Page 2
! WARNING This manual is intended for qualified service personnel only. To reduce the risk of electric shock, fire or injury, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so. Refer all servicing to qualified service personnel.
Related manuals ... 3 (E) Trademarks ... 3 (E) 1. Installation 1-1. Checking ROM Version ...1-1 (E) 1-2. Configuration of BKP-7933 ...1-1 (E) 1-3. Installation Procedure...1-1 (E) 1-4. Setting Switches on the IF-689 Board ...1-2 (E) 1-5. Installation ...1-4 (E) 1-5-1.
Page 4
1-9-4. Modification of RCP-721 ...1-42 (E) 1-9-5. Modification of RCP-730/731 ...1-43 (E) 1-10. Using the BKP-7933 in the HD System ...1-44 (E) 1-10-1. Controlling the Routing Switcher via the RS-422A Interface ...1-44 (E) 1-10-2. Controlling a Waveform Monitor ...1-46 (E) 1-11.
Trademarks BKP-7933 Manual Structure This manual is the installation manual for S-BUS Interface Board BKP-7933. This manual describes the information items necessary when the unit is supplied and installed. Besides this installation manual the following manuals are available for this unit.
1-1. Checking ROM Version When the BKP-7933 is installed in the CNU-700, be sure to check that the ROM versions for IC4 and IC5/AT-89 board of the CNU-700 are Ver. 3.00 or higher. If the ROM needs to be replaced, contact your local Sony Sales Office/Service Center.
Set the CNU GROUP No. so that it should be unique in a system. Factory default setting: Setting Examples 1. When installing the BKP-7933 in the CNU-700 which is provided with the BKP-7930 2. When using the two CNU-700s which are provided with the BKP-7930 CNU GROUP No. 0 (IF-480) CNU GROUP No.
Page 9
1(ON) 0(OFF) Setting example S-BUS ID No. Factory default setting: indicates the switch lever position) IF-689 board S-BUS BKP-7933 S201 S-BUS ID No. CNU GROUP No. RX TX (Component side/A side) 1-4. Setting Switches on the IF-689 Board 1-3 (E)
1. Loosen the two screws and remove the front panel of the CNU-700. Screw Front panel Screw 2. Insert the IF-689 board in the fourth slot from the top. IF-689 board 3. Attach the front panel to its original position. 1-4 (E) BKP-7933...
1-5-2. Installing the Rear Panel 1. Remove the two screws and remove the blank panel. 2. Install the rear panel with the two screws instead of the blank panel. B3 x 5 Rear panel B3 x 5 Blank panel 1-5 (E) BKP-7933...
1: The BNC connector (T bridge) is available to connect the BELDEN 8281 cables. BNC connector (T bridge): 1-764-805-11 2: The plug needs the following solderless contacts. AWG#18 to #22: 1-566-493-21 AWG#22 to #24: 1-564-774-11 AWG#24 to #30: 1-564-775-11 1-6 (E) Conection Cable BELDEN 8281 BKP-7933...
. Be sure to terminate the BNC connector (T bridge) attached to the last machine of the S-BUS line with a 75 Z terminator. REMOTE S-BUS (BNC connector, male) BKP-7933 BELDEN 8281 cable (shorter than 50 cm) 1-8 (E) <Primary station>...
TRIAX CABLE 3 CAM CCU 3 TRIAX CABLE CAMERA COMMAND NETWORK UNIT CNU-700 with BKP-7933 (S-BUS INTERFACE) DIGITAL VIDEO INTERFACE UNIT PFV-D10 ROUTING SWITCHER CONTROLLER BOARD BKPF-R70 (PRIMARY STATION) DIGITAL VIDEO SWITCHER DVS-7000 : S-BUS BNC : VIDEO BNC : T Bridge...
S-BUS ID number of the BKP-7933 using the numeric keys and press [ENTER]. The display changes to the called BKP-7933 menu display. . If the specified BKP-7933 does not exist on the S- BUS data link, an error is displayed. Display: “Station does not exist”...
