Summary of Contents for Mitsubishi Electric FR-A7AR
Page 1
INVERTER Plug-in option FR-A7AR FR-A7AR E kit INSTRUCTION MANUAL Relay output function PRE-OPERATION INSTRUCTIONS INSTALLATION AND WIRING (FR-A700/F700 SERIES) INSTALLATION AND WIRING (FR-E700 SERIES (E kit)) RELAY OUTPUT...
Page 2
Thank you for choosing this Mitsubishi Electric inverter plug-in SAFETY INSTRUCTIONS option. This Instruction Manual provides handling information and precautions for use of this product. Incorrect handling might 1. Electric shock prevention cause an unexpected fault. Before using this product, read all WARNING relevant instruction manuals carefully to ensure proper use.
Page 3
3. Additional instructions CAUTION The following instructions must be also followed. If this product is handled incorrectly, it may cause unexpected fault, an injury, or an As all parameters return to their initial values after Parameter clear electric shock. or All parameter clear is performed, the needed parameters for 1) Transportation and installation operation of the inverter and this product must be set again before...
— CONTENTS — 1 PRE-OPERATION INSTRUCTIONS Unpacking and Product Confirmation .....................1 1.1.1 Packing confirmation (FR-A700/F700 series)....................1 1.1.2 Packing confirmation (FR-E700 series (E kit)) ....................2 Parts ..............................3 Specifications.............................4 2 INSTALLATION AND WIRING (FR-A700/F700 SERIES) Pre-Installation Instructions ......................5 Installation Procedure ........................6 Wiring..............................8 3 INSTALLATION AND WIRING (FR-E700 SERIES (E kit)) Pre-Installation Instructions ......................11...
Page 5
APPENDIX Appendix 1 Instructions for compliance with the EU Directives ............26 Appendix 2 Instructions for EAC ......................27 Appendix 3 Restricted Use of Hazardous Substances in Electronic and Electrical Products..28 Appendix 4 Referenced Standard (Requirement of Chinese standardized law) ......29...
PRE-OPERATION INSTRUCTIONS Unpacking and Product Confirmation Take the plug-in option out of the package, check the product name, and confirm that the product is as you ordered and intact. This product is a plug-in option dedicated for the FR-A series. 1.1.1 Packing confirmation (FR-A700/F700 series) Check the enclosed items.
PRE-OPERATION INSTRUCTIONS Specifications (1) Types of output signal 1 changeover contact output (three relays are provided) (2) Contact capacity 230VAC ..0.3A 30VDC .... 0.3A CAUTION • The contacts should be used within the rated capacity to prevent contacts weld resulting from faster contacts wearing.
INSTALLATION AND WIRING (FR-A700/F700 SERIES) Pre-Installation Instructions Make sure that the input power of the inverter is off. CAUTION With input power on, do not install or remove the plug-in option. Otherwise, the inverter and plug-in option may be damaged. For prevention of damage due to static electricity, touch nearby metal before touching this product to eliminate static electricity from your body.
INSTALLATION AND WIRING (FR-A700/F700 SERIES) Installation Procedure 1)Remove the inverter front cover. 2)Mount the hex-head screw for option mounting into the inverter screw hole (on earth plate). (size 5.5mm, tightening torque 0.56Nm to 0.75Nm) 3)Securely fit the connector of the plug-in Screw hole for option mounting option to the inverter connector along...
Page 12
INSTALLATION AND WIRING (FR-A700/F700 SERIES) CAUTION When used with other plug-in options, always connect the FR-A7AR to the connector 1 to prevent malfunction. Only one type of option per inverter may be used. When two or more options are mounted, priority is in ...
INSTALLATION AND WIRING (FR-A700/F700 SERIES) Wiring (1) Wire the shielded twisted pair cable after stripping its sheath to make its Shield (perform protective treatment) cables loose. Sheath Also, protect the shielded cable of the shielded twisted pair cable to ensure that it will not make contact with the conductive area. Strip the signal wires as shown below.
Page 14
INSTALLATION AND WIRING (FR-A700/F700 SERIES) REMARKS • Information on crimp terminals Commercially available product examples (as of Jan. 2017) Wire gauge Ferrule part No. Terminal Maker screw size With insulation sleeve Without insulation sleeve AI 0,34-6TQ A 0,34-7 Phoenix Contact AI 0,5-6WH A 0,5-6 Co.,Ltd.
Page 15
INSTALLATION AND WIRING (FR-A700/F700 SERIES) (3) For wiring of the inverter with one front cover, route wires between the control circuit terminal block and front cover. If cables can not be routed between the control circuit terminal block and front cover due to the increased number of cables, remove a hook of the front cover and use a space become available.
INSTALLATION AND WIRING (FR-E700 SERIES (E kit)) Pre-Installation Instructions Make sure that the input power of the inverter is off. CAUTION With input power on, do not install or remove the plug-in option. Otherwise, the inverter and plug-in option may be damaged. For prevention of damage due to static electricity, touch nearby metal before touching this product to eliminate static electricity from your body.
Page 17
INSTALLATION AND WIRING (FR-E700 SERIES (E kit)) For FR-E720-3.7K (FR-E720-175) or less, FR-E740-7.5K (FR-E740-170) or less (1) Remove the front cover from the inverter. (For removing the front cover, refer to the FR-E700 series instruction manual.) (2) Remove the PU cover from the front cover. Open the PU cover with a driver, etc. and remove it in the direction of arrow as shown below.
