  • Page 1 B R U K S A N V I S N I N G K Ä Y T T Ö O H J E G E B R U I K E R S H A N D L E I D I N G RAIS Q-Tee RAIS Q-Tee Wall RAIS Q-Tee Insert...
  • Page 2: Stand

    Utiliser seulement les combustibles recommandés. Hergestellt für /Produced for: Hergestellt für /Produced for: ATTIKA FEUER AG, Brunnmatt 16, CH-6330 Cham / RAIS A/S, Industrivej 20, DK-9900 Frederikshavn ATTIKA FEUER AG, Brunnmatt 16, CH-6330 Cham / RAIS A/S, Industrivej 20, DK-9900 Frederikshavn 15a B-VG...
  • Page 3 Brug af brændeovn / Using the wood burning stove / Bruk av peisovn Använda kaminen / Tulisijan käyttäminen / Utilisation du poêle / Gebruik van de kachel Position 1 Position 2 Position 3 Posisjon 1 Posisjon 2 Posisjon 3 Asento 1 Asento 2 Asento 3 Stand...
  • Page 4: Revision

    English RAIS/ - User manual for Q-Tee FIRE ENVIRONMENTALLY FRIENDLY! 5 Eco-friendly advices for sensible heating - common sense both environmentally and economically. 1. Effective lighting. Use dry brushwood, kindling and possible a piece of news paper. Open the air damper, so plenty of air is fed to the stove and the gases from the heated wood can burn rapidly.
  • Page 5: Table Of Contents

    PLACEMENT OF Q-TEE WALL ............... 16-17 NORMAL SET-UP - CORNER SETTING ..............16 INSTALLATION DISTANCE IN CASE OF NON-COMBUSTIBLE WALL ......17 MOUNTING OF WALL BRACKET AND INSTALLATION OF Q-TEE WALL ... 18-19 Q-TEE INSERT ....................20-25 OVERALL DIMENSIONS ..................20 ASSEMBLY INSTRUCTIONS ..................21 BUILT-IN DIMENSIONS - WALL OPENING - AIR SYSTEM ........22...
  • Page 6: Introduction - Warranty

    Warranty Your RAIS wood burning stove comes with a 5 year warranty. The warranty, however, does not cover heat-insulating materials, glass and seals. Any alterations made to the stove will void the warranty.
  • Page 7: Specifications

    English RAIS - Manual for RAIS Q-Tee Specifications...
  • Page 8: Installation Instructions

    English RAIS - Manual for RAIS Q-Tee Installation instructions The following pages give instructions for the safe and proper installation of this heat- ing appliance in the UK. These instructions cover the basic principles of installation, although detail may need slight modification to suit particular local site conditions. In...
  • Page 9: Convection

    RAIS - Manual for RAIS Q-Tee Convection RAIS stoves are convection stoves. This means that the stove’s back and side panels are not over-heated. Convection means that there is a circulation of air, which ensures that the heat is distributed more evenly throughout the entire room. The cold air is sucked in at the base of the stove up through the convection channel, which runs along the stove’s combustion chamber.
  • Page 10 English RAIS - Manual for RAIS Q-Tee A single wall metal fluepipe is suitable for connecting the stove to the chimney but is not suitable for using for the complete chimney. The chimney and connecting fluepipe must have a minimum diameter of 125 mm. Any bend in the chimney or connecting fluepipe should not exceed 45°.
  • Page 11: Installation

    The wall bracket (accessory) is fitted with suitable bolts. When you choose where to set up your RAIS wood burning stove, you should consider the heat distribution to the other rooms. This will enable you to get the best use out of your stove.
  • Page 12: Change Of Chimney Connection

    English RAIS - Manual for RAIS Q-Tee Change of chimney connection The stove is delivered ready for top outlet, but may be changed to back outlet in the following way: Strike out the knock out plate at the rear of stove.
  • Page 13: Installation Distance In Case Of Combustible Wall

    English RAIS - Manual for RAIS Q-Tee Installation distance in case of combustible wall To find out whether the wall next to where the stove is going to be installed is flam- mable, you should contact your building contractor or the local building authorities.
  • Page 14: Placement Of Q-Tee 57/Q-Tee 65/Q-Tee 85 (Free-Standing)

    English RAIS - Manual for RAIS Q-Tee Placement of Q-Tee 57 / Q-Tee 65 / Q-Tee 85 (free-standing) Installation distance in case of combustible wall Normal set-up - corner setting Uninsulated flue Insulated flue A. Distance to furniture (min.) 650 mm 650 mm Distance to flammable materials (min.):...
  • Page 15: Corner Setting 45° Fixed Socket

    English RAIS - Manual for RAIS Q-Tee Corner setting 45° fixed socket Uninsulated flue Insulated flue A. Distance to furniture (min.) 650 mm 650 mm Distance to flammable materials (min.) B. in front (floor) 300 mm 300 mm C. to the side (floor)
  • Page 16: Placement Of Q-Tee Wall

    English RAIS - Manual for RAIS Q-Tee Placement of Q-Tee Wall Installation distance in case of non-combustible back wall and combustible side wall If the stove is to be installed above a wooden floor, it must be covered with a non-com- bustible material at a thickness and seize, which is in accordance with UK Building Regula- tions.
  • Page 17: Installation Distance In Case Of Non-Combustible Wall

