HP 6127XLG Blade Switch Series FCoE Command Reference Part number: 797693-001 Software version: Release 2418P03 Document version: 6W100-20150806...
Page 2
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty.
Page 5
···································································································································································· 127 FC tracert commands ··················································································································································· 129 fctracert ································································································································································· 129 Support and other resources ·································································································································· 131 Contacting HP ······························································································································································ 131 Subscription service ············································································································································ 131 Related information ······················································································································································ 131 Documents ···························································································································································· 131 ...
FCoE commands FCoE mode commands display fcoe-mode Use display fcoe-mode to display the FCoE mode of the switch. Syntax display fcoe-mode Views Any view Predefined user roles network-admin network-operator Examples # Display the FCoE mode of the switch. <Sysname> display fcoe-mode The FCoE mode is NONE.
Page 7
Default A switch operates in non-FCoE mode. Views System view Predefined user roles network-admin Parameters fcf: Specifies the FCF mode. fcf-npv: Specifies the FCF-NPV mode. npv: Specifies the NPV mode. transit: Specifies the Transit mode. Usage guidelines An FC and FCoE-capable switch can operate in non-FCoE mode or in one of the following FCoE modes: •...
Related commands display fcoe-mode VFC interface commands bandwidth Use bandwidth to set the expected bandwidth for an interface. Use undo bandwidth to restore the default. Syntax bandwidth bandwidth-value undo bandwidth Default The expected bandwidth (in kbps) is the interface baud rate divided by 1000. Views VFC interface view Predefined user roles...
Page 9
Default A VFC interface is not bound to any Ethernet interface. Views VFC interface view Predefined user roles network-admin Parameters interface-type interface-number: Specifies an interface by its type and number. The interface type can only be one of the following: Layer 2 Ethernet interface.
Page 10
When you bind a VFC interface to an S-channel interface or S-channel aggregate interface, follow these restrictions and guidelines: To successfully bind a VFC interface to an S-channel interface or S-channel aggregate interface, • make sure the switch is operating in expert mode. For information about system operating modes, see Fundamentals Configuration Guide.
default Use default to restore the default settings for a VFC interface. Syntax default Views VFC interface view Predefined user roles network-admin Usage guidelines CAUTION: The default command might interrupt ongoing network services. Make sure you are fully aware of the impacts of this command when you execute it on a live network.
Parameters text: Specifies an interface description, a case-sensitive string of 1 to 255 characters. Usage guidelines The description helps users identify the role of an interface. Examples # Set the description to Vfcport1 for interface VFC 1. <Sysname> system-view [Sysname] interface vfc 1 [Sysname-Vfc1] description Vfcport1 Related commands display interface vfc...
Page 13
Current state: UP Line protocol state: UP Description: Vfc1 Interface Bandwidth: 10000000kbps Maximum Transmit Unit: 2112 Internet protocol processing: disabled Link layer protocol is FC Port WWN is 66:66:66:63:66:64:61:30 FC mode is E, state is E Support the VSAN protocol VSAN tagging mode is Tagging EVFP common VSAN: 1 Bound interface is FortyGigE1/1/1, Bound MAC is 000c-2933-eacd...
Page 14
Brief information on VFC interface(s): Admin Mode: auto - auto; E - e port; F - f port; NP - n port proxy Oper Mode: E - e port; F - f port; NP - n port proxy; TE - trunking e port; TF - trunking f port; TNP - trunking n port proxy Interface Admin Admin Oper Status Bind...
<Sysname> display interface vfc brief down Brief information on interface(s) under bridge mode: Link: ADM - administratively down; Stby - standby Interface Link Cause Vfc1 Administratively Table 5 Command output Field Description Brief information on interface(s) Brief information about Layer 2 interfaces. under bridge mode Link status: •...
Parameters e: Specifies the E mode. f: Specifies the F mode. np: Specifies the NP mode. Usage guidelines An FCF switch supports E and F modes. An NPV switch supports F and NP modes. An FCF-NPV switch supports E, F, and NP modes. On an FCF-NPV switch, if the mode of a VFC interface is not supported by a VSAN of the interface, the mode does not take effect in the VSAN.
Related commands display interface vfc reset counters interface Use reset counters interface to clear the statistics for VFC interfaces. Syntax reset counters interface [ vfc [ number ] ] Views User view Predefined user roles network-admin Parameters number: Specifies a VFC interface by its number in the range of 1 to 1024. Usage guidelines Clear the existing statistics before collecting traffic statistics within a specific period of time on an interface.
fcoe fka-adv-period • • fcoe global fcf-priority display fcoe vlan Use display fcoe vlan to display the FCoE configuration of a VLAN. Syntax display fcoe vlan vlan-id Views Any view Predefined user roles network-admin network-operator Parameters vlan vlan-id: Specifies a VLAN by its ID in the range of 1 to 4094. Usage guidelines Only FCF-NPV switches support this command.
fcoe enable Use fcoe enable to enable FCoE in a VLAN and map the VLAN to a VSAN. Use undo fcoe enable to disable FCoE in a VLAN. Syntax fcoe enable [ vsan vsan-id ] undo fcoe enable Default FCoE is disabled in a VLAN. Views VLAN view Predefined user roles...
Syntax fcoe fcf-priority priority undo fcoe fcf-priority Default The FCF priority of a VFC interface is 128. Views VFC interface view Predefined user roles network-admin Parameters priority: Specifies the FCF priority for the VFC interface, in the range of 0 to 255. The smaller the value, the higher the priority.