Page 17
Saving the Setup Data Press [Ctrl] - [E] to validate and save the setup data and to return to the BKP-7933 menu display. Press [Ctrl] - [D] to return to the BKP-7933 menu display without saving the setup data. Level Mapping The level of the routing system can be set in this system.
Digital Video Routing Switcher (SOURCE No.) SERIAL (001) IN 1 SERIAL (002) IN 2 SERIAL (003) IN 3 SERIAL (004) IN 4 SERIAL (005) IN 5 SERIAL IN 6 (006) (DESTINATION No.) RCP1 RCP2 RCP3 RCP-700 series RCP4 RCP5 RCP6 BKP-7933...
Page 19
* If using the ANALOG ROUTING SWITCHER (BVS-V3232 etc.), connect it to PIX or WF connector (PIX 1 or WF 1 connector for the CCU-700A series) BKP-7933 CCA-5 CNU-700 with BKP-7933 CABLE CCU 1 to 6 RCP 1 to 6...
1-7. Setting Up Setting from the S-BUS Primary Station 1. Select the menu item “Z:BKP-7933 CONFIGURA- TION” and press [ENTER]. 2. Select either “A:ROUTER PIX1 ASSIGN” or “B:ROUTER WF1 ASSIGN” using the cursor key and press [ENTER]. (The illustration shows the display that selects “A:ROUTER PIX1 ASSIGN”.
VE monitor. This function is useful especially when the SDI signal is switched. BVP-500/700/900 series CCU-700A CCU 1 CCU 2 CCU 3 CCU 4 CCU 5 CCU 6 BKP-7933 (SOURCE No.) Digital Video Routing Switcher SERIAL IN 1 (001) SERIAL (002) IN 2 SERIAL...
Page 22
* If using the ANALOG ROUTING SWITCHER (BVS-V3232 etc.), connect it to PIX or WF connector (PIX 2 or WF 2 connector for the CCU-700A series) 1-16 (E) CCA-5 CNU-700 with BKP-7933 CABLE CCU 1 to 6 REMOTE S-BUS CHARACTER...
Page 23
Setting from the S-BUS Primary Station 1. Select the menu item “Z:BKP-7933 CONFIGURA- TION” and press [ENTER]. 2. Select either “C:ROUTER PIX2 ASSIGN” or “D:ROUTER WF2 ASSIGN” using the cursor key and press [ENTER]. (The illustration shows the display that selects “C:ROUTER PIX2 ASSIGN”. ) 3.
S-BUS BNC (BELDEN 8281) VIDEO BNC * If using the ANALOG ROUTING SWITCHER (BVS-V3232 etc.), connect it to PIX, WF or VBS connector 1-18 (E) CCA-5 CNU-700 with BKP-7933 CABLE CCU 1 to 6 RCP 1 to 6 CCA-5 CHARACTER...
Page 25
Setting from the S-BUS Primary Station 1. Select the menu item “Z:BKP-7933 CONFIGURA- TION” and press [ENTER]. 2. Select either “E:ROUTER PIX3 ASSIGN” or “F:ROUTER WF3 ASSIGN” using the cursor key and press [ENTER]. (The illustration shows the display that selects “E:ROUTER PIX3 ASSIGN”. ) 3.
Page 26
Linking the Preview Monitor Selection with MSU and VCS 1. Select the menu item “Z:BKP-7933 CONFIGURA- TION” and press [ENTER]. 2. Select the menu item “H:BKP-7933 MODE” and press [ENTER]. 3. Move the cursor key to the “LINK MSU” of “2 RCP PREVIEW SWITCH”...
Page 27
ALT1: The preview display appears when the RCP PREVIEW switch is pressed once but cannot be turned off. (If the PREVIEW switch is turned on from another RCP, the preview display can be switched.) 5. Set the MODE switch to 0. BKP-7933 MODE CHARACTER PHASE UP DOWN...
CNUs.) The setup data of the RCP assignment that is made here is saved in the BKP-7933 side.) . The contents of the settings that are made using this menu are reflected in the “Setting status of the control system”...
