Summary of Contents for Taylor 152

  • Page 1 OPERATOR’S MANUAL Model 150, 152, 162, & 168 Soft Serve Freezers Original Operating Instructions 028749- M 8/13/08 (Original Publication) Updated 1/6/15...
  • Page 2 Complete this page for quick reference when service is required: Taylor Distributor: Address: Phone: Service: Parts: Date of Installation: Information found on data plate: Model Number: Serial Number: Electrical Specs: Voltage Cycle Phase Maximum Fuse Size: Amps Minimum Wire Ampacity:...
  • Page 3: Table Of Contents

    ............Models 150 & 152 Door Assembly .
  • Page 4 Statutory Damages of up to $250,000 (17 USC 504) for infringement, and may result in further civil and criminal penalties. All rights reserved. Taylor Company a division of Carrier Commercial Refrigeration, Inc. 750 N. Blackhawk Blvd. Rockton, IL 61072 Models 150, 152, 162, 168 Table of Contents...
  • Page 5: To The Installer

    This piece of equipment is made in the USA and has Note: All repairs must be performed by an USA sizes of hardware. All metric conversions are authorized Taylor Service Technician. approximate and vary in size. 131122 Models 150, 152, 162, 168 To the Installer...
  • Page 6: Air Cooled Units

    (22 mm) hole in base pan. Connect two power supply leads. Attach ground (earth) wire to the grounding lug inside the The models 150 and 152 require a minimum of 6” (152 electrical box. mm) of clearance around both sides. Install the skirt...
  • Page 7: Beater Rotation

    If burns are severe, apply Beater Rotation ice packs and contact a physician immediately. Taylor reminds technicians to be cautious of government laws regarding refrigerant recovery, Beater rotation must be clockwise as viewed recycling, and reclaiming systems. If you have any looking into the freezing cylinder.
  • Page 8: To The Operator

    August 13, 2005. Therefore, operation. The Taylor Company models covered in this it must be collected separately after its use is manual consist of the following: 150, 152, 162 and 168. completed, and cannot be disposed as unsorted municipal waste.
  • Page 9: Safety

    We, at Taylor Company, are concerned about the safety of the operator when he or she comes in contact with the freezer and its parts. Taylor has gone to extreme efforts to design and manufacture built- in DO NOT operate the freezer unless it is safety features to protect both you and the service properly grounded.
  • Page 10 DO NOT obstruct air intake and discharge openings: 150 and 152: Minimum of 6” (152 mm) of This unit has many sharp edges that can clearance around both sides. Install the skirt cause severe injuries.
  • Page 11: Operator Parts Identification

    Plate- Decorative 041034- SS Panel A.- Lower Front X25518 Holder- Drip Tray 035866 Tray- Drip 10- 7/8 x 4- 7/16 025062 Caster- 3” Rigid 012226 Shield- Splash 11- 1/4 x 4- 13/16 025063 Models 150, 152, 162, 168 Operator Parts Identification...
  • Page 12: Model 152

    025862- SS Pan- Drip 11- 5/8 Long 027503 Trim- Top Back 025866 Leg- Plastic 024755 Plate- Decorative 041034- SS Light- Amber- Round Mix Low 039707 Holder- Drip Tray 035866 Panel- Side Right 051558 Operator Parts Identification Models 150, 152, 162, 168...
  • Page 13: Model 162

    Panel- Side Right 050214- SS Panel A.- Front X30711 Trim- Panel- Rear 035923 Light- Amber- Round Mix Low 039707 Plate- Decorative 039723- SS Decal- Decorative- Taylor 047666 Holder- Drip Tray 035866 Shield- Splash 030789 Models 150, 152, 162, 168 Operator Parts Identification...
  • Page 14: Model 168

    Trim- Top Back Panel 030775 Decal- Decorative- Taylor 047666 Trim- Middle Back Panel 030795 Shield- Splash 17- 5/8 Long 030789 Plate- Decorative 039723- SS Tray- Drip 16- 7/8 Long 030565 Holder- Drip Tray 035866 Operator Parts Identification Models 150, 152, 162, 168...
  • Page 15: Models 150 & 152 Door Assembly

    Models 150 & 152 Door Assembly Figure 5 Item Description Part No. Item Description Part No. Valve- Draw 024763 Door A.- 1 Spout X38959- SER O- Ring- 7/8 OD x .103 W 014402 Bearing- Guide 014496 O- Ring- 3/4 OD x .103 W 015835 O- Ring- 2- 3/4 OD x .139 W...
  • Page 16: Models 162 & 168 Door Assembly