Usage guidelines On FCF or NPV switches, you can set an FC-MAP value only in system view. On FCF-NPV switches, you can set an FC-MAP value only in VLAN view. An FC-MAP value identifies an FCoE network. Switches in the same FCoE network must have the same FC-MAP value.
Page 23
The switch sends unsolicited Discovery Advertisements every FKA advertisement interval out of its VFC interfaces in E mode. The FKA advertisement interval value is carried in unsolicited Discovery Advertisements. After receiving an unsolicited Discovery Advertisement, the peer switch maintains the status of the virtual link and records the FKA advertisement interval value.
[Sysname-vlan2] fcoe fka-adv-period 20 fcoe global fcf-priority Use fcoe global fcf-priority to set the system FCF priority. Use undo fcoe global fcf-priority to restore the default. Syntax fcoe global fcf-priority priority undo fcoe global fcf-priority Default The system FCF priority is 128. Views System view, VLAN view Predefined user roles...
Syntax display vsan [ vsan-id ] port-member Views Any view Predefined user roles network-admin network-operator Parameters vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. If you do not specify this argument, this command displays the member interfaces of each VSAN. Examples # Display the member interfaces of each VSAN.
1 to 3839. The value for vsan-id2 must be greater than or equal to the value for vsan-id1. Usage guidelines HP recommends not including both FCF-mode VSANs and NPV-mode VSANs on an FCF-NPV switch in a VSAN list. If you do so, the following events occur during trunk mode negotiation: An E_Port selects only FCF-mode VSANs.
An NP_Port selects only NPV-mode VSANs. • Examples # Assign interface VFC 1 to VSANs 1, 2, 10, and 20 through 100. <Sysname> system-view [Sysname] interface vfc 1 [Sysname-Vfc1] port trunk vsan 1 to 2 10 20 to 100 vsan Use vsan to create a VSAN and enter VSAN view.
Examples # Create VSAN 10 and enter its view. <Sysname> system-view [Sysname] vsan 10 [Sysname-vsan10] # Change the name of VSAN 10 from its default to FCF-VSAN. <Sysname> system-view [Sysname] vsan 10 name FCF-VSAN [Sysname-vsan10] # Create VSAN 1 1 with a name of FCF-VSAN, and enter the view of VSAN 1 1. <Sysname>...
A VSAN operating in FCF mode acts as an FCF switch. A VSAN operating in NPV mode acts as an NPV switch. If the configured mode of an interface is not supported by a VSAN of the interface, the mode does not take effect in the VSAN.
Otherwise, the non-principal switch refuses the assigned domain ID and isolates its interface connected to the principal switch. HP recommends that you configure the same allowed domain ID list on all switches in a VSAN. Examples # Configure VSAN 1 to allow domains 3 through 10.
Field Description Interface Local VFC interface. display fc domain-list Use display fc domain-list to display the list of domain IDs dynamically assigned in VSANs. Syntax display fc domain-list [ vsan vsan-id ] Views Any view Predefined user roles network-admin network-operator Parameters vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839.
Related commands domain configure enable display fc ess Use display fc ess to display the Exchange Switch Support (ESS) negotiation result, including the following information: • The capabilities of the local switch after the ESS negotiation. The capabilities of the remote switch after the ESS negotiation. •...
Table 12 Command output Field Description Domain Domain ID of the switch. Directory Server Capability List of directory server capabilities. Indicates whether the switch supports accepting large name server objects (yes for supported and no for not supported). Accept large name server objects A large name server object contains the symbolic name of the N_Port and the symbolic name of the node in addition to the information of a small name server object.
Usage guidelines Only FCF and FCF-NPV switches support this command. Examples # Display the node login information of VSAN 1. <Sysname> display fc login vsan 1 Interface VSAN FCID Node WWN Port WWN Vfc1 0x010000 21:01:00:1b:32:a0:fa:18 21:01:00:1b:32:a0:fa:17 # Display the number of logged-in nodes for VSAN 1. <Sysname>...
Page 36
Parameters vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. If you do not specify a VSAN, this command displays the name server database information of all VSANs. On an FCF-NPV switch, this command displays the name server database information of only VSANs operating in FCF mode. fcid fcid: Specifies an FC address.
Page 37
Port-type: 0x01(N) Fabric-port-WWN: 30:30:30:30:65:33:64:6 Hard-addr: 0x000000 VSAN:1 FCID: 0x030200 Port-WWN(vendor): 20:00:00:5a:c9:28:c7:01 Node-WWN: 10:00:00:5a:c9:28:c7:01 Class: 3 Node-IP-addr: 192.168.6.171 FC4-types(FC4_features): NPV Symbolic-port-name: NPV-Sysname:Vfc1 Symbolic-node-name: NPV-Sysname Port-type: 0x01(N) Fabric-port-WWN: 22:0a:00:05:30:00:26:1e Hard-addr: 0x000000 --- Total 2 entries --- Table 15 Command output Field Description FCID FC address of the N_Port.
Symbolic name, which is used for describing an N_Port. For an Symbolic-port-name NP_Port on an HP NPV switch, it is in the form of system-name:port-name. Symbolic name, which is used for describing a node. For an HP NPV Symbolic-node-name switch, it is the system-name. Port-type Link type of the N_Port, which can be N representing point-to-point.
Table 16 Command output Field Description SCR table for VSAN SCR list in a VSAN. FCID FC address of the N_Port. Type of Registered State Change Notification (RSCN) messages: • fabric detected rscns—Accepts all RSCN messages sent by the switches in the fabric.
resource-allocation: Specifies the resource allocation timeout period, in milliseconds. vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. If you do not specify a VSAN, this command displays global fabric timer information. Usage guidelines If you do not specify the distributed-services, error-detect, or resource-allocation keyword, this command displays all fabric timers.
[Sysname] vsan 1 [Sysname-vsan1] domain auto-reconfigure enable Related commands domain configure enable domain configure enable Use domain configure enable to enable the fabric configuration feature in a VSAN. Use undo domain configure enable to disable the fabric configuration feature in a VSAN. Syntax domain configure enable undo domain configure enable...
Parameters disruptive: Initiates a disruptive reconfiguration. If you do not specify this keyword, this command initiates a non-disruptive reconfiguration. Usage guidelines Only FCF switches and VSANs operating in FCF mode support this command. This command takes effect only when the fabric configuration feature is enabled. A fabric reconfiguration triggers a principal switch selection phase.
If a non-principal switch fails to get the configured static-type domain ID, it does not accept any • other domain ID and isolates the upstream principal link. HP recommends that you set domain IDs of the same type for all switches in the same VSAN. Examples # Specify static-type domain ID 55 in VSAN 1.
Parameters name: Specifies a fabric name, in the format of xx:xx:xx:xx:xx:xx:xx:xx, where x is a hexadecimal number. Usage guidelines Only FCF switches and VSANs operating in FCF mode support this command. An FCF switch supports assigning a fabric name to each VSAN, in the same format as the WWN (a 64-bit address).
[Sysname-Vfc1] fc domain rcf-reject vsan 1 fc name-service auto-discovery Use fc name-service auto-discovery to enable SCSI-FCP information autodiscovery. Use undo fc name-service auto-discovery to disable SCSI-FCP information autodiscovery. Syntax fc name-service auto-discovery undo fc name-service auto-discovery Default SCSI-FCP information autodiscovery is enabled. Views VSAN view Predefined user roles...
Default The global distributed service timeout period is 5000 milliseconds. Views System view Predefined user roles network-admin Parameters value: Specifies the distributed service timeout period in the range of 5000 to 10000 milliseconds. Usage guidelines The distributed service timeout period can be set in system view or VSAN view. The setting in system view takes effect on all VSANs.
The setting in system view takes effect on all VSANs. The setting in VSAN view takes effect only on the current VSAN. If you set the error detection timeout period both globally and for a VSAN, the setting for the VSAN takes precedence.
fc wwn default-fc4-type Use fc wwn default-fc4-type to configure the default FC4 information for a node. Use undo fc wwn default-fc4-type to delete the default FC4 information of a node. Syntax fc wwn wwn-value default-fc4-type { type-value feature feature-map | scsi-fcp feature { feature-map | both | initiator | target } } undo fc wwn wwn-value default-fc4-type { type-value | scsi-fcp } Default...
Examples # Configure the default FC4 information for the node with WWN 00:00:00:1 1:22:33:44:55. <Sysname> system-view [Sysname] fc wwn 00:00:00:11:22:33:44:55 default-fc4-type scsi-fcp feature target [Sysname] fc wwn 00:00:00:11:22:33:44:55 default-fc4-type 9 feature 7 priority Use priority to set the switch priority in a VSAN. Use undo priority to restore the default.
FC addressees of multiple nodes with changes in a single RSCN. This feature reduces the number of RSCNs sent to the concerned registered nodes. HP recommends that you enable RSCN aggregation and set the same RSCN aggregation timer value on all switches in a VSAN.
Only FCF switches and VSANs operating in FCF mode support this command. The RSCN aggregation timer takes effect only when RSCN aggregation is enabled. HP recommends that you enable RSCN aggregation and set the same RSCN aggregation timer value on all switches in a VSAN.
Examples # Enable SNMP notifications for domain ID changes. <Sysname> system-view [Sysname] snmp-agent trap enable fc-fabric domain-id-change # Enable SNMP notifications for fabric changes. <Sysname> system-view [Sysname] snmp-agent trap enable fc fabric-change snmp-agent trap enable fc-name-service Use snmp-agent trap enable fc-name-service to enable SNMP notifications for the name service module. Use undo snmp-agent trap enable fc-name-service to disable SNMP notifications for the name service module.
timer distributed-services Use timer distributed-services to set the distributed service timeout period for a VSAN. Use undo timer distributed-services to restore the default. Syntax timer distributed-services value undo timer distributed-services Default The distributed service timeout period is 5000 milliseconds. Views VSAN view Predefined user roles network-admin...
Views VSAN view Predefined user roles network-admin Parameters value: Specifies the error detection timeout period in the range of 1000 to 10000 milliseconds. Usage guidelines The error detection timeout period can be set in system view or VSAN view. The setting in system view takes effect on all VSANs. The setting in VSAN view takes effect only on the current VSAN.
If you set the resource allocation timeout period both globally and for a VSAN, the setting for the VSAN takes precedence. Examples # Set the resource allocation timeout period to 6000 milliseconds for VSAN 1. <Sysname> system-view [Sysname] vsan 1 [Sysname-vsan1] timer resource-allocation 6000 Related commands fc timer resource-allocation...
[Sysname-vsan1] wwn 33:e8:00:05:30:00:16:df area-port-id ab12 FC routing and forwarding commands display fc exchange Use display fc exchange to display the FC exchange entries. Syntax display fc exchange { link | protocol } [ slot slot-number ] display fc exchange link verbose [ slot slot-number [ exid exid ] ] Views Any view Predefined user roles...
Page 57
<Sysname> display fc exchange link slot 2 Local_ID:EXID Remote_ID:EXID State Slot Protocol 0x060501:1024 0x010001:1025 ESTABLISHED 2 # Display detailed information about the link exchange entries. <Sysname> display fc exchange link verbose slot 1 slot: 1 protocol: 8 connection info: Local = 0x090801:1155 , Remote = 0x050001:1089 PCB flags: 0x2 FC Class: FC_CLASS_F...
display fc fib Use display fc fib to display the FC FIB entries. Syntax display fc fib [ fcid [ mask-length ] ] vsan vsan-id Views Any view Predefined user roles network-admin network-operator Parameters fcid: Specifies a destination FC address in the range of 0x000000 to 0xFFFFFF (hexadecimal). mask-length: Specifies the mask length for the destination address, in the range of 0 to 24.
Destination count: 1 FIB entry count: 1 Destination/Mask Interface 0x030100/24 Vfc3 # Display the FC FIB entries for the specified FC address and mask length. <Sysname> display fc fib 030100 16 vsan 18 FC FIB information in VSAN 18: Destination count: 1 FIB entry count: 2 Destination/Mask Interface...
Page 60
mask-length: Specifies the mask length for the FC address. This argument is used together with the fcid argument. The value of this argument can be 8, 16, or 24. If you do not specify the mask length, this command displays the routing information for the FC address fcid with masks 8, 16, and 24. statistics: Displays the statistics for the FC routing table.
Page 61
Destination/mask: 0xfffffa/24 Protocol: DIRECT Preference: 0 Cost: 0 Interface: InLoop0 State: Active Age: 0h21m36s Destination/mask: 0xfffffc/24 Protocol: DIRECT Preference: 0 Cost: 0 Interface: InLoop0 State: Active Age: 0h21m36s Destination/mask: 0xfffffd/24 Protocol: DIRECT Preference: 0 Cost: 0 Interface: InLoop0 State: Active Age: 0h21m36s Table 19 Command output Field...
Table 20 Command output Field Description Protocol type: • DIRECT—Direct routes. Protocol • STATIC—Static routes. • FSPF—FSPF routes. route Number of routes of the specified protocol type. active Number of active routes of the specified protocol type. added Number of added routes of the specified protocol type. deleted Number of deleted routes of the specified protocol type.
Graceful-restart period : 120 seconds FSPF graceful restart information of VSAN 1: Number of neighbors under helper : 0 Number of restarting neighbors FSPF graceful restart information of VSAN 2: Number of neighbors under helper : 0 Number of restarting neighbors Table 21 Command output Field Description...
Examples # Display FSPF LSDB information. <Sysname> display fspf lsdb FSPF LSDB information of VSAN 1(01): Total LSR count: 2 FSPF Link State Database for Domain 01 LSR Type LSR Age LSR Incarnation number : 0x80000008 LSR Checksum : 0x7deb Number of links NbrDomainID IfIndex...
Page 65
Syntax display fspf neighbor [ vsan vsan-id ] Views Any view Predefined user roles network-admin network-operator Parameters vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. If you do not specify a VSAN, this command displays information about all FSPF neighbors.
Field Description Neighbor state: • Down—The neighbor does not start negotiation. • Init—The neighbor has started negotiation. • State DB_Exchange—The neighbor has been discovered. • DB_Wait—The local switch has sent the LSR. • DB_Ack_Wait—The neighbor has sent the LSR. • Full—Synchronization is complete.
Interface Vfc1 statistics: Type Input Output HELLO Table 24 Command output Field Description FSPF statistics for a VSAN. The value in parentheses is the domain ID in decimal FSPF statistics of VSAN of the local switch. SPF computing count Number of SPF calculations. Interface statistics Packet statistics on the interface.
Parameters fcid: Specifies the destination FC address of the static FC route, in the range of 0x010000 to 0xFFFFFF (hexadecimal). mask: Specifies a hexadecimal mask for the FC address. This argument is used together with the fcid argument. The value of this argument can be 0xFF0000, 0xFFFF00, or 0xFFFFFF. mask-length: Specifies the mask length for the FC address.
Parameters value: Specifies the FSPF cost in the range of 1 to 65535. vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. Usage guidelines Only FCF and FCF-NPV switches support this command. Each link has a cost. The route selection algorithm uses this value to determine the best route. The smaller the interface FSPF cost, the smaller the link cost.
[Sysname-Vfc1] fspf dead-interval 100 vsan 4 Related commands fspf hello-interval fspf enable Use fspf enable to enable FSPF in a VSAN. Use undo fspf enable to disable FSPF in a VSAN. Syntax fspf enable undo fspf enable Default FSPF is enabled after a VSAN is created. Views VSAN view Predefined user roles...
Usage guidelines Only FCF and FCF-NPV switches support this command. FSPF Graceful Restart (GR) ensures nonstop forwarding of traffic by backing up FSPF configuration information during a protocol restart (for example, the FSPF process restart triggered by the process command) or active/standby switchover. GR involves the following roles: •...
fspf graceful-restart • fspf graceful-restart interval Use fspf graceful-restart interval to set the maximum FSPF GR interval. Use undo fspf graceful-restart interval to restore the default. Syntax fspf graceful-restart interval interval-value undo fspf graceful-restart interval Default The maximum FSPF GR interval is 120 seconds. Views System view Predefined user roles...
Predefined user roles network-admin Parameters value: Specifies the hello interval in the range of 1 to 65534 seconds. vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. Usage guidelines Only FCF and FCF-NPV switches support this command. The hello interval specifies the time between the hello packets sent periodically by the switch to discover and maintain neighbor relationships.
Examples # Set the minimum LSR arrival interval for VSAN 2 to 10 seconds. <Sysname> system-view [Sysname] vsan 2 [Sysname-vsan2] fspf min-ls-arrival 10 fspf min-ls-interval Use fspf min-ls-interval to set the minimum LSR refresh interval for a VSAN. Use undo fspf min-ls-interval to restore the default. Syntax fspf min-ls-interval value undo fspf min-ls-interval...
Default The LSR retransmission interval is 5 seconds. Views VFC interface view Predefined user roles network-admin Parameters value: Specifies the LSR retransmission interval of the interface in seconds, in the range of 1 to 65535. vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. Usage guidelines Only FCF and FCF-NPV switches support this command.
Examples # Disable FSPF for interface VFC 1 in VSAN 4. <Sysname> system-view [Sysname] interface vfc 1 [Sysname-Vfc1] fspf silent vsan 4 fspf spf-hold-time Use fspf spf-hold-time to set the shortest SPF calculation interval in a VSAN. Use undo fspf spf-hold-time to restore the default. Syntax fspf spf-hold-time value undo fspf spf-hold-time...
Views User view Predefined user roles network-admin Parameters vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. If you do not specify a VSAN, this command clears the FSPF statistics for all VSANs. Usage guidelines Only FCF and FCF-NPV switches support this command.
display zone Use display zone to display zone information. Syntax display zone [ [ name zone-name ] vsan vsan-id ] Views Any view Predefined user roles network-admin network-operator Parameters name zone-name: Specifies a zone name, a case-sensitive string of 1 to 64 characters. A zone name can contain English letters (uppercase and lowercase), numbers, and special characters dollar sign ($), minus sign (-), caret (^), and underscore (_), and it must start with an English letter.
Field Description fwwn fWWN of the zone member. initiator Role of a zone member. If no role is indicated, the member has both roles. target Related commands member (zone view) • zone clone • zone name • • zone rename display zone member Use display zone member to display parent information for a zone member.
Page 80
Zones and zone aliases to which the specified zone member belongs. • • Zones to which the zone aliases belong. VSANs to which the zones and zone aliases belong. • If a zone alias is not assigned to any zones, only the parent VSANs are displayed for the zone alias. Examples # Display parent information for zone member with FC address as 010000 in VSAN 1.
Table 26 Command output Field Description fcid FC address of the zone member for which parent information is displayed. pwwn pWWN of the zone member for which parent information is displayed. fwwn fWWN of the zone member for which parent information is displayed. Related commands member (zone view) •...
Field Description Change Request Number of Distribution Request packets. Change Accept Number of Distribution Accept packets. Change Reject Number of Distribution Reject packets. Related commands reset zone statistics display zone status Use display zone status to display the zoning configuration and status. Syntax display zone status [ vsan vsan-id ] Views...
Mode: enhanced Default zone: permit Hard-zoning: enabled Full zoning database: Zonesets: 10, Zones: 20, Zone-aliases: 0 Status: distributing Table 28 Command output Field Description Mode Zone mode: basic or enhanced. Default zone policy: • Default zone deny—Deny members in the default zone from accessing each other. •...
Page 84
Predefined user roles network-admin network-operator Parameters name zone-alias-name: Specifies a zone alias name, a case-sensitive string of 1 to 64 characters. A zone alias name can contain English letters (uppercase and lowercase), numbers, and special characters dollar sign ($), minus sign (-), caret (^), and underscore (_), and it must start with an English letter. vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839.
display zoneset Use display zoneset to display zone set information. Syntax display zoneset [ [ name zoneset-name ] vsan vsan-id ] Views Any view Predefined user roles network-admin network-operator Parameters name zoneset-name: Specifies a zone set name, a case-sensitive string of 1 to 64 characters. A zone set name can contain English letters (uppercase and lowercase), numbers, and special characters dollar sign ($), minus sign (-), caret (^), and underscore (_), and it must start with an English letter.
Table 30 Command output Field Description fcid FC address of a zone member. pwwn pWWN of a zone member. Related commands member (zone set view) • • zoneset clone zoneset name • zoneset rename • display zoneset active Use display zoneset active to display information about the active zone set. Syntax display zoneset active [ vsan vsan-id ] Views...
Page 87
For a zone member that does not exist in the local name service database, only the configuration • content is displayed. Zone members cannot be displayed by zone alias in the active zone set. If a zone in the activated •...
*fcid 0x333333 [pwwn 33:33:33:33:33:33:33:33] zone name #default_zone# *fcid 0x20abcd *fcid 0xabcdef Table 31 Command output Field Description FC address of the zone member that can be queried from the local name *fcid service database. FC address of the zone member that does not exist in the local name service fcid database.
zone-alias zone-alias-name: Specifies an existing zone alias, a case-sensitive string of 1 to 64 characters. A zone alias name can contain English letters (uppercase and lowercase), numbers, and special characters dollar sign ($), minus sign (-), caret (^), and underscore (_), and it must start with an English letter.
