix inlet hole is b. Contact service technician. frozen. Troubleshooting Guide Models 150, 152, 162, 168...
Page 35
The center draw valve a. Lubricate properly and 20 / 32 replace seal every 3 Mix from one freezing seal is worn, or is months. cylinder bleeds over to the improperly lubricated. second cylinder. Models 150, 152, 162, 168 Troubleshooting Guide...
Taylor, through an authorized Taylor distributor or service agency, will provide a new or re- manufactured part, at Taylor’s option, to replace the failed defective part at no charge for the part. Except as otherwise stated herein, these are Taylor’s exclusive obligations under this limited warranty for a Product failure.
Page 38
LEGAL REMEDIES The owner must notify Taylor in writing, by certified or registered letter to the following address, of any defect or complaint with the Product, stating the defect or complaint and a specific request for repair, replacement, or other correction of the Product under warranty, mailed at least thirty (30) days before pursuing any legal rights or remedies.
Taylor warrants the Parts against failure due to defect in materials or workmanship under normal use and service as follows. All warranty periods begin on the date of original installation of the Part in the Taylor unit. If a Part fails due to defect during the applicable warranty period, Taylor, through an authorized Taylor distributor or service agency, will provide a new or re- manufactured Part, at Taylor’s option, to replace the failed defective Part at no...
Page 40
Parts or the units in which they are installed repaired or altered in any way so as, in the judgment of Taylor, to adversely affect performance, or normal wear or deterioration.
Page 41
LEGAL REMEDIES The owner must notify Taylor in writing, by certified or registered letter to the following address, of any defect or complaint with the Part, stating the defect or complaint and a specific request for repair, replacement, or other correction of the Part under warranty, mailed at least thirty (30) days before pursuing any legal rights or remedies.
Page 45
LEFT POWER SUPPLY LEFT MAIN LEFT MAIN LEFT MAIN BLK CORD BLK CORD COMPRESSOR COMPRESSOR COMPRESSOR CONTACTOR (FIG. 3) CONTACTOR MAIN CONDENSER FAN WHT/ORN ONLY.) (ONE (1) FAN MOTOR ONLY FOR MODEL 168. RUN CAPACITOR APPLIES TO MODEL 168 LEFT MAIN COMPRESSOR CONTACTOR WHT/GRA...
Page 46
NOTES: 1. ONE (1) FAN ONLY ON MODEL FIG. 1 168. RUN CAPACITOR APPLIES TO MODEL 168 ONLY. START RELAY (047702-27) START CAPACITOR (047703) STANDBY TEMP START WINDING CONTROL MAIN WINDING 3PDT SHR SW. WINDING PROTECTOR BLACK/WHITE STRIPE WHITE/BLK STR (INTERNAL) STANDBY COMPRESSOR WIRING...
Page 47
POWER SUPPLY GRN/YEL GRN/YEL GRN/YEL GRN/YEL LEFT MAIN LEFT MAIN LEFT MAIN BLK CORD BLK CORD COMPRESSOR COMPRESSOR COMPRESSOR GRN/YEL CONTACTOR (FIG. 3) CONTACTOR MAIN CONDENSER FAN ONLY.) (ONE (1) FAN MOTOR ONLY FOR MODEL 168. RUN CAPACITOR APPLIES TO MODEL 168 LEFT COMPRESSOR "ON"...