    English RAIS - Manual for RAIS Q-Tee Installation distance in case of non-combustible wall We recommend a minimum distance to non-combustible material of 50 mm (F) for cleaning considerations. It should always be possible to access the access door. ...
  • Page 18: Mounting Of Wall Bracket And Installation Of Q-Tee Wall

    The stove can only be mounted on non-combustible walls without cracks. Contact the chimney sweep or building expert regarding the wall’s suitability. RAIS recommends that hanging and installation of RAIS Q-TEE WALL should only be done by authorized dealers. Remove the knock-outs for the wall bracket (1) and chimney (2) at rear of the stove (see section ‘Change...
  • Page 19 English RAIS - Manual for RAIS Q-Tee The stove is lifted up on the wall bracket and pushed against the wall until it falls in the “notch” (8). Examine that the top plate of the stove is leveled. If necessary, lift the stove from the wall and adjust the wall bracket.
  • Page 20: Q-Tee Insert

    English RAIS - Manual for RAIS Q-Tee Q-Tee INSERT Overall dimensions            ...
  • Page 21: Assembly Instructions

    (steel door), or with the door glass list (glass doors) in the closed position - if neces- sary, adjust the stove forward or backward. If desired, the cover can be provided in special outer dimensions. Contact your RAIS dealer. This can be ordered with the stove.
  • Page 22: Built-In Dimensions - Wall Opening - Air System

    English RAIS - Manual for RAIS Q-Tee Built-in dimensions - wall opening The wall opening is min. 613mm x 473mm (height x width). The depth is min. 475 mm (non-combustible panel) and min. 425mm (brick). A fireplace insert must never be built in tightly as steel expands during heating.
  • Page 23: Placement Of Q-Tee Insert

    There may be discoloration of the wall above the stove doors, and above the convection outlet holes. This is due to the ascending hot air. RAIS accepts no liability for installation or consequential damages.
  • Page 24: Installation Distance In Case Of Non-Combustible Panels

    English RAIS - Manual for RAIS Q-Tee Installation distance in case of non-combustible panels To guide the hot air out of the convection outlets RAIS recom- Min. convection area 600 cm above mends to mount a non-combustible plate above the outlets.
  • Page 25: Installation Distance In Case Of Brick Wall / Fire Wall

    Installation distance in case of brick wall / fire wall Min. convection area 600 cm above To guide the hot air out of the convection outlets RAIS recom- the stove (may be distributed) mends to mount a non-combustible plate above the outlets.
  • Page 26: For The Installer

    English RAIS - Manual for RAIS Q-Tee For the Installer Finally before firing the stove for the first time a check should be made to ensure that the assembly and stove installation has been satisfactory and that there are no leaks in any seals in the appliance and appliance connections to the chimney.
  • Page 27: Drying And Storage

    2-3 days before you need it. Regulating the combustion air All RAIS stoves are equipped with a one-handed operating lever for regulating the damper. The stove-specific regulating mechanisms can be seen on the diagrams. Primary air is the combustion air added to the primary combustion zone, i.e. the bed of glowing embers.
  • Page 28: Room Ventilation And Stoves

    English RAIS - Manual for RAIS Q-Tee By setting the interval between position 1 and 2, the energy content in the firewood is used optimally, as there is oxygen for combustion and for the burning of the pyrolysis gasses. When the flames are a clear yellow the damper has been set correctly. Finding the correct position comes with time after you have used for stove for a while.
  • Page 29: First Usage

    English RAIS - Manual for RAIS Q-Tee First usage A careful start pays off. Start with a small fire, so that the wood burning stove can get accustomed to the high temperature. This gives the best start and any damage is avoided.
  • Page 30: Warning

    Advarsel Advarsel English RAIS - Manual for RAIS Q-Tee Hvis brændet kun ulmer eller ryger, og der tilføres for lidt luft, udvikles der Hvis brændet kun ulmer eller ryger, og der tilføres for lidt luft, udvikles der Hvis brændet kun ulmer eller ryger, og der tilføres for lidt luft, udvikles der Warning!! uforbrændte røggasser.
  • Page 31: Cleaning And Care

    English RAIS - Manual for RAIS Q-Tee Cleaning and care Glass Most woodstoves use a ceramic glass product which is resistant to heat but requires cleaning to keep its appearance. Soot or opaque marks can easily cleaned if the marks are fresh, however If you leave...
  • Page 32: Cleaning Of The Flue Ways

    English RAIS - Manual for RAIS Q-Tee Cleaning of flue way The flue ways consist of a smoke converter plate and a smoke chicane. Both parts are made of vermaculit. Handle these parts carefully. Remove the smoke converter plate by tilting it to one side and turning it a little slant- wise.
  • Page 33: Interruption Of Operation

    - leaky chimney - leakage between chimney and flue If your stove continues to malfunction, we recommend that you contact your RAIS distributor or chimney sweep. IMPORTANT!! To ensure safe burning there must be clear yellow flames or clear em- bers at all times.
  • Page 34: Spare Parts Q-Tee

    RAIS - Manual for RAIS Q-Tee Spare parts Q-Tee If spare parts other than those recommended by RAIS are used, the warranty is voided. All replaceable parts can be bought as spare parts from your RAIS distributor. For reference see spare parts drawing Q-Tee (front of the user manual).
  • Page 35: Spare Parts

    English RAIS - Manual for RAIS Q-Tee Spare parts...
  • Page 39 ATTIKA FEUER AG Brunnmatt 16 CH-6330 Cham Switzerland www.attika.ch RAIS A/S Industrivej 20 DK-9900 Frederikshavn Denmark www.rais.dk...