Page 29
OUTPUT S-BUS BNC (BELDEN 8281) VIDEO BNC * If using the ANALOG ROUTING SWITCHER (BVS-V3232 etc.), connect it to PIX, WF or VBS connector BKP-7933 CCA-5 CNU-700 with BKP-7933 CABLE CCU 1 to 6 RCP 1 to 6 CCA-5 CHARACTER...
Page 30
. Any number in the range of 1 to 8 can be set to the LEVEL No. This setting can be assigned to the respective level and can be mapped. 1-24 (E) SONY ROUTING SYSTEM SETUP MENU BKP-7933 V1.00 MODIFICATION COMMAND A: SET UNIT LOCATION(CAM-CCU)
OUTPUT S-BUS BNC (BELDEN 8281) VIDEO BNC * If using the ANALOG ROUTING SWITCHER (BVS-V3232 etc.), connect it to PIX, WF or VBS connector BKP-7933 CCA-5 CNU-700 with BKP-7933 CABLE CCU 1 to 6 CHARACTER REMOTE S-BUS REMOTE REMOTE CONTROL UNIT...
Page 32
. Any number in the range of 1 to 8 can be set to the LEVEL No. This setting can be assigned to the respective level and can be mapped. 1-26 (E) SONY ROUTING SYSTEM SETUP MENU BKP-7933 V1.00 MODIFICATION COMMAND A: SET UNIT LOCATION(CAM-CCU)
When the SOURCE NAME is set for each camera number, the name can be output to the CNU character displays (from page 2 to page 11) of the CNU-700 with BKP-7933 installed. Setting from the S-BUS Primary Station 1.
Page 34
Displaying the SOURCE NAME on the CNU Character Display 1. Select the menu item “Z:BKP-7933 CONFIGURA- TION” and press [ENTER]. 2. Select “H: BKP-7933 MODE” using the cursor key and press [ENTER]. 3. Select “SOURCE NAME” of “3 CAMERA No” with the cursor key and press [ENTER].
. Refer to the installation manual of the Tally Interface Unit BKDS-7700, Section 3-2-4, “Tally Configu- ration” for details of the tally system. Connecting Peripheral Equipment PRIMARY STATION CNU-700 REMOTE with BKP-7933 S-BUS CCU 1 to 6 CCA-5 CABLE REMOTE RCP/CNU...
Page 36
1-7. Setting Up Setting from the S-BUS Primary Station 1. Select the menu item “Z:BKP-7933 CONFIGURA- TION” and press [ENTER]. 2. Select “G: S-BUS TALLY” using the cursor key and press [ENTER]. 3. Move the cursor key to the desired position to be changed and press [ENTER].
Page 37
5. Return to the previous screen by pressing [Ctrl] - [E], and select the menu item “H:BKP-7933 MODE”. 6. Set the “1 SBUS TALLY SYSTEM” to the ON position using the cursor key and press [ENTER]. The tally system can be turned on and off using this menu.
Setting from the S-BUS Primary Station 1. Select the menu item “Z:BKP-7933 CONFIGURA- TION” and press [ENTER]. 2. Select the menu item “H: BKP-7933 MODE” and press [ENTER]. 3. Set the “4 DIAGNOSIS DISPLAY” to the ON posi- tion using the cursor key and press [ENTER].
RESET switch S1. All data is initialized in about five seconds. 4. Set the switch S5 to the factory default position. BKP-7933 SONY ROUTING SYSTEM SETUP MENU A: SET UNIT LOCATION(CAM-CCU) C: SET UNIT LOCATION(MSU) K: RESET TO DEFAULT TABLE...
An example of connecting 13 or more cameras is shown below. Two CNU-700s are necessary for connecting 13 or more cameras. (To connect 19 or more cameras, two CNU-700s containing the CNU IF board BKP-7930 are necessary. If you want to connect 25 or more cameras, contact your local Sony Sales Office/Service Center.
C:\>edit autoexec.bat " PATH C:\;C: … ;c:\router 5. Save the AUTOEXEC.BAT file. Quit the edit command. 6. Remove the FD from the disk drive. 7. Use the Ctrl-Alt-Del key combination. The personal computer restarts. BKP-7933 1-8. Data Backup/Restore 1-35 (E)
For the details of the menu screen and the setting procedure in terminal mode, refer to the installation manual for system setup of ROUTING SWITCHER SYSTEM. For obtaining the installation manual of ROUTING SWITCHER SYSTEM, contact your local Sony Sales Office/Service Center.