Page 18
(2). (8) When wiring to the plug-in option is completed, install the front cover for plug-in option to the inverter. Insulation sheet (Available only Front cover for FR-A7AR) for plug-in option plug-in option Option connector (7) Replace...
Page 19
Installation of an insulation sheet For FR-A7AR, put an insulation sheet under the screw platform of inverter (A of the following figure) and fit the insulation sheet to the screw position on the inverter side (B of the following figure).
Page 20
INSTALLATION AND WIRING (FR-E700 SERIES (E kit)) For FR-E720-5.5K (FR-E720-240) or more, FR-E740-11K (FR-E740-230) or more (1) Remove the front cover 1 and 2 from the inverter. (For removing the front cover, refer to the FR-E700 series instruction manual.) (2) Remove the PU cover from the front cover 2.
Page 21
INSTALLATION AND WIRING (FR-E700 SERIES (E kit)) (4) Correctly install the insulating sheet between the inverter and plug-in option. (Refer to page installation method of an insulation sheet.) (5) Securely fit the connector of the plug-in option to the inverter connector along the guides. (6) Securely fix the both top and bottom of the plug-in option to the inverter with the accessory mounting screws.
INSTALLATION AND WIRING (FR-E700 SERIES (E kit)) Wiring (1) Wire the shielded twisted pair cable after stripping its sheath to make its Shield (perform protective treatment) cables loose. Sheath Also, protect the shielded cable of the shielded twisted pair cable to ensure that it will not make contact with the conductive area.
Page 23
INSTALLATION AND WIRING (FR-E700 SERIES (E kit)) REMARKS • Information on crimp terminals Commercially available product examples (as of Jan. 2017) Wire gauge Ferrule part No. Terminal Maker screw size With insulation sleeve Without insulation sleeve AI 0,34-6TQ A 0,34-7 Phoenix Contact Al 0,5-6WH A 0,5-6...
Page 24
INSTALLATION AND WIRING (FR-E700 SERIES (E kit)) (3) When wiring the FR-E700 series, if a hook of the front cover for the plug-in option impedes wiring, cut off the hook and perform wiring. Cut off with a nipper, etc. Cut off a hook at the bottom of the option cover.
You can select any three output signals (RUN, SU, FU, etc.) available with an inverter as standard, and output them as relay contact signals. Refer to page 22, 24 of the Instruction Manual (detailed) for details. The following is the internal block diagram of the FR-A7AR. Connector Controller...
RELAY OUTPUT Output Signal List (FR-A700/F700 series) For details of signal definitions, refer to Pr. 190 to Pr. 196 (Output terminal function selection) of the inverter (FR-A700/F700 series) manual. Setting Setting Signal Signal Function Positive Function Positive Name Name logic logic Brake opening request Inverter running...
Page 28
RELAY OUTPUT Setting Setting Signal Signal Function Function Positive Positive Name Name logic logic During PID control activated DC current feeding During retry Control circuit capacitor life SLEEP PID output interruption Main circuit capacitor life Commercial-power supply side motor 1 Cooling fan life connection RO1 Inrush current limit circuit life...
RELAY OUTPUT Output Signal List (FR-E700 series) For details of signal definitions, refer to Pr. 190 to Pr. 192 (Output terminal function selection) of the inverter (FR-E700 series) manual. Setting Setting Signal Signal Function Positive Function Positive Name Name logic logic Fan fault output Inverter running...
Connection Diagram When Using Electronic Bypass Sequence Function (FR-A700/F700 series) When using the electronic bypass sequence function with the FR-A7AR mounted to the FR-A700/F700 series inverter, it is recommended to use either connection shown below. (1) Recommended connection example 1...
CE marking. The authorized representative in the EU The authorized representative in the EU is shown below. Name: Mitsubishi Electric Europe B.V. Address: Mitsubishi-Electric-Platz 1, 40882 Ratingen, Germany Note • To use this product in the EU, the operating capacity of the relay outputs should be 30 VDC, 0.3 A. (Relay output has basic isolation from the inverter internal circuit.)
9, X (October), Y (November), or Z (December). • Authorized sales representative (importer) in the CU area The authorized sales representative (importer) in the CU area is shown below. Name: Mitsubishi Electric (Russia) LLC Address: 52, bld 1 Kosmodamianskaya Nab 115054, Moscow, Russia Phone: +7 (495) 721-2070...
APPENDIX Appendix 3 Restricted Use of Hazardous Substances in Electronic and Electrical Products The mark of restricted use of hazardous substances in electronic and electrical products is applied to the product as follows based on the “Management Methods for the Restriction of the Use of Hazardous Substances in Electrical and Electronic Products”...
APPENDIX Appendix 4 Referenced Standard (Requirement of Chinese standardized law) This Product is designed and manufactured accordance with following Chinese standards. EMC: GB/T 12668.3 IB(NA)-0600166ENG-E...
Page 35
REVISIONS *The manual number is given on the bottom left of the back cover. Print Date *Manual Number Revision May, 2004 IB(NA)-0600166ENG-A First edition Dec., 2004 IB(NA)-0600166ENG-B Partial modification Board shape change Addition Compatible with the FR-F700-NA series Sep., 2005 IB(NA)-0600166ENG-C Addition Compatible with the FR-A700 series...
Page 36
INVERTER HEAD OFFICE: TOKYO BUILDING 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN IB(NA)-0600166ENG-E (1903) MEE Printed in Japan Specifications subject to change without notice.