    O- Ring- 2- 3/4 OD x .139 W 019998 Pin A.- Pivot Short X38539 Bearing- Front 023262 O- Ring- 5/16 OD x .070 W 016272 Beater A. X24689 Handle- Draw Valve 030564 Seal- U- Cup 080534 120501 Operator Parts Identification Models 150, 152, 162, 168...
  • Page 17: Models 150 And 152 Accessories

    Models 150 and 152 Accessories Figure 7 Item Description Part No. Item Description Part No. Kit A.- Tune Up X25802 Brush- Mix Pump Body- 3 x 7 White 023316 Brush- Rear Bearing 1” x 2” 013071 Pail- 6 Qt. 023348...
  • Page 18: Models 162 And 168 Accessories

    047518 *Note: A sample container of sanitizer is sent with the unit. For reorders, order Stera Sheen part no. 055492 (100 2 oz. packs) or Kay-5 part no. 041082 (200 packs). 110804 Operator Parts Identification Models 150, 152, 162, 168...
  • Page 19: Important: To The Operator

    To better communicate in the International arena, the words on many of our operator switches and buttons = STANDBY key have symbols to indicate their functions. Your Taylor equipment is designed with these International symbols. Models 150, 152, 162, 168...
  • Page 20: Reset Button

    Mix Refrigeration Switch Feed Tube The mix refrigeration switch is located under the The models 150, 152, 162 and 168 are called upon to control channel and is used for several purposes: handle a large variety of products (i.e., soft serve, For the unit to operate in the “AUTO”...
  • Page 21: Cylinder Temperature Retention (Ctr)

    With cylinder is refrigerated during the “STANDBY” mode of sanitized hands, remove the feed tube. Turn it over operation. and place the end with the hole into the mix inlet hole. Models 150, 152, 162, 168 Important: To the Operator...
  • Page 22: Operating Procedures

    The Model 150 is a console model with a single spout door. The Model 152 is a counter model with a single spout door. The Model 162 is a counter model and the Model 168 Figure 12 is a console model.
  • Page 23: Assembly

    Place the large o- ring(s) into the groove(s) on the back MAKE SURE THE POWER SWITCH IS IN of the freezer door and lubricate with Taylor Lube. THE “OFF” POSITION. Failure to follow this instruction may result in electrocution or injury to fingers or hands from hazardous moving parts.
  • Page 24 Figure 19 Note: For the Models 162/168, install the valve seal in the grooves on the center draw valve and lubricate with Taylor Lube. This special seal will prevent mix from one freezing cylinder from traveling into the Figure 22 second cylinder.
  • Page 25 Snap the design cap(s) over the bottom of the freezer door spout(s). Figure 24 Note: For Models 162/168, slide the o- ring onto each pivot pin and lubricate with Taylor Lube. Figure 27 Step 14 Install the front drip tray and splash shield under the freezer door.
  • Page 26: Sanitizing

    Place the power switch in the “WASH” position. This will cause the sanitizing solution in the freezing cylinder to be agitated. Allow it to agitate for five minutes. Figure 29 Figure 30 Figure 33 Operating Procedures Models 150, 152, 162, 168...
  • Page 27: Priming

    Make sure the small hole in the feed tube is down. Figure 35 Repeat Steps 1 through 7 for the second freezing cylinder on Models 162/168. Figure 37 Models 150, 152, 162, 168 Operating Procedures...
  • Page 28: Closing Procedure

    Figure 38 Step 5 Figure 40 Place the power switch in the “AUTO” position. Closing Procedure To disassemble the Models 150/152/162/168, the following items will be needed: Two cleaning pails Figure 39 Sanitized stainless steel rerun can with lid Step 6...
  • Page 29: Draining Product From The Freezing Cylinder

    When the rinse water stops flowing from the door spout, lower the draw valve and place the power Repeat Steps 1 through 5 for the other side of the switch in the “OFF” position. freezer on Models 162/168. 140721 Models 150, 152, 162, 168 Operating Procedures...
  • Page 30: Disassembly

    Figure 41 Step 2 Remove the cup seal(s) from the drive shaft(s) of the Step 7 beater assembly(ies). Wipe clean all exterior surfaces of the freezer. 150105 Operating Procedures Models 150, 152, 162, 168...
  • Page 31: Important: Operator Checklist

    Be sure to have a generous j 4. Follow all lubricating procedures as outlined in amount of cleaning solution on the brush. “Assembly”. Models 150, 152, 162, 168 Important: Operator Checklist...
  • Page 32: Winter Storage

    Your local Taylor distributor can perform this service for you. j 6. On the auxiliary refrigeration system, check the condenser for accumulation of dirt and lint. A...
  • Page 33: Troubleshooting Guide