Page 43
... Select a menu item [1,2,3,9]? 14. To back up the data of the BKP-7933, type “2”. (“2. The data of secondary stations” is selected.) The data is backed up in the FD. 15. Type “9” twice. (“9. Quit” is selected.) The backup mode is terminated.
... Select a menu item [1,2,3,9]? 4. To restore the data of the BKP-7933, type “2”. (“2. The data of secondary stations ” is selected.) 5. Type “9” twice. (“9. Quit” is selected.) The backup mode is terminated. 1-38 (E) Execution Menu ...To primary station...
However, version check of the ROM that is installed in the board of the RCP side, and modification of the board in the RCP are required. If you want to switch the video on the preview monitor using the RCP-740/741, contact your local Sony Sales Office/Service Center.
1-9-3. Modification of RCP-720 Required Part Description Sony P/N Jumper wire Modification Procedure 1. Connect the two jumper wires by soldering. (SW-754 board) Between pin-6/CN3 and D25 cathode (1) Between pin-5/CN3 and pin-2/S24 (2) 2. Disconnect CN101/CN-1187 board. Setting Switch on MPU-92 Board...
1-9. Modification of RCP 1-9-4. Modification of RCP-721 Required Parts Description Sony P/N Resistor, Chip Metal 82 Z 1-216-625-11 Jumper wire Modification Procedure (SW-752 Board) 1. Remove the resistors R10 and R55/SW-755 board. 2. Connect a metal resistor 82 Z to the soldering land of R10, by soldering.
1-9-5. Modification of RCP-730/731 Required Parts Description Sony P/N Resistor, Chip Metal 0 Z 1-216-295-11 Resistor, Chip Metal 82 Z 1-216-625-11 Modification Procedure (SW-893 Board) 1. Remove soldering of R1, R2, R3 and R12. 2. Connect metal resistors 0 Z to the soldering land of R4, R6 and R7 by soldering.
1-10. Using the BKP-7933 in the HD System 1-10. Using the BKP-7933 in the HD System Connecting Peripheral Equipment HD COLOR CAMERA HD CAMERA CONTROL UNIT HDCU-700A HDC-700A OPTICAL FIBER CABLE CAMERA COMMAND NETWORK UNIT CNU-700 1-10-1. Controlling the Routing Switcher via the RS-422A Interface The routing switcher can be controlled via the RS-422A interface.
Page 51
Set the control mode to the LOCAL MSU mode (LOCAL mode) using the MSU assignment menu. Refer to the BVP-900-series System Manual BKP-9901 (available separately) Section 3-4-3 “MSU Assignment” for the setting procedure. BKP-7933 MB-562 board CN12 B3 x 5 1-10. Using the BKP-7933 in the HD System 1-45 (E)
1-10. Using the BKP-7933 in the HD System 1-10-2. Controlling a Waveform Monitor A waveform monitor can be controlled from the MSU via the I/O PORT connector of the BKP-7933, by setting the switches on the IF-689 board of the BKP-7933.
Page 53
The wiring diagram can change depending on the system of the waveform monitor. HD ANALOG system 50P CONNECTOR (MALE) (WIRING SIDE) RECALL system 50P CONNECTOR (MALE) (WIRING SIDE) BKP-7933 1-10. Using the BKP-7933 in the HD System 15P CONNECTOR (MALE) (WIRING SIDE) THREE RECALL 0 RECALL 1 STORE CH 2...
Lights when the serial data is received from the REMOTE S-BUS connector D403 S-BUS TX Green Lights when the serial data is transmitted to the REMOTE S-BUS connector IF-689 board S-BUS RX TX 1-48 (E) D402 D403 S-BUS ID No. CNU GROUP No. (Component side/A side) BKP-7933...
Page 55
The material contained in this manual consists of information that is the property of Sony Corporation and is intended solely for use by the purchasers of the equipment described in this manual. Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any...