Page 1
DVS-9000/9000SF System (With CCP-9000 Series Center Control Panel) User’s Guide Production Switcher System [English] Volume 2 1st Edition Software Version 1.30 and Later...
Table of Contents Chapter 11 DME Operations Chapter 12 External Devices Basic Operation for External Device Control..........10 Saving Control Setting Data in Registers..........10 Amending Keyframes................11 Carrying Out Control of External Devices..........12 Control of P-BUS Devices ................14 Editing the P-BUS Timeline..............14 P-BUS Trigger..................16 Chapter 13 Keyframe Effects Sequence of Keyframe Operations..............20...
Page 4
Register Operations in the Menus...............46 Effect Status Display ................46 Effect Register Editing ................46 Chapter 14 Snapshots Snapshot Operations From the Numeric Keypad Control Block ....50 Saving and Recalling Snapshots............51 Snapshot Operations in the Menus .............55 Setting Snapshot Attributes ..............55 Snapshot Status Display ................57 Setting Key Snapshot Attributes ............58 Snapshot Register Editing ..............58 Chapter 15 Shot Box...
Page 5
Signal Output Settings (Output Menu)..........107 Settings Relating to Video Switching (Transition Menu) ....110 Settings Relating to Keys, Wipes and Frame Memory (Key/Wipe/FM Menu) ..................112 Settings Relating to Function Links (Link Menu).......114 Interfacing With External Devices (Device Interface Menu)....118 Setup Relating to DME ................123 Settings Relating to Signal Inputs (Input Menu).........123 Interfacing With External Devices (Device Interface Menu)....124 Setup Relating to DCU ................127...
Page 6
Chapter 18 DIAGNOSIS Appendix Wipe Pattern List ..................160 Standard Wipes..................160 Enhanced Wipes ..................161 Rotary Wipes ..................162 Mosaic Wipes ..................163 Random/Diamond Dust Wipes............165 DME Wipe Pattern List ................166 DME Wipe Patterns Available in One-Channel Mode .......166 DME Wipe Patterns Available in Two-Channel Mode.......170 Menu Tree ....................171 Recalling Menus..................171 M/E-1 to M/E-3 Menus ...............171...
Chapter 11 DME Operations Not supported in version 1.30.
Page 9
Chapter 12 External Devices Basic Operation for External Device Control ........10 Saving Control Setting Data in Registers ........10 Amending Keyframes..............11 Carrying Out Control of External Devices ........12 Control of P-BUS Devices ..............14 Editing the P-BUS Timeline............14 P-BUS Trigger .................
Basic Operation for External Device Control Use the Device menu to carry out operations for controlling external devices such as devices supporting P-BUS (Peripheral II protocol) (referred to as “P- BUS devices” in the manual), and VTRs. For VTRs only, you can also carry out operations using the device control block.
e: This register is empty in the selected region. E: This register is empty in all selectable regions. Press the [ENTER] button. This recalls the register you selected in step 4. In the Device menu, press VF2 ‘P-BUS Timeline.’ The Device>P-Bus Timeline menu appears. The status area shows a window for setting the action for the P-BUS device.
Press the [P-BUS] button in the numeric keypad control block, turning it on, to select the P-BUS region. Enter the number of the register to be recalled, with the numeric keypad buttons. Using the edit point specification buttons and fader lever in the keyframe control block, stop the effect on the desired edit point.
Page 13
To move to the first keyframe To move to the first keyframe, press the [REWIND] button in the keyframe control block. If an action is set for a rewind operation, then the action is carried out. (See “Setting an action for the rewind operation” (page 16).) Basic Operation for External Device Control...
Control of P-BUS Devices Editing the P-BUS Timeline This section describes how to set an action for a keyframe point, and edit the P-BUS timeline. Note Using the P-BUS timeline function requires the P-BUS control mode to be set to [Timeline]. Carry out this setting in the Engineering Setup>Panel>Device Interface menu.
Page 15
3: Recall 4: Trigger If in step 3 you selected 2 (Store), 3 (Recall), or 4 (Trigger), turn knob 3 to select the register number or trigger number. The indication for knob 3 changes to reflect the selection of Store, Recall, or Trigger.
Setting an action for the rewind operation In order that when recalling a P-BUS timeline, pressing the [REWIND] button in the keyframe control block moves to the first keyframe, an action setting must be made for this. In the Device>P-Bus Timeline menu, press [Rewind Action], and make the setting in the window that appears.
Page 17
Press the [P-BUS] button in the numeric keypad control block, turning it on, to select the P-BUS region. Enter the number of the register to be recalled with the numeric keypad buttons. Press the [ENTER] button in the numeric keypad control block. This carries out the Recall.
Sequence of Keyframe Operations The following table shows the principal operations involved in the sequence from creating keyframes to executing an effect. For details of each operation, see the page number in parenthesis. For an overview, see “Keyframes” in Chapter 1 (Volume 1). Recalling a register (see page 21) To create a new effect, recall an empty register;...
Recalling a Register Use the numeric keypad control block to recall a register. For each region there are 99 registers dedicated to keyframes, numbered from 1 to 99. When creating an effect as a user programmable DME, use a 3-digit register number which is commonly used for all DME regions (channels).
Page 22
Press the [EFF] button, turning it on. This allocates the numeric keypad control block to keyframe operations, and the [RCALL] button lights. Press the button corresponding to the region you want to select, turning it You can also press more than one button. [M/E 1], [P/P]: These select the corresponding M/E-1 and PGM/PST regions.
Specifying the Region and Edit Points Selecting the region in which editing applies Select the region in which the editing is applied by the effect consisting of keyframes, using the region selection buttons in the numeric keypad control block. (See step 2 in “Recalling a register” on the previous page.) Setting the edit points EDIT ENBL button CONST DUR button...
Page 24
• To move the edit point to a keyframe specified by number, press the [GO TO KF/TC] button, turning its LED on, then enter the keyframe number with the numeric keypad in the numeric keypad control block, and press the [ENTER] button to confirm.
Creating and Editing Keyframes For details of keyframe editing, see “Effect Editing” in Chapter 1 (Volume 1). Creation Creating new keyframes To create new keyframes, after recalling an empty register, use the following procedure to create and insert each new keyframe. Use the keyframe control block for carrying out the operation.
Insertion Inserting keyframes To insert a keyframe in an existing effect, use the following procedure in the keyframe control block. Press the [EDIT ENBL] button, turning it on. Stop the effect at the desired edit point. Create the image for the keyframe you want to insert. Press the [INS] button.
Page 27
Using image transformations or adding special effects, modify the keyframe. Press the [MOD] button. This modifies the keyframe. Modifying more than one keyframe simultaneously You can modify a number of keyframes simultaneously. There are three different cases for this operation. •...
Page 28
Press the [EDIT ENBL] button, turning it on. Stop the effect at any keyframe within the range to be modified. Carry out the necessary modifications. Press the [FROM TO] button, turning it on. The display in the numeric keypad control block shows the current keyframe number, followed by “TO.”...
Page 29
: Background A : Background B Effect execution Keyframe 1 Keyframe 2 Keyframe 3 Modify keyframe 2. (Changing the position of background B in the horizontal direction) Select keyframes 1 to 3 and modify simultaneously. Effect execution Keyframe 1 Keyframe 2 Keyframe 3 Result: The horizontal position of background B in keyframes 1 and 3 is now the same as that in keyframe 2.
Modifying the keyframes by holding down the [SHIFT] button and pressing the [MOD] button The modified parameter values are taken as relative values, which modify all of the selected keyframes. : Background A : Background B Effect execution Keyframe 1 Keyframe 2 Keyframe 3 Modify keyframe 2.
Press the [EDIT ENBL] button, turning it on. Stop the effect at the desired edit point. When the edit point is on a keyframe, this is what you delete. If the edit point is between two keyframes, the previous keyframe is what you delete. To delete a number of keyframes in a single operation, press the [FROM TO] button, turning it on.
Move the edit point to the position to which you want to move the keyframe. Press the [PASTE] button. This inserts the keyframe you have moved after the current keyframe. In constant duration mode, the moved keyframe overwrites the edit point. To insert the moved keyframe before a keyframe Hold down the [SHIFT] button, and press the [PASTE] button to insert the moved keyframe before the current keyframe.
Pause To apply a pause to a keyframe, use the following procedure. Press the [EDIT ENBL] button, turning it on. Stop the effect on the keyframe to which you want to apply a pause. Press the [PAUSE] button. This applies a pause to the specified keyframe. Undoing an Edit Operation To undo a keyframe insert, modify, delete, or paste operation immediately after execution, press the [UNDO] button.
Time Settings You can determine the execution time of an effect by setting either the keyframe durations or the effect duration. For details of keyframe duration and effect duration, see “Time Settings” in Chapter 1 (Volume 1). Setting the Keyframe Duration EDIT ENBL button KF DUR button EFF DUR button...
Setting the keyframe duration You can set the value of the keyframe duration independently for each keyframe, by the following method. Press the [EDIT ENBL] button, turning it on. Stop the effect on the keyframe for which you want to set the duration. The time from this keyframe to the following keyframe is what you set.
Using the numeric keypad in the numeric keypad control block, enter the timecode value for the effect duration, as a maximum of six digits. For example, to set 3 minutes 7 seconds and 15 frames, enter 30715. You can also use the [TRIM] button to enter a difference value. (See “Entering a difference value”...
Path Setting The term “path” refers to the specification of how interpolation is carried out from one keyframe to the next. For details of the notion of path, see “Paths” in Chapter 1 (Volume 1). Set keyframe paths in the Key Frame>Path menu. Accessing the Key Frame>Path menu In the top menu selection buttons of the menu control block, press [KEY FRAME], then select HF3 ‘Path.’...
Page 38
Changing the path type for Curve Use the following procedure. In the Path menu, press [M/E-1]. The M/E-1 menu appears. Press the Curve path type indication for the Key1 item that you want to change. A path selection window appears. Press the indication for the desired path type, to select it.
Page 39
The status area reflects the selected path type. At this point, depending on the setting for Curve, the effect for Hue and Xpt is also affected as shown in the following table. In the menu, the Hue and Xpt settings do not change, but the path type indication is dimmed out. Curve setting Hue change Xpt change...
Page 40
Press the indication for the desired path type, to select it. Xpt Hold off: When replaying a keyframe, change the inputs to the settings saved in memory. Xpt Hold on: When replaying a keyframe, do not change the inputs. Path Setting...
Executing Effects By means of the [RUN] button in the keyframe control block, you can play an effect as a continuously varying image. This is referred to as effect execution. See also “Effect Execution” in Chapter 1 (Volume 1). It is also possible to execute an effect from the device control block (see Chapter 2 (Volume 1)).
Executing an effect automatically Use the following procedure. Select the region in which you want to execute the effect, using the region selection buttons in the numeric keypad control block. (See step 2 (page 22) of “Recalling a register.”) With the numeric keypad, enter the number of the register in which the effect you want to execute is saved, and press the [ENTER] button to confirm.
Page 43
Press the [STOP NEXT KF] button, turning it on. Press the [RUN] button. This executes the effect as far as the next keyframe. When the [REV] button is lit, it is executed as far as the previous keyframe. Repeating an effect Use the following procedure.
Saving Effects When you recall an effect, the currently recalled effect is automatically saved in a register. This is referred to as the auto save function. You can disable the auto save function in a Setup menu. By means of the following operation, you can also specify a register and save an effect in it.
Page 45
To undo the saving of an effect Immediately after saving an effect, hold down the [STORE STATS] button and press the [UNDO] button to undo the save. Saving Effects...
Register Operations in the Menus Using the Effect menu, you can carry out the following effect register operations. • Status display • Register editing To display the Effect menu Press the top menu selection button [EFF] in the menu control block. Effect Status Display The Effect>Effect>Attribute menu displays the following information.
Page 47
register name, to display it in reverse video. To cancel a selection, press once more to return to the normal display. Note If you press a discontiguous register, this clears any previous selection. Be very sure to select the registers to be contiguous. When neither All nor Block is selected: You can use knob 1 to select a single register.
Snapshot Operations From the Numeric Keypad Control Block The term “snapshot” refers to a function whereby the various settings required to apply a particular effect to an image are saved in memory as a set of data, for recall as required, to recover the original state. For an overview of snapshots, see “Snapshots”...
Saving and Recalling Snapshots Snapshot operations with the numeric keypad control block use the following buttons. Display UNDO button SNAPSHOT button STORE STATS button SNAP SHOT DISS SHOT MASTR UNDO MCRO AUTO TRANS USER USER STORE TRANS STATS RATE TRIM STORE ENBL ENTER...
Page 52
Press the region selection button corresponding to the region for which you want to save, turning it on. You can select more than one region. [M/E 1], [P/P]: These select the corresponding M/E-1, and PGM/PST regions. [USER 1] , [USER 2]: These select the USER regions. [DME 1] to [DME 4]: These select DME channels.
Page 53
Press the [ENTER] button. This saves the snapshot, and the [STORE] button goes off. The [RCALL] and [STORE STATS] buttons light. To cancel a snapshot save operation After saving a snapshot, to cancel the save, hold down the [STORE STATS] button and press the [UNDO] button.
Page 54
Press the [ENTER] button. This recalls the specified snapshot, and the reference region name and recalled register number appear in the display. If you applied the effect dissolve or auto transition temporary attributes in step 4, the corresponding buttons go off. To cancel a snapshot recall operation After saving a snapshot, to cancel the recall, press the [UNDO] button.
Snapshot Operations in the Menus You can also set snapshot or key snapshot attributes in the Snapshot menu, which also displays the status of the registers. To access the Snapshot menu, press the top menu selection button [SNAPSHOT] in the menu control block. In the Snapshot menu, as well as setting snapshot attributes, you can carry out editing operations on snapshots, including copy and delete.
Page 56
To apply the cross-point hold attributes Press [Xpt Hold], turning it on. The Snapshot>Attribute>Xpt Hold menu appears. The status area shows a list of the currently selected regions and bus names. To select the desired register, press the register number or register name in the status area, or turn knob 2.
Snapshot Status Display The Snapshot>Attribute menu displays the following information. For details of how to access the Snapshot>Attribute menu, see page 55. Region name: The selected region name appears in the upper part of the list. Register number Register name Write-protected status: When the register is write-protected, an “L”...
When a GPI output is set: Displayed Attributes set character codes Port number GPI output is set for the port of the displayed number. Setting Key Snapshot Attributes Applying key snapshot attributes To apply an attribute to a key snapshot, use the following procedure. In the Snapshot menu, press VF5 ‘Key Snapshot’...
Page 59
• Copy: Copy the contents of one register to another register. • Move: Move the contents of one register to another register. • Swap: Swap the contents of two registers. • Delete: Delete the contents of a register. • Name: Attach a name to a register. Write-protecting the contents of the snapshot register Use the following procedure.
Page 60
Operation between regions Operation between regions is possible in the following cases. • Between the M/E-1 and P/P regions • Between the USER1 and USER2 regions • Betweeen two of the DME1 to DME4 (including Global) regions To select the desired registers, press on the register numbers or register names in the status area, or use the knobs.
Page 61
In the Snapshot menu, press VF2 ‘Snapshot’ and HF7 ‘Rename.’ The Snapshot>Snapshot>Rename menu appears. Using any of the following methods, select the snapshot register you want to name. • Press the desired register name in the register list. • Press the arrow keys to scroll the reverse video cursor. •...
Shot Box Register Creation The term “shot box” refers to a function whereby for each specified region any snapshot or keyframe effect can be recalled simultaneously. For each region, any snapshot or keyframe effect number can be specified to be recalled. There is also a setting to enable or disable the auto run function.
Page 65
Using any of the following methods, select the register you want to create (or edit). • In the status area, press the [No] or [Name] for the shot box register you want to select, then press [EDIT]. • Use knob 1 to specify the register, and press [Edit]. Knob Parameter Adjustment...
Page 66
To return to the state before saving the setting In the <Store> group, press [Undo]. To run the settings to check them In the <Recall> group, press [Recall], to run the shot box. Shot Box Register Creation...
Shot Box Execution You can recall (and run) shot box registers from the following control blocks. This section describes the various methods of operation. • Numeric keypad control block (see page 67) • Utility/shot box control block (see page 69) Shot Box Execution From the Numeric Keypad Control Block Display...
Page 68
In the numeric keypad control block, press the [SHOT BOX] button, turning it on. • This allocates the numeric keypad control block to shot box operations. • The [RCALL] button lights amber. • The display shows the last recalled register number. With the numeric keypad buttons, enter the desired register number.
Shot Box Execution in the Utility/Shot Box Control Block Bank selection buttons BANK BANK BANK BANK Memory recall buttons Utility/shot box control block (MKS-8033) In the utility/shot box control block, as the default setting the memory recall buttons have registers 1 to 96 allocated to banks 1 to 4. Bank Register allocation to memory recall buttons 1 to 24...
Page 70
Off: Register in which nothing is saved Lit orange: Register holding shot box settings Lit yellow: Last recalled register Press the memory recall button to which the shot box register you want to run is allocated. • The shot box execution is carried out. •...
Shot Box Register Editing You can carry out the following editing on shot box registers. • Lock: Write-protect the contents of the register. • Copy: Copy data from one register to another. • Move: Move data from one register to another. •...
Chapter 16 Engineering Setup Setup for the Whole System..............75 Network Settings (Network Config Menu) ........75 System Settings (System Config Menu).......... 76 Setting the Signal Format and Screen Aspect Ratio (Format Menu) ..............78 Selecting the State After Powering On (Start Up Menu) ....79 Reset and Initialization (Initialize Menu) ........
Page 74
Setup Relating to DCU ................. 127 Settings Relating to Signal Inputs (Input Config Menu) ....127 GPI Input Setting (GPI Input Assign Menu) ......... 128 Signal Output Settings (Output Config Menu)......130 GPI Output Setting (GPI Output Assign Menu)......132 Setup Relating to Router Interface and Tally........
Setup for the Whole System Carry out operations relating to setup in the Engineering Setup menu. To access the Engineering Setup menu, press the top menu selection button [ENG SETUP]. For an overview of setup, see “Setup” in Chapter 1 (Volume 1). Setting the unit ID When there are two switchers and connected DME units on the same network, it is necessary to set the unit ID on each device, as follows.
In the System>Network Config menu, press [Auto Config]. Turn the MKS-8010 System Control Unit off, then on again to restart the unit. This automatically checks all devices (excluding the DCU) connected to the Data LAN, and shows the results in the status area of the System>Network Config menu.
Page 77
Select the switcher to be controlled by the selected control panel, as follows. • If there is only one switcher on the network, in the <1st Switcher> group, set [SWR1] to ON, and in the <2nd Switcher> group, set [SWR2] to OFF.
In the <Setup Target> group, set the [System 1] or [System 2] button to ON, then carry out the setup. You can also set both to ON, and make the settings simultaneously on the two systems. Setting the Signal Format and Screen Aspect Ratio (Format Menu) To set the format, that is, the frame frequency and number of scan lines handled by each device, and the screen aspect ratio, use the System>Format menu.
In the System>Format>Active Line/Aspect menu, select one of the following from the <Screen Aspect> group. • 16:9 • 4:3 • Independ Set the screen aspect ratio separately for M/E, P/P, and USER on the switcher, and for each channel independently on the DME. If you selected [Independ] in step 1, select from the following.
Page 80
In the <Start Up Mode> group, select one of the following modes. Resume: When this is on, Resume mode is enabled. Custom: When this is on, Custom mode is enabled. For information about Resume mode and Custom mode, see “System Setup”...
After selecting the devices the settings apply to, in the System>Start Up menu, press [Initial Status Define]. A confirmation message appears. Press [Yes]. This saves the initial status settings other than the “setup” settings for the selected devices in non-volatile memory within the respective devices. Reset and Initialization (Initialize Menu) To carry out a reset or memory initialization for a device, use the System>Initialize menu.
Installation (Install Menu) To install software or firmware in a device, use the System>Install menu. To display the Install menu In the Engineering Setup menu, select VF1 ‘System’ and HF6 ‘Install.’ The status area shows the device ID of each device and the version of the installed software.
To display the Maintenance menu In the Engineering Setup menu, select VF1 ‘System’ and HF7 ‘Maintenance.’ In the status area, the current date and time, and details of the memory card appear. Setting the date and time For system date and time settings, use the following procedure. With the knobs, adjust the following parameters.
Page 84
Carrying out the primary setting To make the primary specification for a USB device, use the following procedure. In the System>Maintenance menu, using any of the following methods, select the USB device you want to set as primary. • Press directly on the list appearing in the status area. •...
Setup Relating to Operations From the Control Panel Overall Control Panel Settings (Config Menu) To carry out the overall control panel settings, use the Panel>Config menu. To display the Config menu In the Engineering Setup menu, select VF2 ‘Panel’ and HF1 ‘Config.’ The status area shows the “Bank numbers 1 to 4”...
Page 86
For the selected Bank number, in the <M/E Operation> group, select one of the following. Enable: Enable panel display and operation of the operating bank. Disable: Enable only panel display, and disable operation of the operating bank. Inhibit: Disable both the panel display and operation of the operating bank.
Page 87
Linking switcher buses and routing switcher buses To provide links between the switcher and routing switcher buses, make the following settings as required. Matrix selection: Select the target of link setting from the eight matrices (1 to Matrix position definition: Set the start address and level for the source and destination on the S-Bus.
Page 88
Using any of the following methods, define the position of the matrix to be linked. • Press directly on the list appearing in the status area. • Press the arrow keys to scroll the reverse video cursor. • Turn the knobs to make the setting. Knob Parameter Adjustment...
Page 89
The sources are reassigned, and this is reflected in the status area. To make link bus settings For the link number selected in the External Bus Link menu, use the following procedure. In the Panel>Config>External Bus Link menu, press [Link Bus Adjust]. The Link>Link Bus Adjust menu appears.
In the <Key Select> group, select the keyer to be linked to the transition of the master. Note Linking does not apply to a transition carried out with the downstream key control block. Cross-Point Settings (Xpt Assign Menu) To carry out the cross-point settings, use the Panel>Xpt Assign menu. To display the Xpt Assign menu In the Engineering Setup menu, select VF2 ‘Panel’...
Page 91
When assigning a video signal, press [Video] in the <Xpt> group. When assigning a key signal, press [Key]. Use any of the following operations to assign the signal. • Press directly on the list in the status area. • Press the arrow keys to move the reverse video cursor. •...
Page 92
can only carry out assignment of the video and key combinations in the Main table. You can select the table to be used for each of the following banks or buses. • M/E-1 and PGM/PST banks • Frame Memory Source 1/2 •...
Page 93
Knob Parameter Adjustment Setting values Sub Button No Sub cross-point button selection 1 to 128 • To disable operation of a button number, press [Inhibit]. Turn knob 3 to select the main cross-point button number to be assigned. Knob Parameter Adjustment Setting values Main Source No...
AUX Delegation Buttons Settings (Aux Assign Menu) To carry out the settings of the AUX delegation buttons in the Aux bus control block, use the Panel>Aux Assign menu. To display the Aux Assign menu In the Engineering Setup menu, select VF2 ‘Panel’ and HF3 ‘Aux Assign.’ The left side of the status area shows the delegation numbers, and the list of buses set;...
Press [Set] to confirm the selection. Setting the AUX delegation button shift operation To set the operation mode of the rightmost button in the row of AUX delegation buttons, select one of the following in the <Shift Mode> group of the Panel>Aux Assign menu.
Page 96
: Apply the trigger on a change in the polarity of the input signal. (Level): When the input is low or high, the specified signal format or screen aspect ratio applies. (See “Carrying out level settings” (page 120).) No Operation: Apply no trigger on an input pulse. In the <Target>...
Page 97
Carrying out level settings To set the low level and high level, first set the trigger type to “Level,” then use the following procedure. In the Panel>Device Interface menu, select the action to be set, and press [H/L Set]. The H/L Set menu appears. Using any of the following methods, select the settings.
Page 98
: The trigger causes the relay contacts to be shorted or drives the output low, and holds this state for the specified pulse width. : Each time the trigger occurs, the relay contacts are alternately closed or opened, or the output is switched between high and low.
Press [Action Set] to confirm the action selection. The selected setting appears in the status area. Test firing the trigger To test fire the trigger, press [Test Fire]. This outputs a trigger from the selected output port. This is not output when the trigger type is “Status.”...
Page 100
Make the following settings as required. Effect recall mode: To select the initial keyframe state when an effect is recalled, select [Recall] (do not display the first keyframe) or [Recall&Rewind] (display the first keyframe) in the <Recall Mode> group. Automatic effect saving: To automatically save an effected when it is recalled after being edited, turn [Effect Auto Save] on.
everything here is set to OFF, then pressing the [ALL] button does not change the specification of the next transition. Interchanging the [AUTO TRANS] and [CUT] buttons: To interchange the [AUTO TRANS] and [CUT] buttons in the transition control block, press the [Auto Trans/Cut Swap] button, turning it on. Transition preview operation mode: For the operation mode of the [TRANS PVW] button, select [Lock] or [Hold] in the <Trans Pvw>...
Page 102
LCD: Adjust the brightness of the source name displays. The following description takes the LCD brightness as an example. Use a similar process for the other adjustments. In the Panel>Maintenance menu, press [LCD Brightness]. Adjust the following parameter. Knob Parameter Adjustment Setting values Brightness...
Setup Relating to Switcher Processor Settings for Switcher Configuration (Config Menu) To make settings for the switcher processor, use the Switcher>Config menu. To display the Config menu In the Engineering Setup menu, select VF3 ‘Switcher’ and HF1 ‘Config.’ The status area shows the output signal assignment for each operating bank. Adjusting the reference phase To adjust the switcher internal reference phase, adjust the following parameter in the Switcher>Config menu.
Page 104
To assign the output of each bank in Multi Program mode When you selected [Multi Program] in the procedure described in “Setting the operating mode” (page 103), use the following procedure. In the Switcher>Config menu, press [M/E Output Assign]. The M/E Output Assign menu appears. On the list in the status area, select the bank output to be assigned.
Page 105
In each of the <Key1> to <Key4> groups, select [Enable] or [Disable]. To set the key preview configuration You can make this setting at any time, regardless of the operation mode. In the Switcher>Config menu, press [K-PVW Config]. The K-PVW Config menu appears. The status area shows the key preview configuration for each bank.
Signal Input Settings (Input Menu) For setup relating to signal inputs, use the Switcher>Input menu. To display the Input menu In the Engineering Setup menu, select VF3 ‘Switcher’ and HF2 ‘Input.’ The status area shows source numbers and source names, input signal phase, and through mode on/off setting.
Press [Video Process], turning it on. Adjust the following parameters. Knob Parameter Adjustment Setting values −200.00 to +200.00 Video Gain Video signal gain −200.00 to +200.00 Y Gain Y signal gain −200.00 to +200.00 C Gain Chrominance signal gain −180.00 to +180.00 Hue Delay Hue delay −7.30 to +109.58...
Page 108
PGM/PST 1 to 6 DME Monitor Video DME Monitor Key [Aux Bus]: It is not possible to make duplicate assignments. Preset Edit Preview AUX 1 to 48 Using any of the following methods, select the output port number and signal to be assigned. •...
Page 109
Adjust the following parameters. Knob Parameter Adjustment Setting values White Clip Luminance signal white clip value 90.00 to 109.00 −6.85 to +10.00 Dark Clip Luminance signal dark clip value Chroma Clip Chrominance signal clip value 90.00 to 113.17 To set the values to the default values, press [Default]. Making vertical blanking interval adjustment and through mode settings Use the following procedure.
To enable the on/off settings made in the Misc menu, press [Safe Title], turning it on. Carry out either of the following operations. To display a box: Press [Box1] or [Box2], turning it on. In this case, carry out the following steps 4 and 5. To display a cross: Press [Cross], turning it on.
Page 111
• Press directly on the list appearing in the status area. • Press the arrow keys to scroll the reverse video cursor. • Turn knob 1 to make the selection. Knob Parameter Adjustment Setting values Bank M/E or P/P selection to which settings apply 1 to 4 The selected bank appears in reverse video.
In the Switcher>Transition menu, press [Transition Curve]. The Transition Curve menu appears. In the <Fader Curve> group, select the fader lever operation mode. Normal: The transition progress is linear, according to the fader lever position. (Factory default setting) Adv Tally Mode: When the fader lever is moved from the end of its travel, the tally is output slightly before the transition starts.
Page 113
In the <Show Key Enable> group, press the signal for which “show key” is enabled, turning it on. To set the time for which “show key” is held, press [Hold Time]. Adjust the following parameter. Knob Parameter Adjustment Setting values Hold Time Show key hold time 0 to 999 (frames)
Auto: When the pattern limit is released, the remainder of the transition is carried out automatically at a special-purpose transition rate. Manual: After the pattern limit is released, the transition waits for the next operation, then executes. Until you move the fader lever or press [AUTO TRANS], the transition is not executed.
Page 115
Knob Parameter Adjustment Setting values Link No Link number 1 to 64 Press [Link Bus Select]. The Link Bus Select menu appears. The status area lists the current setting status of the selected link and the buses that can be selected. In the <Bus Select>...
Page 116
Using any of the following methods, select the link source and link destination signals. • Press directly on the list appearing in the status area. • Press the arrow keys to scroll the reverse video cursor. • Turn the knobs to make the setting. Knob Parameter Adjustment...
Page 117
Knob Parameter Adjustment Setting values GPI Port GPI output port selection 1 to 8 Press [GPI Link Adjust]. The Link Bus Select menu appears. The status area shows the current setting state of the selected link, and a list of the selectable video names or button names, together with the GPI link Enable/Disable setting for each bus.
In the <Bus> group, select any of the following. Enable: Enable the GPI link setting for the selected bus. Disable: Disable the GPI link setting for the selected bus. All Enable: Enable the GPI link setting for all buses. To set the delay value Use the following procedure.
Page 119
Knob Parameter Adjustment Setting values Port Port selection 1 to 8 Selection of number for action to be 1 to 8 assigned In the <Trigger Type> group, select the trigger type. : Apply the trigger on a rising edge of an input pulse. : Apply the trigger on a falling edge of an input pulse.
Page 120
When Target is Common/Setup: FM Src1 Field Freeze, FM Src1 Frame Freeze, FM Src2 Field Freeze, FM Src2 Frame Freeze FM Src1 Freeze Off, FM Src2 Freeze Off User1 SS ? Recall, User1 EFF ? Recall, User1 EFF ? Recall & Run, User1 KF Run, User1 KF Stop, User1 KF Rewind User2 SS ? Recall, User2 EFF ? Recall, User2 EFF ? Recall &...
Page 121
In the Switcher>Device Interface menu, press [GPI Output]. The GPI Output menu appears. Using any of the following methods, select the settings. • Press directly on the list appearing in the status area. • Press the arrow keys to scroll the reverse video cursor. •...
Page 122
Knob Parameter Adjustment Setting values Action Action selection 1 to ... Reg No Register number 1 to 99 1 to 399 a) • Action list when the trigger type is other than “Status” When Source is M/E-1, M/E-2, or M/E-3: Cut, Auto Trans Key1 Cut, Key1 Auto Trans, Key2 Cut, Key2 Auto Trans, Key3 Cut, Key3 Auto Trans, Key4 Cut, Key4 Auto Trans Key1 SS ? Recall, Key2 SS ? Recall, Key3 SS ? Recall, Key4 SS ? Recall...
Setup Relating to DME Note To use DME requires the BKDS-9470 DME Board Set. Settings Relating to Signal Inputs (Input Menu) To make settings relating to DME input signals, display the DME>Input menu. To display the Input menu In the Engineering Setup menu, select VF4 ‘DME’ and HF1 ‘Input.’ The status area shows the input signal numbers and names, together with initial crop information.
To return the parameter values to their default values Press [Unity]. Setting an illegal color limit for matte signals To prevent an illegal color from being generated in a matte signal, in the DME>Input menu, press [Matte Illeg Col Limit], turning it on. Interfacing With External Devices (Device Interface Menu) To carry out setup relating to DME connections with external devices, display...
Page 125
Knob Parameter Adjustment Setting values Selection of number for action to 1 to 8 be assigned In the <Trigger Type> group, select the trigger polarity. : Apply the trigger on a rising edge of an input pulse. : Apply the trigger on a falling edge of an input pulse. : Apply the trigger on a change in the polarity of the input signal.
Page 126
In the DME>Device Interface menu, select the action to be set, and press [H/L Set]. The H/L Set menu appears. Using any of the following methods, select the settings. • Press directly on the list appearing in the status area. •...
Setup Relating to DCU Settings Relating to Signal Inputs (Input Config Menu) The DCU parallel ports are assigned with the following priority sequence. 1. When external boxes are set, external boxes 1 to 4 are assigned from the first parallel port. 2.
Releasing the assignment of a GPI input port Use the following procedure. In the DCU>Input Config menu, select what the setting applies to (DCU1 or DCU2) from the <DCU Select> group. Turn the knobs to adjust the following parameters. Knob Parameter Adjustment Setting values...
Page 129
: Apply the trigger on a change in the polarity of the input signal. (Level): When the input is low or high, the specified signal format or screen aspect ratio applies. (See “Carrying out level settings” (page 120).) No Operation: Apply no trigger on an input pulse. In the <Target Device>...
• Action list when the trigger type is “Level” Simul, Custom , Format (frame/field rate, number of lines) (System Format, SWR Format, DME Ch1-Ch4 Format Aspect (System Aspect, SWR Aspect, M/E-1 Aspect, M/E-2 Aspect, M/E-3 Aspect, P/P Aspect, DME Ch1-Ch4 Aspect DME Ch1 Aspect, DME Ch2 Aspect, DME Ch3 Aspect, DME Ch4 Aspect No Action b) When knob 2 selection is “Snapshot”...
Page 131
To display the Output Config menu In Engineering Setup, select VF5 ‘DCU’ and HF3 ‘Output Config.’ The status area shows output port information. Assigning a GPI output port Use the following procedure. In the DCU>Output Config menu, select what the setting applies to (DCU1 or DCU2) from the <DCU Select>...
In the <Parallel Output Assign> group, press [No Assign]. GPI Output Setting (GPI Output Assign Menu) To set the trigger type and so on for each GPI output, display the DCU>GPI Output Assign menu. To display the GPI Output Assign menu In Engineering Setup, select VF5 ‘DCU’...
Page 133
a) 1: Field 1, 2: Field 2, 3: Any In the <Source Device> group, select the action block. Using any of the following methods, select the action you want to set. • Press directly on the list appearing in the status area. •...
Setup Relating to Router Interface and Tally Router Interface Settings (Router Menu) In this system, the interface with a router (routing switcher) uses the S-Bus protocol. It is therefore necessary to assign inputs and outputs of the switcher and so on to an S-Bus space. To carry out this assignment, use the Router/Tally>Router menu.
Page 135
Level: Specify the level in the S-Bus space. Knob Parameter Adjustment Setting values Source Source start address 1 to maximum value Destination Destination start address 1 to maximum value Level Level 1 to 8 a) When the matrix size is Standard, the maximum value is 889. For the Compact size, the maximum value is 897.
In the External Box Assign menu, select [External box1] from the <Device> group. In the <Matrix Size> group, select [8×1]. Turn the knobs to make adjustments. Knob Parameter Adjustment Setting values Source Source start address 1 to 1017 Destination Destination start address 1 to 1024 Level Level...
Press [S-Bus Tally], turning it on or off. On: Enable the transfer of S-Bus tally information over the S-Bus. Off: Disable the transfer of S-Bus tally information over the S-Bus. Wiring Settings (Wiring Menu) When configuring a system in which the switcher inputs and outputs are connected to a router, it is necessary to set this connection configuration (referred to as “wiring”) in the S-Bus space.
Page 138
Set the source. Source From: Specify the source start address for the wiring configuration. Source Level: Specify the source level for the wiring configuration. Knob Parameter Adjustment Setting values Source From Source start address 1 to 1024 Source Level Source level 1 to 8 Press [Execute].
Tally Generation Settings (Tally Enable Menu) For settings relating to tally generation, use the Router/Tally>Tally Enable menu. To display the Tally Enable menu In the Engineering Setup menu, select VF7 ‘Router/Tally’ and HF4 ‘Tally Enable.’ The status area shows the tally generation settings. Making new tally generation settings Use the following procedure.
DCU2: Generate tally with reference to signal input to DCU2 port. Set the port number with the knob. With a knob or menu operation, select the tally input port number. Knob Parameter Adjustment Setting values Input No Tally input port number 1 to 102 Press [Execute].
Page 141
To display the Tally Copy menu In the Engineering Setup menu, select VF7 ‘Router/Tally’ and HF5 ‘Tally Copy.’ The status area shows the tally copy status. Making new tally copy settings Use the following procedure. In the Router/Tally>Tally Copy menu, select [New]. The New menu appears.
Knob Parameter Adjustment Setting values Copy To Copy-to source 1 to 1024 Press [Execute]. This updates the tally copy settings. Deleting tally copy settings Use the following procedure. In the Router/Tally>Tally Copy menu, using either of the following methods, select the tally copy whose settings you want to delete. •...
Page 143
• Press the arrow keys to scroll the reverse video cursor. • Turn the knobs to make the setting. Knob Parameter Adjustment Setting values Slot No Parallel tally slot number 2 to 6 Port No Parallel tally port number 1 to 54 Press [Set].
Page 144
• Press the arrow keys to scroll the reverse video cursor. • Turn the knobs to make the setting. Knob Parameter Adjustment Setting values Slot No Parallel tally slot number 2 to 6 Port No Parallel tally port number 1 to 54 Press [Clear].
The setting does not change immediately. In the Engineering Setup>Router/Tally> Router menu, set the position of the DVS-9000 system in S-BUS space. Select the setting from SWR1 and SWR2, and set each of Source, Destination, and Level to 1.
Since when using the simple connection the switcher and routing switcher cannot be connected in cascade, no route setting is required, and this is unset. O: SET AVAILABLE SOURCE/DESTINATION Set the source and destination ranges so that the DVS-9000 inputs and outputs can be selected. Y: SET DISPLAY MODES The DISPLAY MODES/PANEL FUNCTION setting is set to NORMAL.
Operations on Individual Files You can save or recall the contents of an individual file or register. Carry out these operations in the File menu. To access the File menu In the menu control block, press the top menu selection button [FILE]. This explanation shows the example of the File>Effect, Snapshot menu in which you carry out keyframe effect and snapshot file operations, but the procedure is similar in the following menus.
D1: device 1 related data D2: device 2 related data Selecting Regions You can carry out file operations on multiple regions simultaneously. However, since the setup, initial status, video process memory, key memory and frame memory operations are carried out independent of the regions, no region selection is required for them.
Saving Files To save the contents of a register on the hard disk or memory card, use the following procedure. In the File menu, select VF3 ‘Effect, Snapshot’ and HF1 ‘Save.’ The File>Effect, Snapshot>Save menu appears. The top side of the status area shows the register name, and the bottom side shows the save destination.
The File>Effect, Snapshot>Load menu appears. The top side of the status area shows the location where the file is saved, and the bottom side shows the register. If necessary, change the currently selected medium for recording ([HDD] or [Memory Card]). (See “Selecting the Recording Medium” (page 149).) In the <Category>...
If necessary, change the currently selected medium for recording ([HDD] or [Memory Card]) for each of the copy source and copy destination. (See “Selecting the Recording Medium” (page 149).) In the <Category> group, select what the operation applies to. Effect: keyframe effect file Snapshot: snapshot file In the <Select>...
In the <Select> group, choose the method of selection, and in the status area, select the files. All: When this is on, all files are selected for the operation. Plural: When this is on, you can specify a number of files to which the operation will apply.
Press [Delete]. Renaming Files To change the name of a file on the hard disk or memory card, use the following procedure. In the File menu, select VF3 ‘Effect, Snapshot’ and HF6 ‘Rename.’ The File>Effect, Snapshot>Rename menu appears. The status area shows the list of files.
File Batch Operations You can batch process all files or registers. Carry out these operations using the File>All/Directory menu. To access the File>All/Directory menu Press the top menu selection button [FILE], then select VF7 ‘All/Directory.’ Batch Saving Files To save the data of all registers to hard disk or memory card, use the following procedure.
Page 156
The Load menu appears. In the <Load From> group, select [HDD] (hard disk) or [Memory Card]. Select the files to which the operation applies. In the <Category> group, press the buttons for files you do not want to recall, removing them from the selection. For details of the data to which the operation applies, see “Files”...
Menu Tree Recalling Menus This section details the menu structure, and shows the top menu selection buttons in the menu control block which are used to access the menus. Top menu selection buttons DISPL MENU FRAME COLOR COPY BKGD /MON COPY MISC SWAP...
Index for one-channel mode 166 Flip tumble 167 for two-channel mode Formatting a memory card 83 Attributes 58 Frame Memory menu 174 AUX bus remote panel 145 Door 167 Function links 114 AUX delegation button DSK auto drop function 113 settings 94 Duration mode setting 33 shift operation 95...
Page 186
operations 20 for DCU 130 path setting 37 Reference for switcher processor pause 33 output setting 110 register operations 46 phase adjustment 103 Simple connection 145 Region 23 Slide 166, 170 selection 149 Snapshot Register menu 179 M/E-1 to M/E-3 menus 171 operations in the menus register editing 58 Memory card formatting 83...
Page 189
The material contained in this manual consists of infor- mation that is the property of Sony Corporation and is intended solely for use by the purchasers of the equip- ment described in this manual. Sony Corporation expressly prohibits the duplication of...
Page 190
Sony Corporation B & P Company DVS-9000/9000SF Printed in Japan System (WW) 2002.08.13 2002 3-704-675-01 (1) Printed on recycled paper...