    3. The product is too stiff. a. The temperature control a. Adjust the temperature control. Do not set the or the T.Q.C. is set too temperature colder than cold. 18_F (- 8_C). If T.Q.C., contact service technician. Models 150, 152, 162, 168 Troubleshooting Guide...
  • Page 34 8. Product is not feeding into a. The mix level is a. Fill the mix hopper with mix. the freezing cylinder. inadequate in the mix hopper. b. The mix inlet hole is b. Contact service technician. frozen. Troubleshooting Guide Models 150, 152, 162, 168...
  • Page 35 The center draw valve a. Lubricate properly and 20 / 32 replace seal every 3 Mix from one freezing seal is worn, or is months. cylinder bleeds over to the improperly lubricated. second cylinder. Models 150, 152, 162, 168 Troubleshooting Guide...
  • Page 36: Parts Replacement Schedule

    Double Ended Brush Inspect & Replace Minimum if Necessary White Bristle Brush, 1” x 2” Inspect & Replace Minimum if Necessary White Bristle Brush, 3” x 7” Inspect & Replace Minimum if Necessary 120501 Parts Replacement Schedule Models 150, 152, 162, 168...
  • Page 37: Section 10 Limited Warranty On Equipment

    Taylor, through an authorized Taylor distributor or service agency, will provide a new or re- manufactured part, at Taylor’s option, to replace the failed defective part at no charge for the part. Except as otherwise stated herein, these are Taylor’s exclusive obligations under this limited warranty for a Product failure.
  • Page 38 LEGAL REMEDIES The owner must notify Taylor in writing, by certified or registered letter to the following address, of any defect or complaint with the Product, stating the defect or complaint and a specific request for repair, replacement, or other correction of the Product under warranty, mailed at least thirty (30) days before pursuing any legal rights or remedies.
  • Page 39: Limited Warranty On Parts

    Taylor warrants the Parts against failure due to defect in materials or workmanship under normal use and service as follows. All warranty periods begin on the date of original installation of the Part in the Taylor unit. If a Part fails due to defect during the applicable warranty period, Taylor, through an authorized Taylor distributor or service agency, will provide a new or re- manufactured Part, at Taylor’s option, to replace the failed defective Part at no...
  • Page 40 Parts or the units in which they are installed repaired or altered in any way so as, in the judgment of Taylor, to adversely affect performance, or normal wear or deterioration.
  • Page 41 LEGAL REMEDIES The owner must notify Taylor in writing, by certified or registered letter to the following address, of any defect or complaint with the Part, stating the defect or complaint and a specific request for repair, replacement, or other correction of the Part under warranty, mailed at least thirty (30) days before pursuing any legal rights or remedies.
  • Page 42: Wiring Diagrams

    RED/WHT BLACK BRN/WHT 150/152 050416-12 11/12/13...
  • Page 43 WHT/BLK RED/WHT 150/152 050416-27 11/12/13...
  • Page 44 WHT/BLK RED/WHT BLACK GRN/YEL GRN/YEL GRN/YEL 150/152 050416-40 11/12/13...
  • Page 45 LEFT POWER SUPPLY LEFT MAIN LEFT MAIN LEFT MAIN BLK CORD BLK CORD COMPRESSOR COMPRESSOR COMPRESSOR CONTACTOR (FIG. 3) CONTACTOR MAIN CONDENSER FAN WHT/ORN ONLY.) (ONE (1) FAN MOTOR ONLY FOR MODEL 168. RUN CAPACITOR APPLIES TO MODEL 168 LEFT MAIN COMPRESSOR CONTACTOR WHT/GRA...
  • Page 46 NOTES: 1. ONE (1) FAN ONLY ON MODEL FIG. 1 168. RUN CAPACITOR APPLIES TO MODEL 168 ONLY. START RELAY (047702-27) START CAPACITOR (047703) STANDBY TEMP START WINDING CONTROL MAIN WINDING 3PDT SHR SW. WINDING PROTECTOR BLACK/WHITE STRIPE WHITE/BLK STR (INTERNAL) STANDBY COMPRESSOR WIRING...
  • Page 47 POWER SUPPLY GRN/YEL GRN/YEL GRN/YEL GRN/YEL LEFT MAIN LEFT MAIN LEFT MAIN BLK CORD BLK CORD COMPRESSOR COMPRESSOR COMPRESSOR GRN/YEL CONTACTOR (FIG. 3) CONTACTOR MAIN CONDENSER FAN ONLY.) (ONE (1) FAN MOTOR ONLY FOR MODEL 168. RUN CAPACITOR APPLIES TO MODEL 168 LEFT COMPRESSOR "ON"...

This manual is also suitable for: