ASV13P Series ASV18P Series ASV24P Series Air Conditioner user & installation manual imagine the possibilities Thank you for purchasing this Samsung product. To receive more complete service, please register your product at www.samsung.com/register DB98-32965B(5)
Features of your new air conditioner Contents USING PARTS Safety precautions ................. 3 On those hot sweltering summer days and long restless Checking before use ..............6 nights, there is no better escape from the heat than the Checking the name of the parts ..........7 cool comforts of home.
USING PARTS Safety precautions Before using your new air conditioner, please read this manual thoroughly to ensure that you know how to safely and online at www.samsung.com. Important safety symbols and precautions: WARNING Hazards or unsafe practices that may result in severe personal injury or death.
Page 4
Safety precautions FOR POWER SUPPLY WARNING Remove all foreign substances such as dust or water from the power plug terminals and contact points using a dry cloth on a regular basis. Unplug the power plug and clean it with a dry cloth. ...
Page 5
FOR USING WARNING Do not place an object near the outdoor unit that allows children to climb onto the machine. This may result in children seriously injuring themselves. Since this may be dangerous due to a lack of oxygen, Open a window at least once an hour. ...
Checking before use Operation ranges The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the Indoor Outdoor Indoor Mode Remark temperature temperature humidity Relative Cooling humidity ASV10/13/18/24P 16˚C~32˚C 16˚C~46˚C 80% or less 18˚C~32˚C 16˚C~46˚C ASV10/13/18/24P ...
Checking the name of the parts below Main parts temperature sensor Air intake (up and down) Blade pin lever Display indicator Timer/Auto clean indicator Operation indicator Power button Remote controller receiver...
Checking the remote controller • Point the remote controller towards the remote controller receiver of the indoor unit. • When you properly press the button on the remote controller, you will hear beep sound from the indoor unit and a transmit indicator( ) appears on the remote controller display.
Remote controller display Operation mode Turbo indicator indicator SPi indicator Low battery indicator Cool Quiet indicator Transmit indicator Smart Saver indicator Air swing indicator Use 2 function Fan speed indicator indicator Auto (Turbo) On Timer indicator Medium indicator High d’light Cool indicator Battery changing time When the battery is exhausted, ( ) will be displayed in the remote controller display.
Basic function Basic operation is an operation mode that can be selected by pressing the Mode button. Auto In Auto mode, the air conditioner will automatically set the temperature and fan speed depending on the room temperature detected by the room temperature. •...
Page 11
Press the button to turn on the air conditioner. Press the button to set the operating mode. • Each time you press the Mode button, the mode will change in order of Auto, Cool, Dry, Fan and Heat. Press the button to set the desired fan speed.
Press the Air swing button on the remote controller. circulate the air. Press the Air swing direction in a constant position. position you prefer. • Be extremely careful with your while adjusting the Horizontal There is a potential risk of personal injury when the unit is mishandled.
mode For a comfortable sleep, the air conditioner will operate it Fall asleep Sound sleep Wake up from mode. When the air conditioner is on and in cool/heat mode 1. Press the button on the remote controller. controller display.
Page 14
1. Press the button. Setting On timer 2. Press the button to set the time. You can set the time in half hourly unit from 30 minutes ~ 3 hours and hour unit from 3 hours ~ 24 hours. Operating hour can be set from minimum 30 minutes to maximum ...
If the air conditioner is on Ex) On timer : 3 hours, timer : 5 hours Ex) On timer : 3 hours, timer : 1 hour - The air conditioner will operate On timer after 3 hours from the moment you have set the timer. 1 hour from the moment you have set the timer.
Using the Quiet function You can reduce the noise generated from an indoor unit. Press the Quiet button on the remote controller while the air conditioner is operating in Cool/Heat mode. Quiet indicator appears on the remote controller display. The indoor unit will operate more quietly.
Cleaning the air conditioner • the wall socket when cleaning the air conditioner. Cleaning the indoor unit Wipe the surface of the unit with a slightly wet or dry cloth when needed. • Contact the service center when you clean the indoor unit heat exchanger because it needs to be disassembled.
Page 18
Cleaning the air conditioner and slide it down. Open the panel and put the A ter out. Clean the A ter with a vacuum cleaner or soft brush. If dust is too heavy, rinse it with running water. Insert the A ter back in its original position Dry the Ai lter in a ventilated area.
Maintaining the air conditioner If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best condition. 1. Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and disconnect the power plug. There may be internal damage if moisture is left in components.
Troubleshooting Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses. PROBLEM SOLUTION The air conditioner does • Check power status and then operate the air conditioner again. not work at all. •...
Page 21
PROBLEM SOLUTION Error is indicated. • When an indoor unit indicator blinks, contact the nearest service center. Noise is generated. • Depending on the status of the air conditioner usage, noise can be heard when refrigerant Smoke is generated from •...
SAMSUNG’s technical support if the unit produces smoke, if the power cable is hot or damaged or if the unit is very noisy. Always remember to inspect the unit, electric connections, refrigerant tubes and protections regularly. These operations ...
Installing the unit IMPORTANT: When installing the unit, always remember to connect the refrigerant tubes, then the electrical lines. Always disassemble the electric lines before the refrigerant tubes. Upon receipt, inspect the product to verify that it has not been damaged during transport. ...
Choosing the installation location Outdoor Unit Where it is not exposed to strong wind Well ventilated and dustless places Out of the direct sunlight and rain Where neighbors are not annoyed by operation sound or hot air ...
Page 25
Space Requirements for Outdoor Unit When installing 1 outdoor unit Figure Description Top view Side view Air intake Air outlet Air intake Air outlet Air ow direction (Unit : mm) When the air outlet is opposite the When the air outlet is towards the When 3 sides of the outdoor unit are ...
Choosing the installation location (Unit : mm) When the walls are blocking front and the rear side of the outdoor units When the upper part of the outdoor unit and the air outlet is opposite the wall 300 or more 600 or more 600 or more When front and rear side of the outdoor unit is towards the wall...
Optional accessories If using a multi system, refer to the manual supplied with the outdoor unit. The following connection accessories are optional. If they are not supplied, you should obtain them before installing the air conditioner. Insulated Insulated Assembly Insulated Assembly Pipe, Insulated Assembly Pipe, PE T3 Foam Tube Vinyl Tapes (2)
Fixing the installation plate 2. Fix the indoor unit. (1) Fix the installation plate to the wall giving attention to the weight of the indoor unit. Plastic • If you mount the plate to a concrete wall using plastic anchors, make sure that Anchor Wall gaps between the wall and the plate, created by projected anchor, is less than...
Page 29
There must be no space between the terminal and the screw when connected. The terminal socket is upside down. or there is a space between the screw and the ring terminal. • For the terminal block wiring, use a wire with a ring terminal socket only. CAUTION ng work.
Installing and connecting the assembly pipe of the indoor unit refrigeration grade pipe only, (Cu DHP type according to ISO1337), degreased and deoxidized, suitable for operating pressures of at least 4200 kPa and for burst pressure of at least 20700 kPa. Under no circumstances must sanitary type copper pipe be used.
Purging the indoor unit he indoor unit is supplied with inert gas (nitrogen). Before installing the unit, check if nitrogen gas ows out of indoor unit. If this one isn’t true, DO NOT INSTALL THE UNIT since leakage could be inside the indoor unit. 1.
Cutting or extending the pipe Correct Damaged Uneven Inclined Cracked Surface Thickness applying the following torque: Outer Diameter Torque (kgf•cm) Flare nut ø6.35 mm 140~170 ø9.52 mm 250~280 ø12.70 mm 380~420 ø15.88 mm 440~480 Indoor outlet pipe Connecting pipe • Excessive torque can be cause of gas leakage. In case brazing the pipe, the nitrogen gas must be blown into the pipe (50 Pa).
Drain hose installation 1. If necessary, connect the 2-meter extension drain hose to the drain hose. 2. If you use the extension drain hose, insulate the inside of the extension drain hose with a shield. tightly with a clamp. • If you do not use the other drain hose hole, block it with a rubber stopper. Drain hose hole 4.
Purging the connected pipes If using a multi system, install as described in the installation manual supplied with the outdoor unit. The outdoor unit is loaded with R410A refrigerant. Do not vent R410A into atmosphere: it is a greenhouse gas, covered by Kyoto Protocol, with a Global Warming Potential (GWP) = 1975. It may cause reduction of cooling capacity and malfunction.
3. Connect the charging hose of the low-pressure side of manifold gauge to a Manifold gauge gas service port as seen in the picture. 4. Open the valve of the low pressure side of manifold gauge counterclockwise. Valve 5. Purge the air in the connected pipes using the vacuum pump for about Gas service port 15 minutes.
Page 36
Purging the connected pipes Important information regulation regarding the refrigerant used Refrigerant type GWP value Protocol. R410A 1975 Do not vent gases into the atmosphere. GWP=Global Warming Potential the factory refrigerant charge of the product, covered by the Kyoto Protocol. ...
Performing the gas leak tests If using a multi system, install as described in the installation manual supplied with the outdoor unit. Make sure to check for gas leaks before completing the installation process (connecting the assembly pipe and hose between To check for gas leaks on the outdoor unit, Check the valve A and B using a leak detector.
Fixing the indoor unit in place Perform the following work on the area where gas leak test was done priorly. After checking for gas leaks in the system, insulate the pipe, hose and cables. Insulation Then place the indoor unit on the installation plate. part without insulation on the end of the pipes.
Final Check and Trial Operation To complete the installation, perform the following checks and tests to ensure that the air conditioner operates correctly. Check the followings: • Strength of the installation site • Tightness of pipe connection to detect gas leak •...
How to connect your extended power cables Items to prepare (compressor and insulation tape should be prepared by an installation technician.) Tools Crimping plier Connection sleeve (mm) Insulation tape Contraction tube (mm) Spec MH-14 20xØ7.0(HxOD) Width 18mm 50xØ8.0(LxOD) Shape (Unit: mm) of the power cable.
Page 41
QUESTIONS OR COMMENTS? COUNTRY CALL OR VISIT US ONLINE AT INDONESIA 0800-112-8888 www.samsung.com 021-5699-7777 www.samsung.com MALAYSIA 1-800-10-SAMSUNG(726-7864) for PLDT 1-800-3-SAMSUNG(726-7864) for Digitel PHILIPPINES www.samsung.com 1-800-8-SAMSUNG(726-7864) for Globe 02-5805777 SINGAPORE 1800-SAMSUN G (726-7864) www.samsung.com TAIWAN 0800-329-999 www.samsung.com 0266-026-066 www.samsung.com VIETNAM 1 800 588 889...