Page 90
Syntax member { fcid fcid | fwwn fwwn | pwwn pwwn } [ initiator | target ] undo member { fcid fcid | fwwn fwwn | pwwn pwwn } Default No member exists in a new zone alias. Views Zone alias view Predefined user roles network-admin Parameters...
# Add an F_Port with fWWN 08:07:06:05:04:03:02:01 to zone alias za1 as both an initiator and a target. [Sysname-vsan2-zone-alias-za1] member fwwn 08:07:06:05:04:03:02:01 Related commands display zone-alias • • zone-alias name member (zone set view) Use member to add a zone to a zone set. Use undo member to remove a zone from a zone set.
pairwise-zoning enable Use pairwise-zoning enable to enable the Pairwise feature for a zone. Use undo pairwise-zoning enable to disable the Pairwise feature for a zone. Syntax pairwise-zoning enable undo pairwise-zoning enable Default The Pairwise feature is disabled for a zone. Views Zone view Predefined user roles...
member (zone alias view) • • zoneset activate zoneset distribute • reset zone statistics Use reset zone statistics to clear zone packet statistics. Syntax reset zone statistics [ vsan vsan-id ] Views User view Predefined user roles network-admin Parameters vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. If you do not specify a VSAN, this command clears zone packet statistics for all VSANs.
Parameters activation-completed: Enables SNMP notifications for zone set activation or deactivation. defaultzone-change: Enables SNMP notifications for default zone policy changes. hardzone-change: Enables SNMP notifications for hard zoning status changes. merge-failed: Enables SNMP notifications for merge failures. merge-succeeded: Enables SNMP notifications for merge successes. Usage guidelines Only FCF and FCF-NPV switches support this command.
[Sysname] vsan 1 [Sysname-vsan1] zone name z1 [Sysname-vsan1-zone-z1] quit # Create zone z2 by copying z1. [Sysname-vsan1] zone clone z1 z2 Related commands display zone • zone name • zone default-zone permit Use zone default-zone permit to allow members in the default zone to access each other. Use zone default-zone permit to deny members in the default zone from accessing each other.
zoneset distribute • zone hard-zoning enable Use zone hard-zoning enable to enable hard zoning in a VSAN. Use undo zone hard-zoning enable to disable hard zoning in a VSAN. Syntax zone hard-zoning enable undo zone hard-zoning enable Default Hard zoning is enabled in a VSAN. Views VSAN view Predefined user roles...
zone merge-control restrict Use zone merge-control restrict to set the merge control mode to Restrict in a VSAN. Use undo zone merge-control restrict to restore the default. Syntax zone merge-control restrict undo zone merge-control restrict Default The merge control mode is Allow. Views VSAN view Predefined user roles...
Syntax zone mode enhanced undo zone mode enhanced Default The basic zoning mode is enabled in a VSAN. Views VSAN view Predefined user roles network-admin Usage guidelines Only FCF switches and VSANs operating in FCF mode support this command. A zoning mode switchover causes a zone distribution to ensure zoning mode consistency across the fabric.
Predefined user roles network-admin Parameters zone-name: Specifies a zone name, a case-sensitive string of 1 to 64 characters. A zone name can contain English letters (uppercase and lowercase), numbers, and special characters dollar sign ($), minus sign (-), caret (^), and underscore (_), and it must start with an English letter. Usage guidelines Only FCF switches and VSANs operating in FCF mode support this command.
# Rename zone z1 as z2. [Sysname-vsan1] zone rename z1 z2 Related commands display zone • zone name • zone-alias clone Use zone-alias clone to create a zone alias by copying an existing zone alias. Syntax zone-alias clone src-name dest-name Views VSAN view Predefined user roles...
Use undo zone-alias name to delete a zone alias. Syntax zone-alias name zone-alias-name undo zone-alias name zone-alias-name Views VSAN view Predefined user roles network-admin Parameters zone-alias-name: Specifies the zone alias name, a case-sensitive string of 1 to 64 characters. A zone alias name can contain English letters (uppercase and lowercase), numbers, and special characters dollar sign ($), minus sign (-), caret (^), and underscore (_), and it must start with an English letter.
Usage guidelines Only FCF switches and VSANs operating in FCF mode support this command. Examples # Create zone alias za1. <Sysname> system-view [Sysname] vsan 1 [Sysname-vsan1] zone-alias name za1 [Sysname-vsan1-zone-alias-za1] quit # Rename zone alias za1 as za2. [Sysname-vsan1] zone-alias rename za1 za2 Related commands display zone-alias •...
Examples # Create zone z1. <Sysname> system-view [Sysname] vsan 1 [Sysname-vsan1] zone name z1 # Add an N_Port with the FC address as 010000 to zone z1. [Sysname-vsan1-zone-z1] member fcid 010000 [Sysname-vsan1-zone-z1] quit # Create zone set zs1. [Sysname-vsan1] zoneset name zs1 # Add zone z1 to zone set zs1.
<Sysname> system-view [Sysname] vsan 1 [Sysname-vsan1] zoneset name zs1 [Sysname-vsan1-zoneset-zs1] quit # Create zone set zs1 by copying zone set zs2. [Sysname-vsan1] zoneset clone zs1 zs2 Related commands • display zoneset zoneset name • zoneset distribute Use zoneset distribute to trigger a complete distribution, distributing both the active zone set and zone database.
Default The zone distribution and merge type is incomplete. Views VSAN view Predefined user roles network-admin Usage guidelines Only FCF switches and VSANs operating in FCF mode support this command. This command can be configured only in basic zoning mode. In enhanced zoning mode, the zone distribution and merge type is always complete, and this command is not supported.
Usage guidelines Only FCF switches and VSANs operating in FCF mode support this command. Examples # Create zone set zs1 and enter its view. <Sysname> system-view [Sysname] vsan 1 [Sysname-vsan1] zoneset name zs1 [Sysname-vsan1-zoneset-zs1] Related commands display zoneset zoneset rename Use zoneset rename to rename a zone set.
Table 32 Command output Field Description Name of the downlink interface. Server Interface External interface Name of the uplink interface mapped by the downlink interface. FCID FC address of the node. Port WWN Port WWN of the node connected to the NPV switch. Entries Number of logged-in nodes for a VSAN.
Page 109
Server Interfaces: Interface: Vfc5 VSAN tagging mode: Tagging VSAN State Down Number of Server Interfaces: 1 # Display the status information of interfaces in all VSANs. <Sysname> display npv status External Interfaces: Interface: Vfc1 VSAN tagging mode: Tagging VSAN State FCID 0x010003 Interface: Vfc2...
Field Description After an uplink interface goes up, the FC ID allocated by the core switch is displayed. A downlink interface does not have an FC ID. If an NPV switch is connected to two fabrics and its two uplink interfaces are assigned the same FC ID in a VSAN, one uplink interface can be up, but it cannot work as an uplink interface.
Use undo npv auto-load-balance enable to disable automatic load balancing in a VSAN. Syntax npv auto-load-balance enable undo npv auto-load-balance enable Default Automatic load balancing is disabled. Views VSAN view Predefined user roles network-admin Usage guidelines Only NPV switches and VSANs operating in NPV mode support this command. The automatic load-balancing process is as follows: The system starts a delay timer when it detects a new operational uplink interface.
Predefined user roles network-admin Parameters interval: Specifies a value for the delay timer, in the range of 1 to 300 seconds. Usage guidelines Only NPV switches and VSANs operating in NPV mode support this command. The delay timer helps reduce network flapping caused by up/down events of uplink interfaces. If the link layer state of uplink interfaces is stable, set the delay timer to a smaller value.
Views Any view Predefined user roles network-admin network-operator Parameters vlan vlan-id: Specifies a VLAN by its ID in the range of 1 to 4094. If you do not specify a VLAN, this command displays ENode information for all VLANs. Examples # Display ENode information obtained by the Transit switch.
Table 35 Command output Field Description Interface Ethernet interface connecting the Transit switch to the FCF switch. FCF MAC FCoE MAC address of the FCF switch. ENode Number of ENodes attached to an FCF switch. display fip-snooping flushing-rules Use display fip-snooping flushing-rules to display the FIP snooping rules that are being flushed. Syntax display fip-snooping flushing-rules [ enode | fcf ] [ vlan vlan-id ] Views...
fip-snooping enable Use fip-snooping enable to enable FIP snooping in a VLAN. Use undo fip-snooping enable to disable FIP snooping in a VLAN. Syntax fip-snooping enable undo fip-snooping enable Default FIP snooping is disabled. Views VLAN view Predefined user roles network-admin Usage guidelines To enable a VLAN on a Transit switch to process FCoE frames and FIP frames, enable FIP snooping in the...
Usage guidelines You can use the fcoe fcmap command to set the FC-MAP value in frames sent out of an FCF switch. You can use the fip-snooping fc-map command to set an FC-MAP value for a VLAN on a Transit switch. When an Ethernet interface in the FIP snooping VLAN receives a frame from the FCF switch, the following rules apply: If the FC-MAP value in the incoming frame is the same as the value set for the FIP snooping VLAN,...
<Sysname> system-view [Sysname] interface FortyGigE 1/1/2 [Sysname-FortyGigE1/1/2] fip-snooping port-mode fcf FCS commands fcs discovery start Use fcs discovery start to start a topology discovery in VSANs. Syntax fcs discovery start [ age interval ] vsan vsan-list Views System view Predefined user roles network-admin Parameters age interval: Specifies the aging time for the topology discovery information, in the range of 300 to...
Predefined user roles network-admin Parameters vsan vsan-list: Specifies a VSAN by its ID or a range of VSANs in the form of vsan-id to vsan-id. The value range for the vsan-id argument is 1 to 3839. Usage guidelines Only FCF and FCF-NPV switches support this command. Examples # Stop the topology discovery in VSAN 1 through VSAN 100.
: 0x01 Management address list : snmp://192.168.6.100 snmp://192.168.0.100 Fabric name : 10:01:00:11:22:00:01:01 Logical name : HP Information list : HP#HP 6127XLG Ethernet Blade Switch#Version 7.1.045, Release 2418P03 IE ports: Interface Port WWN Port type Attached port WWNs Vfc2 2f:15:01:11:22:00:01:01 F_Port...
Management address list : snmp://192.168.6.100 snmp://192.168.0.100 Fabric name : 10:00:00:11:22:00:01:01 Logical name : HP Information list : HP#HP 6127XLG Ethernet Blade Switch#Version 7.1.045, Release 2418P03 IE ports: Interface Port WWN Port type Attached port WWNs Table 39 Command output Field...
Page 124
Syntax display fcs ie [ vsan vsan-id ] [ nwwn wwn ] [ verbose ] Views Any view Predefined user roles network-admin network-operator Parameters vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. If you do not specify a VSAN, this command display the IE information in all VSANs.
Page 125
Management address list: snmp://192.168.6.100 snmp://192.168.0.100 Information list Vendor name : HP Model name/number: HP 6127XLG Ethernet Blade Switch Release code : Version 7.1.045, Release 2418P03 # Display the detailed IE information in all VSANs. <Sysname> display fcs ie verbose IE List for VSAN 1:...
Total 1 IEs in Fabric. Table 40 Command output Field Description The IE type can only be Switch. IE type Unknown is displayed for all other types. Name of the fabric where the IE resides. Fabric name Unknown indicates that the fabric name is not obtained from the IE. Device name of the IE.
Page 127
Examples # Display the port information for all VSANs. <Sysname> display fcs port Port List for VSAN 1: IE WWN: 10:00:00:11:22:00:01:01 Port WWN Port type Tx type Module type 2f:15:01:11:22:00:01:01 Unknown Shortwave Laser SFP with Serial ID 38:00:00:11:22:00:01:01 E_Port Shortwave Laser SFP with Serial ID Total 2 switch-ports in IE.
Page 128
Field Description Transmitter type of the port: • 10GBASE-CX4. • 10GBASE-ER 1550nm laser. • 10GBASE-EW 1550nm laser. • 10GBASE-LR 1310nm laser. • 10GBASE-LW 1310nm laser. • 10GBASE-LX4 WWDM 1300nm laser. Tx type • 10GBASE-SR 850nm laser. • 10GBASE-SW 850nm laser. •...
Field Description The supported speed can be one or more of the following options: • 1 Gbps. • 2 Gbps. • 4 Gbps. • 8 Gbps. Port speed capability • 10 Gbps. • 16 Gbps. • 20 Gbps. Unknown is displayed for speeds other than the preceding ones. The current speed can only be one of the following options: •...
Page 130
hba-id hba-id: Specifies an HBA by its ID in the format of xx:xx:xx:xx:xx:xx:xx:xx (hexadecimal). verbose: Displays detailed FDMI database information. If you do not specify this keyword, the command displays brief FDMI database information. Usage guidelines Only FCF and FCF-NPV switches support this command. Examples # Display the brief FDMI database information for all VSANs.
Page 131
OS name/version: Microsoft Windows Server 2003 R2 for x86 CT payload len: 2112 Port WWN: 21:00:00:c0:dd:13:cc:d5 Supported FC4 types: FCP Supported speed: 10Gbps Current speed: 10Gbps Maximum frame size: 2048 OS device name: S05131F Host name: S05131F Table 43 Command output Field Description Node WWN...
Field Description The current speed can only be one of the following options: • 1 Gbps. • 2 Gbps. • 4 Gbps. • 8 Gbps. • 10 Gbps. Current speed • 16 Gbps. • 20 Gbps. • 32 Gbps. • 40 Gbps.
Page 133
To abort the FC ping operation during the execution of this command, press Ctrl+C. Examples # FCping the address FFFC02 in VSAN 1. <Sysname> fcping fcid fffc02 vsan 1 FCPING fcid 0xfffc02: 128 data bytes, press CTRL_C to break. Reply from 0xfffc02: bytes = 128 time = 1.281 ms Reply from 0xfffc02: bytes = 128 time = 0.890 ms Reply from 0xfffc02: bytes = 128 time = 0.889 ms Reply from 0xfffc02: bytes = 128 time = 0.892 ms...
Field Description 5 packet(s) transmitted Number of echo requests sent. 5 packet(s) received Number of echo replies received. Percentage of packets not responded to the total number of 0.00% packet loss packets sent. round-trip min/avg/max = Minimum/average/maximum response time, in 0.889/0.969/1.281 ms milliseconds.
Page 135
20:00:00:05:30:00:18:db(0xfffcd7) 20:00:00:05:30:00:18:db(0xfffcd7) 20:00:00:0b:46:00:02:82(0xfffcd5) Fctracert completed. Table 45 Command output Field Description Route present for Path from a source to a destination. During the execution of the command, press Ctrl+C to abort the FC tracert press CTRL_C to break operation. 20:00:00:0b:46:00:02:82 WWN value.
Related information Documents To find related documents, browse to the Manuals page of the HP Business Support Center website: http://www.hp.com/support/manuals For related documentation, navigate to the Networking section, and select a networking category. •...
Conventions This section describes the conventions used in this documentation set. Command conventions Convention Description Boldface Bold text represents commands and keywords that you enter literally as shown. Italic Italic text represents arguments that you replace with actual values. Square brackets enclose syntax choices (keywords or arguments) that are optional. Braces enclose a set of required syntax choices separated by vertical bars, from which { x | y | ...
Page 138
Network topology icons Represents a generic network device, such as a router, switch, or firewall. Represents a routing-capable device, such as a router or Layer 3 switch. Represents a generic switch, such as a Layer 2 or Layer 3 switch, or a router that supports Layer 2 forwarding and other Layer 2 features.
Index A B D F I M N P R S T V W Z display interface vfc,7 display npv login,102 allowed-domain-id,24 display npv status,103 display npv traffic-map,105 display vsan port-member,19 bandwidth,3 display vsan status,20 bind interface,3 display zone,73 display zone member,74 default,6 display zone...